Heltun HE-HLS01 User manual

HE-HLS01 USER MANUAL 1
HIGH LOAD SWITCH
HE-HLS01 USER MANUAL
for Hardware v.84 & Firmware v.1.5

HE-HLS01 USER MANUAL 2
MANUAL REVISION HISTORY………………………………………………………………3
OVERVIEW ..................................................................................................................4
TECHNICAL SPECIFICATIONS...................................................................................5
FUNCTIONS & FEATURES..........................................................................................5
INSTALLATION ............................................................................................................6
DISASSEMBLY.............................................................................................................8
FACTORY RESET........................................................................................................8
Z-WAVE NETWORK.....................................................................................................8
Adding to Z-Wave network .......................................................................................9
Removing from Z-Wave network ............................................................................10
Security..................................................................................................................10
SmartStart.............................................................................................................. 10
Firmware OTA Update............................................................................................11
Z-WAVE PLUS V2 SPECIFICATIONS........................................................................12
ASSOCIATIONS.........................................................................................................14
SETTINGS (available through Z-Wave network).........................................................15
DEVICE TYPE “BINARY SWITCH”.............................................................................15
Parameters List & Factory Defaults ........................................................................ 15
Z-Wave Frequency................................................................................................. 18
Hardware & Software Versions............................................................................... 19
Power and Energy Consumption............................................................................ 19
Input & Outputs ...................................................................................................... 20
Temperature Configurations................................................................................... 20
Time Configurations ............................................................................................... 20
Auto On/Off function............................................................................................... 21
External Input Configuration ................................................................................... 22
Scenarios ...............................................................................................................23
Energy and Sensor Report Interval......................................................................... 24
Protections and Notifications ..................................................................................25
DEVICE TYPE “THERMOSTAT”.................................................................................27
Parameters List & Factory Defaults ........................................................................ 28
Z-Wave Frequency................................................................................................. 32
Hardware & Software Versions............................................................................... 33
Power and Energy Consumption............................................................................ 33
Input & Outputs ...................................................................................................... 34
Temperature Configurations................................................................................... 34
Time Configurations ............................................................................................... 35
Time Mode Schedule.............................................................................................. 35
Energy and Sensor Report Interval......................................................................... 36
Protections and Notifications ..................................................................................37
Basic Set Command...............................................................................................39
LIMITED WARRANTY ................................................................................................40

HE-HLS01 USER MANUAL 3
MANUAL REVISION HISTORY
October 2021
•Firmware V1.5 - Added “Parameter 66 –Retore Relay State”
•Firmware V1.5 –Changed the default values for overvoltage and voltage drop
protections
•Firmware V1.3 - Added “Parameter 46 –Hold Mode Duration for External Input S1”
•Firmware V1.3 - Max supported Nodes for each Association Group increased to 5
•Firmware V1.2 - Added “Parameter 159 –Load On Notification”
•Firmware V1.2 - Added “Parameter 160 –Load Off Notification”
Detailed Changelog & OTA update files can be found at support.heltun.com

HE-HLS01 USER MANUAL 4
OVERVIEW
The HELTUN HE-HLS01 High Load Switch with Thermostat Functions brings incredible
capabilities to any connected device: saving energy, wireless control of connected devices,
and absolute comfort and convenience for your home. It fits easily behind outlets or switches
in standard electrical junction boxes or in a circuit breaker panel connected to entire banks of
lights or outlets making them ‘Impossibly Smart’ with over-the-Internet monitoring, control, and
advanced programmability.
Full thermostat functions
The High Load Switch provides Internet-connected thermostat functions where a local display
and controls are not needed such as roof or driveway de-icing systems. An included NTC
temperature sensor can be installed on the wall, under floorboards, on the roof, or under
decking allowing accurate monitoring of ambient or radiant floor/roof system temperatures.
Inputs & outputs
It can also be connecting to external switches or systems—such as a light switch or alarm
system, etc.—through a pilot wire to allow direct or pre-programmed control of connected
devices using eight different modes.
Know how much energy you use
Determine how much energy is used by major appliances, entertainment systems, computers,
small appliances, or entire lighting systems by monitoring how much energy has passed
through the HE-HLS01 during any particular day, week, or month.
Makes circuit breakers ‘Impossibly Smart’
Since the High Load Switch can handle up to 16 Amp loads, it is a perfect addition to your
circuit breaker panel for monitoring and controlling groups of devices from the Internet through
a Z-Wave™ gateway.
Safety
The High Load Switch adds safety to your home by protecting against overloads, overheat,
sparks conditions, and it can even be configured to turn off an outlet if a family member leaves
a high load device turned on for a long period of time, possibly preventing a fire.
Enables scenarios triggered by time
The High Load Switch has an onboard Real Time Clock (RTC) that enables scenarios where
connected devices can be triggered on a schedule.
Based on the latest Z-Wave platform
The HE-HLS01 integrates a Z-Wave Plus™ v2 700 platform module allowing it to be used with
Z-Wave home automation systems. The HE-HLS01 supports Z-Wave ‘S0’ and ‘S2’ security
protocols, SmartStart technology, and can be connected (associated) to other Z-Wave
devices, such as relays, motor controllers, dimmers, etc.

