manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. HOLOVISION
  6. •
  7. Intercom System
  8. •
  9. HOLOVISION 101-VIK User manual

HOLOVISION 101-VIK User manual

Manual Type 115
Viking W-1000, C-1000B
with Essex 265 controller
For Models
Specifications
Communication
Viking W-1000 Doorbox uses “half-duplex”
communication, allowing for high speaker and
microphone volume, witout the possibility of
feedback
Access Control
Essex “stand-alone” 5 button keypad
1 relay
5-6 users
16.5 VAC power supply included
INSTALLATION
INSTRUCTIONS
501 E. Goetz Ave.
Santa Ana, Ca 92707
www.eholovision.com
Ph. 714-434-6904
Fax 800-362-0002
HOLOVISION
NOTE: See “Doorphone Adjustments and Programming” for volume
adjustments and DIP switch settings.
101-VIK
103-VIK
107-VIK
201-VIK
203-VIK
301-VIK
302-VIK
304-E265-VIK
305-E265-VIK
400-E265-VIK
401-E265-VIK
Page 2 TYPE 115
Viking W-1000 Wiring
Wiring 2 Doorboxes into Unused CO Port on KSU
VIKING Model C-1000B
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19
EARTH GND
PHONE LINE INPUT
LINE OUT TO PHONES
KEYLESS CONTACT
DOOR BOX 1
DOOR BOX POWER
DOOR BOX 2
DOOR STRIKE 1
DOOR STRIKE 2
BATT
ON
1 2 3
C
O
M
N.
O.
N.
C.
1
KSU
13.8 VAC
1.25A
DO NOT CONNECT CO LINE IN
13.5 VAC IN
Holovision Face Plates shown
with W-1000 installed
“Talk Battery” is ON
When used w/o CO line KSU,
AUX OUTPUT N.O.
AUX OUTPUT COMMON
AUX OUTPUT N.C.
ON
OFF
TALK
OFF
NOTE: See “Doorphone Adjustments and Programming” for volume
adjustments and DIP switch settings on the doorphone.
See “C-1000B Adjustments and Programming” for settings on
the doorphone controller
TYPE 115 Page 3
Viking W-1000 Wiring
Wiring Using Standard Phones - Doorboxes Share CO Line with Phones
VIKING Model C-1000B
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19
EARTH GND
PHONE LINE INPUT
LINE OUT TO PHONES
KEYLESS CONTACT
DOOR BOX 1
DOOR BOX POWER
DOOR BOX 2
DOOR STRIKE 1
DOOR STRIKE 2
TALK
OFF
BATT
ON
1 2 3
C
O
M
N.
O.
N.
C.
1
13.8 VAC
1.25A
CO LINE IN
13.5 VAC IN
Holovision Face Plates shown
with W-1000 installed
“Talk Battery” is OFF
When used with standard phones
AUX OUTPUT N.O.
AUX OUTPUT COMMON
AUX OUTPUT N.C.
ON
OFF
TO STANDARD
PHONES
NOTE: See “Doorphone Adjustments and Programming” for volume
adjustments and DIP switch settings on the doorphone.
See “C-1000B Adjustments and Programming” for settings on
the doorphone controller
Page 4 TYPE 115
Viking W-1000 Wiring
Wiring into Unused CO Port on KSU - with Essex Gate Control System -
AC Out For Strike
VIKING Model C-1000B
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19
EARTH GND
PHONE LINE INPUT
LINE OUT TO PHONES
KEYLESS CONTACT
DOOR BOX 1
DOOR BOX POWER
DOOR BOX 2
DOOR STRIKE 1
DOOR STRIKE 2
TALK
OFF
BATT
ON
1 2 3
C
O
M
N.
O.
N.
C.
1
KSU
13.8 VAC
1.25A
13.5 VAC IN
Holovision Face Plate shown
with W-1000 installed
“Talk Battery” is ON
When used w/o CO line
ON
OFF
Essex Model 265
NC 2
NO 2
COM 2
NC 1
NO 1
COM 1
DC
OUT
AC
IN
Remote
Monitor
Earth
Remote Bypass Button
Gate Strike with MOV
MOV is recommended
Keypad Cable
16.5 VAC
40 VA
Relay Out to Essex Controller
DO NOT CONNECT CO
LINE IN
NOTE 1: Remove the jumper wire & MOVs from left side terminal strip. Wire right side terminal strip
“color for color”.
NOTE 2: MOV (metal oxide varistor) is the small red component which is included. Its purpose is to
absorb “inductive kick back” which can be created when power is removed from the strike.
TYPE 115 Page 5
Viking W-1000 Wiring
Wiring Using Standard Phones - with Essex Gate Control System -
Contact Closure for Gate Operation
VIKING Model C-1000B
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19
EARTH GND
PHONE LINE INPUT
LINE OUT TO PHONES
KEYLESS CONTACT
DOOR BOX 1
DOOR BOX POWER
DOOR BOX 2
DOOR STRIKE 1
DOOR STRIKE 2
TALK
OFF
1 2 3
C
O
M
N.
O.
N.
C.
1
13.8 VAC
1.25A
CO LINE IN
13.5 VAC IN
Holovision Face Plate shown
with W-1000 installed
“Talk Battery” is OFF
When used with standard phones,
ON
OFF
Essex Model 265
NC 2
NO 2
COM 2
NC 1
NO 1
COM 1
DC
OUT
AC
IN
Remote
Monitor
Earth
