manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. HoMedics
  6. •
  7. Air Cleaner
  8. •
  9. HoMedics AR-29-GB User manual

HoMedics AR-29-GB User manual

Instruction Manual
AR-29-GB
AR-29-EU
Oscillating HEPA+UV-C Tower
Air Purifier
IB-AR29EU-1212-02_Layout 1 13/12/2012 10:57 Page 1
3
GB
READ ALL INSTRUCTIONS BEFORE USE.
SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.
IMPOR AN SAFEGUARDS:
HEN USING ELECTRICAL PRODUCTS, ESPECIALLY HEN CHILDREN ARE PRESENT,
BASIC SAFETY PRECAUTIONS SHOULD AL AYS BE FOLLO ED, INCLUDING THE
FOLLO ING:
• ALWAYS unplug the appliance from the electrical outlet immediately after using and before cleaning.
o disconnect, turn all controls to the‘OFF’ position, then remove plug from outlet.
• NEVER leave an appliance unattended when plugged in. Unplug from the mains outlet when not in use
and before putting on or taking off parts or attachments.
• his appliance is not intended for use by persons (including children) with reduced physical, sensory or
mental capabilities, or lack of experience and knowledge, unless they have been given supervision or
instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
• DO NO reach for an appliance that has fallen in water or other liquids. Switch off at the mains and unplug
it immediately. Keep dry – DO NO operate in wet or moist conditions.
• NEVER insert pins or other metallic fasteners into the appliance.
• Use this appliance for the intended use as described in this booklet. DO NO use attachments not
recommended by HoMedics.
• NEVER operate the appliance if it has a damaged cord or plug, if it is not working properly, if it has been
dropped or damaged, or dropped into water. Return it to the HoMedics Service Centre for examination
and repair.
• Keep cord away from heated surfaces.
• Excessive use could lead to the product’s excessive heating and shorter life. Should this occur, discontinue
use and allow the unit to cool before operating.
• NEVER drop or insert any object into any opening.
• DO NO operate where aerosol (spray) products are being used or where oxygen is being administered.
• DO NO operate under a blanket or pillow. Excessive heating can occur and cause fire, electrocution or
injury to persons.
• DO NO carry this appliance by the cord or use cord as a handle.
• DO NO use outdoors.
• DO NO crush. Avoid sharp folds.
• his product requires a 220-240 V AC power supply.
• DO NO attempt to repair the appliance. here are no user serviceable parts. For service, send to a
HoMedics Service Centre. All servicing of this appliance must be performed by authorised HoMedics
service personnel only.
• Never block the air openings of the appliance or place it on a soft surface, such as a bed or couch.
Keep air openings free of lint, hair etc.
• Do not place or store appliance where it can fall or be pulled into a bath or sink. Do not place in or drop
into water or other liquid.
• Failure to follow the above may result in the risk of fire or injury.
• Burns can result from improper use.
IB-AR29EU-1212-02_Layout 1 13/12/2012 10:57 Page 3
GB
SAFE Y CAU IONS :
PLEASE READ THIS SECTION CAREFULLY BEFORE USING THE APPLIANCE.
• Always place the air cleaner on a firm, level surface.
• Always place the air cleaner at least 150mm away from walls and 900mm from heat sources such as stoves,
radiators, or heaters.
• DO NO use while bathing or in the shower.
• Keep dry - DO NO operate in a wet or moist condition.
• his appliance is designed for personal, non-professional use only.
•Extreme caution is necessary when any air cleaner is used by or near children or invalids and whenever the
air cleaner is left operating and unattended.
•Always unplug the air cleaner when not in use.
•Do not operate the air cleaner with a damaged cord or plug, or after the air cleaner malfunctions, has been
dropped or damaged in any manner. Discard the air cleaner or return to HoMedics Consumer Relations for
examination, electrical or mechanical adjustment, or repair.
• his air cleaner is not intended for use in bathroom, laundry areas and similar moist indoor locations. Never
locate air cleaner where it may fall into a bathtub or other water container.
•Do not run cord under carpeting. Do not cover cord with throw rugs, runners or similar coverings. Do not
route cord under furniture or appliances. Arrange cord away from traffic areas where it can be tripped over.
• o disconnect the air cleaner, first turn controls to the OFF position, then remove plug from outlet.
• Do not tilt or move the air cleaner while it is in operation. Shut off and remove plug from outlet before moving.
• Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an electric