HE-HLS01 USER MANUAL 5
TECHNICAL SPECIFICATIONS
▪Dimensions: 50mm (H) х 50mm (W) х
26mm (D)
▪Materials: Flame retardant plastic
▪LED indicator for device status
▪Operating temperature: 0°C to +50°C
▪Power supply: 85-265VAC
50Hz/60Hz, 24-48VDC
▪Power consumption: 1W
▪Active elements: Electromagnetic
Relay Switch
▪Maximum resistive load: 16А, 4000W
@ 250VAC
▪HELTUN Advanced Zero-Cross relay
switching technology
▪Relay lifetime: 100.000 switches
▪External floor temperature sensor
NTC 10kΩ
Measurement range: -20°C to
+100°C
Accuracy: ±0.5°C
▪Device control
Through Z-Wave network
Directly with pilot wire
▪Real-time energy consumption meter
▪IP class: IP21
▪Z-Wave Plus V2 SDK: V7.11
▪Z-Wave module: ZGM130S
▪Can be mounted to flush electrical
junction box:
▪round, square or rectangular type –min.
depth 40
FUNCTIONS & FEATURES
The functions and features of HE-HLS01 could be different depending on how the device is
included in Z-Wave network. Depending on the number of button presses (two or four) during
the inclusion process HE-HLS01 could function as either “Binary Switch” or “Thermostat”.
In case if the device is already included in Z-Wave network and there is a need to change the
device type, it should be removed from network and re-included with the corresponding type.
COMMON FOR “BINARY SWITCH” AND “THERMOSTAT” DEVICE TYPES
▪Options for Inclusion/Exclusion
to/from Z-Wave network
Non-Secure
S0 Secure
S2 Unauthorized, S2 Authorized
with Key
▪Association control of devices in z-
wave network
▪8 safety functions:
Overheat protection &
notification
Temperature Rise protection &
notification
Over-current protection &
notification
Over-load protection &
notification
Over-voltage protection &
notification
Voltage drop protection &
notification
Spark & Surge protection &
notification
Device Failure notification
▪External control input
▪Periodic measurements from:
External temperature sensor
Energy consumption meter
▪Can be used with different NTC-sensors
(range: 1kΩ to 100kΩ)
▪Calibration of External NTC
Temperature Sensor
▪Zero-cross relay switching
▪NO/NC relay mode
▪LED indicator blinking function (for easy
identification among other Z-Wave
devices)
▪Real-time and cumulative energy usage
to 0.1kW accuracy
▪Factory reset function
▪SmartStart technology for quick addition
to Z-Wave networks
▪Encrypted OTA (Over The Air) firmware
update feature
▪Z-Wave Frequency change

