HIK VISION DS-2TP03-15VM/W User manual

Handheld Thermography Camera
User Manual
.
UD05641B
0100001070612
COPYRIGHT © 2017 Hikvision. ALL RIGHTS RESERVED

Handheld Thermography Camera ·User Manual
User Manual
COPYRIGHT © 2017 Hangzhou Hikvision Digital Technology Co., Ltd.
ALL RIGHTS RESERVED.
Any and all information, including, among others, wordings, pictures, graphs are
the properties of Hangzhou Hikvision Digital Technology Co., Ltd. or its
subsidiaries (hereinafter referred to be “Hikvision”). This user manual (hereinafter
referred to be “the Manual”) cannot be reproduced, changed, translated, or
distributed, partially or wholly, by any means, without the prior written permission
of Hikvision. Unless otherwise stipulated, Hikvision does not make any warranties,
guarantees or representations, express or implied, regarding to the Manual.
About this Manual
This Manual is applicable to Handheld Thermography Camera.
The Manual includes instructions for using and managing the product. Pictures,
charts, images and all other information hereinafter are for description and
explanation only. The information contained in the Manual is subject to change,
without notice, due to firmware updates or other reasons. Please find the latest
version in the company website (http://overseas.hikvision.com/en/).
Please use this user manual under the guidance of professionals.
Trademarks Acknowledgement
and other Hikvision’s trademarks and logos are the properties of
Hikvision in various jurisdictions. Other trademarks and logos mentioned below
are the properties of their respective owners.
Legal Disclaimer
TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, THE PRODUCT
DESCRIBED, WITH ITS HARDWARE, SOFTWARE AND FIRMWARE, IS PROVIDED
“AS IS”, WITH ALL FAULTS AND ERRORS, AND HIKVISION MAKES NO
WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION,
MERCHANTABILITY, SATISFACTORY QUALITY, FITNESS FOR A PARTICULAR
PURPOSE, AND NON-INFRINGEMENT OF THIRD PARTY. IN NO EVENT WILL
HIKVISION, ITS DIRECTORS, OFFICERS, EMPLOYEES, OR AGENTS BE LIABLE TO
YOU FOR ANY SPECIAL, CONSEQUENTIAL, INCIDENTAL, OR INDIRECT DAMAGES,
INCLUDING, AMONG OTHERS, DAMAGES FOR LOSS OF BUSINESS PROFITS,
BUSINESS INTERRUPTION, OR LOSS OF DATA OR DOCUMENTATION, IN
CONNECTION WITH THE USE OF THIS PRODUCT, EVEN IF HIKVISION HAS BEEN
ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.

Handheld Thermography Camera ·User Manual
REGARDING TO THE PRODUCT WITH INTERNET ACCESS, THE USE OF
PRODUCT SHALL BE WHOLLY AT YOUR OWN RISKS. HIKVISION SHALL NOT
TAKE ANY RESPONSIBILITES FOR ABNORMAL OPERATION, PRIVACY LEAKAGE
OR OTHER DAMAGES RESULTING FROM CYBER ATTACK, HACKER ATTACK,
VIRUS INSPECTION, OR OTHER INTERNET SECURITY RISKS; HOWEVER,
HIKVISION WILL PROVIDE TIMELY TECHNICAL SUPPORT IF REQUIRED.
SURVEILLANCE LAWS VARY BY JURISDICTION. PLEASE CHECK ALL RELEVANT
LAWS IN YOUR JURISDICTION BEFORE USING THIS PRODUCT IN ORDER TO
ENSURE THAT YOUR USE CONFORMS THE APPLICABLE LAW. HIKVISION SHALL
NOT BE LIABLE IN THE EVENT THAT THIS PRODUCT IS USED WITH
ILLEGITIMATE PURPOSES.
IN THE EVENT OF ANY CONFLICTS BETWEEN THIS MANUAL AND THE
APPLICABLE LAW, THE LATER PREVAILS.
Regulatory Information
FCC Information
FCC compliance: This equipment has been tested and found to comply with the
limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful interference
when the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed and
used in accordance with the instruction manual, may cause harmful interference
to radio communications. Operation of this equipment in a residential area is likely
to cause harmful interference in which case the user will be required to correct the
interference at his own expense.
FCC Conditions
This device complies with part 15 of the FCC Rules. Operation is subject to the
following two conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including interference that
may cause undesired operation
EU Conformity Statement
This product and - if applicable - the supplied accessories too are
marked with "CE" and comply therefore with the applicable
harmonized European standards listed under the EMC Directive
2014/30/EU, the RoHS Directive 2011/65/EU.
2012/19/EU (WEEE directive): Products marked with this symbol
cannot be disposed of as unsorted municipal waste in the European
Union. For proper recycling, return this product to your local supplier
upon the purchase of equivalent new equipment, or dispose of it at

