FOR YOUR SAFETY
WARNING: If the information in these
instructions is not followed exactly, a fire
or explosion may result causing property
damage, injury, or death.
- Donotstoreorusegasolineorotheram-
mablevaporsorliquidsinthevicinityofthis
oranyotherappliance.
WHAT TO DO IF YOU SMELL GAS:
• Donottrytolightanyappliance.
• Donottouchanyelectricalswitch;donotuse
anyphoneinyourbuilding.
• Immediatelycallyourgassupplierfroma
neighbor’sphone.Followthegassupplier’s
instructions.
• Ifyoucannotreachyourgassupplier,callthe
redepartment.
-Installationandservicemustbeperformedby
aqualiedinstaller,serviceagency,orthegas
supplier.
POOL AND SPA/HOT TUB HEATERS
H250FDN & H250FDP; H350FDN & H350FDP;
H400FDN & H400FDP MODELS
OWNER’S MANUAL
FOR YOUR SAFETY
Thisproductmustbeinstalledandservicedbyauthorizedpersonnel,qualiedinpool/spa
heaterinstallation.Improperinstallationand/oroperationcancreatecarbonmonoxidegas
anduegasesthatcancauseseriousinjury,propertydamage,ordeath.
1301640701 REV D MMYY

Pomona, CA Clemmons, NC Nashville,TN
Tel: 908-351-5400 www.haywardpool.com
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
2
Warnings .......................................................................................................3
Section I General information........................................................................7
Section II. Consumer Operation & Maintenance ...........................................8
Maintaining proper water chemistry...............................................................8
Lighting & Operating instructions label........................................................10
Operation: Set point adjustment ................................................................. 11
Fahrenheit versus Celsius...........................................................................11
Keypad inputs..............................................................................................11
Winterization................................................................................................11
Spring start-up.............................................................................................12
Error codes..................................................................................................12
Warranty ......................................................................................................14
CONTENTS

Pomona, CA Clemmons, NC Nashville,TN
Tel: 908-351-5400 www.haywardpool.com
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
3
Basicsafetyprecautionsshouldalwaysbefollowed,includingthefollowing:Failuretofollowinstructions
cancausesevereinjuryand/ordeath.
Thisisthesafety-alertsymbol.Whenyouseethissymbolonyourequipmentorinthismanual,lookfor
oneofthefollowingsignalwordsandbealerttothepotentialforpersonalinjury.
WARNINGwarnsabouthazardsthatcouldcauseseriouspersonalinjury,deathormajorpropertydam-
ageandifignoredpresentsapotentialhazard.
CAUTIONwarnsabouthazardsthatwillorcancauseminorormoderatepersonalinjuryand/orprop-
ertydamageandifignoredpresentsapotentialhazard.Itcanalsomakeconsumersawareofactionsthat
areunpredictableandunsafe.
ATTENTIONindicatesspecialinstructionsthatareimportantbutnotrelatedtohazards.
READ AND FOLLOW ALL INSTRUCTIONS IN THIS OWNER’S
MANUAL AND ON EQUIPMENT.
IMPORTANT SAFETY INSTRUCTIONS
Before installing or servicing this electrical equipment, turn power supply OFF.
KEEP SAFETY LABELS IN GOOD CONDITION AND REPLACE IF MISSING OR DAMAGED.
WARNING–Toreduceriskofinjury,donotpermitchildrentouseorclimbontheheater,pumpsor
lters.Closelysupervisechildrenatalltimes.Componentssuchastheltrationsystem,pumps,and
heatersmustbepositionedtopreventchildrenfromusingthemasameansofaccesstothepool.
CAUTION –Thisheaterisintendedforuseonpermanentlyinstalledswimmingpoolsandmayalso
beusedwithspas.DoNOTusewithstorablepools.Apermanentlyinstalledpoolisconstructedinor
onthegroundorinabuildingsuchthatitcannotbereadilydisassembledforstorage.Astorablepoolis
constructedsothatitiscapableofbeingreadilydisassembledforstorageandreassembledtoitsoriginal
integrity.
Thoughthisproductisdesignedforoutdooruse,itisstronglyrecommendedtoprotecttheelectrical
componentsfromtheweather.Selectawelldrainedarea,onethatwillnotoodwhenitrains.Itrequiresfree
circulationofairforcooling.Donotinstallinadampornon-ventilatedlocation.
WARNING –Itisrequiredthatlicensedelectriciansdoallelectricalwiring.Riskof
ElectricShock.Hazardousvoltagecanshock,burn,causedeathorseriousproperty
damage.Toreducetheriskofelectricshock,doNOTuseanextensioncordtoconnect
unittoelectricsupply.Provideaproperlylocatedoutlet.AllelectricalwiringMUSTbe
inconformancewithapplicablelocalandnationalcodesandregulations.Beforework-
ingonthisunit,turnoffpowersupplytotheheater.
WARNING –Toreducetheriskofelectricshockreplacedamagedwiringimmediately.Locateconduit
topreventabusefromlawnmowers,hedgetrimmersandotherequipment.
WARNING –Failuretobondtopoolstructurewillincreaseriskforelectrocutionandcouldresultin
injuryordeath.Toreducetheriskofelectricshock,theelectricianmustcomplywithinstallationin-
structionsandmustbondtheheateraccordingly.Inaddition,thelicensedelectricianmustalsoconform
tolocalelectricalcodesforbondingrequirements.
SAFETY INFORMATION

