Important User Information
Disclaimer
The information in this document is for informational purposes only. Please inform HMS Industrial
Networks of any inaccuracies or omissions found in this document. HMS Industrial Networks disclaims
any responsibility or liability for any errors that may appear in this document.
HMS Industrial Networks reserves the right to modify its products in line with its policy of continuous
product development. The information in this document shall therefore not be construed as a
commitment on the part of HMS Industrial Networks and is subject to change without notice. HMS
Industrial Networks makes no commitment to update or keep current the information in this document.
The data, examples and illustrations found in this document are included for illustrative purposes and are
only intended to help improve understanding of the functionality and handling of the product. In view of
the wide range of possible applications of the product, and because of the many variables and
requirements associated with any particular implementation, HMS Industrial Networks cannot assume
responsibility or liability for actual use based on the data, examples or illustrations included in this
document nor for any damages incurred during installation of the product. Those responsible for the use
of the product must acquire sufficient knowledge in order to ensure that the product is used correctly in
their specific application and that the application meets all performance and safety requirements
including any applicable laws, regulations, codes and standards. Further, HMS Industrial Networks will
under no circumstances assume liability or responsibility for any problems that may arise as a result from
the use of undocumented features or functional side effects found outside the documented scope of the
product. The effects caused by any direct or indirect use of such aspects of the product are undefined
and may include e.g. compatibility issues and stability issues.
Anybus®Managed Industrial L3 Switch Startup Guide SP2556 1.1 en-US

Anybus®Managed Industrial L3 Switch Startup Guide SP2556 1.1 en-US
Table of Contents Page
1 Preface ..................................................................... 3
1.1 About This Document . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.2 Document Conventions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.3 Trademarks. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
2 Safety ...................................................................... 4
2.1 Intended Use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
2.2 General Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
3 Preparation ................................................................ 5
3.1 Package Checklist . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
3.2 Support and Resources . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
4 Installation................................................................. 6
4.1 DIN Rail Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
4.2 Connecting Ground Screw . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
4.3 Terminal Block Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
4.4 Installing Terminal Block. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
4.5 Connecting Digital Output Wires . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
4.6 Connecting Digital Input Wires . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
4.7 Connecting Power Wires . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
4.8 Connecting to Ethernet Network . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
4.9 Connecting to Fiber Network . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
5 Configuration .............................................................15
5.1 Before You Begin Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
5.2 Web Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
5.3 Console Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
5.4 USB Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
5.5 Factory Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

Anybus®Managed Industrial L3 Switch Startup Guide SP2556 1.1 en-US
6 Verify Operation..........................................................19
6.1 System LED Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
6.2 Ethernet LED Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
6.3 SFP Port LED Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
7 Technical Data ............................................................22
7.1 Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

Preface 3 (24)
1 Preface
1.1 About This Document
This manual describes how to install Anybus Managed Industrial L3 Switch and
set up a basic configuration.
For additional documentation and software downloads, FAQs, troubleshooting
guides and technical support, please visit www.anybus.com/support.
1.2 Document Conventions
The following conventions are used to indicate safety information and other
important content in this document:
WARNING
Instruction that must be followed to avoid a risk of death or serious injury.
Caution
Instruction that must be followed to avoid a risk of personal injury.
Instruction that must be followed to avoid a risk of reduced functionality
and/or damage to the equipment, or to avoid a network security risk.
Additional information which may facilitate installation and/or operation.
1.3 Trademarks
Anybus®is a registered trademark of HMS Industrial Networks. All other
trademarks mentioned in this document are the property of their respective
holders.
Anybus®Managed Industrial L3 Switch Startup Guide SP2556 1.1 en-US

Safety 4 (24)
2 Safety
2.1 Intended Use
The intended use of this equipment is as a communication interface and
gateway. The equipment receives and transmits data on various physical levels
and connection types.
If this equipment is used in a manner not specified by the manufacturer, the
protection provided by the equipment may be impaired.
2.2 General Safety
Caution
Ensure that the power supply is turned off before connecting it to the
switch.
Connecting power with reverse polarity or using the wrong type of power
supply may damage the equipment. Make sure that the power supply is
connected correctly and of the recommended type.
Anybus®Managed Industrial L3 Switch Startup Guide SP2556 1.1 en-US

Preparation 5 (24)
3 Preparation
3.1 Package Checklist
Item Pieces
Product unit (without SFP transceiver) 1
8 pin terminal block 1
Startup Guide 1
Safety and Regulatory Compliance Sheet 1
3.2 Support and Resources
For additional documentation and software downloads, FAQs, troubleshooting
guides and technical support, please visit www.anybus.com/support.
Have the product article number available, to search for the specific product
page. You find the product article number on the product cover.
Anybus®Managed Industrial L3 Switch Startup Guide SP2556 1.1 en-US