HE-HLS01 USER MANUAL 6
“BINARY SWITCH” DEVICE TYPE
▪Auto On/Off function
Switch output Off if there is no
consumption
Switch output On when the load
is reconnected
▪Time limit for high load
▪Timer mode for relay control
▪10 scenarios for relay control
“THERMOSTAT” DEVICE TYPE
▪6 operational modes with individual
temperature set points:
Heat –Most comfort mode
Auto –Time schedule mode
Dry –Fast floor drying mode
Energy Saving –Power efficient
mode
Away –Vacation mode
Off –Thermostat Off (IDLE)
mode
▪4-time schedules for 7 days of the
week:
Morning
Day
Evening
Night
▪Additional safety function:
Load Failure notification
▪Can be used with different NTC-
sensors (range: 1kΩ to 100kΩ)
▪Temperature set intervals: 1.0°C to
110.0°C
▪Temperature scale selection (Celsius
or Fahrenheit)
▪Temperature hysteresis selection
range: 0.2°C to 10.0°C
INSTALLATION
The HELTUN HE-HLS01 High Load Switch must be installed by a licensed electrician in a
manner that conforms to local regulations and building codes. Provide these instructions to
the licensed electrician who is installing the HE-HLS01.
WARNING: ELECTRICAL POWER MUST BE SWITCHED OFF DURING INSTALLATION.
1. FIRST ENSURE THE POWER IS OFF at the main circuit breaker, and then test the wires
with a probe or multimeter to verify.
2. Insert the power and load wires to the correct HE-HLS01 terminals by inserting a small
Phillips-head screwdriver in the slot beneath each terminal and unscrew to open.

HE-HLS01 USER MANUAL 7
Follow connection diagrams 1 (or 2 or 3 or 4) and the instructions below:
▪Power wires: for AC power (85-265VAC) connect Line & Neutral lead wires to L & N
terminals labeled “IN”. For DC power (24-48VDC) connect “+” wire to terminal N and
“–” wire to terminal L.
▪Load wires: connect Line & Neutral wires to L & N terminals labeled with “heating
element” graphic
≡Note: it is possible to connect Neutral wire from load directly to your neutral line
(Connection diagrams 2 or 4).
≡Note: HELTUN recommends installing cord terminals (electric wire ferrules) on the
ends of wires before connecting them to the HE-HLS01 outputs (various colors
terminals are included).
≡Note: Zero-Cross technology is unavailable if the device is DC (24-48VDC) powered.
Tighten wires using Phillips screwdriver in slot beneath each wire.
Connection diagram 1
Connection diagram 2
3. If using the HE-HLS01 for radiant floor heating, connect the NTC temperature sensor wire to
the terminals labeled “NTC.” A 10 kΩ NTC sensor is included inside the HE-HLS01
packaging, but any NTC sensor can be used.
≡Note: If an NTC sensor other than 10 kΩ is used, you must change the sensor resistance
value in Parameter 10.
4. If you will be using an external device to select modes for the HE-HLS01 (such as a security
system or wall switch), connect wires from the external device’s dry contacts to the two HE-
HLS01 terminals labeled “S1” & “Sx”.
Two different connection methods for external control are possible:
▪Connect S1 to Sx through dry contact switch (Connection diagrams 1 or 2)
▪Connect S1 to electric network Line through dry contact switch (Connection diagrams 3
or 4)
≡Note: In case of using “Connection Diagram 3 or 4”, it is MANDATORY to connect S1
terminal to the same wire connected to terminal N on the device (labeled as “IN”)
through dry contacts of an external device (like wall switch).

HE-HLS01 USER MANUAL 8
Connection diagram 3
Connection diagram 4
5. Switch On the main power at the circuit breaker. The HE-HLS01 will start up with the
original default factory settings and the LED indicator will blink red slowly meaning the
device is excluded from a Z-Wave network.
DISASSEMBLY
1. ENSURE POWER IS SWITCHED OFF at the main circuit breaker AND THE LED
INDICATOR IS OFF.
2. Disconnect the wires by inserting a small Phillips-head screwdriver into the slot beneath
each wire and unscrewing to release.
FACTORY RESET
To reset the HE-HLS01 to factory defaults, press and hold the service button for six seconds.
If successful, the LED indicator will blink white for two seconds then the device will reboot.
The factory reset will change all the Parameters to their original factory default values and will
also Exclude the device from any Z-Wave network.
≡Note: Please use this procedure only when the network primary controller is missing
or otherwise inoperable.
Z-WAVE NETWORK
The HE-HLS01 may be operated in any Z-Wave network with other Z-Wave-certified devices
from other manufacturers. The HELTUN HE-HLS01 will act as a ‘repeater’ (i.e. ‘range
extender’) for other devices regardless of manufacturer or brand to increase the reliability of
the overall network.