Pomona, CA Clemmons, NC Nashville,TN
Tel: 908-351-5400 www.haywardpool.com
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
4
NOTES TO THE ELECTRICIAN:
Useasolidcopperconductor,size8orlarger.Runacontinuouswirefromexternalbondinglugtorein-
forcingrodormesh.ConnectaNo.8AWGsolidcopperbondingwiretothegroundinglugprovidedonthe
heaterandtoallmetalpartsofswimmingpoolorspa,andtoallelectricalequipment,metalpiping(except
gaspiping),andconduitwithin5ft.(1.5m)ofinsidewallsofswimmingpoolorspa.
IMPORTANT-ReferenceNECcodesforallwiringstandardsincluding,butnotlimitedto,grounding,
bondingandothergeneralwiringprocedures.
WARNING – Suction Entrapment Hazard.
Suctioninsuctionoutletsand/orsuctionoutletcoverswhicharedamaged,broken,
cracked,missing,orunsecuredcancausesevereinjuryand/ordeathduetothefol-
lowingentrapmenthazards:
Hair Entrapment-Haircanbecomeentangledinsuctionoutlets.
Limb Entrapment-Alimbinsertedintoanopeningofasuctionoutletorsuctionoutlet
coverthatisdamaged,broken,cracked,missing,ornotsecurelyattachedcanresultina
mechanicalbindorswellingofthelimb.
Body Suction Entrapment-Adifferentialpressureappliedtoalargeportionofthebodyorlimbscan
resultinanentrapment.
Evisceration/ Disembowelment-Avacuumapplieddirectlytotheintestinesthroughanunprotected
suctionoutletsumporsuctionoutletcoverwhichisdamaged,broken,cracked,missing,orunsecured
canresultinevisceration(disembowelment).
Mechanical Entrapment-Thereispotentialforjewelry,swimsuit,hairdecorations,nger,toeorknuck-
letobecaughtinanopeningofasuctionoutletorsuctionoutletcoverresultinginmechanicalentrap-
ment.
WARNING-Toreducetheriskofentrapmenthazards:
• Whensuctionoutletsarelessthana18”x23”equivalent,aminimumoftwofunction-
ingsuctionoutletsperpumpmustbeinstalled.Suctionoutletsinthesameplane(i.e.
oororwall),mustbeinstalledaminimumofthreefeet(3’)[1meter]apart,asmea-
suredfromnearpointtonearpoint.
• Dualsuctionoutletsshallbeplacedinsuchlocationsanddistancestoavoid“dual
blockage”byauser.
• Dualsuctionttingsshallnotbelocatedonseatingareasoronthebackrestforsuch
seatingareas.
• Themaximumsystemowrateshallnotexceedtheowratingofanylisted(percurrentrevisionof
ASME/ANSIA112.19.8)suctionoutletcoverinstalled.
• NeverusethePoolorSpaifanysuctionoutletcomponentisdamaged,broken,cracked,missing,or
notsecurelyattached.
• Replacedamaged,broken,cracked,missing,ornotsecurelyattachedsuctionoutletcomponentsim-
mediately.
• InstalltwoormoresuctionoutletsperpumpinaccordancewithlatestAPSP(formallyNSPI)Stan-
dardsandCPSCguidelines.FollowallapplicableNational,State,andLocalcodes.