Installation 6 (24)
4 Installation
4.1 DIN Rail Mounting
Mount the switch on a DIN rail in accordance with the EN 50022 standard.
Procedure
Mount the switch on a DIN rail:
1. Insert the upper end of the DIN rail clip into the DIN rail.
2. Push the bottom of the DIN rail clip into the DIN rail.
Anybus®Managed Industrial L3 Switch Startup Guide SP2556 1.1 en-US

Installation 10 (24)
4.5 Connecting Digital Output Wires
Before You Begin
The relay output is used to detect user-configured events.
When a user-configured event is triggered, the two wires attached to the DO,
fault contacts, form a close circuit.
The fault circuit remains opened until a user-configured event occur.
Procedure
Connect the Digital Output (DO):
1. Insert the wires into the 2 pin DO contact on the 8 pin terminal block.
2. Tighten the wire-clamp screws.
Anybus®Managed Industrial L3 Switch Startup Guide SP2556 1.1 en-US

Installation 12 (24)
4.7 Connecting Power Wires
Caution
Ensure that the power supply is turned off before connecting it to the
switch.
Use a power supply of 8–32 VDC to power the switch.
Max power consumption: 4.8 W.
The relay contact supports 0.5 A current, 24 VDC.
Procedure
1. Connecting to main power supply P1: Insert the positive and negative
wires into the P1+ and P1- contact on the 8 pin terminal block.
2. Connecting to redundant power supply P2: Insert the positive and
negative wires into the P2+ and P2- contact on the 8 pin terminal block.
3. Tighten the wire-clamp screws.
4. Connect the power wires to a DC switching type power supply.
Anybus®Managed Industrial L3 Switch Startup Guide SP2556 1.1 en-US

Configuration 15 (24)
5 Configuration
5.1 Before You Begin Configuration
The switch is configured through web management or console management.
The switch default IP address is http://192.168.10.1/.
The default switch login user name and password is admin.
5.2 Web Management
Prepare for configuring the switch settings via the web management interface.
Before You Begin
►Connect the switch to your computer.
►Connect the switch to power.
►To link your computer with the switch, make sure that the IP address of
the computer is located in the same subnet as the switch default IP address.
Procedure
Access the web management interface:
1. In your browser, type http://IP address and press Enter.
→ The web-based management interface login screen appears.
2. In the login screen, enter user name and password.
3. Click OK.
→ The web-based management interface welcome page appears.
To Do Next
►Configure the switch.
Follow the instructions in the user manual.
Anybus®Managed Industrial L3 Switch Startup Guide SP2556 1.1 en-US

Configuration 16 (24)
5.3 Console Management
Prepare for configuring the switch settings by console management.
Procedure
Connecting console cable:
1. Connect a console cable between your computer and the RS232 console
port.
Access the switch through console management:
2. Go to Start ►Program ►Accessories ►Communication ►Hyper Terminal.
3. Give the new console connection a name.
4. Choose COM name.
5. Select correct serial settings:
– Baud Rate: 115200
– Parity: None
– Data Bit: 8
– Stop Bit: 1
6. In the login screen, enter user name and password.
To Do Next
►Configure the switch with CLI Commands.
Follow the instructions in the user manual.
Anybus®Managed Industrial L3 Switch Startup Guide SP2556 1.1 en-US

Configuration 18 (24)
5.5 Factory Reset
Procedure
To reset the switch to its factory settings:
1. Ensure that the switch is powered on.
2. Use a pointed object (such as a ballpoint pen) to press and hold the reset
button for >10 seconds.
Result
→ Once the reset button is released, the switch reboot automatically.
→ When the switch has successfully rebooted, the SYS LED turns green.
Anybus®Managed Industrial L3 Switch Startup Guide SP2556 1.1 en-US
Table of contents
Other HMS Switch manuals
Popular Switch manuals by other brands

Cisco
Cisco Nexus 93108TC-FX3P Hardware installation guide

MFJ Enterprises
MFJ Enterprises MFJ-1272B manual

Ross
Ross Synergy MD manual

Rockwell Automation
Rockwell Automation Allen-Bradley Lifeline 4 Application Technique

GeoVision
GeoVision GV-POE1611-V2 user manual

LEGRAND
LEGRAND 3 109 77 quick start guide

Moxa Technologies
Moxa Technologies ToughNet TN-5508 Series Hardware installation guide

pro bel
pro bel 3408 Technical manual

LevelOne
LevelOne GEP-2681 Quick installation guide

LevelOne
LevelOne IFP-0504 Quick installation guide

Foundry Networks
Foundry Networks FESX Guide

IKONIX
IKONIX SCI E-Stop instruction sheet