Keypad Cable
16.5 VAC
40 VA
TO STANDARD
PHONES
BAT
ON
“Open”
Terminals
on Gate
Motor
NOTE : Remove the jumper wire & MOVs from left side terminal strip. Wire right side terminal strip
“color for color”.
Doorphone Adjustments and Programming
Page 6 TYPE 115
In certain noisy locations (traffic or wind), the microphone volume may need to be decreased. A symptom
of this is one-way talk path, in which the distant party cannot be heard over the speaker. A “MIC VOL”
adjustment is provided on the doorphone for increasing or decreasing the microphone volume.
Microphone Volume
The “SPKR VOL” pot can be adjusted to increase or decrease the speaker volume to the desired level.
Speaker Volume
The “maximum number of rings can be adjusted using the DIP switches.
Maximum Number of Rings
Sw 1 Sw 2 Max Rings
OFF OFF 2
ON OFF 3
OFF ON 10
ON ON 30
1 Disconnect the PHONE LINE INPUT.
2 Slide the TALK BATTERY switch to the ON position.
3 Move DIP SWITCH 2 from OFF to ON.
4 Connect a phone to terminals 4 & 5 - LINE OUT TO PHONES.
5 Pick up the phone (you will hear a double beep - indicating that you have accessed the PROGRAMMING MODE).
6 You can now Touch Tone program the features listed below
Access Programming Mode (Local Access)
Step Action
1 Make sure C-1000B is in Programmin Mode - See above
2 Program Strike 1 activation time as follows:
3 Enter time (seconds) followed by #01
4 Program Strike 2 activation time as follows:
5 Enter time (seconds) followed by #02
EXAMPLE: 05#01 programs Strike 1 for 5 seoncds
03#02 programs Strike 2 for 3 seconds
Program Gate Strike Relays
Step Action
NOTE: Entering a time “00” sets time = 1/2 second Maximum time through programming = 9 seconds
C-1000B Door Controller Programming
TYPE 115 Page 7
1 Make sure C-1000B is in Programmin Mode - See Page 8
2 Program Aux Contact activation time as follows:
3 Enter time (seconds) follwed by #03
EXAMPLE: 01#03 programs Aux Contact for 1 seoncd.
Program Auxilliary Contacts*
Step Action
*In this mode, Auxiliary contacts can be activated (closed) whenever Doorbox 1 or Doorbox 2 is activated.
See page 2 or 6 of this document for the location of the terminals on the C-1000B
The steps above are for “timed activations” (0.5 to 10 seconds). See page 8 (Section 6) of the C-1000B manual for a
description of other Auxiliary Contact Modes.
ADDITIONAL C-1000B MODES:
Doorbell Mode- phones will not ring when doorbell is pushed. This is useful when
conventional door chimes are desired. In order to use this feature, the
Auxiliary Contacts must be programmed. (see above)
Custom Ring Mode - Distinguishes doorbox ring from CO ring when connected to KSU.
CCTV Video Control Mode - The C-1000B can switch 2 CCTV cameras, displaying the
camera at the doorbox which initiates the call. This mode
cannot be used when the “Auxiliary Contacts” are being used.
REFER TO C-1000B MANUAL FOR MORE INFORMATION ON THESE, AND OTHER MODES OF OPERATION.
Return to normal use mode
Step Action
NOTE: Entering a time “00” sets time = 1/2 second
1 Slide the TALK BATTERY switch to the OFF position.
2 Move DIP SWITCH 2 from ON to OFF.
3 Re-connect the PHONE LINE INPUT and LINE OUT TO PHONES.
Viking Operation
Page 8 TYPE 115
OPERATION
ANSWER A CALL FROM DOORBOX
When the phones ring, pick up a phone to be connected to the visitor.
When the C-1000B controller is used, you will hear a beep tone when
the phone is answered - one beep for doorbox 1, and 2 beeps for
doorbox 2.
PLACING CO LINE CALLS ON HOLD (CALL WAITING)
If a phone call is in progress, and a door box is activated, a single or
double “call waiting “ tone will be heard. To place the call in progress on
hold and speak to the visitor, push #. When you want to return to the
original phone call, push #.
ACTIVATING A DOORSTRIKE OR OPENING A GATE
To open the gate, you must first be connected to the doorbox.
Push . You will then hear a confirmation tone, and the relay will be
activated for the programmed time. If a call was already in progress,
pressing will open the gate, and return the system to the original
