Hercules 10 Installation and operation manual

10 Zone LED Alarm Panel - Engineering Manual
1
Hercules 10 Zone onboard LED Alarm Panel
Engineering Manual
SAFETY
Before proceeding with the installation, please note the following safety warnings:
DO NOT connect the mains supply directly to the product, this will cause permanent damage to the products.
Control panel is for indoor use only. Avoid mounting location which can expose this product to splashing or dripping
liquid.
Always follow the manufacturer’s advice when using any tools power tools, ladder/steps,. using steps or ladders, and
wear suitable protective equipment (e.g. safety goggles) when drilling holes, etc. The use of ear defenders are advisable
when working in close proximity to the External Siren or the Control Panel’s Siren when the front panel cover is
removed due to the high sound level produced by it. Before drilling holes in walls, check for hidden electricity cables
and water pipes. The use of a cable/pipe locator is advisable if in doubt. Batteries (battery pack or batteries installed)
should not be exposed to excessive heat. Danger of damage to the unit may occur if battery is incorrectly replaced.
Replace only with the same or equivalent type. (Do not mix batteries type).

10 Zone LED Alarm Panel - Engineering Manual
2
Table of Contents
SECTION 1 - OVERVIEW OF SYSTEM ........................................................................... 5
1.1 - Kit Contents.............................................................................................................................. 5
1.2 - Tools Required ......................................................................................................................... 6
1.3 - System Feature......................................................................................................................... 6
1.4 - Explanation of Terms .............................................................................................................. 6
SECTION 2 – INSTALLING YOUR SYSTEM................................................................... 7
2.1 - Fixing the Control Panel ......................................................................................................... 7
2.2 - PCB ........................................................................................................................................... 8
2.3 - Tamper network ...................................................................................................................... 8
2.4 - Remote Keypads ...................................................................................................................... 9
2.5 - Security Zones ........................................................................................................................ 10
2.6 - Fire Zone Circuit.................................................................................................................... 10
2.7 - Tamper Zone Circuit............................................................................................................. 11
2.8 - PA Zone Circuit ..................................................................................................................... 11
2.9 - Extension speaker .................................................................................................................. 11
2.10 - External siren Output (Bell box) ........................................................................................ 12
2.10.1 - Vortex
Ⅱ
wiring to control panel..................................................................................... 13
2.10.2 - Solar bell wiring to control panel.................................................................................... 14
2.10.3 - AD2510 wiring to control panel ..................................................................................... 15
2.11 - 13V Supply Output .............................................................................................................. 15
2.12 - Set .......................................................................................................................................... 15
SECTION 3 - FACTORY DEFAULT SETTING................................................................16
SECTION 4 - MAINS CONNECTION ..............................................................................17

10 Zone LED Alarm Panel - Engineering Manual
3
SECTION 5 - FIRST POWER UP ....................................................................................18
SECTION 6 – HOW TO SET UP THE SYSTEM ..............................................................20
6.1 - How to enter Engineer Program Mode................................................................................ 20
6.2 - Setup Programs...................................................................................................................... 21
6.2.1 - How to go into Full mode Setting..................................................................................... 21
6.2.2 - How to go into Part 1 mode Setting.................................................................................. 21
6.2.3 - How to go into Part 2 mode Setting.................................................................................. 21
6.2.4 - How to set zone function .................................................................................................. 22
6.2.5 - How to set Exit mode function ......................................................................................... 24
6.2.6 - How to set Exit time function ........................................................................................... 25
6.2.7 - How to set Entry time function......................................................................................... 25
6.3 - Setup Zones Type................................................................................................................... 26
6.3.1 - How to set Zone Type....................................................................................................... 26
6.4 - Setup Zones Attrs................................................................................................................... 27
6.5 - Setup Codes ............................................................................................................................ 28
6.5.1 - How to set up/change User Code...................................................................................... 29
6.5.2 - How to delete User Code .................................................................................................. 29
6.6 - Setup system ........................................................................................................................... 30
6.6.1 - How to Setup System Flags .............................................................................................. 30
6.6.2 - How to Setup Bell Time ................................................................................................... 33
6.6.3 - How to Setup Rearm count ............................................................................................... 33
6.6.4 - How to Setup Bell delay time ........................................................................................... 34
6.6.5 - How to Restore to factory value using menu.................................................................... 35
6.7 - View Event Log ...................................................................................................................... 35
6.8 - Test System............................................................................................................................. 36
6.8.1 - How to Test Outputs ......................................................................................................... 36
6.8.2 - How to enter Walk Test .................................................................................................... 37
6.8.3 - How to Exit Engineer Program Menu............................................................................... 37
SECTION 7 - USING SYSTEM........................................................................................38
7.1 - Setting the System .................................................................................................................. 38
7.2 - How to OMIT a zone(s) ......................................................................................................... 39
7.3 - Unsetting the System.............................................................................................................. 39
7.4 - How to UNSET from Alarm and RESET the system ......................................................... 40

