Operating Manual of Intelligent Digital
Tachometer
I. Characteristics
1. Beautiful and elegant appearance design, convenient and
comfortable to use;
2. Wide measurement range, and high resolution;
3. Single-chip microcomputer technology, photoelectric
technology and anti-interference technology used, to
accurately measure the rotation speed;
4. Super large-size LCD, with clear reading;
5. Automatically memorizing the measured maximum,
minimum and the last displayed values;
6. Low power indication when the battery voltage is lower
than the specified value;
7. Automatic off: Automatic off in about 15min when no
key is operated.
II. Specifications
Function
Photoelectric type
△
Contact type
△
Contact line speed
(metric system)
△
Display: 5-digit 18mm LCD
Accuracy: ± (0. 05%+1)
Range selection: Automatic range
Effective distance: 50mm-500mm
Dimension: 150mm*65mm*31mm
Power supply: 4*1.5V AAA batteries
Power consumption: Less than 40mA
Weight: About 156g (including batteries)
Measurement range:
2.5-99999 rpm for photoelectric rotation speed
1.0-19999 rpm for contact rotation speed
1.00-1999.9 m/min for contact line speed
Resolution:
Photoelectric rotation speed: 0.1rpm (2.5-999.99rpm)
1rpm (above 1000rpm)
Contact rotation speed: 0.1rpm (0.5-999.99rpm)
1rpm (above 1000rpm)
Contact line speed: 0.01m/min (0.05-99.999m/min)
0.1m/min (above 100m/min)
III. Operation Instructions
1.Starting up
Load four 1.5V AAA batteries (the anode and cathode directions
according to the identifications in the battery case). Long press
ON/OFF key to switch it on or off, and short press this key for
function selection.
2. Photoelectric rotation speed:
A: Stick one reflective marker on the object to measure.
B: Long press ON/OFF to switch it on, short press ON/OFF to
select the measurement mode photo RPM, and remove the
contact accessory installed, if any.
C. Press TEST key to make the visible beam and the measured
target in a line. Release the TEST key after the displayed value
stabilizes and the measured maximum, minimum and the last
displayed values will be automatically stored in the instrument.
D.Press MEM key to display the maximum, minimum and the
last measured values.
3. Contact rotation speed
A. Short press ON/OFF to select the measurement mode: contact
RPM, and install the contact accessory.
B. Get the contact rubber head close with the measured object
and make it rotate in sync with the measured object.
C. Press TEST key to start measuring, and release the TEST key
after the displayed value stabilizes and the measured values will
be automatically stored.
D. Press MEM key to display the maximum, minimum and the
last measured values.
4. Contact line speed
A. Short press ON/OFF to select the measurement mode: m/min
(metric system), and install the contact accessory.
B. Get the contact accessory close with the measured object and
make it rotate in sync with the measured object.
C. Press TEST key to start measuring, and release the TEST key
after the displayed value stabilizes and the measured values will
be automatically stored.
D. Press MEM key to display the maximum, minimum and the
last measured values.
5. Measurement Notes
A: Reflective marker: Cut off 12mm square adhesive tapes, and
stick one on each rotation axis. Pay attention that the
non-reflective area shall be larger than the reflective area. If the
rotation axis obviously gives out light, first smear it with black
paint or stick black tape, and then stick reflective marker thereon;
rotation axis surface must be clean and smooth before sticking of
the reflective marker.
B: Measurement of low rotation speed: To improve the
measurement accuracy, user is recommended to evenly stick
more reflective markers on the measured object when the rotation
speed is very low, and then divide the reading on the display by
the number of reflective markers to obtain the actual measured
value.
C. Please take out the batteries if not to use the instrument for a
long time, so as to avoid damaging the instrument by corroded
batteries.
6. Description of MEM Function
When TEST key is released, the display will display “0”and
current measurement mode, but the measured maximum,
minimum and the last measured values are automatically stored
in the instrument, and at this time, press MEM key for it to
display the measured values, wherein “MAX”means maximum,
“MIN”means minimum, and “LA”means the last value. Each
time the MEM is pressed, another memorized value will be
displayed.
7. Battery Replacement
A. When batteries are lower than 3.7V, LCD will display
icon to prompt for battery replacement.
B. Open the battery cover and take out batteries, and then
correctly install batteries according to the identifications in the
battery case.
Accessories:
Reflective tape 600mm long
Manual 1 copy
Accessory for contact line speed measurement 1 piece
Accessory for contact rotation speed measurement 3 pieces
Panel description as shown below
Attention: Photoelectric type measurement is
recommended during measurement of high
rotation speed for sake of safety.
601E-6236-000C
Accessory for contact line speed
Dual-purpose accessory for
photoelectric type and contact type
Accessory for contact rotation speed
TEST key
MEM key
ON/OFF and function selection

Other Hellermann Tyton Measuring Instrument manuals

Hellermann Tyton ACADEMY TCTRP Instruction Manual

Hellermann Tyton

Hellermann Tyton ACADEMY TCTRP Instruction Manual

Hellermann Tyton 2608 User manual

Hellermann Tyton

Hellermann Tyton 2608 User manual

Hellermann Tyton t201 User manual

Hellermann Tyton

Hellermann Tyton t201 User manual

Hellermann Tyton T609 User manual

Hellermann Tyton

Hellermann Tyton T609 User manual

Popular Measuring Instrument manuals by other brands

Nidec FG-7000L Operation manual

Nidec

Nidec FG-7000L Operation manual

OxyCare A360 user manual

OxyCare

OxyCare A360 user manual

SIGLENT SNA5000A quick start

SIGLENT

SIGLENT SNA5000A quick start

eSYNiC SV023 instruction manual

eSYNiC

eSYNiC SV023 instruction manual

Mantech Ap2000 instruction manual

Mantech

Mantech Ap2000 instruction manual

Ecomatik DD-S2 user manual

Ecomatik

Ecomatik DD-S2 user manual

Eclipse VeriFlame 5600 instruction manual

Eclipse

Eclipse VeriFlame 5600 instruction manual

Thermo Scientific LevelPRO Series installation guide

Thermo Scientific

Thermo Scientific LevelPRO Series installation guide

Traceable 4277 instructions

Traceable

Traceable 4277 instructions

Eurotherm 2408i user guide

Eurotherm

Eurotherm 2408i user guide

sauter FS Series manual

sauter

sauter FS Series manual

VOLTCRAFT ORP-01 operating instructions

VOLTCRAFT

VOLTCRAFT ORP-01 operating instructions

Siemens Sitrans LR250 instruction manual

Siemens

Siemens Sitrans LR250 instruction manual

Danaher Veeder-Root 7990 Series quick start guide

Danaher

Danaher Veeder-Root 7990 Series quick start guide

Cirris Signature 1000R+ user guide

Cirris

Cirris Signature 1000R+ user guide

Trotec BP17 operating manual

Trotec

Trotec BP17 operating manual

Sper scientific 800046 instruction manual

Sper scientific

Sper scientific 800046 instruction manual

janitza optec UMG-96 operating instructions

janitza

janitza optec UMG-96 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.