Pomona, CA Clemmons, NC Nashville,TN
Tel: 908-351-5400 www.haywardpool.com
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
5
WARNING–Failuretoremovepressuretestplugsand/orplugsusedinwinterizationofthepool/spa
fromthesuctionoutletscanresultinanincreasepotentialforsuctionentrapmentasdescribedabove.
WARNING–Failuretokeepsuctionoutletcomponentsclearofdebris,suchasleaves,dirt,hair,paper
andothermaterialcanresultinanincreasepotentialforsuctionentrapmentasdescribedabove.
WARNING–Suctionoutletcomponentshaveanitelife,thecover/grateshouldbeinspectedfre-
quentlyandreplacedatleasteverytenyearsoriffoundtobedamaged,broken,cracked,missing,ornot
securelyattached.
WARNING–AllsuctionanddischargevalvesMUSTbeOPENwhenstartingthecirculationsystem.
Failuretodosocouldresultinseverepersonalinjuryand/orpropertydamage.Alldrainsandsuction
outletsMUSThaveproperlyinstalledcovers,securelyattachedusingthescrewssuppliedwiththecov-
ers.Ifscrewsarelost,orderreplacementpartsfromyoursupplier.
WARNING – Hazardous Pressure.Poolandspawatercirculationsystemsoperate
underhazardouspressureduringstartup,normaloperation,andafterpumpshutoff.
Standclearofcirculationsystemequipmentduringstartup.Failuretofollowsafety
andoperationinstructionscouldresultinviolentseparationofthepumphousing
andcoverduetopressureinthesystem,whichcouldcausepropertydamage,severe
personalinjury,ordeath.Beforeservicingpoolandspawatercirculationsystem,all
systemandpumpcontrolsmustbeinoffpositionandltermanualairreliefvalve
mustbeinopenposition.Beforestartingsystempump,allsystemvalvesmustbeset
inapositiontoallowsystemwatertoreturnbacktothepool.Donotchangelter
controlvalvepositionwhilesystempumpisrunning.Beforestartingsystempump,
fullyopenltermanualairreliefvalve.Donotcloseltermanualairreliefvalve
untilasteadystreamofwater(notairorairandwater)isdischarged.
WARNING – Separation Hazard.Failuretofollowsafetyandoperationinstruc-
tionscouldresultinviolentseparationofpumpcomponents.Strainercovermustbe
properlysecuredtopumphousingwithstrainercoverlockring.Beforeservicing
poolandspacirculationsystem,manualairreliefvalvemustbeinopenposition.Do
notoperatepoolandspacirculationsystemifasystemcomponentisnotassembled
properly,damaged,ormissing.Donotoperatepoolandspacirculationsystemunless
lterairreliefvalvebodyisinlockedpositioninlterupperbody.
WARNING –Neveroperateortestthecirculationsystematmorethan40PSI.
WARNING–Fireandburnhazard.Motorsoperateathightemperaturesandiftheyarenotproperly
isolatedfromanyammablestructuresorforeigndebristheycancauseres,whichmaycausesevere
personalinjuryordeath.Itisalsonecessarytoallowthemotortocoolforatleast20minutespriorto
maintenancetominimizetheriskofburns.
WARNING–Failuretoinstallaccordingtodenedinstructionsmayresultinseverepersonalinjuryor
death.

Pomona, CA Clemmons, NC Nashville,TN
Tel: 908-351-5400 www.haywardpool.com
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
6
WARNING–Thefollowing“SafetyRulesforHotTubs”recommendedbytheU.S.Consumer
ProductSafetyCommissionshouldbeobservedwhenusingthespa.
1. Spaorhottubwatertemperaturesshouldneverexceed104°F[40°C].Atemperatureof100°F
[38°C]isconsideredsafeforahealthyadult.Specialcautionissuggestedforyoungchildren.Pro-
longedimmersioninhotwatercaninducehyperthermia.
2. Drinkingofalcoholicbeveragesbeforeorduringspaorhottubusecancausedrowsiness,which
couldleadtounconsciousnessandsubsequentlyresultindrowning.
3. Pregnantwomenbeware!Soakinginwaterabove100°F[38°C]cancausefetaldamageduringthe
rstthreemonthsofpregnancy(resultinginthebirthofabrain-damagedordeformedchild).Preg-
nantwomenshouldadheretothe100°F[38°C]maximumrule.
4. Beforeenteringthespaorhottub,usersshouldcheckthewatertemperaturewithanaccuratether-
mometer;spaorhottubthermostatsmayerrinregulatingwatertemperaturesbyasmuchas4°F
(2.2°C).
5. Personstakingmedications,whichinducedrowsiness,suchastranquilizers,antihistaminesoranti-
coagulants,shouldnotusespasorhottubs.
6. Ifthepool/spaisusedfortherapy,itshouldbedonewiththeadviceofaphysician.Alwaysstirpool/
spawaterbeforeenteringthepool/spatomixinanyhotsurfacelayerofwaterthatmightexceed
healthfultemperaturelimitsandcauseinjury.Donottamperwithcontrols,becausescaldingcan
resultifsafetycontrolsarenotinproperworkingorder.
7. Personswithamedicalhistoryofheartdisease,circulatoryproblems,diabetesorbloodpressure
problemsshouldobtainaphysiciansadvicebeforeusingspasorhottubs.
8. Hyperthermiaoccurswhentheinternaltemperatureofthebodyreachesalevelseveraldegrees
abovenormalbodytemperatureof98.6°F[37°C].ThesymptomsofHyperthermiainclude:drowsi-
ness,lethargy,dizziness,fainting,andanincreaseintheinternaltemperatureofthebody.
The effects of Hyperthermia include:
1. Unawarenessofimpendingdanger.
2. Failuretoperceiveheat.
3. Failuretorecognizetheneedtoleavethespa.
4. Physicalinabilitytoexitthespa.
5. Fetaldamageinpregnantwomen.
6. Unconsciousnessresultingindangerofdrowning.
DEFINITIONS:
SuctionOutlet– ThetermSuctionOutletisatting,ttingassembly,cover/grateandrelatedcompo-
nentsthatprovideameansforwatertoexitthepoolandintothepumpcirculating
system.
Inchesof
Mercury(inHg)- Aunitformeasuringpressurebelowatmospheric(“suction”or“vacuum”)(1.0inch
Hg=.491PSI)
MainDrain– SeeSuctionOutlet
PSI– Anabbreviationforpoundspersquareinch.