10 Zone LED Alarm Panel - Engineering Manual
4
7.5 - How to use Panic Alarm on keypad ..................................................................................... 40
SECTION 8 - MAINTENANCE ........................................................................................41
SECTION 9 - TROUBLESHOOTING GUIDE...................................................................41
SECTION 10 - SPECIFICATIONS ...................................................................................43
APPENDIX 1 – ZONE - LOCATION TABLE ...................................................................44
DISPOSAL AND RECYCLING........................................................................................44
TECHNICAL SUPPORT..................................................................................................44

10 Zone LED Alarm Panel - Engineering Manual
5
POWER
TAMPER
DAY
PA
B
A
ZONE8
ZONE7
ZONE6
ZONE5
ZONE4
ZONE3
ZONE2
ZONE1
PA
FULL
P 2P 1
RESET PROG
9
8
7
65
01234
Section 1 - Overview of System
The 10 zone intruder alarm system is an indoor alarm system based on advanced technology to
give professional levels of protection and reliability. It is 10 zone wired system with special
electronic design for short-circuit protection. It is simple to use, to be installed by special
installation engineer, special tools or training is required.
IMPORTANT – Please read this manual carefully, in full, before commencing Installation.
You will find installation easier if you follow these steps in the sequence shown.
1.1 - Kit Contents
The system comprises of:
10 Zone onboard LED Alarm Panel.
This is the heart of the system. It receives signals from detectors. Accepts input from a user and
activates warning devices such as siren and strobe lights.
Option :
LED REMOTE KEYPAD

10 Zone LED Alarm Panel - Engineering Manual
6
1.2 - Tools Required
• Large and small flat bladed screwdrivers
• Large and small cross-point screwdrivers
• Power drill
• Hammer
• 5mm, 8mm and 10mm masonry drill bits
• Sharp knife
• Wire cutters & wire stripper
•
Ladder or other safe working platform
1.3 - System Feature
10 Zones programmable for Security, PA, Fire, 24Hr Tamper
TAMPER input
Output for External Bell Box and Strobe
4 Access Level Codes, manager code, engineer code, user code (2 user codes), holiday code,
all programmable.
1 Full set and 2 fully selectable part set programs.
Chime on any security zone
16 events memory for LED Keypad
Programmable timers for exit, entry and bell cut off
Walk Test mode
Quick set system
Single Key Set mode
Supports up to four remote LED keypads with on board PA , Keypads positioned up to 100
meters from control panel.
Keypads can be wired in a star configuration from control panel
Single key set
Non-voltage memory for protection of engineer program, manager and event log.
Battery capacity of up to 2.1AH
1.4 - Explanation of Terms
Zone – A logical area that is monitored by one or two or more detectors.
Disarm – It is the normal state of the system when the house is occupied. Enter your four-digit
user PIN code would return to OFF state.
Full Alarm (ARM state) – The CU will sound full alarm (internal siren) when it receives alarm
signals.
Part Arm (Home state) – Arming the system so that certain zones omitted (i.e. will not trigger
an alarm).
Entry/Exit Zone – The CU recognize MC zone as entry and/or exit zone.
OK Beep – Rapid double tone; it indicates correct operation.
Error Beep – Long single tone; it indicates incorrect operation.