Handheld Thermography Camera ·User Manual
designated collection points. For more information see: www.recyclethis.info.
2006/66/EC (battery directive): This product contains a battery that
cannot be disposed of as unsorted municipal waste in the European
Union. See the product documentation for specific battery information.
The battery is marked with this symbol, which may include lettering to
indicate cadmium (Cd), lead (Pb), or mercury (Hg). For proper recycling,
return the battery to your supplier or to a designated collection point. For more
information see: www.recyclethis.info.
Industry Canada ICES-003 Compliance
This device meets the CAN ICES-3 (A)/NMB-3(A) standards requirements.
Safety Instruction
These instructions are intended to ensure that user can use the product correctly
to avoid danger or property loss.
The precaution measure is divided into Warnings and Cautions:
Warnings: Neglecting any of the warnings may cause serious injury or death.
Cautions: Neglecting any of the cautions may cause injury or equipment damage.
Warnings
The device should be used in compliance with local laws and electrical safety
regulations. Refer to the appropriate documentation for detailed information.
The input voltage should conform to IEC60950-1 standard: SELV (Safety Extra
Low Voltage) and the Limited Power Source (12 VDC). Refer to the appropriate
documentation for detailed information.
Make sure the plug is properly connected to the power socket.
If smoke, odor, or noise arises from the device, immediately turn off the power,
unplug the power cable, and contact the service center.
The installer and user are responsible for password and security configuration
and its settings.
Cautions
Do not drop the device or subject it to physical shock.
Warnings Follow these
safeguards to prevent serious
injury or death.
Cautions Follow these
precautions to prevent
potential injury or material
damage.

Handheld Thermography Camera ·User Manual
Wipe the device gently with a clean cloth and a small quantity of ethanol, if
necessary.
Do not aim the lens at the sun or any other bright light.
When any laser equipment is in use, make sure that the device lens is not
exposed to the laser beam, or it may burn out.
Do not expose the device to high electromagnetic radiation or extremely hot,
cold, dusty, or damp environments.
Place the device in a dry and well-ventilated environment.
Keep non-waterproof devices away from liquids.
Keep the device in original or similar packaging while transporting it.
A few device components (e.g., electrolytic capacitor) require regular
replacement. The average lifespan varies, so periodic checking is recommended.
Contact your dealer for details.
Improper use or replacement of the battery may result in explosion hazard.
Replace with the same or equivalent type only. Dispose of used batteries in
conformance with the instructions provided by the battery manufacturer.
Never attempt to disassemble the device.
Safety Instruction
CAUTION: THE PRODUCT IS BUILT IN A REPLACEABLE BATTERY. RISK OF
EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. DISPOSE OF USED
BATTERIES ACCORDING TO THE INSTRUCTIONS.
Laser Light Supplement Warning
Warning: The laser radiation emitted from the
device can cause eye injuries, burning of skin or
inflammable substances. Before enabling the Light
Supplement function, make sure no human or
inflammable substances are in front of the laser
lens.

Handheld Thermography Camera ·User Manual
Table of Contents
About This Manual
Overview of Contents
1Overview
1.1 Box Content
1.1.1 Standard Box Contents
1.1.2 Optional Accessories
1.2 Product Introduction
1.3 Functions
2Appearance
2.1 Dimensions
2.2 Components
3Basic Functions
3.1 Charging the Device
3.2 Power On and Off
3.3 Interface Description
3.4 Focus Lens
3.5 File Exporting
3.6 (Optional) Assembling Lens
3.7 Operation
4Main Configurations
4.1 Temperature Measurement
4.1.1 Thermometry Settings
4.1.2 Thermometry Rule Configuration
4.2 Network Configuration
4.2.1 Wi-Fi Settings
4.2.2 WLAN Hot Spot Settings
4.3 Storage Settings
4.3.1 Recording Settings
4.3.2 Capturing Settings
4.4 Image Configuration
4.4.1 Temperature Difference/Range
4.4.2 Palettes Settings
4.4.3 Thermal/Optical Configuration
4.5 Alarm Configuration
4.6 Other Configurations
4.6.1 Digital Zoom
4.6.2 LED Light Supplement
4.6.3 Laser Settings
4.6.4 Client Software

Handheld Thermography Camera ·User Manual
5System Settings
5.1 Unit Settings
5.2 Display Settings
5.3 Device Initialization
5.4 Device Information
6Appendix
6.1 Common Material Emissivity Reference
6.2 Frequently Asked Questions (FAQ)

