  9. Hitachi E-52XN2 User manual

Hitachi E-52XN2 User manual

This manual suits for next models

5

Other Hitachi Fan manuals

Hitachi KPI-252E4E Owner's manual

Hitachi

Hitachi KPI-252E4E Owner's manual

Hitachi HEF-110M User manual

Hitachi

Hitachi HEF-110M User manual

Hitachi RPI-2.0FSN3E User manual

Hitachi

Hitachi RPI-2.0FSN3E User manual

Hitachi RCIM-0.4FSRE User manual

Hitachi

Hitachi RCIM-0.4FSRE User manual

Hitachi RPI-0.4FSN5E User manual

Hitachi

Hitachi RPI-0.4FSN5E User manual

Hitachi KPI User manual

Hitachi

Hitachi KPI User manual

Hitachi RPIM-0.8FSN2E User manual

Hitachi

Hitachi RPIM-0.8FSN2E User manual

Hitachi P-AP56NAM User manual

Hitachi

Hitachi P-AP56NAM User manual

Hitachi RPI-1.5FSRE User manual

Hitachi

Hitachi RPI-1.5FSRE User manual

Hitachi UF 18DSL User manual

Hitachi

Hitachi UF 18DSL User manual

Hitachi UF 18DSL User manual

Hitachi

Hitachi UF 18DSL User manual

Hitachi ESP-T2000R User manual

Hitachi

Hitachi ESP-T2000R User manual

Hitachi airCore 700 Instruction Manual

Hitachi

Hitachi airCore 700 Instruction Manual

Popular Fan manuals by other brands

Minka Group minkaAire Wave F843 instruction manual

Minka Group

Minka Group minkaAire Wave F843 instruction manual

Airflow Adroit DV50 instruction manual

Airflow

Airflow Adroit DV50 instruction manual

Vornado 270 Series owner's guide

Vornado

Vornado 270 Series owner's guide

comfort air TH-10D instruction manual

comfort air

comfort air TH-10D instruction manual

Livoo DOM386 instruction manual

Livoo

Livoo DOM386 instruction manual

Holmes BLIZZARD HAOF-90 owner's guide

Holmes

Holmes BLIZZARD HAOF-90 owner's guide

Taurus GRECO 16 ELEGANCE manual

Taurus

Taurus GRECO 16 ELEGANCE manual

Quorum PINNACLE installation instructions

Quorum

Quorum PINNACLE installation instructions

Monte Carlo Fan Company 3DIR58RBD-V1 Owner's guide and installation manual

Monte Carlo Fan Company

Monte Carlo Fan Company 3DIR58RBD-V1 Owner's guide and installation manual

Craftmade UH52 installation guide

Craftmade

Craftmade UH52 installation guide

Jocel JVA030658 instruction manual

Jocel

Jocel JVA030658 instruction manual

MIKA MFB1211/GR user manual

MIKA

MIKA MFB1211/GR user manual

Harbor Breeze RLG52NWZ5L manual

Harbor Breeze

Harbor Breeze RLG52NWZ5L manual

Allen + Roth L1405 instruction manual

Allen + Roth

Allen + Roth L1405 instruction manual

ViM KUBAIR F400 ECOWATT Technical manual

ViM

ViM KUBAIR F400 ECOWATT Technical manual

HIDRIA R10R-56LPS-ES50B-04C10 user guide

HIDRIA

HIDRIA R10R-56LPS-ES50B-04C10 user guide

BLAUBERG Ventilatoren CENTRO-M 100 L user manual

BLAUBERG Ventilatoren

BLAUBERG Ventilatoren CENTRO-M 100 L user manual

Triangle Engineering HEAT BUSTER SPL Series owner's manual

Triangle Engineering

Triangle Engineering HEAT BUSTER SPL Series owner's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