shock or fire, or damage the air cleaner.
•o prevent a possible fire, do not block air intakes or exhaust in any manner. Do not use on soft surface, like a
bed, where openings may become blocked.
•Use this air cleaner only for its intended use as described in this manual. Any other use not recommended by
the manufacturer may cause fire, electric shock, or injury to persons.
•Always plug the air cleaner directly into a wall outlet/receptacle. Never use with an extension cord.
SAVE THESE IMPORTANT INSTRUCTIONS FOR EASY REFERENCE
Technical Specifications
T his appliance is classified as suitable for use in tropical climates with an ambient
temperature up to 40°C.
Plug (MODEL AR-29-GB ONLY)
If the plug on this appliance is damaged, it can be replaced with a BS 1363 plug, fitted
with a 3ABS1362 fuse. Only use a 3 amp fuse with this appliance. Care must be taken
when changing the plug. If in doubt, contact a qualified electrician.
WEEE explanation
his marking indicates that this product should not be disposed with other household wastes
throughout the EU. o prevent possible harm to the environment or human health from uncontrolled
waste disposal, recycle it responsibly to promote the sustainable reuse of material resources. o
return your used device, please use the return and collection systems or contact the retailer where
the product was purchased. hey can take this product for environmental safe recycling.
Battery Directive
his symbol indicates that batteries must not be disposed of in the domestic waste as they contain
substances which can be damaging to the environment and health. Please dispose of batteries in
designated collection points.
Input voltage 220-240 V
Rated Frequency 50-60 Hz
Power 60 Watts
Weight 5.67kg
Noise Level <60 dB
Unit Height 71.12cm
4
IB-AR29EU-1212-02_Layout 1 13/12/2012 10:57 Page 4
GB
5
PRODUC FEA URES:
Control Panel
Control Panel
Main Unit HEPA Filters
Front Grill Plate
Fan Speed Timer
HEPA Filter Reset UV-C Bulb Reset
UV Bulb On/Off
Oscillation On/Off
Power On/Off
IB-AR29EU-1212-02_Layout 1 13/12/2012 10:57 Page 5
6
GB
OPERA ING INS RUC IONS
Turning the Unit On
ake the air cleaner out of the box and remove the clear protective plastic bag.
Place the air cleaner on a firm level surface.
Before turning the air cleaner ON, you need to confirm that the filters are firmly in place and did not become
loose during shipping.
NOTE: Unit will not operate unless filters and grill are properly installed.
1. On/Off and Speed Settings
o turn the air cleaner on, press the ON/OFF button on the control panel. When the air cleaner is on, the
LED light in the ON/OFF button on the control panel will be lit and the air cleaner will start to operate on LOW
speed.
Once the air cleaner is ON, press the + button to increase the fan speed to the MED. settings. Press the +
again to increase the fan speed to HIGH setting. o decrease the fan speed, press the – button until your
desired setting is reached. he fan speed setting is indicated by LED ring around the fan icon.
o turn the air cleaner OFF, simply press the ON/OFF button on the control panel.
2. Timer
here are four possible timer settings: 2 (two) hours, 4 (four) hours, 8 (eight) hours, and 12 (twelve) hours.
o activate the timer press the + button on the control panel under the IMER LED screen. Each time the +
button is pressed, it will display the successive settings. o return to a setting already passed, press the –
button. Once a timer setting has been selected, it will remain displayed on the LED screen.
3. Oscillation
o activate the oscillation, press the button. o stop oscillation, press the button a second time.
4. UV-C Bulb
o activate the UV-C bulb, press the UV-C button on the control panel. o turn the UV bulb off, press the
button a second time.
Fig.1 Fig.2
Fig.3 Fig.4
1. o check filter, open the rear grill
by gently pushing down on the
release tab on the top of the rear
grill (Fig 1).
2. Open the plate outward until the
tabs at the bottom of the grill plate
easily slide away from the unit
(Fig 2).
3. he HEPA filters will be resting
inside the unit. Make sure that the
filters are firmly seated inside of the
unit (Fig 3).
4. Place the tabs at the bottom of the
grill plate into the base of the unit.
Gently push the grill plate back into
place until you hear a click sound
indicating that the grill is firmly
latched.
Connect the power cord into a
standard AC outlet (Fig 4).
IB-AR29EU-1212-02_Layout 1 13/12/2012 10:57 Page 6
7
GB
USING HE REMO E CON ROL
Battery Installation
One CR2025 3V battery is included with the remote control. o change the battery, remove the battery door
