Region: Global AP040390 REV1.3 © 2022 Hoymiles Power Electronics Inc. 01
2. Installation Steps
1. Accessories
Step 1. Plan and install the Microinverter
All accessories above are not included in the package and should be purchased separately.
The order of Step 1 and Step 2 can be reversed according to your planned needs.
- Use the AC Trunk Connector Unlock Tool to
unlock the connector upper cover.
1 ) Disassemble the AC Trunk Connector and remove the cable.
2 ) Install the AC Trunk End Cap at one side of AC Trunk Cable (The end of AC Trunk Cable)
- Loosen the three screws with screwdriver.
Untighten the cap and remove the cable.
*Note:
HMS-2000-4T Series Quick Installation Guide
FA B C E GD
A ) Mark the position of each microinverter on the rail, according to the PV module layout.
Step 2. Plan and build the AC Bus Cable
AC Trunk Cable is used to connect the microinverter to distribution box.
A ) Select the appropriate AC Trunk Cable according to the spacing between microinverters. The connector spacing of
the AC Trunk Cable should be close to spacing between microinverters to ensure that they are well-matched. (Hoymiles
provides AC Trunk Cable with different AC Trunk Connector spacing.)
B ) Determine how many microinverters you plan to install on each AC branch and prepare AC Trunk Connectors
accordingly.
C ) Take out segments of AC Trunk Cable as you need to make AC branch.
B ) Fix the screw on the rail.
C ) Hang the microinverter on the
screws, and tighten the screws. The silver
cover side of the microinverter should be
facing the panel.
- Insert the AC Trunk End cap and screw the
cap back to port, then tighten the cap.
- Plug the upper cover back to the Trunk
connector.
4.0±0.5N·m
Mounting Torque : 9 N·m
click
Item Description
A AC Trunk Cable, 12/10 AWG Cable
B M8 x 25 screws (Prepared by the installer)
C
AC Trunk Connector
D
AC Trunk Port Cap
E
AC Trunk Port Disconnect Tool
F
AC Trunk End Cap
G
H AC Trunk Connector Unlock Tool
Grounding Electrode
H
3. Leave at least 2 cm of space around the microinverter enclosure to ensure ventilation and heat dissipation.
4. Mounting torque of the 8 mm screws should be 9 N·m.Please do not over-torque.
5. Do not pull or hold the AC cable with your hand. Hold the handle instead.
Note:
1. There is an earth wire inside the wire cable and the grounding can be done directly by this wire.
If external grounding is needed, the grounding electrode, as shown on the right, can be used to bond the
mounting bracket to the racking. Torque each grounding cleat screw to 2 N•m.
2. Install the microinverter and all DC connections under the PV module to avoid direct sunlight, rain
exposure, snow buildup, UV, etc.
*Applicable to HMS-1600/1800/2000/1600B/1800B/2000B-4T microinverters
Step 5. Connect PV Modules
Step 6. Energize the System
A ) Mount the PV modules above the
microinverter.
B ) Connect the PV modules’ DC cables to the
DC input side of the microinverter.
Note:
1. Tightening torque of the cap: 4.0±0.5 N·m. Please do not over-torque.
2. Torque of locking screw: 0.4±0.1 N·m.
3. Do not damage the sealing ring in the AC Trunk Connector during disassembly and assembly.
Step 4. Create an Installation Map
A ) Peel the removable serial number label from
each microinverter.
B ) Affix the serial number label to the respective
location on the installation map (please refer
to the User Manual).
3 ) Install AC end cable on the other side of AC Trunk Cable (connected to the distribution box)
Note:
1. Make sure that the AC Trunk Connectors are kept away from any water-channeling surface.
2. In case you need to remove the inverter AC cable from AC Trunk Connector, please use the
AC Trunk Port Disconnect Tool and insert the tool into the side of AC Sub Connector to
complete the removal.
Product information is subject to change without notice. (Please download reference manuals at www.hoymiles.com).
138264700571
138264700571
D ) Repeat the above steps, lay out the cable on the rail as appropriate so that the microinverters can be connected to
the Trunk connectors.
Step 3. Complete the AC Connection
- Unlock the port upper cover, loosen the screws
with screwdriver and remove the extra cable.
(Skip this step if there is no cable at this side.)
- Prepare a segment of AC cable with suitable
length to connect to the distribution box, with
stripping requirements fulfilled.
- Insert the cable into the cap in a way that the
L, N and PE lines are in corresponding slots.
- Tighten the screws and tighten the cap back
to the port.
- Plug the upper cover back to the Trunk
connector.
Region: Global AP040390 REV1.3 © 2022 Hoymiles Power Electronics Inc. 02
B ) Connect the AC end cable to the distribution box, and wire it to the local grid network.
A) Turn on the AC breaker for the branch circuit.
B) Turn on the main AC breaker for the house. Your system
will start to generate power in about two minutes.
Step 7. Set up Monitoring System
Please refer to the DTU User Manual or DTU Quick Installation
Guide, and Quick Installation Guide for S-Miles Cloud to install
the DTU and set up monitoring system.
E ) Attach the AC Trunk Cable to the mounting
rail and fix the cable with tie wraps.
A ) Push the AC Sub Connector from microin-
verter to the AC Trunk Connector until it clicks.
C ) Please plug the AC Trunk Port Cap in any
vacant AC Trunk Port to make it water and
dust-proof.
L
PE
4.0±0.5N·m
0.4±0.1N·m
N
click
click
click
8±1mm
40±5mm
Tosheet ______
Tosheet ______
Tosheet ______
Tosheet ______
Sheet_____of_____
Hoymiles Microinverter Installation Map
PleaseMake N for North
1
A
B
C
D
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
COLUMN
ROW
AP040228 V1.3
CustomerInformation: DTUSerial Number
Azimuth:
Tilt:
Paneltype:

