9
Use Only Genuine Hayward Replacement Parts.
W
Wa
ar
rn
ni
in
ng
g-
-R
Ri
is
sk
ko
of
fI
In
nj
ju
ur
ry
y
The Filtration and Booster Pumps must be O
OF
FF
Fwhen connecting
or disconnecting cleaner hose.
C
Ca
au
ut
ti
io
on
n-
-R
Ri
is
sk
ko
of
fE
Eq
qu
ui
ip
pm
me
en
nt
tD
Da
am
ma
ag
ge
e
The filter pump must always be run to clear air from the system
before turning the Booster Pump O
ON
N.
.N
Ne
ev
ve
er
rr
ru
un
nthe Booster
Pump without the main filter pump O
ON
N. Running the Booster
Pump dry will damage the Booster Pump and void the warranty.
O
Op
pe
er
ra
at
ti
in
ng
gt
th
he
eP
Ph
ha
an
nt
to
om
mT
Tu
ur
rb
bo
oC
Cl
le
ea
an
ne
er
r
1
1.
.Be sure all filtration system valves are open and supplying
water to the Booster Pump.
2
2.
.Be sure valves to and from the Booster Pump and dedicated
return line are fully opened.
3
3.
.The Phantom Turbo Cleaner and its Booster Pump can only
operate when the pool’s filter pump is operating.
C
Ca
au
ut
ti
io
on
n-
-R
Ri
is
sk
ko
of
fE
Eq
qu
ui
ip
pm
me
en
nt
tD
Da
am
ma
ag
ge
e
Failure to open valves fully and/or failure to have the filtration
system operating will damage the Booster Pump. This damage
voids the Booster Pump’s warranty.
S
Se
et
tt
ti
in
ng
gP
Pr
re
es
ss
su
ur
re
e
I
Im
mp
po
or
rt
ta
an
nt
t:
:The cleaner will not operate properly if the pressure
is not properly set. Too little pressure will prevent proper
movement and cleaning. Too much pressure will cause poor
cleaning and premature wear of Cleaner parts.
W
Wa
ar
rn
ni
in
ng
g-
-R
Ri
is
sk
ko
of
fI
In
nj
ju
ur
ry
y
Be careful to hold the Cleaner Connector (Part C) with the Setup
Pressure Gauge (Part U) attached under water and not to be
sprayed by the hole in the Setup Pressure Gauge or by the
Sweep Hose. N
Ne
ev
ve
er
rpoint a jet or hose at people or pets.
Clip the Setup Pressure Gauge to the hose near the Wall Quick
Connect.
1
1.
.Turn the filtration system pump O
ON
Nthen the Booster Pump
O
ON
N. Read the pressure on the Setup Pressure Gauge
connected to the Cleaner Connector.Use a flat blade
screwdriver to adjust the Wall Quick Connect Knob
(see figure 2) until the pressure reads 25 PSI (+/- 5 PSI).
N
No
ot
te
e:
:The Wall Quick Connect can be adjusted from “0”
(fully closed) to “5” (fully open). Do N
NO
OT
Tforce the
adjustment knob beyond “0” or “5”.
2
2.
.If the Wall Connector is on Position “5” (fully open) and the
pressure is still below 20 PSI, check for clogged Filter, Pump
Strainer Basket, Main Drain, Skimmer Basket, etc., to
determine why there is insufficient water pressure at the
dedicated line. If more pressure is still required have an
Authorized Hayward Pool Dealer or Service person check
the Booster Pump, Filtration System and Plumbing to
determine if they are functioning correctly.
3
3.
.Turn the Booster Pump and Filtration Pump O
OF
FF
F.
4
4.
.R
Re
em
mo
ov
ve
et
th
he
eS
Se
et
tu
up
pP
Pr
re
es
ss
su
ur
re
eG
Ga
au
ug
ge
efrom the Cleaner
Connector. Store the Setup Pressure Gauge with the
Owner’s Guide in a safe place.
5
5.
.Attach the Cleaner Connector to Cleaner. The Sweep Hose
should be directly below the Pressure Hose.
6
6.
.Place the cleaner in the pool, turn the Filtration system O
ON
N,
then turn the Booster Pump O
ON
N.