10 Zone LED Alarm Panel - Engineering Manual
7
1
Cable entry holes
Mounting holes
Mounting holes
1
2
Section 2 – Installing your System
In choosing a suitable location you should bear in mind:
The need to reach the CU easily, within the 30 seconds, when entering and leaving the
premises, ideally passing only one detector.
The CU should not be visible from the exterior of the protected premises.
2.1 - Fixing the Control Panel
CAUTION: When positioning the control panel ensure that it is located in a dry place
away from damp areas.
Step 1. Remove the front cover(s) from the base
assembly.
Disconnect the transformer wires from the board,
these are marked AC. Carefully remove the board by
gently pushing the holding clips on the bottom edge
of the board and with draw it from the base.
Step 2. Fit the panel to wall with suitable fixings.
Ensure the wall surface is flat to prevent base
distortion. There are cable entry holes provided in
the rear of the base and around the outside edges
through the thinned out plastic sections which may
be cut away as required.
Step 3.The hole provided adjacent to the mains
transformer is a dedicated mains cable entry point.

10 Zone LED Alarm Panel - Engineering Manual
8
2.2 - PCB
There are three fuses mounted on the circuit board. All are 20mm anti-surge
F1 1.6A – to protect the positive (+Ve) line of 12V battery
F2 1A – to protect the RKP 13V supply
F3 1A – to protect the Siren (Bell)&Strobe supply
As supplied, wire links are fitted across the Tamper terminal to represent a closed circuit.
CAUTION: Always power-down the panel when wiring external circuits, to prevent
damage to the panel electronics.
Systematically wire and test each circuit:
• Zone, Tamper circuit and PA circuits
• Finish by wiring any additional extension speaker, sounders, external siren (bell)/strobe and
the 13V supply.
2.3 - Tamper network
The Tamper circuit is used to protect all cables and detectors in the system from unauthorized
access including the panel and RKP covers.
The zone and PA tampers should be series wired and connected to the terminals.
Terminals RTN-&- are for the external siren tamper. The TAMP terminals at the bottom left of
the board are for the RKP tampers.

10 Zone LED Alarm Panel - Engineering Manual
9
2.4 - Remote Keypads
1). Select LED remote keypad jumper
2) Wiring diagram
Keypad 1
Keypad 2
Keypad 3
Keypad 4
Address A
ON OFF ON OFF
Address B
ON ON OFF OFF
To set the address of the Remote Keypads, please apply the jumper links as follows,

10 Zone LED Alarm Panel - Engineering Manual
10
Fitting the Remote Keypad
a. Separate the RKP base plate from the main assembly by slackening the retaining screw.
b. Cut away the required thin wall sections around the edges of the base plate for cable entry.
c. The base plate may be fitted directly to the wall using the screws and wall plugs supplied, if
these are not appropriate for the wall the use suitable alternative fixings.
d. Bring the cables into the base plate and wire to the terminal block on the base plate, see
diagram on the previous page.
e. Refit the RKP main assembly to the base plate by hooking it onto the top holding clips.
Check that the wiring does not foul the tamper switch/spring or the PCB support pillar.
Rescuer the screw in the bottom of the case.
2.5 - Security Zones
PIR and MS connection to the control panel block diagram.
2.6 - Fire Zone Circuit
Any zone may be programmed as a
fire zone. This will automatically
exclude the availability
of the zone from programs and normal
security applications.
MC

