Please, disconnect the Hedler Light Unit from the
power supply when exchanging lamp and/or fuse.
!
HEDLER Systemlicht GmbH Heerstrasse 112 D-65594 Runkel / Lahn www.hedler.com
Telefon + 49 - (0) 6482 918 100 Telefax + 49 - (0) 6482 918 111 eMail info@hedler.com
Halogen HT 19s
HEDLER WARRANTY
All Hedler equipment is fully guaranteed against any material or manufacturing defects for three years after date of purchase. Parts made out of
glass, Tungsten Halogen lamps and Flash bulbs are not covered by this warranty.
MAINTENANCE and REPAIR
Used under normal professional conditions, Hedler Tungsten Lights require no maintenance. If repair is required, please, contact your dealer,
the authorized distributor in your country or the Hedler factory directly. Please note, that a pre-dismantled Light Unit could cause increased
repair costs.
APPROVAL and UL STANDARDS for SAFETY
The Hedler HT 19s Light Unit is SEV Standard tested, sign Schweiz HD 504.
The Hedler HT 19s Light Units does not have the UL (Underwriters Laboratories) Standards for Safety sign for the USA and Canada.
NECESSARY PRECAUTIONS
Never obstruct the Forced Air Cooling (intakes or exhausts) in any way when the Hedler HT 19s is in use. Always keep a minimum distance of
100 cm between the safety glass (or accessories) and any combustible materials when the Hedler HT 19s is in use. Never use the Hedler HT 19s
near any inflammable liquids, gases, materials or explosives that may be ignited by heat or spark. Hedler HT 19s are designed for professional use
and should be used with professional care. The manufacturer will not assume responsibility for damage caused by unprofessional or otherwise
careless use of this equipment.
Please pay attention to the following safety notes:
- Always disconnect the Hedler HT 19s from the power supply before performing any kind of maintenance work on the unit.
- Never use a defective Hedler HT 19s. Never use a Hedler HT 19s with a defective power cord.
- Never use a Hedler HT 19s a defective safety glass. Replace a defective safety glass immediately.
- Always use the Hedler HT 19s in combination with a steady and secure standing light stand. Always work within the
light stand´s load capicity, especially if you are using, or plan to use, large and/or heavy folding reflectors.
- Never use a Hedler HT 19s unattended.
- Never use the Hedler HT 19s outdoors nor in exceptionally humid conditions.
- Never use the Hedler HT 19s for any reason other than photographic or cinematic lighting.
- Always keep the Hedler HT 19s out of reach of children. This is not a toy, the HT 19s is unsuitable for use by children.
LAMPS and FUSES
For replacing the lamp, unscrew the securing screw, pull the clip upward, which is securing the Borofloat™ safety glass and remove the glass.
Make sure that the lamp has cooled off, before pulling it upward and out of the socket. Push the new lamp into the socket, observing instructions
by the lamp manufacturer. Replace the safety glass, push the clip downwards securing Borofloat™ safety glass and thighten the securing screw.
For replacing fuse, use a coin to unsrew the cap of one of the fuse boxes, located left of the main switch on the backside of the Light housing,
by a counter-clockwise turn. Remove the spent fuse and replace it by a new one of the appropriate type. Closing is done by pressing down the
lid and screwing the cap into it´s place by a clockwise turn.
For selecting lamps and fuses, please consult the table below. The Code numbers of lamps and their appropriate fuses are to be found on the
same line. Always use lamps only in combination with their appropriate fuses.
Lamps and Fuses
Tungstenlamps Watts Volt Average life / h Kelvin Fuse Code
U-Type < 0655 > 650 240 50 3300 F 4 A < 1045>
Bulb-Type < 64502 > 150 230 25 3200 F 2 A < 1048 >
< 64515 > 300 230 15 3400 F 2 A < 1048 >
< 64516 > 300 230 75 3200 F 2 A < 1048 >
Lamps and Fuses Combinations
Fuse left Fuse right
3 Bulb-Type lamps á 150 Watts 450 Watts F 2 A F 2 A
3 Bulb-Type lamps á 300 Watts 900 Watts F 2 A F 4 A
3 U-Type lamps á 650 Watts 1950 Watts F 4 A F 8 A
2 Bulb-Type lamps á 300 Watts and 1 U-Type lamp á 650 Watts 1250 Watts F 4 A F 4 A
2 U-Type lamps á 650 Watts and 1 Bulb-Type lamp á 300 Watts 1600 Watts F 2 A F 8 A
HEDLER®