DESCRIPTION
TheSystemSensor1151lowprofileionizationtypesmoke
detectors are specifically designed to meet the performance
requirements of fire detection/alarm systems. The 1151 ion-
ization detector uses a state-of-the-art, dual unipolar sensing
chamber. The detector is designed to provide open area de-
tection and, when installed in a two-wire base, is compatible
with FCI fire alarm control panels. The detector’s operation
and sensitivity can be tested in place.
The 1151 detector is of plug-in construction and plugs into
the same base as the System Sensor 2151photoelectronic
smoke detector, making both models interchangeable. Bases
areavailablefortwo-wire,four-wire,120VACfour-wireop-
eration and also with an audible sounder.
Two visible LEDs on each detector flash every ten seconds
indicating that power is being applied to the detector. The
LEDs light steadily when the detector is in alarm. A remote
LED annunciator is available as an optional accessory.
The 1151 detector is Listed for use inside ducts up to a ve-
locity of 500 FPM.
Functional testing is performed by placing a test magnet
against the cover. The LED on the detector should light
within 30 seconds.
Field metering of detector sensitivity may be performed
with the aid of a voltmeter and Test Kit, MOD 400R.
APPROVALS
SPECIFICATIONS
Sensitivity 1.9 %/ft. (nominal)
Operating voltage 15 - 32 VDC peak
Standby current 200 uA max. avg.
Operating temperature 32 to 120oF(0to49
oC)
Relative humidity 10 to 93 % (non-condensing)
Air velocity 500 feet per minute maximum
Construction Off-white flame retardant plastic
Diameter 4 inches (10.2 cm)
Height 1.7 inches (4.2 cm)
Weight 3.6 oz. (104 g)
1151
SYSTEM SENSOR
LOW PROFILE, IONIZATION
PLUG-IN SMOKE DETECTOR
9020-0582/Ver. 1.1
16 Southwest Park, Westwood, MA 02090 USA TEL: (781) 471-3000 FAX: (781) 471-3099
Specifications are provided for information only, are not intended to be used for installation purposes, and are believed to be accurate. However, no responsibility is assumed by Fire Control
Instruments, Inc. for their use. Specifications subject to change without notice. ©2003 All Rights Reserved
FEATURES
·Unique Dual Unipolar Sensor
Provides Exceptional Stability
·Low Profile Construction
·Easy plug-in of the Head to Base
·Tamper-resistant Feature
·Test Switch
·360oView Angle Of Alarm LEDs
·Compatible with FCI Control Panels
·Audible Sounder Base (Optional)
·Field Metering of Detector Sensitivity
·Removable Insect Screen and Cover
for Field Cleaning
·Insect-resistant Screening
(.020"/.508 mm openings)
An ISO 9001 Certified Company
MOUNTING
·On a 4-inch square box with or without plaster
ring. Minimum depth 1.5 inches.
·On a 3.5-inch octagonal box. Minimum depth
1.5 inches.
INSTALLATION
Place the detector into the detector base. Turn the de-
tector clockwise until the detector locks into place.
To use the tamper-proof feature, break the smaller tab
on the scribed line in the tamper proof tab located on the
detector mounting bracket. Install the detector. To re-
move the detector from the base when using the tam-
per-proof feature, insert the blade of a small
screwdriver into the hole on the side of the base and
push the plastic lever away from the detector head. This
will allow the detector to be rotated counterclockwise
for removal. NOTE: The decorative ring must be re-
moved in order to remove the head when using the tam-
per-proof feature.
The tamper-proof feature may be defeated perma-
nently by breaking the plastic lever off the base.
NOTE: The number of two-wire smoke detectors
which can be accommodated per zone varies with dif-
ferent control panels. Consult the control panel in-
struction manual to determine the capacity.
RefertoNFPA72,Chapter5-3, “SmokeSensingFire
Detectors” for spacing, location of detectors and other
guidelines.
TESTING
Detectors may be tested in the following ways:
·Place a test magnet against the detector
as directed in the installation instructions.
The detector should go into alarm within
30 seconds.
·Field metering of detector sensitivity may be
performed with the aid of a voltmeter and Test
Kit, MOD 400R. For the complete procedure,
refer to the Installation and Maintenance
Instructions furnished with each detector.
MAINTENANCE
Cleaning programs should be adapted to the individ-
ual environment. We recommend at least an annual
cleaning of the unit. The detector screen and cover as-
sembly can be removed, revealing the sensing cham-
ber. Avacuum cleaner can be used to remove dust from
the screen, cover and sensing chamber. For the com-
plete procedure, refer to the Installation and Mainte-
nance Instructions furnished with each detector.
2of2 9020-0582
ORDERING AND TECHNICAL INFORMATION
Model Contacts Description
1151 Ionization Detector
B110LP Base, Two-wire
B112LP Form A & C Base, four-wire, 24 VDC operation
B114LP Form A, C & Supv. Base, four-wire, 120 VAC operation
B401BH Base, four-wire, with audible sounder
RA-400Z Remote Alarm Indicator
PAM-1 Form B End of Line Relay, 24 VDC
MOD 400R Test Kit