phone call.
LATCH / UNLATCH A GATE
To use this feature, you must first be connected to the doorbox.
Latch relay 1 or 2 1
Unlatch relay 1 or 2 0
**
**
**
TYPE 115 Page 9
Set Essex Relay Options
Step Action
GOAL: To use jumper pins on circuit board to configure standard
relay options. In this configuation, Codes 1 and 2
operate Relay 1. Codes 3, 4, 5 operate Relay 2.
1 Relay 1 and 2 activate. Only Relay 1 latch*
Code Relay 1 Relay 2
Open Latch Open Latch
Master Code No No No No
Code 1,2 Yes Yes No No
Code 3, 4, 5 No No Yes No
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
Master Unlock
1, 2 Unlock
3,4,5 Unlock
1,2 Latch
3, 4,5 Latch
CCTV
Doorbell
Relay 1
Relay 2
Step Action
2 Relay 1 and 2 activate and latch*
Code Relay 1 Relay 2
Open Latch Open Latch
Master Code No No No No
Code 1,2 Yes Yes No No
Code 3, 4, 5 No No Yes Yes
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
Master Unlock
1, 2 Unlock
3,4,5 Unlock
1,2 Latch
3, 4,5 Latch
CCTV
Doorbell
Relay 1
Relay 2
*LATCHING RELAY: In order to latch either relay, simply enter the code,
followed by “7”. Repeat (code, 7) in order to unlatch the relay.
The top example would be used where the driveway gate was connected to
Relay 1 (and could be locked open), and the pedestrian gate was connected
to Relay 2. (No latching possible).
Page 10 TYPE 115
Programming of Essex Keypad
1 Enter “Master Code”
2 Enter 113 (3 beeps).
3 Enter User Code 2.
4 Wait 5 seconds for 3 reset beeps.
Set User Code 2
Step Action
1 Press “Program” switch once. (keypad will beep 4 times)
2 Once “Program” switch is pressed, you have 2 minutes to complete Step 5.
3 Press “1119”. (you will hear 3 beeps)
4 Step 5 must be completed within 5 seconds of Step 3.
5 Enter “Master Code” *
6 Wait 5 seconds for 3 beeps to confirm new “Master Code”.
Set Master Code
Step Action
1 Enter “Master Code”
2 Enter 111 (3 beeps).
3 Enter User Code 1.
4 Wait 5 seconds for 3 reset beeps.
Set User Code 1
Step Action
GOAL: Set-up master and user codes
* MASTER CODE: The default Master Code is 13579. This should be replaced by a unique code to be used only by
your company. The Master Code can be 3 to 8 digits long.
1 Enter “Master Code”.
2 Enter 115 (3 beeps).
3 Enter User Code 3.
4 Wait 5 seconds for 3 reset beeps.
Set User Code 3
Step Action
TYPE 115 Page 11
Programming of Essex Keypad
1 Enter “Master Code”.
2 Enter 117 (3 beeps).
3 Enter User Code 4.
4 Wait 5 seconds for 3 reset beeps.
Set User Code 4
Step Action
1 Enter “Master Code”.
2 Enter 119 (3 beeps).
3 Enter User Code 5.
4 Wait 5 seconds for 3 reset beeps.
Set User Code 5
Step Action
1 Enter Master Code .
2 Enter address of code to be deleted (111, 113, etc.).
3 Do not enter any code until you hear 3 reset beeps.
4 Wait 5 seconds for 3 reset beeps.
Delete Any Code
Step Action
Note: User codes can be 3 to 8 digits
1 Enter any User Code (1 -5).
2 Enter “7”. This will cause the relay to latch (subject to the jumper pin settings - see Page 5).
3 To unlatch the relay, re-enter the user Code, followed by “7”.
Step Action
Latch a Relay
Page 12 TYPE 115
Programming of Essex Keypad
1 Press “Program” switch (keypad will beep 4 times).
2 Enter 1115 (3 beeps).
3 Enter 1 for every 1 second latch time, and 5 for every 5 seconds.
Examples:
6 seconds = 5, 1
8 seconds = 5, 1, 1, 1
12 seconds = 5, 5, 1, 1
4 Wait 5 seconds for 4 reset beeps.
Set Activation Time Of Relay 2 (User codes 3, 4& 5 - see note below)
Step Action
Note: The above 2 steps are actually setting the activation times for user code 1, 2 and user code 3, 4, 5. Using the
jumper pin setting as shown in “Set Essex Relay Options”, this will set activaiton time of Relays 1 & 2.
1 Press “Program” switch (keypad will beep 4 times).
2 Enter 1117 (3 beeps).
3 Enter 1 for every 1 second latch time, and 5 for every 5 seconds.
Examples:
6 seconds = 5, 1
8 seconds = 5, 1, 1, 1
12 seconds = 5, 5, 1, 1
4 Wait 5 seconds for 4 reset beeps.
Set Activation Time Of Relay 1 (User codes 1 & 2 - see note below)
Step Action

