ASSEMBLY INSTRUCTIONS FOR
Lock & Locate™Boxes (#18671 & 18676)
1
Step 1. Clean surface and peel the protective
backing from the Receiving Base.
2
3 4
Step 2. Place the Receiving Base in the Wall Mount
or on countertop, cart top or shelves.
Step 3. Press firmly for several seconds to attach the
Receiving Base.
Step 4. Loosely drive the screw into the desired
location on the wall or cabinet. (Screws are not
provided.)

Call Free 1.800.848.1633 • Fax Free 1.800.447.2923
Web: www.GoHCL.com • Email: [email protected]
© Health Care Logistics, Inc. 2011
ASSEMBLY INSTRUCTIONS FOR
Lock & Locate™Boxes (#18671 & 18676)
6
Step 6. Once level, tighten screws into the
remaining holes.
78
9
Step 7. Push the locking box onto the Receiving
Base. Continue pushing until the locking box clicks
into place.
Step 8. Unlock the box.
Step 9. Pull up of the white button in the middle of
the locking box. While pulling up on the button, pull
the entire box forward off of the Receiving Base.
5
Step 5. Place a level on top of the Wall Mount.

Call Free: 1.800.848.1633 • Fax Free: 1.800.447.2923
Web: GoHCL.com • Email: [email protected]
© Health Care Logistics, Inc. 2014
INSTRUCTIONS FOR
KEDL Lock
The KEDL is offered in two versions:
Manual Lock and Self Lock. Contents will vary depending on the
version.
Contents – Manual Lock Version:
Manual KEDL Assembly
2 AAA alkaline batteries
1 Offset locking cam / 1 Straight locking cam
FlexaCam adapters
Mounting hardware
Contents – Self Lock Version:
Self Locking KEDL assembly featuring SlamCAM
2 AAA alkaline batteries
SlamCAM spacer discs
Mounting hardware
Each lock contains 2 green stickers that are needed for resetting
KEDL. In the event KEDL needs reset, one green sticker is placed
on the back of the device. The remaining green sticker should
be saved in a safe and secure location for future reference. HCL
keeps no record of this.
Care and Cleaning
To clean the KEDL surface, apply non-acid based cleaner to a
clean cotton cloth; do not spray cleaner directly on the KEDL.
Wipe down keypad and its respective housing surfaces of excess
cleaner.
Powering Up and Battery Installation
KEDL is shipped with two AAA batteries. While KEDL
features a low battery indicator, annual battery replacement is
recommended. Mixing batteries of different chemistries could
damage the KEDL resulting
in lock failure.
To power up KEDL, remove the red tag. Lock is now ready for
use.
A Phillips head screw driver will be required to remove the
battery cover. (Not Included)
To change batteries:
1. Loosen the retaining screw.
2. Remove battery cover.
3. Press CLEAR 5 times.
4. Insert new batteries as
shown in the illustration.
5. Reinstall battery cover,
tighten retaining screw.
RegulatoR, Keyless Locking 4
Powering Up and Battery Installation
CompX RegulatoR is shipped with two AAA batteries. While RegulatoR
features a low battery indicator, annual battery replacement is recommended.
Mixing batteries of different chemistries could damage the RegulatoR resulting
in lock failure.
To power up RegulatoR, remove the red tag. Lock is now ready for use.
A T-15 pin in head Torx
®
(6-lobe) will be required to remove the battery cover.
(Not Included)
To change batteries:
1. Loosen the retaining
screw.
2. Remove battery cover.
3. Press CLEAR 5 times.
4. Insert new batteries as
shown in the illustration.
5. Reinstall battery cover,
tighten retaining screw.
RegulatoR, Keyless Locking 13
Programming Security Timeout ON / Security Timeout OFF
Warning: Security Timeout ON will disable the RegulatoR from use for 5
minutes when 5 invalid attempts to unlock RegulatoR occur. During this time,
RegulatoR will not unlock with either the valid user or supervisor code.
To change the RegulatoR to Security Timeout ON or OFF, follow the steps on
page 8 to enter programming mode.
