MI Wireless Voltage Measurements Table
Site Name /Location:bergy station
Observed Symptoms: not connect
Notes: A - Read Step-17 before you beginDate:
7 15 2013
B - Steps 12,13 & 17 require a Yes or No answerInstrument Serial Number: 11039722
C-Obtain an item file after completing the table and provide
w
the table (Do not skip this step)
D-(L)
=
Left-side I(R)
=
Right-side
E-Use a DVM to measure the DC voltages at the following locations inside the MIWireless unit
glm 7/15/13
Step Location Condition DVM Probes DVM Reading
Black Red
1Battery 7 or 18 Amp/Hr)
w
Battery Connector unplugged Battery (-) Battery (+) 13.51
2
w
Battery Connector plugged-inBattery (-)Battery (+) 13.61
3SunSaver Charge Regulator Solar input terminal-3 terminal-413.7
4Battery inputterminal-1 terminal-2 13.68
5Load output terminal-5terminal-6 13.66
--
6TB2 Terminal Strip
w
factorywiringterminal-7 (L) terminal-8 (L) 13.57
-
7
w
oreen wire disconnected@ TB2-8 ( R ) terminal-7 (L) terminal-8 (L) 17.31
8
w
factory wirinoterminal-1 (L) terminal-2 (L) 13.48
:-
9
w
factory wirino terminal-1 (L) terminal-3 (L) 13.49
10 TB1 Terminal Strip
w
factory wiring terminal-1 (L) terminal-4 (L) 13.49
-
11
w
factory wirino terminal-1(L)terminal-3 (L) 13.48
•• I
12 Was red LED on MPC Board flashing when taking DVM reading in step 11? yes
13 power on network flashinQ Were modem LEDs on when takino DVM readino in step 11? only 20ut of 4
14
w
factory wiring terminal-7 (L) terminal-8 (L) 13.49
15
w
factory wirinQ terminal-7 (L) terminal-6 (L) 6.277
16
w
factory wirino terminal-7 (L) terminal-5 (L) 6.346
17 LCD Display Board Was the LCD blank during steps 1-16? no
LED
activity types: SunSaverLED Activity: LED Status:
Off
Model 6 Charging LoadDisconnected
'-
Green lite on
,
Offw/ HB
•
•
'-
Red not lite
On Solid
,
On w/ HB
.•.
Red/Green
,
FastFlash
Model6L
•
•
0
•
.•.
Green
MedFlash
,
'-
SlowFlash
Charging StatusBattery Status
,
Yellow
Seqncing HB
=
Heart Beat,Fast Flash
=
2Flash/See,Med Flash
=
1 Flash/Sec,Slow Flash
=
1 Flash/25ee )
'-
Red
.,