Pomona, CA Clemmons, NC Nashville,TN
Tel: 908-351-5400 www.haywardpool.com
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
7
INTRODUCTION:
Thismanualcontainsinstructionsforinstallation,operation,maintenance,troubleshooting,andpartslists
forthesafeuseoftheswimmingpool/spa/hottubheaters.Haywardstronglyrecommendsthattheowner
readthemanualbeforeusingtheswimmingpool/spa/hottubheater.Ifafterreviewingthemanualanyques-
tionsremainunanswered,contactthefactoryorlocalrepresentative.
LIMITED WARRANTY SUMMARY:
Wewarrantthepool/spa/hottubheatertobefreefromdefectsinmaterialsandworkmanship,andwe
willwithinoneyearfromdateofinstallationforallusers,fortheoriginalpurchaser,repairor,atouroption,
replacewithoutchargeanydefectivepart.Wefurtherwarrantthatiftheheatexchangerorexchangerheaders
(water-containingsection)leakwithinoneyearfromdateofsuchinstallationforallusers,duetodefectsin
materialsandworkmanship,wewillprovideareplacementpart.Costoffreight,installation,fuel,andservice
labor(afteroneyear)isatuser’sexpense.Forfulldetailsofwarrantyagreement,seewarrantycerticate
includedinthismanual.
ATTENTION:Ifthepool/spa/hottubheaterisdamagedordestroyedbyimpropermaintenance,exces-
sivewaterhardness,incorrectwaterchemistry,orfreezingitisnotcoveredunderthemanufacturer’s
warranty.
SECTION I. GENERAL INFORMATION

Pomona, CA Clemmons, NC Nashville,TN
Tel: 908-351-5400 www.haywardpool.com
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
8SECTION II. CONSUMER OPERATION & MAINTENANCE
TheheatexchangerinyourHaywardpoolheaterismadefromthehighestqualityofcopperandnickel
(Cupronickel)materials.Thepremiummaterialsandtheexactingprocessesusedinthemanufactureofthe
heatexchangerisstateoftheartinpoolheaterdesignandmanufacture.Yet,itremainsvitalthattheheatex-
changerbeprotectedfromdamagingorcorrosivechemicals,insufcientwateroworimproperlybalanced
waterchemistry.Heatexchangerdamageorfailureresultingfromimproperow,improperlybalancedpool
waterortheimproperadditionofsanitizersintothewaterisNOTcoveredunderthetermsofyourwarranty.
Thefollowingfactorsarecriticaltoheatexchangerprotection.Followtheseguidelinestohelpprevent
pre-maturedamageorfailuretoyourheaterandheatexchanger.
1. WATER FLOW THROUGH HEATER
Watermustbeowingthroughtheheaterattheminimumratedowrateduringoperation.Checkthat
thepumpisoperatingandthesystemislledwithwaterandpurgedofallairpriortostartingtheheater.The
minimumratedowratesarelistedintheinstallationmanualonpage25.Someinstallationsmayrequirean
adjustmenttothewaterpressureswitchforproperlow-owprotection.Testyoursystemandifnecessary,
adjustthewaterpressureswitchasdescribedintheinstallationmanualonpage34.
2. POOL/SPA WATER CHEMISTRY
Thechemistrybalanceandmineralcontentofswimmingpoolwaterchangesdailyduetotheadditionof
poolandsanitizingchemicals,batherloads,rain,runoffandtheamountofsun-tonameafew.Improperchem-
istrybalanceandmineralcontentcancausescalinganddepositstoformonpoolwalls,intheltrationsystem,
intheheatexchangertubesandadditionallycanpromotecorrosiveactiontoallmetalsinthewaterpath.Chang-
ingspawaterregularlyandmaintainingthecorrectchemicalbalanceinyourpool/spawillkeepthepool/spa
safeandsanitary,andwillhelpprotecttheheatexchanger.Usea4-waypool/spawatertestkittocheckyour
waterfrequently(atleastweekly).Usethefollowingguidelinestohelpprotectyourheater’sheatexchanger:
3. SKIMMER CHLORINATION
Placingchlorineorbrominetabletsdirectlyintotheskimmermayresultinhighchemicalconcentrations
owingthroughtheheater.DONOTplacechlorineorbrominetabletsintheskimmer.
WARNING: Failure to Maintain Proper Water Chemistry May Cause
Premature Heat Exchanger Damage or Failure
MAINTAINING PROPER WATER CHEMISTRY
Recommended
Level Effect of Low Levels Effect of High Levels
Chlorine 1 - 3 ppm
Bromine 2 - 4 ppm
pH 7.4 - 7.6 corrosive to heat exchanger,
swimmer irritation
cloudy water, scaling of heat exchanger,
reduced sanitizer effectiveness
Total Alkalinity 80 - 120 ppm corrosive to heat exchanger,
large fluctuations in pH scaling of heat exchanger
Calcium Hardness 200 - 400 ppm corrosive to heat exchanger scaling of heat exchanger
Salt 2700 - 3400 ppm poor salt chlorinator performance corrosive to heat exchanger
hazy water, algea growth,
bacteria causing infections
swimmer irritation, bleaching of clothes/hair,
corrosive to heat exchanger