at the back of the remote by squeezing the tab and pulling the door away from the back of the remote.
Please insert the battery into the remote with the positive side up as shown on the drawer.
NOTE: Always keep the battery and remote control out of the reach of children.
Battery note
• If the unit is not going to be used for a long period of time, remove batteries to prevent damage due to
possible battery leakage.
• Clean the battery contacts and also those of the device prior to battery installation.
• Remove used batteries promptly.
• Dispose of properly in accordance with all state, province, and country regulations.
• Do not dispose of batteries in fire. Batteries may explode or leak.
Bottom of Remote
Power ON/OFF
Speed Settings
Timer Settings
Oscillation ON/OFF
UV Bulb ON/OFF
IB-AR29EU-1212-02_Layout 1 13/12/2012 10:57 Page 7
8
GB
CLEANING AND MAIN ENANCE
We recommend that the air cleaner be cleaned at least once a month and before storage.
urn the air cleaner OFF at the main switch and unplug it from the outlet before any cleaning or maintenance
procedure.
Use a dry cloth to clean the external surfaces of the air cleaner.
he grill plate may be cleaned with a damp cloth or the brush attachment of your vacuum cleaner.
DO NOT USE WATER, WAX, POLISH OR ANY CHEMICAL SOLUTION.
Replace UV-C Bulb Indicator
he UV-C Bulb is equipped with a REPLACE UV-C BULB indicator to let the user know it is time to replace the
bulb. When the bulb needs to be changed, the REPLACE UV-C BULB indicator will light up on the control
panel. Once the UV-C bulb has been replaced, press and hold the REPLACE UV-C BULB button to reset the
indicator until it beeps.
Replacing UV-C Bulb
Warning: take care as bulb may be hot.
1. Open and remove the rear grill
2. Remove the upper HEPA filter
3. Use screwdriver to remove two screws and detach the metal UV bulb cover
4. Grasp the UV bulb and pull it from the bulb socket
5. Replace with new UV-C bulb and push it into the bulb socket
6. Replace the metal UV bulb cover
7. Replace the rear grill
NOTE: UV-C bulb contains Mercury (Hg). Dispose of at your local authority recycling station. Do not dispose
of with general waste.
Clean Filter Indicator
he air cleaner is equipped with a CLEAN FIL ER indicator to let the user know when it is time to clean the
HEPA filter, about every 480 hours of use. When the HEPA filter is ready to be cleaned, the LED CLEAN FIL ER
indicator will light up on the control panel.
If the air cleaner is used daily, we recommend cleaning the HEPA filters more frequently.
Once the HEPA filter has been cleaned, press and hold the CLEAN FIL ER button to reset the Indicator until it
beeps.
Cleaning the HEPA Filter
Make sure that the air cleaner is turned OFF and unplugged from the outlet before cleaning.
1. Open the rear grill by gently pushing down on the tab on the top of the grill plate (Fig 5).
2. Open the plate outward until the tabs at the bottom of the grill plate easily slide away from the unit (Fig 6).
3. Remove the HEPA filters from the main unit (Fig 7).
NOTE: here are two HEPA filters in this air cleaner.
4. Use the brush attachment with your vacuum cleaner. Run the attachment along both sides of the HEPA
filters, cleaning thoroughly between the accordion folds of the filters (Fig 8).
5. Place the clean HEPA filters back in the main unit, making sure that it is firmly seated inside the unit (Fig 9).
6. Place the tabs at the bottom of the grill plate into the base of the unit. Gently push the grill plate back into
place until you hear a click sound indicating that the grill is firmly latched (Fig 10).
DO NOT USE WATER OR ANY HOUSEHOLD CLEANERS OR DETERGENTS TO CLEAN THE HEPA FILTER.
It is recommended that you replace the HEPA filter every 18 months to maintain the optimal
performance of your air cleaner. To purchase the HEPA replacement filter, go back to your retailer
(where you purchased your air cleaner) or visit www.homedics.com
IB-AR29EU-1212-02_Layout 1 13/12/2012 10:57 Page 8
9
GB
ROUBLESHOO ING
PROBLEM POSSIBLE CAUSE SOLUTION
Unit will not operate • Unit is not plugged in
• No power at unit
• Plug unit in
• Press the POWER button to turn
the power on
• Check circuits, fuses, try a
different outlet
Reduced airflow or poor filtering • he front grill may be blocked
• HEPA filter may be clogged
• Check to make sure nothing is
blocking the front grill and air
outlet
• Check and clean filter
• Replace the filter
Excessive Noise • he unit is not level • Place the unit on a flat, even
surface
Fig.5 Fig.6
Fig.8 Fig.9
Fig.7
Fig.10
IB-AR29EU-1212-02_Layout 1 13/12/2012 10:58 Page 9
IB-AR-29-1212-02
IB-AR29EU-1212-02_Layout 1 13/12/2012 10:58 Page 108