C
Co
on
nn
ne
ec
ct
ti
in
ng
gP
Pr
re
es
ss
su
ur
re
eH
Ho
os
se
et
to
oC
Cl
le
ea
an
ne
er
r
A
Ad
dj
ju
us
st
ti
in
ng
gP
Pr
re
es
ss
su
ur
re
ea
at
tW
Wa
al
ll
lC
Co
on
nn
ne
ec
ct
to
or
r
S
Se
et
tu
up
pP
Pr
re
es
ss
su
ur
re
eG
Ga
au
ug
ge
e&
&W
Wa
al
ll
lC
Co
on
nn
ne
ec
ct
t
K
C
U
C
7
7.
.Lubricate the swivel on the 3 ft. Hose Wall End Assembly (Part T)
in soapy water then snap into one of the Pipe Assemblies.
8
8.
.Lubricate the swivel on the Hose Cleaner End Assembly (Part S)
in soapy water then snap into a different Pipe Assembly.
9
9.
.Open Bag #2 and lubricate both ends of the Hose Swivel
Assemblies (Part R) in soapy water. Connect the Pipe
Assemblies by snapping the Hose Swivel Assemblies into each
of the Pipe Assemblies.
C
Co
on
nn
ne
ec
ct
ti
in
ng
gH
Ho
os
se
et
to
oW
Wa
al
ll
lF
Fi
it
tt
ti
in
ng
g
1
1.
.With the Booster Pump and Filtration system turned O
OF
FF
F,
look down from the pool deck and hold the Wall Quick
Connect so the hose is to the left and the adjustment knob
is to the right. Insert the Wall Quick Connect into the
Universal Wall Fitting and turn it to the left (counter
clockwise) to lock. The hose should be on the bottom below
the adjustment knob.
2
2.
.Pull the Wall Quick Connect outward to check that the Wall
Quick Connect is locked into the Universal Wall Fitting.
3
3.
.To d
di
is
sc
co
on
nn
ne
ec
ct
tthe hose, first turn the Booster Pump and
Filtration pump O
OF
FF
Fthen push the Wall Quick Connect
toward the wall, turn it to the right (clockwise) and pull the
Wall Quick Connect out of the Universal Wall Fitting.
D
Di
is
sc
co
on
nn
ne
ec
ct
ti
in
ng
ga
aH
Ho
os
se
eP
Pi
ip
pe
e
If it is necessary to shorten, lengthen or replace a component
of the Rigid Pressure Hose, the Snap Fits can be undone with
two small screwdrivers.
8
Use Only Genuine Hayward Replacement Parts.
W
Wa
al
ll
lQ
Qu
ui
ic
ck
kC
Co
on
nn
ne
ec
ct
t
C
Co
on
nn
ne
ec
ct
ti
in
ng
gT
Th
he
eR
Ri
ig
gi
id
dP
Pr
re
es
ss
su
ur
re
eH
Ho
os
se
et
to
oP
Po
oo
ol
lO
Op
pe
er
ra
at
ti
in
ng
gt
th
he
eP
Ph
ha
an
nt
to
om
mT
Tu
ur
rb
bo
oC
Cl
le
ea
an
ne
er
r
W
Wa
al
ll
lC
Co
on
nn
ne
ec
ct
to
or
rA
As
ss
se
em
mb
bl
ly
y
H
Ho
os
se
eC
Cl
le
ea
an
ne
er
rE
En
nd
dA
As
ss
se
em
mb
bl
ly
y
T QN
H
Ho
os
se
eS
Sw
wi
iv
ve
el
lA
As
ss
se
em
mb
bl
ly
y
RN
R
Ri
ig
gi
id
dP
Pr
re
es
ss
su
ur
re
eH
Ho
os
se
eA
As
ss
se
em
mb
bl
ly
y
S
Figure 1
Figure 2
Figure 3
I
It
ti
is
se
es
ss
se
en
nt
ti
ia
al
lt
th
ha
at
tt
th
he
eH
Ho
os
se
eS
Sw
wi
iv
ve
el
lA
As
ss
se
em
mb
bl
li
ie
es
sa
ar
re
e
i
in
ns
st
ta
al
ll
le
ed
dc
co
or
rr
re
ec
ct
tl
ly
yt
to
oe
en
ns
su
ur
re
et
ta
an
ng
gl
le
ef
fr
re
ee
eo
op
pe
er
ra
at
ti
io
on
no
of
ft
th
he
e
P
Ph
ha
an
nt
to
om
mT
Tu
ur
rb
bo
o.
.