HE-HLS01 USER MANUAL 9
Adding to Z-Wave network
To add the HE-HLS01 to an existing Z-Wave network (i.e. “inclusion”), do the following:
1. Ensure the HE-HLS01 is Powered On and the LED indicator blinks red slowly (i.e. it is
excluded).
2. Start the Inclusion Mode from the gateway/controller.
3. To start the inclusion process on the HE-HLS01:
a) if you want to use the device as a “Binary Switch”, double-press the service button on
the device (with no more than a one-second interval between presses).
b) if you want to use the device as a “Thermostat”, press four times the service button
on the device (with no more than a one-second interval between presses).
4. The LED indicator will blink green quickly.
5. If the inclusion has been successful, the LED indicator will turn green for three seconds
then continue slowly blinking green while the HE-HLS01 device type is “Binary Switch”
and turn blue for three seconds then continue slowly blinking blue while the device type
is “Thermostat”.
6. If the inclusion was not successful, the LED indicator will turn red for three seconds then
continue slowly blinking red continuously while the HE-HLS01 is Powered On. In that case
repeat the inclusion process (2-5) above

HE-HLS01 USER MANUAL 10
Removing from Z-Wave network
To remove the HE-HLS01 from a Z-Wave network (i.e. “Exclusion”), do the following:
1. Ensure the HE-HLS01 is Powered On and the LED indicator blinks green or blue slowly
(i.e. it is included in a Z-Wave network).
2. Start the Exclusion Mode from the gateway/controller.
3. To start the exclusion process on the HE-HLS01, double-press the service button on the
device (with no more than a one-second interval between presses).
4. The LED indicator will blink red quickly.
5. If the exclusion has been successful, LED indicator will turn red for three seconds then
continue slowly blinking red continuously while the HE-HLS01 is Powered On.
6. If the exclusion was not successful, the LED indicator will turn green or blue for three
seconds then continue slowly blinking green or blue continuously while the HE-HLS01 is
Powered On. In that case repeat the exclusion process (2-5) above.
Note: If the HE-HLS01 has previously been part of a Z-Wave network and not Excluded since
(the LED indicator blinks green or blue slowly), Inclusion is not possible without first performing
an Exclusion or Factory Reset procedure.
Security
S0, S2 unauthorized, and S2 authorized Inclusion Modes are supported. If you use the S2
authorized Inclusion Mode, the security key should be used during the inclusion process.
Security key is the first 5 digits of DSK (device DSK is printed on the rear of the device plus
on the Security Card included in the packaging, see Figures 2 & 3).
≡Note: Be sure to save this key. Without the key, it is impossible to perform an inclusion
in S2 authorized mode.
SmartStart
SmartStart-enabled products can be added to a Z-Wave network by scanning the Z-Wave QR
Code shown on the product (see Figures 1 & 3) with gateways/controllers that provide for
SmartStart inclusion. In this case, no further action will be required and the SmartStart product
will be added automatically within ten minutes of being turned on in the vicinity of a network.
To add the HE-HLS01 to the Z-Wave network using SmartStart:
1. Input the High Load Switch DSK to the controller’s Node Provisioning List (or scan the QR
code)
2. Power on the device.
3. Wait for the adding process to complete.
4. Successful adding will be confirmed by a message on the Z-Wave controller and the LED
indicator on HE-HLS01 will turn green for three seconds then continue to slowly blink
green continuously while the device is Powered On.
≡Note: The device QR code and DSK are printed on the front and rear of the HE-
HLS01 plus on the additional Security Card included in the packaging (see Figures 1,
2 & 3).