Pomona, CA Clemmons, NC Nashville,TN
Tel: 908-351-5400 www.haywardpool.com
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
9
WARNING:Ifyousmellgasintheapplianceareaorneartheoor(PROPANEIS
HEAVIERTHANAIRANDHENCESETTLESONTHEFLOOR),stopandfollow
theinstructionsonthefrontcoverofthismanual.Sincepropanecanaccumulateincon-
nedareas,extracareshouldbetakenwhenlightingpropaneheaters.
ATTENTION:Donotusetheheaterbelow40°F(4°C)temperaturewithoutadequatetemperatureprotection.
WARNING:Donotingestalcoholordrugsduringuseorpriortousingpool,spa,orhottub.Ingestionofsuch
intoxicantscancausedrowsiness,whichcanleadtounconsciousness,andsubsequentlyresultindrowning.
4. CHLORINATOR INSTALLATION
Chlorinatorsmustbeinstalleddownstreamoftheheater,andacheckvalvemustbeinstalledbetweenthe
heaterandchlorinatortopreventhighchemicalconcentrationsfrombackowingintotheheater.Makesureyour
pipingarrangementmeetsthechlorinatorinstallationrequirementsshownintheinstallationmanualonpage26.
5. BYPASS
Untilwaterchemistryisproperlybalanced,andifyourpipinghasabypassvalveinstalledfortheheater,
openthebypasssothatcorrosiveandpotentiallydamagingwaterwillnotowthroughtheheaterandthere-
foretheheatexchanger.Closethebypassvalveoncethewaterisproperlybalanced.Failuretoclosethe
bypassvalvewhenattemptingtooperatetheheaterwillresultinextensivedamagetotheheatexchanger.
Ensurewaterowthroughtheheaterisrestoredbeforeoperatingtheheater.Abypassfeatureisalsoadvanta-
geousforserviceneedsandfortheabilitytoremovetheheaterfromthewaterpathwhennotheating.Refer
topage25intheinstallationmanualforfurtherinformation.
HEATER OPERATION:
Fulllightingandshutdowninstructionsareincludedonthelighting&operatinginstructionslabelafxed
totheinsideofthefrontaccesspanel.SeeFigure2forthelocationofthislabelandthekeypad.SeeFigure3
forthelabel.
Lighting&shutdown
labelislocatedonthe
insideofthefront
accesspanel
Removethese(4)screwsto
removethefrontaccesspane
Keypad
Figure2:Keypadandlabellocations

Pomona, CA Clemmons, NC Nashville,TN
Tel: 908-351-5400 www.haywardpool.com
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
10
Figure3:Lighting&OperatingInstructionslabel

Pomona, CA Clemmons, NC Nashville,TN
Tel: 908-351-5400 www.haywardpool.com
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
11
KEYPAD INPUTS
Thecontrolacceptsuserinputsviathekeypadonthefrontpanel.
1. Whenchangingthemodefrom“STANDBY”toeither“SPA”or“POOL”theremaybeuptoa10-
seconddelayfortheblowerfantobeginrunning.Thecontrolperformsaninternalself-testandthen
veriesthattheblowervacuumswitchcontactsareopenbeforeenergizingtheblower.
2. Itisnormalfortheheatertodisplaya1-to2-seconddelayinrespondingtoanykeypadinput.
3. Itisnormalfortheheatertodisplayuptoa5-seconddelaywhenthekeypadisusedtoresetthecon-
troltoclearanerrorcode.
4. Thecontrolwillacceptamodechangeduringlockoutafter5seconds.Thecontrolwillcontinueto
displaytheerrorcodeandremaininlockoutuntilitisreset.Atresetthecontrolwillgotothelast
savedmode.
OPERATION: SET POINT ADJUSTMENT:
Thesetpointtemperatureisdisplayedbypressingthe“UP”or“DOWN”buttonswhilein“POOL”or
“SPA”mode.Thesetpointwillblinkwhileitisdisplayed.Furtherpressingofthe“UP”or“DOWN”buttons
willadjustthesetpointtemperatureupordownasdesired.Thesetpointrangeisbetween65°F(18°C)and
104°F(40°C).
FAHRENHEIT VERSUS CELSIUS:
ThetemperaturecanbedisplayedinFahrenheitorCelsius.TOchangethedisplay,usethe“MODE”but-
tontoplacetheheaterin“STANDBY”.Thenpressandholdthe“UP”and“MODE”buttonsuntilthedisplay
showsthe°F/°Cselection.Pressthe“DOWN”buttontotogglebetweenselections.Toaccepttheselection,
pressthe“MODE”button.Iftheuserdoesnotact,theselectionwillbeautomaticallyacceptedafter60sec-
onds.
WINTERIZATION:
Inmoderateclimates,theheatercancontinuetooperateduringshort-termcoldspells.Donotusethe
heatertomaintainthewatertemperaturejustabovefreezingorforfreezeprotection.Caremustbetakento
avoidfreeze-upintheheater.Whenitisusedduringfreezingweather,thepumpmustruncontinuously.The
heaterisnotwarrantedagainstfreeze-ups.Inregionswherefreezingtemperaturesareencountered,allwater
mustbedrainedfromtheheaterwhenitisoutofservice,topreventdamagetotheheaterandpiping.Drain-
ingtheheatexchangerisrecommendedaspartoftheseason’sshutdownprocedures.
Figure4:Keypad KeypadImput

