PRX Battery Replacement Instructions, V3a
12/09/19
5. Replace the battery with the new one supplied in the kit.
The battery has a polarized locking connector and can
only be plugged in one way (Figure 4). Make sure the
connector snaps into place on the board.
6. After the battery has been replaced, remove the backing
from the tape on the battery, close the chassis and slide
it back into the housing. Be careful when closing the
chassis so the two standoffs remain in the upright
position.
7. Insert the screws so they are flush with the housing –do
not overtighten. Place the switch plungers into the
housing in the locations they were removed from (Figure
5).
8. Test the PRX by pressing the ON/OFF button and
verifying that the PRX turns on all voltage range lights one
at a time from the lowest range to the highest, returns to
the lowest range and then turns on the voltage indicating
lights and beeper. If the PRX stays on following this test it
has passed the self-test. If the PRX test is not successful,
check to make sure the battery is installed correctly (see
Step 5). If the PRX test is still unsuccessful, charge the
battery and perform the test again. If the self-test
continues to be unsuccessful, contact HDE.
9. Remove the paper liner from the back of the new overlay
(including the switch plunger locations) and place the overlay
onto the housing of the PRX (Figure 6). Once it is aligned,
press it into place to secure the overlay onto the housing.
10.Before using the PRX the new battery should be charged
(Figure 7). Charge the PRX using the charger cord. Charge
is indicated on the face of the unit by the voltage range lights
turning on in sequence. A full charge can take up to three
hours. When the charge is complete only the highest voltage
range light will remain on. After three hours, this light will turn
off. The PRX battery cannot be overcharged.
If there are any questions regarding the PRX battery replacement procedure, please contact HD
Electric.