HE-HLS01 USER MANUAL 11
≡Note: During SmartStart inclusion the device will be included to the gateway as a
binary switch. If you want to use the device as a thermostat, use manual inclusion
process.
Figure 1
Figure 2
Figure 3
Firmware OTA Update
To wirelessly update the HE-HLS01 firmware, follow these steps:
1. Check the device current firmware version in the gateway/controller.
2. Start the process from the Z-Wave gateway/controller.
3. Download the latest firmware that corresponds to the HE-HLS01 (see
http://support.heltun.com/ )
4. Set the main controller in Firmware OTA (“over-the-air”) Update Mode (see the
gateway/controller manual).
5. As soon as the Firmware update begins, the LED indicator will sequentially blink
red→green→blue (this will take a few minutes).
6. When the Firmware has updated, the LED will turn blue for two seconds and then the HE-
HLS01 will reboot.
7. When the update has been completed, the HE-HLS01 will return to normal operation.
8. If desired, verify the update was successful by checking firmware version from the
gateway/controller.

HE-HLS01 USER MANUAL 12
Z-WAVE PLUS V2 SPECIFICATIONS
Thermostat Generic Device Class: GENERIC_TYPE_THERMOSTAT
Thermostat Specific Device Class: SPECIFIC_TYPE_THERMOSTAT_GENERAL_V2
Binary Switch Generic Device Class: GENERIC_TYPE_SWITCH_BINARY
Binary Switch Specific Device Class: SPECIFIC_TYPE_NOT_USED
Supported Command Classes
Command Class
Version
Required Security Class
Binary
Switch
Thermostat
Z-Wave Plus Info
V2
none
V
V
Association
V2
highest granted (S2 Authenticated,
S2 Unauthenticated or S0)
V
V
Association Group Info
V3
highest granted (S2 Authenticated,
S2 Unauthenticated or S0)
V
V
Multi Channel
Association
V3
highest granted (S2 Authenticated,
S2 Unauthenticated or S0)
V
V
Thermostat Operating
State
V1
highest granted (S2 Authenticated,
S2 Unauthenticated or S0)
X
V
Thermostat Mode
V3
highest granted (S2 Authenticated,
S2 Unauthenticated or S0)
X
V
Thermostat Setpoint
V3
highest granted (S2 Authenticated,
S2 Unauthenticated or S0)
X
V
Switch Binary
V2
highest granted (S2 Authenticated,
S2 Unauthenticated or S0)
V
X
Sensor Multilevel
V11
highest granted (S2 Authenticated,
S2 Unauthenticated or S0)
V
V
Meter
V5
highest granted (S2 Authenticated,
S2 Unauthenticated or S0)
V
V
Clock
V1
highest granted (S2 Authenticated,
S2 Unauthenticated or S0)
V
V
Transport Service
V2
none
V
V

HE-HLS01 USER MANUAL 13
Security 0
V1
none
V
V
Security 2
V1
none
V
V
Version
V3
highest granted (S2 Authenticated,
S2 Unauthenticated or S0)
V
V
Manufacturer Specific
V2
highest granted (S2 Authenticated,
S2 Unauthenticated or S0)
V
V
Device Reset Locally
V1
highest granted (S2 Authenticated,
S2 Unauthenticated or S0)
V
V
Powerlevel
V1
highest granted (S2 Authenticated,
S2 Unauthenticated or S0)
V
V
Supervision
V1
none
V
V
Indicator
V3
highest granted (S2 Authenticated,
S2 Unauthenticated or S0)
V
V
Configuration
V4
highest granted (S2 Authenticated,
S2 Unauthenticated or S0)
V
V
Application Status
V1
none
V
V
Firmware Update Meta
Data
V5
highest granted (S2 Authenticated,
S2 Unauthenticated or S0)
V
V
Basic
V2
highest granted (S2 Authenticated,
S2 Unauthenticated or S0)
V
V
Notification
V8
highest granted (S2 Authenticated,
S2 Unauthenticated or S0)
V
V
Meter Command Class:
Meter Type
Scale
Rate Type
Precision
Size
Electric [0x01]
Electric_kWh [0x00]
Import [0x01]
2
4
Electric [0x01]
Electric_W [0x02]
Import [0x01]
0
2
Electric [0x01]
Electric_V [0x04]
Import [0x01]
0
2
Notification Types:

HE-HLS01 USER MANUAL 14
Notification
Type
Event/State
Binary
Switch
Thermostat
Heat Alarm
Overheat detected
V
V
Rapid temperature rise
V
V
System
System hardware failure (manufacturer
proprietary failure code provided)
V
V
Power
Management
AC mains disconnected
V
X
AC mains re-connected
V
X
Over-current detected
V
V
Over-voltage detected
V
V
Over-load detected
V
V
Surge detected
V
V
Voltage drop/drift
V
V
Load error
X
V
ASSOCIATIONS
Association enables the HE-HLS01 to control other Z-Wave devices over the network. An
Association Group may include up to five other devices from different brands and/or
manufacturers. The HE-HLS01 has four association groups:
Group 1 –“Lifeline”: reports state of the device and used to communicate with the Z-Wave
gateway. The group supports one Node.
≡Note: It is not recommended to modify this group.
Group 2 –“Relay Basic Set”: is assigned to the HE-HLS01 relay state. It sends a Basic Set
command with value 255 (On) when relay goes to On state and sends 0 (Off) when relay goes
to Off state. The group supports five Nodes.
Group 3 –“S1 Basic Set”: is assigned to the HE-HLS01 external input state. It sends a Basic
Set command with value 255 (On) when external input is shorted and sends 0 (Off) when input
is open. The group supports five Nodes.
Group 4 –“Temperature Sensor”: is assigned to the HE-HLS01 external temperature
sensor and sends the sensor value when it changes. The group supports five Nodes.
The device also can receive Basic Set command via associations. In the “Binary Switch” mode
the device will change the relay state according to the value in Basic Set command. In the
“Thermostat” mode the device will change the operating mode according to the Parameter
171 value from Thermostat parameters list.

HE-HLS01 USER MANUAL 15
SETTINGS (available through Z-Wave network)
All configuration parameters are accessed through Z-Wave
COMMAND_CLASS_CONFIGURATION
DEVICE TYPE “BINARY SWITCH”
Parameters List & Factory Defaults
These parameters will take affect only in case if the device is included in the Binary Switch
mode. For more information about the different inclusion modes see the section Z-Wave
Network.
Number
Size
Description
Default
Value
Available Values
1
1 byte
Frequency Region
0 = EU, 1 = US, 2 = ANZ
3 = HK, 4 = IN, 5 = IL
6 = RU, 7 = CN, 8 = JP
9 = KR
Read
Only
0 … 9
2
1 byte
Included Device Type
1 = Binary Switch
2 = Thermostat
Read
Only
1, 2
3
4 bytes
Hardware and Software Versions
Read
Only
XXYYZZ
4
4 bytes
Energy Consumption, kW
Read
Only
Total consumption
5-6
Reserved by the manufacturer
7
1 byte
Relay output NO or NC mode
0
0, 1
8-9
Reserved by the manufacturer
10
1 byte
Floor Sensor Resistance, kΩ
10
1 … 100
11-16
Reserved by the manufacturer
17
1 byte
Temperature Sensor Calibration in °C,
value X 10, e.g. 1.5°C=15
0
-100 … 100 °C

HE-HLS01 USER MANUAL 16
18
Reserved by the manufacturer
19
1 byte
Time correction by controller
1
0, 1
20
Reserved by the manufacturer
21
1 byte
Week Day
1
1, 2, 3, 4, 5,
6, 7
22
2 bytes
Time: Hour and Minutes
0
0 … 2359
23
1 byte
Load Auto On/Off
0
0, 1
24
1 byte
Auto Off Timeout
5
0 … 120
25
1 byte
Auto ON Reconnect Timeout
0
0 … 120
26
2 bytes
Time Limited Load
0
0, 100 … 3500
27
2 bytes
High Load ON Time Limit
0
0 …. 1440
28-40
Reserved by the manufacturer
41
1 byte
S1 Input Hold Control Mode
2
0, 1, 2, 3
42-45
Reserved by the manufacturer
46
1 byte
Hold Mode Duration for External Input S1
500
200 … 5000
47-50
Reserved by the manufacturer
51
1 byte
S1 Input Click Control Mode
1
0, 1, 2, 3, 4, 5
52-65
Reserved by the manufacturer
66
1 byte
Restore Relay State After Power Failure
0
0, 1
67-70
Reserved by the manufacturer

