1. Replace the batteries with new ones in time on low battery
condition to ensure normal operation.
2. No block within a radius of 0.5m from the detector.
3.The horizontal distance from the detector to the air
conditioner outlet should not be less than 1.5m.
4. If needs to install the detector in an aisle ceiling with a width
less than 3m, choose a center position. Keep the distance
between the detectors less than 15m. The distance from the
detector to the end wall should not exceed half of the
distance between the detectors.
5. Clean the detector surface with soft brush every month to
ensure sensitivity. Do not spray air-freshers, hair gels,
paints or other aerosols near the detector.
6. Do not use any detergents or solvents to clean the detector.
Chemicals may cause permanent damage or transient
pollution to the sensor.
7. For malfunction problems, contact your dealer. Do not
dismantle and try to repair it privately.
8. The detector can reduce accidents happening, but can not
guarantee a hundred percent safety. For safety consideration,
besides proper usage of the detector, pay attention to build
up safety consciousness and take preventive measures in
daily life.
9. Maintain the detector periodically as per requirements in this
manual.
EMERGENCY ALARM TREATMENTS
NOTES
3. During alarming status, short press the Test & Hush Button.
Then the detector goes into mute status. The LED keeps
flashing red while the buzzer will stop sounding. If the
alarm status hasn’t been reset, the mute status will end
automatically in 10 minutes later. The buzzer sounds again.
If the alarm status is reset during the 10 minutes, the
detector recovers to normal working status.
4. The detector can auto check open circuit, short circuit and
other malfunctions in smoke chamber. During malfunction,
the LED flashes yellow, twice a minute along with buzzer
sounding to warn user.
5. When battery voltage < 2.4V, the detector will give out low
battery signal periodically. The LED flashes yellow, once
every 30s along with buzzer sounding. While the battery
voltage < 2.0V, the LED constant yellow and the detector
will restart in 32s due to low power. After warm-up and
rechecking the voltage, if still < 2.0V, operation repeats.
Treatments for smoke alarm:
1. Inspect the causes. If it is caused by cigarette smoking or
other reasons and not a fire alarm, just remove the smoke
resource and the alarm will reset. If it is a false alarm, check
if the installing position is improper.
2. If a fire breaks out, in the early stage, use a fire extinguisher
to put out the fire.
3. If the fire is large, don’t panic. Escape asap and then call the
police.
2
INDICATIONS SUMMARY
Indications Analysis Elimination
+
LED flashes Green
once every 30s
Normal indication for normal
working status and normal
battery supply
LED flashes Red
Normal. Caused by pressing Test &
Hush Button under alarm or testing
status. Detector enters into Mute
status.
Repress the Test
& Hush Button to
lift the mute status
LED flashes Yellow
once every 30s
along with buzzer
sounding
Low battery (<2.4V) Replace new
batteries
Replace new
batteries
LED constant
Yellow
Low battery ( that can not
support normal operation
<2.0V)
LED flashes Yellow
twice every minute
along with buzzer
sounding
Malfunction in smoke chamber
Contact your
dealer for
repairing or
replacement