Instructions for C-2000 Controller
peration Instructions for C-2000B Controller
ANSWER A CALL FR M D RB X
When the phones ring, pick up a phone to be connected to the visitor.
PLACING C LINE CALLS N H LD (CALL WAITING)
f a phone call is in progress, and a doorbox is activated, one to four beeps will be heard (indicating which doorphone is calling).To place the call in progress on hold and
speak to the visitor, push #. When you want to return to the original phone call, push #.
ACTIVATING A D RSTRIKE R PENING A GATE
When a call is in progress, press to open the gate and return to the original call. f you do not want to open the gate, press # to return to the original call.
Strike can be activated with out the need of a “call-first” to the entry phone. Refer to the list below for codes for specific entry relays.
**
1 Move D P switch 2 from OFF to ON position.
2 Come off-hook with any house phone connected to terminals 4 & 5 LINE UT T PH NES.
3 Double beep indicates accessing the programming mode.
4 You can now program the C-2000A. The features covered in this manual are Maximum Doorphone Ring Count
and Door Strike Activation Time. For information on programming other features see the Viking C-2000 manual.
5Move D P switch 2 back to the FF position.
STEP ACTION
Access Programming Mode (Local Access)
1Follow steps 1-3 from “Access Programming Mode” (above).
2 At “double beep” enter desired number of rings, followed by #61. Example: For 7 rings, enter “07#61”.
3 Hang up the phone.
STEP ACTION
Maximum Doorphone Ring Count - Factory Default is 5 Rings
1 Follow steps 1-3 from “Access Programming Mode” (above).
2 At “double beep” enter desired number of seconds of strike activation, followed by:
#19 for Gate 1, #29 for Gate 2, #39 for Gate 3, #49 for Gate 4
Examples:
Set Gate 1 for 8 seconds (08#19); Set Gate 3 for 15 seconds (15#39)
3 Hang up the phone.
STEP ACTION
Program Gate Strike Relays - Factory Default is 0.5 Seconds
Entry Relay Strike Code
1 #1**
2 #2**
3 #3**
4 #4**
The C-2000 controller is factory set to work right out of the box. f customization of
the default settings is required, see the steps listed below. Refer to the C-2000
manual for additional options
Page 5 TYPE 6.5.0.3-RF