11.4.1 Distance protection zones, quadrilateral characteristic ZMQPDIS .................................102
11.4.1.1 Measuring the operating limit of set values................................................................105
11.4.1.2 Measuring the operating time of distance protection zones.......................................105
11.4.1.3 Completing the test.................................................................................................... 106
11.4.2 Phase selection, quad, fixed angle, load encroachment FDPSPDIS .............................106
11.4.2.1 Measuring the operating limit of set values................................................................108
11.4.2.2 Completing the test.................................................................................................... 108
11.4.3 Full scheme distance protection, mho characteristic ZMHPDIS .................................... 108
11.4.3.1 Phase-to-phase faults................................................................................................ 109
11.4.3.2 Phase-to-earth faults ................................................................................................. 110
11.4.4 Faulty phase identification with load encroachment FMPSPDIS ....................................110
11.4.5 Distance protection zones, quadrilateral characteristic, separate settings ZMRPDIS.....110
11.4.5.1 Measuring the operating limit of set values ............................................................... 113
11.4.5.2 Measuring the operating time of distance protection zones ...................................... 114
11.4.6 Phase selection, quadrilateral characteristic with settable angle FRPSPDIS................. 114
11.4.6.1 Measuring the operating limit of set values................................................................ 116
11.4.6.2 Completing the test.................................................................................................... 117
11.4.7 High speed distance protection zones, quadrilateral and mho characteristic
ZMFPDIS ........................................................................................................................117
11.4.7.1 Function revision history.............................................................................................117
11.4.7.2 Verifying the settings.................................................................................................. 118
11.4.7.3 Measuring the operating limit of set values ...............................................................120
11.4.7.4 Measuring the operating time of distance protection zones.......................................121
11.4.7.5 Completing the test.................................................................................................... 121
11.4.8 High Speed distance for series compensated line zones, quadrilateral and mho
characteristic ZMFCPDIS ...............................................................................................121
11.4.8.1 Function revision history............................................................................................ 121
11.4.8.2 Verifying the settings.................................................................................................. 122
11.4.8.3 Measuring the operating limit of set values ...............................................................125
11.4.8.4 Measuring the operating time of distance protection zones.......................................125
11.4.8.5 Transient directional element..................................................................................... 125
11.4.8.6 Completing the test.................................................................................................... 126
11.4.9 Power swing detection, blocking and unblocking ZMBURPSB.......................................126
11.4.9.1 Function revision history............................................................................................ 126
11.4.9.2 Verifying the signal and settings.................................................................................126
11.4.9.3 Completing the test.................................................................................................... 132
11.4.10 Power swing logic PSLPSCH..........................................................................................132
11.4.10.1 Function revision history............................................................................................ 132
11.4.10.2 Testing the carrier send and trip signals.....................................................................133
11.4.10.3 Testing the influence of the residual overcurrent protection.......................................133
11.4.10.4 Checking the underreaching zone............................................................................. 134
11.4.10.5 Completing the test.................................................................................................... 134
11.4.11 Pole slip protection PSPPPAM........................................................................................134
11.4.11.1 Verifying the settings.................................................................................................. 134
11.4.11.2 Completing the test.................................................................................................... 137
11.4.12 Out-of-step protection OOSPPAM ..................................................................................137
Table of contents 1MRK 504 165-UEN Rev. K
4Transformer protection RET670
Commissioning manual
© 2017 - 2022 Hitachi Energy. All rights reserved