There is a 10 second programming time limit between each step. If RegulatoR
times out or error is made, programming will end and you will need to enter
programming mode again.
1. Place RegulatoR into programming mode see page 8).
a. To turn Security Timeout ON, type 11 and then press
ENTER.
OR
b. To turn Security Timeout OFF, type 10 and then press
ENTER.
2. If successful, the green indicator light will illuminate for 1 second.
Continue programming or press 9 and then ENTER to exit programming.
Programming – Introduction
KEDL is easy to program and operate. Type the user code
(factory default 1234) and press ENTER to lock or unlock the
cabinet.
The supervisor can change operating codes, modes and restore
lock settings. While KEDL is easy to program, we highly
recommend reading the complete programming instructions
prior to making any changes. Remember to keep track of any
programming changes.
Button locations, indicator lights and knob referenced in the
programming instructions are shown below.
RegulatoR, Keyless Locking 12
Programming Single Use Timeout ON / Single Use Timeout OFF
Warning: Manual Lock - Single Use Timeout ON is a feature to prevent users
from occupying a shared use locker or cabinet for a prolonged period of time.
Turning this feature on will disable the user code after a programmable amount
of time. After this time elapses, RegulatoR and can only be opened with the
supervisor code.
To change the RegulatoR to Single Use Timeout ON or OFF, follow the steps
on page 8 to enter programming mode.
There is a 10 second programming time limit between each step. If RegulatoR
times out or an error is made, programming will end and you will need to enter
programming mode again.
1. Place RegulatoR into programming mode (see page 8).
a. To set Timeout ON, type 2XX and then press ENTER.
(XX represents a time period from 04 - 12 in whole hours.)
OR
b. To turn Timeout OFF, type 20 and then press ENTER.
3. If successful, the green indicator light will illuminate for 1 second.
Continue programming or press 9 and then ENTER to exit programming.
RegulatoR, Keyless Locking 5
Programming – Introduction
CompX RegulatoR is easy to program and operate. Type the user code (factory
default 1234) and press ENTER to lock or unlock the cabinet.
The supervisor can change operating codes, modes and restore lock settings.
While RegulatoR is easy to program, we highly recommend reading the
complete programming instructions prior to making any changes. Remember to
keep track of any programming changes.
Button locations, indicator lights and knob referenced in the programming
instructions are shown below.
CLEAR button erases any key input made in error
Indicator Lights
Green – Indicates button
input and valid code
Yellow - Indicates low
battery or program mode.
Red – Indicates incorrect
entry
Knob is always rotated
clockwise to unlock ENTER button is used to complete code
and counter clockwise to lock and begin programming

Call Free: 1.800.848.1633 • Fax Free: 1.800.447.2923
Web: GoHCL.com • Email: [email protected]
© Health Care Logistics, Inc. 2014
INSTRUCTIONS FOR
KEDL Lock
KEDL is offered with Self Lock featuring SlamCAM. If your lock
is the Self Lock version, follow the directions below to unlock
and lock the KEDL:
The KEDL is offered in a Manual Lock version. If your lock is the
Manual Lock version follow the directions below to unlock and
lock the KEDL.
KEDL Programming Mode
To enter programming mode you must know the supervisor
code. The default supervisor code is 12345. Once in
programming mode, multiple changes can be made prior to
exiting programming.
There is a 10 second programming time limit between each step.
If KEDL times out or an error is made, programming will end
and you will need to enter programming mode again.
1. Lock must be in the locked position prior to entering
programming mode.
2. Type supervisor code and press ENTER.
3. Turn knob clockwise 90° to the unlocked position and press
and hold ENTER for 3 seconds (yellow indicator light will
illuminate).
· If product is Self Lock with the SlamCAM feature you can now
let go of the knob.
4. With the yellow indicator light illuminated, programming can
begin.
Changing the User Code
To change the user code, follow the steps on page 8 to enter
programming mode.
The factory default user code is 1234 (User codes must be 4 to 8
digits in length.)