12
SPRING START-UP – CONSULT A PROFESSIONAL:
1. Inspectandcleantheheater,beingsuretheheaterisfreeofleavesanddebrispriortostartup.
2. Besureinletandoutletpipingareproperlyattachedtotheheaterandthedrainvalveisclosed.
3. Turntheltrationsystempump“ON”andallowthesystemtorunlongenoughtopurgealltheair
fromthelines.
4. Turnthegassupplytotheheater“ON”.
5. Setthetemperaturecontrolusingthekeypadto“POOL”or“SPA”andadjustthesetpointtothe
desiredtemperaturesetting.
6. Ifoperatingdifcultiesareencountered,contactaqualiedservicecompanyforassistance.
ERROR CODES:
Figure5liststheerrorcodesthatmaybedisplayedontheheaterdisplayboard.
Contactaqualiedservicecompanyforassistance.
Code Description Information
bD Internalfault/power-up
error
Oninitialtrialforignition.Automaticresetisimmediateoncethegasvalve
relaycheckresultsareacceptable.
bD
Gasvalvesensed
as“ON”error
Ifvalveisopenwhenitshouldbeclosedtheheaterwillshutdownandgointo
lockout.Blowerwilloperateuntilerrorconditioniscorrected.Automaticrestart
2minutesaftererroriscorrected.
bD
Gasvalvesensed
as“OFF”error
Ifvalveisclosedbutameissensedtheblowerwillrunfor5sthenstartanew
ignitionsequence.Iferroroccurs10timesduringacallforheatthecontrolwill
gointolockout.Automaticresetis60minutes.
bD Dataretrievalerror Ifcontrolinputdataiscorruptedtheheaterwillshutdownandgointolockout.
HF
Flamepresentwithgas
valve“OFF”error
Ifameissensedwiththegasvalveoffthecontrolwillgointolockout.The
blowerwillrununtilerrorconditioniscorrected.Whencorrected,controlwill
runblowerfor5sthenautomaticallyrestartafter2minutes.
PF Electricalsupplywiring
error
Thiscodewilldisplayif120Vpolarityisreversed,lowvoltageisdetected,orif
thegroundpathisnotsufcient.Resetisimmediateaftererroriscorrected.
AO
Proverswitch
openerror
Iftheblowerproverswitchdoesnotcloseaftertheblowerstartsthecontrolwill
stoptheignitiontrialgointolockout.Theblowerwillcontinuetorun.Automat-
icresetisimmediateaftertheswitchcloses.
AO
Proverswitchopen
whenexpectedclosed
error
Iftheblowerproverswitchopensunexpectedlyduringoperationthecontrolwill
shutdownandattempttore-light.Iftheswitchdoesnotcloseaftertheblower
startsthecontrolwillgointolockoutwiththeblowerrunning.Automaticresetis
immediateaftererroriscorrected.
Figure5:ERROR CODES