Other manuals for HMS-1600-4T

2

This manual suits for next models

6

Other Hoymiles Inverter manuals

Hoymiles MI-250 User manual

Hoymiles

Hoymiles MI-250 User manual

Hoymiles HMT-1600-4T User manual

Hoymiles

Hoymiles HMT-1600-4T User manual

Hoymiles HA S-3.0LV-EUG1 User manual

Hoymiles

Hoymiles HA S-3.0LV-EUG1 User manual

Hoymiles HMS-900-2T User manual

Hoymiles

Hoymiles HMS-900-2T User manual

Hoymiles HM-1200 User manual

Hoymiles

Hoymiles HM-1200 User manual

Hoymiles HMS-900-2T User manual

Hoymiles

Hoymiles HMS-900-2T User manual

Hoymiles MI-300N User manual

Hoymiles

Hoymiles MI-300N User manual

Hoymiles HM-600 User manual

Hoymiles

Hoymiles HM-600 User manual

Hoymiles HMS-2000D-4T User manual

Hoymiles

Hoymiles HMS-2000D-4T User manual

Hoymiles MI-600N User manual

Hoymiles

Hoymiles MI-600N User manual

Hoymiles HM-2000T-S Series User manual

Hoymiles

Hoymiles HM-2000T-S Series User manual

Hoymiles HM-800 User manual

Hoymiles

Hoymiles HM-800 User manual

Hoymiles HMS-1400C-4T User manual

Hoymiles

Hoymiles HMS-1400C-4T User manual

Hoymiles HM-1000 User manual

Hoymiles

Hoymiles HM-1000 User manual

Hoymiles HYS-3.0LV-EUG1 User manual

Hoymiles

Hoymiles HYS-3.0LV-EUG1 User manual

Hoymiles HYS-3.6LV-EUG1 User manual

Hoymiles

Hoymiles HYS-3.6LV-EUG1 User manual

Hoymiles HYS-3.0LV-EUG1 User manual

Hoymiles

Hoymiles HYS-3.0LV-EUG1 User manual

Hoymiles HYS-7.6LV-USG1 User manual

Hoymiles

Hoymiles HYS-7.6LV-USG1 User manual

Hoymiles MI-1000T User manual

Hoymiles

Hoymiles MI-1000T User manual

Hoymiles MI-1000 User manual

Hoymiles

Hoymiles MI-1000 User manual

Hoymiles HM-600T User manual

Hoymiles

Hoymiles HM-600T User manual

Hoymiles MI-300T User manual

Hoymiles

Hoymiles MI-300T User manual

Hoymiles HM-300 User manual

Hoymiles

Hoymiles HM-300 User manual

Hoymiles HYT-5.0HV-EUG1 User manual

Hoymiles

Hoymiles HYT-5.0HV-EUG1 User manual

Popular Inverter manuals by other brands

Hosola Bright series Operation guide

Hosola

Hosola Bright series Operation guide

LSIS iS7 PROFInet quick start guide

LSIS

LSIS iS7 PROFInet quick start guide

EUROM B950I user manual

EUROM

EUROM B950I user manual

International Ozone Titan 2000 Operation manual

International Ozone

International Ozone Titan 2000 Operation manual

Tronic TSW 300 A1 operating instructions

Tronic

Tronic TSW 300 A1 operating instructions

Wagan SmartAC 425W user manual

Wagan

Wagan SmartAC 425W user manual

Lenze i700 Series Reference manual

Lenze

Lenze i700 Series Reference manual

SEW-Eurodrive MOVIDRIVE DFC11A manual

SEW-Eurodrive

SEW-Eurodrive MOVIDRIVE DFC11A manual

DUROMAX Duro Star DS4400E user manual

DUROMAX

DUROMAX Duro Star DS4400E user manual

Sungrow SH4K6 Quick user manual

Sungrow

Sungrow SH4K6 Quick user manual

TRU Components 2315349 operating instructions

TRU Components

TRU Components 2315349 operating instructions

Riello Design white Series Instructions for the installer and the technical service centre

Riello

Riello Design white Series Instructions for the installer and the technical service centre

Afore HNS1509TL installation manual

Afore

Afore HNS1509TL installation manual

Charging Systems PSICH-1-1.5KA operating manual

Charging Systems

Charging Systems PSICH-1-1.5KA operating manual

SunSynk SUNSYNK-3.6K-SG01/03LP1 Installer manual

SunSynk

SunSynk SUNSYNK-3.6K-SG01/03LP1 Installer manual

B PLUS TV ELZapp user guide

B PLUS TV

B PLUS TV ELZapp user guide

Deye SUN-30K-G04 user manual

Deye

Deye SUN-30K-G04 user manual

Winco DR2014 Installation and operator's manual

Winco

Winco DR2014 Installation and operator's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.