There is a 10 second programming time limit between each step.
If KEDL times out or an error is made, programming will end
and you will need to enter programming mode again.
1. Place KEDL into programming mode (see page 8).
2. Press 1 and then press ENTER.
3. Type the current user code and press ENTER.
4. Type the new user code and press ENTER.
5. Retype the new user code and press ENTER.
6. If successful, the green indicator light will illuminate for 1
second.
Continue programming or press 9 and then ENTER to exit
programming.
RegulatoR, Keyless Locking 6
CompX RegulatoR is offered with Self Lock featuring SlamCAM. If your lock
is the Self Lock version, follow the directions below to unlock and lock the
RegulatoR:
To operate the Self Lock version of RegulatoR:
Type a valid code, press ENTER and rotate knob
clockwise 90°, hold knob until door or drawer is
open. Release knob, RegulatoR knob will return
to the locked position. Door or drawer can be
closed at any time.
RegulatoR, Keyless Locking 11
CompX RegulatoR features several modes of operation. These functions can be
changed using the following instructions with a valid supervisor code.
Programming Single Use Mode / Standard Mode
Single Use Mode allows for a revolving user code so multiple people may use
the lock without having to reprogram the RegulatoR each time.
Note: This mode cannot be used with Self Lock with SlamCAM.
Standard Mode RegulatoR operates with a fixed code. To change the code,
follow the Changing the User Code steps on page 9.
To change the RegulatoR to Single Use or Standard Mode, follow the steps on
page 8 to enter programming mode.
There is a 10 second programming time limit between each step. If RegulatoR
times out or an error is made, programming will end and you will need to enter
programming mode again.
1. Place RegulatoR into programming mode (see page 8).
a. To turn Single Use Mode “ON”: type 51 and then press
ENTER.
OR
b. To return to Standard Mode: type 50 and then press ENTER.
2. If successful, the green indicator light will illuminate for 1 second.
Note: Returning to Standard Mode will reset the factory user default code
(1234).
Continue programming or press 9 and then ENTER to exit programming.
RegulatoR, Keyless Locking 10
Changing the Supervisor Code
To change the supervisor code, follow the steps on page 8 to enter programming
mode.
The factory default supervisor code is 12345 (supervisor codes must be 4 to 8
digits in length.)
There is a 10 second programming time limit between each step. If RegulatoR
times out or an error is made, programming will end and you will need to enter
programming mode again.
1. Place RegulatoR into programming mode (see page 8).
2. Press 2 and then press ENTER.
3. Type the current supervisor code and press ENTER.
4. Type the new supervisor code and press ENTER.
5. Retype the new supervisor code and press ENTER.
6. If successful, the green indicator light will illuminate for 1 second.
Continue programming or press 9 and then ENTER to exit programming.
RegulatoR features a reset code which will restore the default supervisor code
and user code. RegulatoR was shipped with reset stickers; one attached to the
back of the RegulatoR and an extra sticker that should be saved in a safe and
secure location for future reference.
To restore the factory default supervisor and user code, type the Reset Code
assigned to the RegulatoR and press ENTER.
RegulatoR, Keyless Locking 7
CompX RegulatoR is offered in a Manual Lock version. If your lock is the
Manual Lock version follow the directions below to unlock and lock the
RegulatoR.
To operate Manual Lock version of
RegulatoR:
To unlock, type a valid code, press
ENTER and rotate knob clockwise 90°.
To lock, rotate knob 90° counter
clockwise.

Call Free: 1.800.848.1633 • Fax Free: 1.800.447.2923
Web: GoHCL.com • Email: [email protected]
© Health Care Logistics, Inc. 2014
INSTRUCTIONS FOR
KEDL Lock
Changing the Supervisor Code
To change the supervisor code, follow the steps on page 8 to
enter programming mode.
The factory default supervisor code is 12345 (supervisor codes
must be 4 to 8 digits in length.)
There is a 10 second programming time limit between each step.
If KEDL times out or an error is made, programming will end
and you will need to enter programming mode again.