Pomona, CA Clemmons, NC Nashville,TN
Tel: 908-351-5400 www.haywardpool.com
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
13
AO
Proverswitchopendur-
ingpost-purgeerror
Iftheblowerproverswitchopensduringthepost-purgecycle(heaterisnotr-
ing)thecontrolwilldisplaytheerrorcode.Thepost-purgecyclewillbecom-
pletedoncetheblowerproverswitchcloses.
AC
Proverswitchclosed
whenexpectedopen
error
Iftheblowerproverswitchisclosedbeforeblowerstart-upthecontrolwillnot
starttheblower.Automaticresetisimmediatewhentheswitchopens.
IO
Igniteropenerror Ifthecontrolisnotinlockoutandsensesthattheignitercircuitisopenwhen
theblowerisrunningthecontrolwillturnofftheblowerandgointolockout.
Automaticrestart2min.aftererroriscorrected.
SF
Thermistorerror Anexcessivetemperaturedifferencebetweenthetwothermistors(5°Formore)
oran“outofbounds”conditiononbothsensors(lessthan10°Forgreaterthan
180°F)willresultintheerrorcode.Automaticrestartis2minutesaftertheerror
iscorrected.
HS Excessivewater
temperatureerror
Ifwatertemperatureexceeds105°Ftheheaterwillshutdownandgointolock-
out.Automaticrestartis2minutesafterwatertemp.dropsbelow105°F.
HE
Rapidwater
temperaturerise
Ifwatertemperaturerisestoorapidlytheheaterwillshutdownandgointolock-
out.Automaticrestartisafter2minutes.Afterthethirdoccurrenceinthesame
callforheattheheaterwilllockout.
Sb
Keypadbuttonstuck
closederror
Ifoneofthekeypadbuttonsisclosed(orpressed)formorethan30stheerror
codewillbedisplayedbutthecontrolwillcontinuetofunction.Theerrorcode
willbeclearedwhentheconditioniscorrected.
IF Ignitionfailureerror Ifthecontrolexceedsthemaximumnumberofignitionretriesorrecyclesthe
heaterwillshutdownandgointolockout.Automaticresetis60minutes.
CE
Communicationerror Ifcommunicationbetweentheignitionboardandthedisplayboardisnotestab-
lishedwithin3sofpower-upanerrorwillbedisplayed.Aftercommunicationis
established,ifitislostfor30s,theerrorwillbedisplayed.Theerrorcodewill
becleareduponavaliddataexchangebetweenboards.
LO
Limitstringopenerror Ifthelimitstringopenstheheatershutsdownandgoesintolockout.Automatic
restartis2minutesaftertheerrorconditioniscorrectedandthelimitstring
closes.
EE EEPROMerror Anerrorwasdetectedintheignitioncontrolcircuitboard.
Figure5:ERROR CODES(continued)

Pomona, CA Clemmons, NC Nashville,TN
Tel: 908-351-5400 www.haywardpool.com
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
14 HAYWARD POOL HEATER CERTIFICATE OF LIMITED WARRANTY
Limitedheaterwarranty:
TERMSANDCOVERAGE:Wewarrantourpoolheatertobefreefromdefectsinworkmanshipandmateri-
alsundernormaluseandservice.PursuanttothiswarrantyandsubjecttotheConditionsand
Exceptionsindicatedbelow:
1.Wewillreplace(costoffreight,installation,costoffuel,andservicelaboratuser’sexpense)with
theprevailingcomparablemodel,or,atouroption,repairanypool/spaheaterthatleaksundernor-
maluseandservicewithinoneyearfromthedateoforiginalinstallationforallusers.
2.Inaddition,wewillreplace(costoffreight,installation,costoffuel,andservicelaboratuser’s
expense)or,atouroption,repairanypartorpartsofthepool/spaheaterwhichmalfunctionsunder
normaluseandservicewithinoneyearfromthedateoforiginalinstallationforallusers.
LIMITATION ON IMPLIED WARRANTIES:WEARENOTLIABLEFORANYCONSEQUENTIAL
DAMAGESFORBREACHOFANYWRITTENORIMPLIEDWARRANTYOFTHISPRODUCT.Im-
pliedwarranties,includingtheWARRANTYofMERCHANTABILITYandallotherimpliedwarrantiesthat
mayarisefromcourseofdealingorusageoftradeimposedonthesaleofthisheaterunderlawsofthestate
arelimitedindurationtothetermofone(1)yearforallusers.Therearenowarrantieswhichextendbeyond
thedescriptiononthefacehereof.Weshallnotinanyeventbeheldliableforanyspecial,indirect,orconse-
quentialdamages.
EXPENSE OF DELIVERY AND INSTALLATION:
Eachpoolheaterorreplacementparttobefurnishedunderthiswarrantyshallbefurnishedatournearest
distributioncenter.Weshallnotpay,norberesponsibleforshippingordeliverychargestotheplaceofinstal-
lation,norforlaborchargesorothercostsofremovalorinstallation.Everydefectiveheaterorpartreplaced
underthiswarrantyshallbecomeourproperty,andassuch,mustbereturnedtoourdistributioncenterwith
transportationchargespaidbytheuser.Anyreplacementpoolheaterfurnishedunderthiswarrantyshallre-
maininwarrantyonlyfortheunexpiredportionofthiswarranty.
CONDITIONS AND EXCEPTIONS:
Thiswarrantyappliesonlytothepool/spaatitsoriginalplaceofinstallationandonlyfortheoriginal
owner.Itdoesnotapplyifthepoolheaterisinstalledinviolationofanyapplicablecodeorordinance,oris
notinstalled,operatedandmaintainedinaccordancewithourinstructions,orismisused,damagedbyac-
cident,weather,actofGod,freezing,watervoidand/orexcesspressure,alteredordisconnected.Itdoesnot
applywithrespectto:
1.AheaternotequippedwithCertiedC.S.A.limitcontrolsorequivalentpressurereliefvalve.
2.Aheateroperatedwithsettingsinexcessof,and/orwithfuelnotconformingtothoseshownonrat-
ingplate;
3.Aheateronwhichtheserialnumbershavebeenaltered,defaced,orremoved.
4.Leaksarisingfromdefectiveinstallation;
5.Productionofnoise,odors,ordiscolored(rusty,etc.)water;
6.Leakagesubstantiallycontributedtobysediment,limeprecipitateand/orhigherthannormaldis-
solvedsolids(pHabove7.8)inthetank,coppertubes,orwaterways;
7.Leakagecausedsubstantiallycontributedtobycorrosiveelementsintheatmosphere(suchasthe
storageofchlorineorotherchemicals);
8.Leakagecausedsubstantiallyorcontributedtobycorrosivepoolwaterinanacidcondition(pH
below7.2);
9.Damagecausedsubstantiallyorcontributedtobyanexternalsourceofenergy;
10.Apool/spaheaterisawatercontainingdevice.Leakageofwaterfromthisdevicecanbeexpected
atsometimeduetomalfunctionorthelimitations