Handheld Thermography Camera ·User Manual
1
About This Manual
This document introduces the way to perform and maintain the Handheld
Thermography Camera.
It covers what is Handheld Thermography Camera, how to set up alarm and rules
for Handheld Thermography Camera, concrete functions and descriptions of the
camera. It shows you how to record and capture with the camera, and export the
files. It also advices basic handling methods of frequently happened errors.
Overview of Contents
This document contains the following chapters, and appendixes:
Chapter 1 Overview introduces the handheld Thermography camera,
including the box content, product introduction, and major functions.
Chapter 2 Appearance shows the dimensions of the camera and explains
the functions of all components.
Chapter 3 Basic Functions describes how to charge, power on and off the
camera, focus the thermal lens, and export file. It also tells the lens
assembling procedure and how to operate it with touch-screen and by
buttons.
Chapter 4 Main Configurations shows you the way to measure temperature
and set temperature alarms. Besides, it describes how to record videos and
capture snapshots. You can do Wi-Fi settings, palettes selection,
temperature section settings, digital zoom, LED light control, and remote
control via client software according to this chapter.
Chapter 5 System Settings indicates the unit settings, display settings, and
device initialization, etc.
Chapter 6 Appendix lists the emissivity value of common materials for
reference and the frequently asked questions.

Handheld Thermography Camera ·User Manual
2
1Overview
1.1 Box Content
See the table below for the box content.
1.1.1 Standard Box Contents
Handheld Thermography Camera (× 1)
Charging Base (× 1)
Sun Shield (× 1)
Battery (× 1)
USB Cable (× 1)
Tripod Adapter (×1)
DISK
User Manual (× 1)
Disk (× 1)

Handheld Thermography Camera ·User Manual
3
1.1.2 Optional Accessories
Lens (× 1)
Power Adapter (× 1)
1.2 Product Introduction
The handheld Thermography camera is a camera with both optical
images and thermal images. It can do thermometry, video
recording, snapshot capturing, alarm, and it can connect to Wi-Fi.
The built-in high-sensitivity IR detector and high-performance
sensor detects the variation of temperature and measure the
real-time temperature.
The Picture-in-picture technique of the Thermography camera and
the fusion of optical view and thermal view, enhances the details of
the images display. It supports multiple palettes and alarm types.
When the detected temperature in the scene does not match with
the alarm rules, the device alarms by color of the palette mode
automatically. It helps the users to find the risky part and lower
your property loss. The device supports Wi-Fi connection, live
viewing, recording, and capturing, etc.
The handheld Thermography camera is easy to use, and adopts
ergonomic design. It is widely applied to substations, electricity
prevention detection of companies, and reconnaissance survey of
construction field.
1.3 Functions
Thermometry

Handheld Thermography Camera ·User Manual
4
Device detects the real-time temperature, and display it on the
screen.
Storage
Device is equipped with built-in memory module to store recorded
videos, captured snapshots, and important data.
Fusion
Device can display fusion of thermal view and optical view.
Palette and Alarm
Device supports multiple palettes, and you can set the palette
mode according to the alarm function
Wi-Fi Function
Device can be connected to Wi-Fi. You can connect the device via
Wi-Fi hot spot, and you can view live view, capture, and recording,
etc.
Digital Zoom
Device supports 2× and 4× digital zoom.
LED Light:
LED light supplement makes the device a torch in required
scenarios.
Laser Light Supplement:
Long-distance laser light supplement.

Handheld Thermography Camera ·User Manual
5
2Appearance
2.1 Dimensions
2.2 Components
Touch-Screen
LED Indicator
Navigation
ON/OFF
Laser
Lens Sheet
Back

Handheld Thermography Camera ·User Manual
6
LED Light
Supplement
Laser
Optical Lens
USB Cover
Thermal Lens
Focus Knob
Tripod Interface
Trigger
Battery
Laser Button
Hold the Laser button to turn on laser, and
release the button to turn off laser.
Navigation Button
Menu Button:
-Press the ▽, △, ▷, and ◁button to
select parameters.
-Press the OK button to confirm.
Non-Menu Button:
-Press the △button to turn on/off the
LED light supplement.
-Hold the ▽button to digital zoom.
Lens Sheet Button
Cover the lens to perform the correction.
Back Button
Exit the menu or return to previous menu.
Focus Knob
Adjust lens focal length, refer to 3.4 Focus
Lens.
Trigger
Pull the trigger to record videos or capture
snapshots.
USB Cover
Connect the camera to your PC via USB
cable to export files.
Warning:
The laser radiation emitted from the device can cause eye injuries, burning
of skin or inflammable substances. Before enabling the Light Supplement
function, make sure no human or inflammable substances are in front of
the laser lens.