10 Zone LED Alarm Panel - Engineering Manual
11
2.7 - Tamper Zone Circuit
Any zone may be programmed as a
Tamper zone. Operational in Day and
set, the Tamper circuit will cause a
full alarm condition when activated.
2.8 - PA Zone Circuit
Any quantity of normally closed type
personal attack button may be wired
in series and then connected to the
PA circuit. Operational in Day and
set, the PA circuit will cause a full
alarm condition when activated. PA
is indicated on the control panel or
RKP as Attack.
2.9 - Extension speaker
Extension speaker may be connected to the loudspeaker terminals to produce high volume alarm
tones and low volume entry/exit/fault tones.
External speaker connects to control panel
16 Ohms Extension Speaker

10 Zone LED Alarm Panel - Engineering Manual
12
Only one 16 ohms extension speaker may be wired across the speaker terminals. Mounted in
convenient positions within the installation the extension speakers will reproduce all of the alarm
tones generated by the control panel.
A control marked VOLUME in the center of the board may be used to adjust the low volume
entry/exit tones to suit environmental conditions.
2.10 - External siren Output (Bell box)
The external siren (bell box) is usually installed in a high position from where the siren could be
seen and heard.
Terminal + S- RTN- - are for connection to the external siren. These terminals provide a
power/hold –off supply, sounder trigger and tamper circuit to protect the external siren housing.
The terminals are summarized as follows:
+ +Ve supply (13V)
S- -Ve Sounder trigger
RTN- -Ve tamper return
- -Ve supply (0)
Strobe - and strobe +
Where a discrete external siren is used, it should be connected to terminals + & S-. Terminals
RTN- & - are then used for tamper protection for the housing.
Bell box wiring to control panel
Bellbox
Yellow
Red
Black
White
Green

10 Zone LED Alarm Panel - Engineering Manual
13
2.10.1 - VortexⅡ
ⅡⅡ
Ⅱwiring to control panel
Board
VORTEX II
Vortex
II
wiring to control panel
TRGRTNHOLD OFF
+
STB
+

10 Zone LED Alarm Panel - Engineering Manual
14
2.10.2 - Solar bell wiring to control panel
Solar bell
Board
+12VGND
F/L F/L
Solar bell wiring to control panel

10 Zone LED Alarm Panel - Engineering Manual
15
2.10.3 - AD2510 wiring to control panel
AD2510 wiring to control panel
2.11 - 13V Supply Output
The 13V output is to power detectors which require a voltage supply (PIR detector etc). The
supply is present at all times and may be used to supply a total of 350mA.
2.12 - Set
The output marked SET becomes positive on correct Set of the system and is removed by entry
of a valid user code.

10 Zone LED Alarm Panel - Engineering Manual
16
Section 3 - Factory Default Setting
Indications on the system
Indications
LED steady on indication
LED flashing indication
LED off
Internal Sound
External Device: Strobe
External Siren: Bell
Defaulting Manager code and Engineer code
- Power off the alarm unit
- Connect a lead wire between terminal [RTN-] and
[SET+]
- Power on the alarm unit. Two beep sound are heard
and All codes are reset
- Clear the siren by keying in the default Manager code
- Remove the lead wire and return to Day mode by pressing <Reset> button
System status
User code 1-2 : Not used
Holiday code : Not used
Manager code : 0123
Engineer code : 9999
Bell time : 14 minutes
Bell delay time : No delay
Rearm Count : 3 Rearms
Zone type : Security
Omit Allowed : Off
Double Knock : Off
Chime : Off
System flag
Silent PA : Off
RKP PA : On
Engineer Reset : Off
PA user Reset : On
Fire user Reset : On
Bell in Fire : On
Disable Bell Tamper : Off
Lock Engineer Code : Off
Auto walk test exit : Off
Key Switch/PTS : Off
PTS as Door Bell : Off
Strobe on SET : On
Single key SET : Off
EOLR zone : Off
EN compliant : Off
SET mode
Full mode:
Zone 1 : Timed
Zone 2 : Inhibited
Zone 3-10 : Immediate
Exit Mode : Timed Exit
Exit Time : 45 sec
Entry Time : 45 sec
Part 1 mode:
Zone 1,2 : Timed
Zone3-8 : Immediate
Zone 9-10 : Not Used
Exit Mode : Timed Exit
Exit Time : 45 sec
Entry Time : 45 sec
Part 2 mode : Disabled