This manual suits for next models

10

Other HOLOVISION Intercom System manuals

HOLOVISION 400-S12-PAN2 User manual

HOLOVISION

HOLOVISION 400-S12-PAN2 User manual

HOLOVISION 400-A-VIO User manual

HOLOVISION

HOLOVISION 400-A-VIO User manual

HOLOVISION 400-S12-TES2 User manual

HOLOVISION

HOLOVISION 400-S12-TES2 User manual

HOLOVISION 400-A-VIK User manual

HOLOVISION

HOLOVISION 400-A-VIK User manual

HOLOVISION Viking E-40 User manual

HOLOVISION

HOLOVISION Viking E-40 User manual

HOLOVISION 400-A-PAN User manual

HOLOVISION

HOLOVISION 400-A-PAN User manual

HOLOVISION 400-S12-PAN User manual

HOLOVISION

HOLOVISION 400-S12-PAN User manual

HOLOVISION 100-Pan2 User manual

HOLOVISION

HOLOVISION 100-Pan2 User manual

HOLOVISION 420-VIO2 User manual

HOLOVISION

HOLOVISION 420-VIO2 User manual

HOLOVISION 400-W-VIK User manual

HOLOVISION

HOLOVISION 400-W-VIK User manual

HOLOVISION 401-W-VIO User manual

HOLOVISION

HOLOVISION 401-W-VIO User manual

HOLOVISION 401-A-PAN2 User manual

HOLOVISION

HOLOVISION 401-A-PAN2 User manual

HOLOVISION 400-A-VoIP User manual

HOLOVISION

HOLOVISION 400-A-VoIP User manual

HOLOVISION 400-S12-VIK User manual

HOLOVISION

HOLOVISION 400-S12-VIK User manual

HOLOVISION 404-W-VoIP User manual

HOLOVISION

HOLOVISION 404-W-VoIP User manual

HOLOVISION 401-W-PAN User manual

HOLOVISION

HOLOVISION 401-W-PAN User manual

HOLOVISION 400-S12-VIO2 User manual

HOLOVISION

HOLOVISION 400-S12-VIO2 User manual

HOLOVISION 400-A-TES2 User manual

HOLOVISION

HOLOVISION 400-A-TES2 User manual

HOLOVISION 400-W-TES2 User manual

HOLOVISION

HOLOVISION 400-W-TES2 User manual

HOLOVISION Viking E-10 User manual

HOLOVISION

HOLOVISION Viking E-10 User manual

Popular Intercom System manuals by other brands

CAME BPT AGATAKIT/X1-LVC installation instructions

CAME BPT

CAME BPT AGATAKIT/X1-LVC installation instructions

Aiphone MY-1CD Installation & operation manual

Aiphone

Aiphone MY-1CD Installation & operation manual

CyberData 11307 Operation guide

CyberData

CyberData 11307 Operation guide

ACT ACT1020 - WIRING FOR ENTRYEXIT manual

ACT

ACT ACT1020 - WIRING FOR ENTRYEXIT manual

Aiphone IX-DVF-6 Installation and programming guide

Aiphone

Aiphone IX-DVF-6 Installation and programming guide

Viking E-30 Technical practice

Viking

Viking E-30 Technical practice

DIGITALas DD-5000 manual

DIGITALas

DIGITALas DD-5000 manual

urmet domus 1730 Installation and instruction manual

urmet domus

urmet domus 1730 Installation and instruction manual

Aiphone C-123L/A Installation & operation manual

Aiphone

Aiphone C-123L/A Installation & operation manual

XtendLan DPM-IP700 quick start guide

XtendLan

XtendLan DPM-IP700 quick start guide

Curv HD VIDEO DOORBELL instruction manual

Curv

Curv HD VIDEO DOORBELL instruction manual

Axis A82 Series user manual

Axis

Axis A82 Series user manual

urmet domus IPERVOICE SYSTEM installation manual

urmet domus

urmet domus IPERVOICE SYSTEM installation manual

DSE DM-C2 installation manual

DSE

DSE DM-C2 installation manual

Zenitel TEIV+ Mounting and installation manual

Zenitel

Zenitel TEIV+ Mounting and installation manual

SOMFY V300 installation guide

SOMFY

SOMFY V300 installation guide

Comelit 2619 Technical manual

Comelit

Comelit 2619 Technical manual

Elvox PETRARCA 6209 Installation and operation manual

Elvox

Elvox PETRARCA 6209 Installation and operation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.