Other Honeywell Smoke Alarm manuals

Honeywell ALL-SPEC User manual

Honeywell

Honeywell ALL-SPEC User manual

Honeywell MS-5UD Series User manual

Honeywell

Honeywell MS-5UD Series User manual

Honeywell FCI 2451 Series User manual

Honeywell

Honeywell FCI 2451 Series User manual

Honeywell Notifier NBG-12LX User manual

Honeywell

Honeywell Notifier NBG-12LX User manual

Honeywell DFS8M User manual

Honeywell

Honeywell DFS8M User manual

Honeywell Silent Knight SK-Duct User manual

Honeywell

Honeywell Silent Knight SK-Duct User manual

Honeywell MORLEY-IAS MI-LPB2-S2I User manual

Honeywell

Honeywell MORLEY-IAS MI-LPB2-S2I User manual

Honeywell V-PLEX 5192SD User manual

Honeywell

Honeywell V-PLEX 5192SD User manual

Honeywell SiXSMOKE-CN User manual

Honeywell

Honeywell SiXSMOKE-CN User manual

Honeywell NOTIFIER FSP-951T-SELFT User manual

Honeywell

Honeywell NOTIFIER FSP-951T-SELFT User manual

Honeywell DFS8MS User manual

Honeywell

Honeywell DFS8MS User manual

Honeywell Photoelectronic Smoke/Temperature Detector... Assembly instructions

Honeywell

Honeywell Photoelectronic Smoke/Temperature Detector... Assembly instructions

Honeywell Notifier FDU-80 User manual

Honeywell

Honeywell Notifier FDU-80 User manual

Honeywell Notifier FSP-851 User manual

Honeywell

Honeywell Notifier FSP-851 User manual

Honeywell Fire-Lite Alarms Innovair flex D365PL User manual

Honeywell

Honeywell Fire-Lite Alarms Innovair flex D365PL User manual

Honeywell DFS8MS User manual

Honeywell

Honeywell DFS8MS User manual

Honeywell DFS8MS User manual

Honeywell

Honeywell DFS8MS User manual

Honeywell NOTIFIER NFXI-ASD11 Quick start guide

Honeywell

Honeywell NOTIFIER NFXI-ASD11 Quick start guide

Honeywell Xtralis FAAST FLEX FLX-010 User manual

Honeywell

Honeywell Xtralis FAAST FLEX FLX-010 User manual

Honeywell SS4-A HART User manual

Honeywell

Honeywell SS4-A HART User manual

Honeywell Notifier VESDA-E VEA Series User manual

Honeywell

Honeywell Notifier VESDA-E VEA Series User manual

Honeywell SS4-A2 User manual

Honeywell

Honeywell SS4-A2 User manual

Honeywell Fire-Lite Alarms SD365 User manual

Honeywell

Honeywell Fire-Lite Alarms SD365 User manual

Honeywell FMST FXV(E) Series User manual

Honeywell

Honeywell FMST FXV(E) Series User manual

Popular Smoke Alarm manuals by other brands

GE ESL 570N installation instructions

GE

GE ESL 570N installation instructions

FireAngel Thermoptek ST-622 user manual

FireAngel

FireAngel Thermoptek ST-622 user manual

Deltronic Security Numens 205 Series user manual

Deltronic Security

Deltronic Security Numens 205 Series user manual

System Sensor PERTRONIC Innovair flex D4120 Installation and maintenance instructions

System Sensor

System Sensor PERTRONIC Innovair flex D4120 Installation and maintenance instructions

ELRO FZ5002R instruction manual

ELRO

ELRO FZ5002R instruction manual

Det-Tronics X3300 instructions

Det-Tronics

Det-Tronics X3300 instructions

Xtralis VESDA-E VES-A10-P installation instructions

Xtralis

Xtralis VESDA-E VES-A10-P installation instructions

System Sensor Innovair DH100ACDCLPX Installation and maintenance instructions

System Sensor

System Sensor Innovair DH100ACDCLPX Installation and maintenance instructions

PSA Products LIF5000 LIFESAVER Installation and user manual

PSA Products

PSA Products LIF5000 LIFESAVER Installation and user manual

ELRO FS1805M manual

ELRO

ELRO FS1805M manual

Bellman & Symfon VISIT BE1551 user manual

Bellman & Symfon

Bellman & Symfon VISIT BE1551 user manual

Firehawk FHB10W manual

Firehawk

Firehawk FHB10W manual

Universal Security Instruments Sensing Plus AMI3051S instructions

Universal Security Instruments

Universal Security Instruments Sensing Plus AMI3051S instructions

Hochiki FireNET 4127 operating instructions

Hochiki

Hochiki FireNET 4127 operating instructions

Alecto SA-110 manual

Alecto

Alecto SA-110 manual

Tyco MR601TEx Product information

Tyco

Tyco MR601TEx Product information

VESDA VEP-A10-P Product guide

VESDA

VESDA VEP-A10-P Product guide

Tobi ZSSD9 Operating and installation instructions

Tobi

Tobi ZSSD9 Operating and installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.