10 Zone LED Alarm Panel - Engineering Manual
17
Section 4 - Mains Connection
The mains power should be connected using a 3 core cable of not less than 1mm sq. from a fused
spur to the mains connector inside the control panel.
NOTE: The mains supply must be connected by a technically competent person and according
to current IEE regulations.
CAUTION: To avoid the risk of electrical shock you must always totally isolate the mains
supply before opening the control panel cover(s).
Mains input fuse rating: 125mA, 250V type.
On connecting the mains supply to the panel the power indicator is lit. Power
Testing the System
Complete the wiring of the system and then:
• Fully test the system and ensure it is fault free.
• Fully program the system.
• Fill in the installation log at the back of the manual and retain if for future reference.
• Finally explain the operation of the system to then end user.

10 Zone LED Alarm Panel - Engineering Manual
18
Section 5 - First Power Up
a. Check that the factory fitted links are connected to terminals TAMP and RTN-& -.
b. Fit the battery wires to the BATT terminals on the Board, Red to +and Black to -.
c. On connecting the battery the system will now go into alarm condition and Day led is
indication.
d. Fit the cover to hold down the tamper spring at the bottom right-hand of the board.
e. Enter User code / Manager code
(factory set code).
Day
PA
TAMP
1
2
3
4
5
6
7
8
9
10
Alarm sound
0 1 2 3
Day
PA
TAMP
1
2
3
4
5
6
7
8
9
10

10 Zone LED Alarm Panel - Engineering Manual
19
f. Press to return to Day mode.
g. Immediately enter the engineer code 9-9-9-9 factory default setting. Or go to page 16 how to
enter program mode. If authorized by manager code.
h. The system will go into Engineer program mode. Under engineer mode, you can program.
Engineer Program Mode
The control panel may be programmed to suit a wide variety of installations.
Once the engineer program mode has been accessed, each configuration may be changed in any
order.
Before entering engineer program mode the system should be in the Day mode, with the Day and
PWR indicators lit.
Day
PA
TAMP
1
2
3
4
5
6
7
8
9
10
R ES TE
Day
PA
TAMP
1
2
3
4
5
6
7
8
9
10

10 Zone LED Alarm Panel - Engineering Manual
20
Section 6 – How to Set up the system
The full menu structure for the panel can only be accessed while in Engineer Program Mode.
The structure is shown in the following table:
6.1 - How to enter Engineer Program Mode
You should require the manager to authorize Engineer access. It is accessed directly form Day
mode via the Engineer code.
To operate the “Enter Engineer operation mode” as follow:
·
Enter Manager program mode.
·
Press
·
Press to authorize Engineer access.
Then Engineer can access program mode
for 1 hours.
·
Press to leave the current menu.
• Input 4-digit Engineer code
to go to engineer operation window.
MENU OPTIONS
1 Setup Programs 5 Setup System
2 Setup Zones Name and Type 6 Misc Menu
3 Setup Zones Attrib 7 View alarm log
4 Setup Codes 8 Test System
Day
PA
TAMP
1
2
3
4
5
6
7
8
9
10
Day
PA
TAMP
1
2
3
4
5
6
7
8
9
10
Day
PA
TAMP
1
2
3
4
5
6
7
8
9
10
P OR G 0 1 2 3
3
R ES TE
9 9 9 9
Day
PA
TAMP
1
2
3
4
5
6
7
8
9
10
R ES TE
Table of contents