Handheld Thermography Camera ·User Manual
7
3Basic Functions
3.1 Charging the Device
Note: Please charge the camera with the USB cable and power adapter
supplied by the manufacturer (or according to the input voltage from the
specifications).
Battery
Steps:
1. Hold the camera, and press both battery lock catches of the
Thermography camera, see figure below.
Battery Lock Catch Handheld Camera
Battery Base

Handheld Thermography Camera ·User Manual
8
2. Hold the lock catches, and draw the battery base to take out the
battery, see figure below.
3. Insert the battery into the charging base, see figure below.
Charging Base
Battery
POWER Indicator
4. When the battery is fully charged, draw the battery from the
charging base.
5. Align the ribbed piece on battery with the notch of the camera,
and insert the battery into the camera, see figure below.
Ribbed Piece

Handheld Thermography Camera ·User Manual
9
Note: When the camera is turned on, the OSD (on-screen display) shows
the battery status. When you see the low battery status, charge the
camera and ensure it’s working properly.
POWER Indicator Status
●
Solid Red
Battery is properly charged.
Flash Red
Error occurred.
●
Solid Green
Battery is fully charged.
●
Off
Battery is not charged.
3.2 Power On and Off
Power On
Remove the lens cover, and hold the button for over three
seconds to turn on the device.
Power Off
When the monocular is turned on, hold the button for three
seconds to power off the device.

Handheld Thermography Camera ·User Manual
10
3.3 Interface Description
In the observation interface, tap the screen or press OK button to
show the menu bar, see figure below.
Real-time
Temperature
Max.
Temperature
Display
Center
Temperature
Display Min. Temperature
Display
Status Icons
Color-Temperature
Scale
Menu Icons
For the descriptions of the menu buttons, see the table below.
Settings
In the Local Settings ( ) interface, you
can set basic parameters, including
thermometry units and range, fuse
settings, and select the lens.
Capture/Record
You can set the device to capture/record
mode.
Thermal/Optical
In the Thermal/Optical Settings ( )
interface, you can set the display to
thermal/optical/PIP/combined (fuse)
modes.
Thermometry
In the Thermometry Rule Configuration
() mode, you can measure the
real-time temperature by rules.
Palettes
You can set the palettes of the display
and the device displays accordingly.
Image
In the Temperature Difference/Range
Settings ( ) interface,
LED Light
LED light supplement makes the device
a torch in required scenarios.

Handheld Thermography Camera ·User Manual
11
For the descriptions of the status icons, see the table below.
USB
This icon shows whether the device is
connected to PC via USB interface.
Wi-Fi
This icon shows whether the device is
connected to Wi-Fi or not.
Hot Spot
This icon show whether the device hot spot is
enabled or not.
SD Card
This icons shows that the device memory card
has short free space.
Battery
This icon shows the battery status of the device.
Unit
This icon shows which unit the device is using
now: ° C, ° F, or Kelvin.
3.4 Focus Lens
Before you start:
Adjust the lens focal length properly before you set any other
configurations, or it may affect the image display and temperature
accuracy.
Steps:
1. Power on the handheld Thermography camera.
2. Aim the camera lens to the appropriate scene.
3. Adjust the focus knob clockwise or anticlockwise, see figure
below.

Handheld Thermography Camera ·User Manual
12
Do NOT touch the lens to avoid affecting the display effect.
3.5 File Exporting
Purpose:
Connect the handheld Thermography camera to your PC with USB
cable, you can export the recorded videos and captured snapshots.
Steps:
1. Open the USB cover.
2. Connect the camera to your PC with USB cable and open the
detected disk.
3. Enter USB > picture and USB > record to view the videos and
snapshots.
-Select and copy the videos to PC and play the file with the
player.
-Select and copy the snapshots to PC and view the files.
4. Disconnect the device from your PC.
Note: For the first time connection, the driver will be installed
automatically.
3.6 (Optional) Assembling Lens
Before you start:
Three thermal lens (not supplied) are optional for the
Thermography camera. For different scene, purchase the lens
accordingly.

Handheld Thermography Camera ·User Manual
13
Steps:
1. Select the proper lens.
2. Install the lens onto the camera.
3. Turn on the camera and go to Local Settings > Lens Selection.
4. Set the lens parameters. For 2× lens, set it to 2× , and for 1/2×
lens, set it to 1/2× , etc.
3.7 Operation
The camera supports both touch-screen control and button
control.
Touch-screen control
Tap on the screen to set parameters and configurations.
Button control
Press the navigation buttons to set parameters and
configurations.
Table of contents