HE-HLS01 USER MANUAL 17
71
2 bytes
Relay Timer Duration
0
0 … 43200
72-110
Reserved by the manufacturer
111
4 bytes
Relay control scenario 1
0
0, 1000000 …
1912359
112
4 bytes
Relay control scenario 2
0
0, 1000000 …
1912359
113
4 bytes
Relay control scenario 3
0
0, 1000000 …
1912359
114
4 bytes
Relay control scenario 4
0
0, 1000000 …
1912359
115
4 bytes
Relay control scenario 5
0
0, 1000000 …
1912359
116
4 bytes
Relay control scenario 6
0
0, 1000000 …
1912359
117
4 bytes
Relay control scenario 7
0
0, 1000000 …
1912359
118
4 bytes
Relay control scenario 8
0
0, 1000000 …
1912359
119
4 bytes
Relay control scenario 9
0
0, 1000000 …
1912359
120
4 bytes
Relay control scenario 10
0
0, 1000000 …
1912359
121-140
Reserved by the manufacturer
141
1 byte
Consumption meter consecutive reporting
interval, minutes
10
1 … 120
142
1 byte
Consumption difference to send to
controller, %
25
0, 1 … 50
143
1 byte
Sensors consecutive reporting interval,
minutes
10
1 … 120
144
1 byte
Temperature difference to send to
controller, value X 10
2
0, 1 … 100 for °C
145-150
Reserved by the manufacturer
151
1 byte
System Error Notification
1
0, 1

HE-HLS01 USER MANUAL 18
152
2 bytes
Temperature Rise Notification
50 for °C
0, 1 … 120 for °C
153
2 bytes
Overheat Protection Level
60 for °C
0, 1 … 120 for °C
154
1 byte
Overcurrent Notification
1
0, 1
155
2 bytes
Overload Protection Level
3500
0, 100 …. 4000
156
2 bytes
Overvoltage Protection Level
260
0, 120 … 280
157
2 bytes
Voltage Drop Protection Level
90
0, 80 … 240
158
1 byte
Spark Protection
1
0, 1
159
1 byte
Load On Notification
0
0, 1
160
1 byte
Load Off Notification
0
0, 1
161-200
Reserved by the manufacturer
Z-Wave Frequency
Parameter 01 –Frequency Region
The HE-HLS01 has Z-Wave 700 series chip inside which allows to use the device in different
Z-Wave frequencies. If there is a need to use the device in the frequency different from the
factory default, change the value of this Parameter according to the frequency list below.
≡Note: The factory default frequency differs depending on which region the device was
intended for sale in. Check the factory default frequency on the device plate or on the
packaging.
≡Note: Do not change this Parameter value if there is no special need.
≡Note: If change the value of this Parameter, the frequency change will be applied only
after removing the device from Z-Wave network (the device will automatically reboot).
≡Note: The change of this Parameter will result in inability to control the device, if the
device was included to the controller/gateway which supports only one frequency.
≡Note: Resetting the device to factory default settings will revert the frequency to the
factory default value.
≡Note: In most of countries it is not allowed to use the frequency different from the
frequency intended for that country.
Frequency list for different regions:

HE-HLS01 USER MANUAL 19
0: EU (868.4 MHz, 869.85 MHz)
1: US (908.4 MHz, 916.0 MHz)
2: ANZ (919.8 MHz, 921.4 MHz)
3: HK (919.8 MHz)
4: IN (865.2 MHz)
5: IL (916.0 MHz)
6: RU (869.0 MHz)
7: CN (868.4 MHz)
8: JP (922.5 MHz, 923.9 MHz, 926.3 MHz)
9: KR (920.9 MHz, 921.7 MHz, 923.1 MHz)
The full list of Z-Wave global regions where Z-Wave works is available at Z-Wave Global
Regions SiLabs page
Hardware & Software Versions
Parameter 03 –Hardware and Software Versions
This Parameter allows to check the hardware and firmware versions of the device. The
Parameter returns value in the format XXYYZZ, where XX is Hardware Version, YY is
Firmware Major Version and ZZ is Firmware Minor Version.
≡Note: This Parameter is read-only.
Power and Energy Consumption
HE-HLS01 monitors Real-Time and Cumulative power Energy Consumption and Voltage
using advanced micro-controller technology which assures maximum accuracy (±1% for loads
greater than 1000W). Real-Time Consumption, Cumulative Consumption, and network
Voltage are periodically reported to the Z-Wave controller (according to the Parameters 141
and 142):
Parameter 04 –Energy Consumption
This Parameter allows you to check the Cumulative Energy Consumption of the connected
load. Through the Z-Wave network this Parameter returns Total Cumulative Consumption
value in kWh.
≡Note: This Parameter is read-only.
Resetting Cumulative Consumption memory:
The HE-HLS01 allows to erase stored Consumption Data through Z-Wave network.
The HE-HLS01 enables you to erase stored Consumption Data through the Z-Wave network
as follows:
1. Make sure the HE-HLS01 is powered.
2. If not already done so, include the device into Z-Wave Gateway network.
3. Reset memory consumption data using the Reset Command in
COMMAND_CLASS_METER (see the Gateway owner’s manual).
≡Note: Turning the device main power off/on will not erase the consumption data as it
is stored in nonvolatile memory.

HE-HLS01 USER MANUAL 20
Input & OutputsConfigurations
Parameter 07 –Relay output mode (NO / NC)
This Parameter determines the type of load connected to the device relay output. The output
type can be NO –normal open (no contact/voltage switch the load OFF) or NC - normal close
(output is contacted / there is a voltage to switch the load OFF). Choose the value 0 if NO
contact type is required or value 1 if NC type is required.
The factory default value is 0.
Parameter 10 –Floor Sensor Resistance
If the external floor NTC temperature sensor is used it is necessary to select the correct
resistance value in Ohms (Ω) of the sensor. The selection range is 1 to 100 kiloOhms (kΩ).
One 10kΩ NTC floor temperature sensor is included in the HE-HLS01 package with a 3-meter
connection wire. The factory default value is 10kΩ.
Temperature Configurations
Parameter 17 –Temperature Sensor Calibration
This Parameter defines the offset value for floor temperature. If the external floor temperature
sensor is not calibrated properly, then manual calibration can be made by adjusting the values
up to ±10.0°C. This value will be added or subtracted from the floor temperature sensor
reading. Through the Z-Wave network the value of this Parameter should be x10, e.g. for
1.5°C set the value 15. The factory default value is 0.
Time Configurations
Parameter 19 –Time Correction by Main Controller
If this Parameter value = 1 and the HE-HLS01 is connected to a Z-Wave gateway, the HE-
HLS01 time and day will be periodically polled and corrected from the gateway. To switch off
auto-correction set the Parameter value to 0. The factory default value is 1.
Parameter 21 –Day of the Week Manual Adjustment
This Parameter allows manual adjustment of the day of the week in case the HE-HLS01 is
not connected to any Z-Wave gateway or auto-correction is disabled (Parameter 19 value is
0). 1 = Monday, 2 = Tuesday, 3 = Wednesday, 4 = Thursday, 5 = Friday, 6 = Saturday, 7 =
Sunday. The factory default value is 1.
Parameter 22 –Time Manual Adjustment
This Parameter allows manual adjustment of Time. The Parameter has the following format:
HHMM, where HH is hours and MM is minutes. E.g. for 16:08 set the value 1608 and for 1:00
set the value 100.
Other manuals for HE-HLS01
2
Table of contents
Other Heltun Switch manuals
Popular Switch manuals by other brands

Dell
Dell POWEREDGE M905 Information update

Lindy
Lindy 38272 user manual

EDP
EDP GEIST COOL SwitchAir SA1-02003 Series installation guide

Matrix Switch Corporation
Matrix Switch Corporation MSC-CP8X4E product manual

Panasonic
Panasonic PN260496-NZ installation guide

Alps Electric
Alps Electric SLLB5 Series specification