HIRED-HAND, INC. •1733 County Road 68 •Bremen, AL 35033 USA •Phone 256-287-1000 •Fax 256-287-2000
Manual Part No. 4801-0176 rev 9-08 Page 1of 2
MEG
A
-FLOW 24 INCH
ORIFICE STIR F
A
NS
WARNING!
1. Only qualified electrician personnel familiar with the
construction and operation of this equipment and the
hazards involved should install and/or service this
equipment. It is important that all standard electrical
codes be observed when wiring the fan. Read and
understand all instructions and diagrams before
proceeding. Failure to observe this precaution could
result in equipment damage, severe bodily injury, or
loss of life.
2. Disconnect power source before installing or servicing
fan. Failure to disconnect power source can result in
property damage, serious injury, or death.
3. When connected to an automatic controller, FAN MAY
START AT ANY TIME.
4. IMPORTANT! Before Operating Fan, Inspect Fan For
any Object That May Obstruct Blade Rotation.
5. When this fan is used in a life support ventilation system
where failure could result in loss or injury, the user
should provide adequate backup ventilation or accept
the risk of such loss or injury.
DESCRIPTION
Installation and wiring of the Hired Hand Mega-Flow
24” Orifice Stir Fan is quick and simple. Figure 1
shows the 24 inch Stir Fan. Figure 2 shows a Stir Fan
typical installation. Figure 3 shows how the Stir Fan
must be mounted to allow proper operation.
Part # Description Model
6603-4400 Mega-Flow 24 inch
Orifice Stir Fan MF-24O-D-S-SE-.33V-24*S-
0-0-0-0-A
MAINTENANCE
•Read WARNING statements before proceeding.
•Blades, motor, and wire guards should be cleaned
periodically to decrease vibration and ensure maximum fan
life. Remove dirt with a dry brush or compressed air. DO
NOT SPRAY MOTOR WITH WATER OR CLEANING
FLUIDS.
•Fan performance may be greatly reduced by damaged or
dirty shutters (if applicable). Clean and inspect shutter
periodically to ensure maximum fan performance.
BEFORE INSTALLATION
•Inspect fan for damage in transit. Check for loose, missing,
or damaged parts.
•If there are any missing parts or if there is any shipping
damage, do not attempt to operate fan. Contact your
Distributor.
WARRANTY
Your fan has been manufactured with the finest materials and
components available, and is backed by a one year warranty
against electrical and mechanical defects in material and
workmanship. If this fan fails to operate during this period,
return it prepaid to the place of purchase for repair or
replacement without charge at the manufacture’s option.
Damage by accident or abuse is not covered by this warranty.
This warranty gives you specific legal rights and you may have
other rights that vary from state to state.
Figure 2:
24 inch Stir Fans
Installed
Figure 1:
24 inch Stir Fan
A
GRICULTURAL HEATING
& VENTILATION SYSTEMS
Total Systems, Total Control
HIRED-HAND, INC. •1733 County Road 68 •Bremen, AL 35033 USA •Phone 256-287-1000 •Fax 256-287-2000
Manual Part No. 4801-0176 rev 9-08 Page 2of 2
Mega-Flow 24” Orifice Stir Fan
DIMENSIONS
30.25”
Vertical
30.25” Horizontal
24 inch Stir Fan
Installation
A. Orifice fans are intended to be securely mounted by
hanging from a chain or cable but may be installed in a
wall.
B. DO NOT install fan within 7 feet of floor or in reach of
personnel or livestock.
C. FAILURE TO GUARD MOVING PARTS MAY RESULT IN
SERIOUS INJURY OR DEATH.
D. Disconnect AC electrical power from all equipment.
E. Make wire connections to the fan as shown on the fan
motor wiring label and in the controller manual.
F. Mount the 24” stir fans as shown in the diagram in Figure
3.
G. Ensure that all wires near the fan are secured and safely
clear from the fan blades.
H. Apply power and test the controller and fans to ensure
proper operation.
IMPORTANT! INSPECT FAN FOR ANY OBJECT THAT
MAY OBSTRUCT BLADE ROTATION.
Figure 3 Fan Mounting Diagram
WARNING!
•WIRING MUST BE
SECURED TO PREVENT
ENTANGLEMENT WITH
THE FAN BLADES.
•Remove ALL Electrical
Power before
installation/wiring.
WARNING!
Secure fan ONLY to a
ceiling with strength to
support the fan weight and
vibrations.
IMPORTANT:
Tilt the fan upward 2 inches from the
vertical plane in the direction shown.
WARNING!
Remove ALL Electrical Power from the system before
installation / wiring.