This manual suits for next models

1

Other HoMedics Air Cleaner manuals

HoMedics Professional HEPA User manual

HoMedics

HoMedics Professional HEPA User manual

HoMedics AR-NC01GY Instruction Manual

HoMedics

HoMedics AR-NC01GY Instruction Manual

HoMedics Ozone Clean Instruction Manual

HoMedics

HoMedics Ozone Clean Instruction Manual

HoMedics AR-45 Guide

HoMedics

HoMedics AR-45 Guide

HoMedics Pet Plus ATPET02AU Instruction Manual

HoMedics

HoMedics Pet Plus ATPET02AU Instruction Manual

HoMedics Brethe User manual

HoMedics

HoMedics Brethe User manual

HoMedics TotalClean User manual

HoMedics

HoMedics TotalClean User manual

HoMedics True HEPA AF-20 Instruction Manual

HoMedics

HoMedics True HEPA AF-20 Instruction Manual

HoMedics TOTALCLEAN AP-T40-EU User manual

HoMedics

HoMedics TOTALCLEAN AP-T40-EU User manual

HoMedics TotalClean User manual

HoMedics

HoMedics TotalClean User manual

HoMedics TOTALCLEAN PETPLUS 5IN1 User manual

HoMedics

HoMedics TOTALCLEAN PETPLUS 5IN1 User manual

HoMedics AR-15 Guide

HoMedics

HoMedics AR-15 Guide

HoMedics AR-29A-GB User manual

HoMedics

HoMedics AR-29A-GB User manual

HoMedics TOTALCLEAN QS-APT20 User manual

HoMedics

HoMedics TOTALCLEAN QS-APT20 User manual

HoMedics AR-29A-GB User manual

HoMedics

HoMedics AR-29A-GB User manual

HoMedics AP-25A User manual

HoMedics

HoMedics AP-25A User manual

HoMedics AF-75 Instruction Manual

HoMedics

HoMedics AF-75 Instruction Manual

HoMedics AR-10A-GB User manual

HoMedics

HoMedics AR-10A-GB User manual

HoMedics AP-15A-GB User manual

HoMedics

HoMedics AP-15A-GB User manual

HoMedics TotalClean AP-DT10 User manual

HoMedics

HoMedics TotalClean AP-DT10 User manual

HoMedics TOTALCLEAN AP-T45WT-EU User manual

HoMedics

HoMedics TOTALCLEAN AP-T45WT-EU User manual

HoMedics AR-20 User manual

HoMedics

HoMedics AR-20 User manual

HoMedics TOTALCLEAN AP-15 User manual

HoMedics

HoMedics TOTALCLEAN AP-15 User manual

HoMedics AT-45 Instruction Manual

HoMedics

HoMedics AT-45 Instruction Manual

Popular Air Cleaner manuals by other brands

Envion ionic pro turbo TA500 owner's manual

Envion

Envion ionic pro turbo TA500 owner's manual

Panasonic F-PXM55H operating instructions

Panasonic

Panasonic F-PXM55H operating instructions

Ozone Solutions HG-1500 manual

Ozone Solutions

Ozone Solutions HG-1500 manual

Sharp KC-850EK Operation manual

Sharp

Sharp KC-850EK Operation manual

BROAD Clean Air AIRPRO CO2 SENSOR quick start guide

BROAD Clean Air

BROAD Clean Air AIRPRO CO2 SENSOR quick start guide

Tiger AKH-A operating instructions

Tiger

Tiger AKH-A operating instructions

Sharp FP-FM40A Operation manual

Sharp

Sharp FP-FM40A Operation manual

Oreck XJ-201 user guide

Oreck

Oreck XJ-201 user guide

Philips AC2887 user manual

Philips

Philips AC2887 user manual

Eberg ENZA user manual

Eberg

Eberg ENZA user manual

Sharp FP-GM50E Operation manual

Sharp

Sharp FP-GM50E Operation manual

Soto SOTO-G5 Operation manual

Soto

Soto SOTO-G5 Operation manual

Daikin MCK75JVM-K Operation manual

Daikin

Daikin MCK75JVM-K Operation manual

Helios AirPal Go 300 H Installation and operating instructions

Helios

Helios AirPal Go 300 H Installation and operating instructions

Philips AC3252 user manual

Philips

Philips AC3252 user manual

Guzzanti GZ-999 instruction manual

Guzzanti

Guzzanti GZ-999 instruction manual

GBlife PM1232 instruction manual

GBlife

GBlife PM1232 instruction manual

Levoit Classic 300S user manual

Levoit

Levoit Classic 300S user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.