Pomona, CA Clemmons, NC Nashville,TN
Tel: 908-351-5400 www.haywardpool.com
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
15
oftheservicelifeofvariouscomponents.Donotinstallthisproductwheresuchleakagecancausedamage.
MANUFACTURERISNOTRESPONSIBLEORLIABLEFORANYCOSTSINCURREDBYSUCH
DAMAGE.
IN NO CASE ARE WE TO BE HELD LIABLE FOR DAMAGE
TO SURROUNDING AREA OR PROPERTY
CAUSED BY LEAKAGE OR MALFUNCTION.
HOW TO CLAIM UNDER THIS WARRANTY:
Theoriginalowner,upondiscoveringthedefect,mustpresenttheattachedcompletedwarrantyclaimcard
withproofofpurchaseeithertothedealerornotifytheCompanyinwritingateitheraddress:
HAYWARD POOL PRODUCTS, INC.
620 DIVISION ST.
ELIZABETH, NJ 07207
OR
HAYWARD POOL PRODUCTS, INC.
2875 POMONA BOULEVARD
POMONA, CA 91768
Uponreceiptofsuchnoticationweshalldecidewhethertorepairsuchpartsorreplaceanypoolheater,
reservingatalltimestherighttoinspectinordertoverifyanyclaimeddefect.Wealsoreservetherightto
haveourrepresentativesmakeanyinspections,repairs,ortofurnishreplacements.Thiswarrantyisintended
asalegallybindingobligationoftheCompany,enforceableinthecourts.Thiswarrantymaygiveyouspe-
ciclegalrightswhichmayvaryfromstatetostate.
LIMITATION ON LIABILITY:
Allintendedrepresentationshavebeenexpresslysetforthinthisdocument.Thiswarrantymaynotbe
extendedbyoraloranyotheradditionalrepresentations,writtensalesinformation,drawings,orothermal-
function,isstrictlylimitedtorepairorreplacementofthedefectiveheaterorpart,asprovidedhereinand
theCompanyisnotresponsiblehereunderforincidentalorconsequentialorincidentalcostsordamages.
Thecompanyneitherassumes,norauthorizesanypersonorrmtoassumeforus,anyfurtherliabilityor
obligationinconnectionwiththesale,installation,use,maintenance,orexistenceoftheheater.SAFETY
WARNING:Poolheatersareheatproducingappliancesandtoavoiddamageorinjuryintheeventofpos-
sibleoverheatingoftheouterjacket(1)nomaterialsshouldbestoredagainstthejacketand(2)careshould
betakentoavoidunnecessarycontact(especiallybychildren)withthejacket.Whenlightingagasheater,the
lightinginstructionsmustbefollowedexactlytoprevent“ashback”ofexcessgasintheheater.Electronic
ignitionheatersandelectricheatersmusthavethepowershutoffwhenmakingadjustmentsto,servicing,or
comingintocontactwiththeheater.UNDERNOCIRCUMSTANCESSHOULDFLAMMABLEMATERI-
ALS,SUCHASGASOLINEORPAINTTHINNERS,BEUSEDORSTOREDINTHEVICINITYOFTHE
HEATERORINANYLOCATIONFROMWHICHFUMESCOULDREACHTHEHEATER.Foryour
comfort,enjoymentandsafety,pleasereadtheenclosedoperatinginstructionscarefully.

Hayward Pool Products, Inc.
620 Division St.
Elizabeth, NJ 07207
Hayward Pool Products, Inc.
2875 Pomona Boulevard
Pomona, CA 91768
Hayward Pool Products, Inc.
2880 Plymouth Drive
Oakville, Ontario L6H 5R4
Hayward S.A.
Zoming de Jumet
B6040 Jumet, Belgique
© 2004 Hayward Imprimé aux U.S.A.
Other manuals for Universal H-Series Low NOx
2
This manual suits for next models
6
Table of contents
Other Hayward Heater manuals

Hayward
Hayward HC Series User manual

Hayward
Hayward H250FDN User manual

Hayward
Hayward C-SPA-XI 5.5 User manual

Hayward
Hayward Universal H-Series Low NOx User manual

Hayward
Hayward H150FDN User manual

Hayward
Hayward ED2 Administrator guide

Hayward
Hayward H135ID User manual

Hayward
Hayward H150FDAU User manual