This manual suits for next models

1

Other HIRED-HAND Fan manuals

HIRED-HAND MEGA FLOW 48" User manual

HIRED-HAND

HIRED-HAND MEGA FLOW 48" User manual

HIRED-HAND Mega Flow Slantwall User manual

HIRED-HAND

HIRED-HAND Mega Flow Slantwall User manual

HIRED-HAND Econo-Flow User manual

HIRED-HAND

HIRED-HAND Econo-Flow User manual

HIRED-HAND Econo-Flow User manual

HIRED-HAND

HIRED-HAND Econo-Flow User manual

HIRED-HAND Super-Saver Bunsen Jet User manual

HIRED-HAND

HIRED-HAND Super-Saver Bunsen Jet User manual

HIRED-HAND Econo-Flow User manual

HIRED-HAND

HIRED-HAND Econo-Flow User manual

HIRED-HAND MEGA-FLOW CONE FAN User manual

HIRED-HAND

HIRED-HAND MEGA-FLOW CONE FAN User manual

HIRED-HAND Mega-Flow MF-24O-D-S-SE Series User manual

HIRED-HAND

HIRED-HAND Mega-Flow MF-24O-D-S-SE Series User manual

HIRED-HAND Mega Flow 6603-7109 User manual

HIRED-HAND

HIRED-HAND Mega Flow 6603-7109 User manual

HIRED-HAND Mega Flow Slantwall User manual

HIRED-HAND

HIRED-HAND Mega Flow Slantwall User manual

HIRED-HAND Mega-Flow Butterfly User manual

HIRED-HAND

HIRED-HAND Mega-Flow Butterfly User manual

HIRED-HAND Econo-Flow Instruction Manual

HIRED-HAND

HIRED-HAND Econo-Flow Instruction Manual

HIRED-HAND MEGA FLOW Use and care manual

HIRED-HAND

HIRED-HAND MEGA FLOW Use and care manual

HIRED-HAND Funnel Flow 36 User manual

HIRED-HAND

HIRED-HAND Funnel Flow 36 User manual

Popular Fan manuals by other brands

WAC Lighting Clean F-003 installation instructions

WAC Lighting

WAC Lighting Clean F-003 installation instructions

Boneco F50 manual

Boneco

Boneco F50 manual

Faro Barcelona Timor manual

Faro Barcelona

Faro Barcelona Timor manual

Fanimation AIREFLEX LP7675 Series manual

Fanimation

Fanimation AIREFLEX LP7675 Series manual

V-TAC VT-3042-3 instruction manual

V-TAC

V-TAC VT-3042-3 instruction manual

RUSTA 907512030101 user manual

RUSTA

RUSTA 907512030101 user manual

NuTone 764BN manual

NuTone

NuTone 764BN manual

Premisys MP Installation, operation and maintenance manual

Premisys

Premisys MP Installation, operation and maintenance manual

emerio FN-114201 instruction manual

emerio

emerio FN-114201 instruction manual

EG Homevent VIGO 550A Installation & maintenance manual

EG

EG Homevent VIGO 550A Installation & maintenance manual

Craftmade Outdoor Pro Plus OP52 installation guide

Craftmade

Craftmade Outdoor Pro Plus OP52 installation guide

Craftmade Helios HE52-LED installation guide

Craftmade

Craftmade Helios HE52-LED installation guide

NuTone QTXEN080FLT instruction manual

NuTone

NuTone QTXEN080FLT instruction manual

Fanaway EVO2 Installation instructions manual

Fanaway

Fanaway EVO2 Installation instructions manual

Hunter 23970 Owner's guide and installation manual

Hunter

Hunter 23970 Owner's guide and installation manual

Panasonic FV-10VEC2 Service manual

Panasonic

Panasonic FV-10VEC2 Service manual

Kooper Aria instruction manual

Kooper

Kooper Aria instruction manual

Rowenta AIR FORCE INTENSE user guide

Rowenta

Rowenta AIR FORCE INTENSE user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.