INSTALLATION MANUAL FOR MULTI-KITS
Line Branch Models:
E-52XN2, E-102XN2, E-162XN2, E-202XN2, E-242XN2,
E-322XN2
NOTE:
Hand over this installation manual to the next installation work
personnel.
1APPLICABLE OUTDOOR UNITS
These multiple pipe connecting kits can be applied to the R410A SET-FREE
series.
CAUTION:
-Do NOT put any material on the product.
2BEFORE INSTALLATION
Confirm the number of the following parts by referring to the model printed
on the package before unpacking.
Do NOT put any foreign material into the parts.
Check to confirm that no foreign materials are inside the parts before
installation.
NOTE:
If any of these parts is not contained, please contact your distributor.
3INSTALLATION WORK
3.1. PIPING CONNECTION SIZE
The ends of the multi-kits are finished as shown in the following figures.
Cut the end of the pipe to meet with the pipe size.
E-52XN2 E-102XN2
GAS LINE
(LOW)
GAS LINE
(HIGH)
LIQUID LINE
E-162XN2 E-202XN2
GAS LINE
(LOW)
GAS LINE
(HIGH)
LIQUID LINE
E-242XN2 E-322XN2
GAS LINE
(LOW)
GAS LINE
(HIGH)
LIQUID LINE
Name of parts E-
52XN2
E-
102XN2
E-
162XN2
E-
202XN2
E-
242XN2
E-
322XN2 Figure
Insulation for
Gas Line (Low) 1 1 1 1 1 1
Insulation for
Gas Line (High) 1 1 1 1 1 1
Insulation for
Liquid Line 1 1 1 1 1 1
Tape 3 3 3 3 3 3
CAUTION:
-Piping shall be supported with adequate space.
-Bent pipes and bypass piping (horizontal loop) shall also be installed
in order to absorb piping elasticity caused by temperature changes.
Unit: mm, ID: Inner Diameter
To Main
Piping
To Indoor
Unit
To
Outdoor
Unit
To Main
Piping
To Indoor
Unit
To
Outdoor
Unit
To Main
Piping
To Indoor
Unit
To
Outdoor
Unit
(x2)
To Main
Piping
To Indoor
Unit
To
Outdoor
Unit
To Main
Piping
To Indoor
Unit
To
Outdoor
Unit
To Main
Piping
To Indoor
Unit
To
Outdoor
Unit
Unit: mm, ID: Inner Diameter
To Main
Piping
To Indoor
Unit
To
Outdoor
Unit
To Main
Piping
To Indoor
Unit
To
Outdoor
Unit
To Main
Piping
To Indoor
Unit
To
Outdoor
Unit
To Main
Piping
To Indoor
Unit
To
Outdoor
Unit
To Main
Piping
To Indoor
Unit
To
Outdoor
Unit To Main
Piping
To Indoor
Unit
To
Outdoor
Unit
Unit: mm, ID: Inner Diameter
To Main
Piping
To Indoor
Unit
To
Outdoor
Unit
To Main
Piping
To Indoor
Unit
To
Outdoor
Unit
To Main
Piping
To Indoor
Unit
To
Outdoor
Unit
To Main
Piping
To Indoor
Unit
To
Outdoor
Unit
To Main
Piping
To Indoor
Unit
To
Outdoor
Unit
To Main
Piping
To Indoor
Unit
To
Outdoor
Unit
(x2)
Библиотека СОК 
3.2. INSTALLATION POSITION
1. Horizontal Installation
Locate the branch pipes on the same horizontal plane.
(Inclination within 30º)
Make the straight length a minimum of 0.5m after the vertical bend.
2. Vertical Installation
Straight length of the pipe connection on the outdoor unit side is made as
follows:
a) The collective pipe connection part is installed upward, the straight
length must be min. 0.5m.
b) The collective pipe connection part is installed downward, the straight
length must be min. 0.3m.
3.3. CONNECTION PROCEDURE FOR PIPING JOINT
When connecting liquid piping for the unit with a capacity 2.0HP or smaller,
and with the length of piping is 15 meters or longer, apply the piping size of
Ø9.53mm.
Fix the connecting pipe as shown in the below figure.
Use the insulation attached to the indoor unit.
3.4. PIPING CONNECTION
1. Use clean copper pipes without any moisture or foreign materials on inner
surface of pipes. When connecting refrigerant pipe, cut the copper pipes
with a pipe cutter as shown below.
Also blow the pipes with nitrogen or air to remain no dust inside the pipe.
Do NOT use a saw, a grindstone or others which causes a large amount
of cutting powder.
2. When cutting the pipe, secure the adequate depth for brazing as shown in
the following table.
(mm)
A: Outer Diameter B: Minimum depth
Over 5, below 8 6
Over 8, below 12 7
Over 12, below 16 8
Over 16, below 25 10
Over 25, below 35 12
Over 35, below 45 14
CAUTION for Refrigerant Piping:
3. Make sure that the stop valves are closed completely.
4. Blow the inside of the pipes with nitrogen when brazing.
DANGER:
Check for the refrigerant leakage in detail. If a large refrigerant leakage
occurs, it will cause difficulty with breathing or harmful gases would
occur if a fire were being used in the room.
5. The airtight test pressure of this product is 4.15MPa.
6. Apply the insulation supplied with these multi-kits to each branch (liquid
side and gas side) with a tape. Also apply the field-supplied insulation to
the field-supplied pipes.
NOTE:
When polyethylene foam is applied, a thickness of 10mm for the liquid
piping and 15mm to 20mm for the gas piping is recommended. (Use
insulation for gas piping with a heat resistance of 100

C).
CAUTION:
-When the temperature of the piping decrease to room temperature,
perform insulation work. If insulation work is performed immediately
after brazing, insulation can melt.
-If the ends of piping system are open to the atmosphere for a while
after accomplishing piping work, securely put caps or vinyl bags to
the ends of the piping, avoiding the intrusion of moisture and dust.
-After installing work has been finished, it is recommended to keep
this manual by a customer.
GB, PMML0210A rev.1 - 01/11
Horizontally
Upward
Downward
INCORRECT
Inclination
within 30º
Inclination
(View from A)
Upward
Expander for Liquid Line (Accessory)
Flare the pipe after inserting the flare nut
Use the flare nut of the indoor unit Fix this part with the attached cord band
or field-supplied vinyl tape
Insulate this part with the
attached insulation
Field-supplied Refrigerant Piping
Field-supplied Insulation
Brazing
Insulation attached to indoor unit
Pipe Cutter
Pipe
Connection
Part
Burring
Downward
B
A
When installing pipe through the wall,
secure a cap at the end of the pipe.
Attach a cap
or vin
y
l ta
p
eCORRECT
INCORRECT
Attach a cap
or vin
y
l ta
p
e
CORRECT INCORRECT
Do NOT place the pipe directly on
the ground.
Attach a cap
or vinyl tape
with rubber
band
CORRECT INCORRECT
Rain water
can enter
Insulation (Field-supplied)
Do NOT leave a gap
between the insulation
Insulation for Gas and
Liquid Line (Accessory)
Fix the insulation with
tape (accessory) completely
after ta
p
in
g
tem
p
orar
y
Indoor
Unit
0.5m
CORRECT
Straight Length
Min. 0.3m
Straight Length
Min. 0.5m