1. Place KEDL into programming mode (see page 8).
2. Press 2 and then press ENTER.
3. Type the current supervisor code and press ENTER.
4. Type the new supervisor code and press ENTER.
5. Retype the new supervisor code and press ENTER.
6. If successful, the green indicator light will illuminate for 1
second.
Continue programming or press 9 and then ENTER to exit
programming.
KEDL features a reset code which will restore the default supervisor
code and user code. KEDL was shipped with reset stickers; one attached
to the back of the KEDL and an extra sticker that should be saved in a
safe and secure location for future reference.
To restore the factory default supervisor and user code, type the Reset
Code assigned to the KEDL and press ENTER.
The KEDL features several modes of operation. These functions
can be changed using the following instructions with a valid
supervisor code.
Programming Single Use Mode / Standard Mode
Single Use Mode allows for a revolving user code so multiple
people may use the lock without having to reprogram the KEDL
each time.
Note: This mode cannot be used with Self Lock with SlamCAM.
Standard Mode KEDL operates with a fixed code. To change the
code, follow the Changing the User Code steps.
There is a 10 second programming time limit between each step.
If KEDL times out or an error is made, programming will end
and you will need to enter programming mode again.
1. Place KEDL into programming mode.
a. To turn Single Use Mode “ON”: type 51 and then press
ENTER. OR
b. To return to Standard Mode: type 50 and then press
ENTER.
2. If successful, the green indicator light will illuminate for 1
second.
Note: Returning to Standard Mode will reset the factory user
default code (1234).
Continue programming or press 9 and then ENTER to exit
programming.
Programming Single Use Timeout ON / Single Use
Timeout OFF
Warning: Manual Lock - Single Use Timeout ON is a feature to
prevent users from occupying a shared use locker or cabinet for a
prolonged period of time. Turning this feature on will disable the
user code after a programmable amount of time. After this time
elapses, KEDL and can only be opened with the supervisor code.
To change the KEDL to Single Use Timeout ON or OFF, follow
the steps to enter programming mode.
There is a 10 second programming time limit between each step.
If KEDL times out or an error is made, programming will end
and you will need to enter programming mode again.
1. Place KEDL into programming mode (see page 8).
a. To set Timeout ON, type 2XX and then press ENTER.
(XX represents a time period from 04 - 12 in whole hours.)
OR
b. To turn Timeout OFF, type 20 and then press ENTER.
3. If successful, the green indicator light will illuminate for 1
second.
Continue programming or press 9 and then ENTER to exit
programming.
Reset User Code to Factory Default 1234
(Does not apply to Single Use Mode)
To reset the User Code to the factory default 1234 follow the
steps to enter programming mode.
There is a 10 second programming time limit between each step.
If KEDL times out or error is made, programming will end and
you will need to enter programming mode again.
1. Place KEDL into programming mode.
2. Type 8888 and then press the ENTER button.
3. If successful, the green indicator light will illuminate for 1
second.
Continue programming or press 9 and then ENTER to exit
programming.

Call Free: 1.800.848.1633 • Fax Free: 1.800.447.2923
Web: GoHCL.com • Email: [email protected]
© Health Care Logistics, Inc. 2014
INSTRUCTIONS FOR
KEDL Lock
RegulatoR, Keyless Locking 2
Thank you for purchasing the CompX RegulatoR. The RegulatoR is an
innovative solution for locking cabinet doors and drawers. It can mount to
cabinet doors or drawers with a material thickness of 1/32” to 1-7/16”.
Powered by 2-AAA batteries (included), RegulatoR operates using a 4 to 8 digit
code. Operation is simple: type a valid code and press ENTER. Then just turn
the lever to the locked or unlocked position.
RegulatoR is easy to install, and offers:
Programmable user and supervisor codes
Programmable modes of operation
Programmable reset features
RegulatoR is intended for interior use only.
Operating Temperature: 50°F – 120°F (10°C – 48°C)
Note: It is strongly recommended that batteries be replaced on an annual basis.
In the event the batteries should die, they can be replaced via the external battery
compartment.