HP E1313A User manual

-~
ARTISAN
®
~I
TECHNOLOGY
GROUP
Your definitive source
for
quality
pre-owned
equipment.
Artisan Technology
Group
Full-service,
independent
repair
center
with
experienced
engineers
and
technicians
on staff.
We
buy
your
excess,
underutilized,
and
idle
equipment
along
with
credit
for
buybacks
and
trade-ins
.
Custom
engineering
so
your
equipment
works
exactly as
you
specify.
•
Critical
and
expedited
services
•
Leasing
/
Rentals/
Demos
• In
stock/
Ready-to-ship
•
!TAR-certified
secure
asset
solutions
Expert
team
ITrust
guarantee
I
100%
satisfaction
All
tr
ademarks,
br
a
nd
names, a
nd
br
a
nd
s a
pp
earing here
in
are
th
e property of
th
e
ir
r
es
pecti
ve
ow
ner
s.
Find the Keysight / Agilent E1413C at our website: Click HERE

Contents
HP E1313A/E1413C High Speed A/D Module
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
WARNINGS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Safety Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Declaration of Conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Declaration of Conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Reader Comment Sheet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Chapter 1. Getting Started . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
About This Chapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Configuring the HP Scanning A/D Converter Module . . . . . . . . . . . . . . . . . . 15
Setting the Logical Address Switch . . . . . . . . . . . . . . . . . . . . . . . . . 16
Installing HP E1313 Signal Conditioning Plug-ons . . . . . . . . . . . . . . . . . 18
Installing HP E1413 Signal Conditioning Plug-ons . . . . . . . . . . . . . . . . . 22
Disabling the Input Protect Feature (optional) . . . . . . . . . . . . . . . . . . . . 26
Disabling Flash Memory Access (optional) . . . . . . . . . . . . . . . . . . . . . 26
Instrument Drivers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
About Example Programs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Verifying a Successful Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Chapter 2. Field Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
About This Chapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Planning Your Wiring Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
SCP Positions and Channel Numbers . . . . . . . . . . . . . . . . . . . . . . . . 34
Sense SCPs and Output SCPs . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Planning for Thermocouple Measurements . . . . . . . . . . . . . . . . . . . . . 36
Terminal Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
The SCPs and Terminal Module . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Terminal Module Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Reference Temperature Sensing with the HP E1313 . . . . . . . . . . . . . . . . . . . 40
Reference Temperature Sensing with the HP E1413 . . . . . . . . . . . . . . . . . . . 41
Preferred Measurement Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Connecting the On-Board Thermistor . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Adding Components to the HP E1413 Terminal Module . . . . . . . . . . . . . . . . . 48
Wiring/Attaching the HP E1313 Terminal Module . . . . . . . . . . . . . . . . . . . . 49
Wiring the HP E1413 Terminal Module . . . . . . . . . . . . . . . . . . . . . . . . . 50
Attaching the HP E1413 Terminal Module . . . . . . . . . . . . . . . . . . . . . . . . 52
Removing the HP E1413 Terminal Module . . . . . . . . . . . . . . . . . . . . . . . . 53
Terminal Module Wiring Maps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Terminal Module Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Option A3E . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Option A3F . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Option A3F Pin-Out and Signal Lines . . . . . . . . . . . . . . . . . . . . . . . . 59
Connecting and Mounting the HP E1586A Rack Mount Terminal Panel . . . . . . 61
Faceplate Connector Pin-Signal Lists . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
HP E1313A/E1413C High Speed A/D Module Contents 1
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Chapter 3. Using the HP E1313/E1413 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
About This Chapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Module Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Default Settings After Power-on, *RST, or *TST? . . . . . . . . . . . . . . . . . . . . 66
Programming Sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
Step 1. Setting-up Signal Conditioning Plug-ons . . . . . . . . . . . . . . . . . . . . . 70
Setting SCP Gains . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
Setting Filter Cutoff . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
Setting Current Sources . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
Step 2. Linking Channels to EU Conversion . . . . . . . . . . . . . . . . . . . . . . . 72
Linking Voltage Measurements . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
Linking Resistance Measurements . . . . . . . . . . . . . . . . . . . . . . . . . . 73
Linking Temperature Measurements . . . . . . . . . . . . . . . . . . . . . . . . . 75
Linking Strain Measurements . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
Linking Custom EU Conversions . . . . . . . . . . . . . . . . . . . . . . . . . . 79
Step 3. Performing Channel Calibration (Important!) . . . . . . . . . . . . . . . . . . . 81
Step 4. Defining and Selecting the Scan Lists . . . . . . . . . . . . . . . . . . . . . . . 83
Defining the Scan Lists . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
Selecting the Current Scan List . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
Step 5. Setting the Sample Timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
Step 6. Setting-up the Trigger System . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
The Trigger and Arm Model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
Selecting the Trigger Source . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
Selecting Timer and Continuous Mode Arm Source . . . . . . . . . . . . . . . . . 87
Setting the Trigger Counter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
Step 7. Specifying the Data Format . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
Step 8. Selecting the FIFO Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
Step 9. Initiating the Trigger System . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
Step 10. Retrieving Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
Accessing the CVT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
Accessing the FIFO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91
Example Program . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91
Example Command Sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
Using the HP E1586A Rack Mount Terminal Panel . . . . . . . . . . . . . . . . . . . 93
Thermistor Connections and Operations . . . . . . . . . . . . . . . . . . . . . . . 93
Reference Temperature Measurements . . . . . . . . . . . . . . . . . . . . . . . . 93
Chapter 4. Understanding the HP E1313/E1413 . . . . . . . . . . . . . . . . . . . . . . . 101
Advanced FIFO Data Retrieval . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101
General Form of the FIFO Data Retrieval Section . . . . . . . . . . . . . . . . . . 103
Choosing the Data Retrieval Method . . . . . . . . . . . . . . . . . . . . . . . . . 104
Controlling Data Conversion and Destination . . . . . . . . . . . . . . . . . . . . . . 108
Understanding Scanning Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109
Triggering and Scanning Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111
Continuous (Free-Run) Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111
Timer Paced Scans . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112
Sequenced Scan Lists . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113
Externally Paced Scans . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114
Synchronizing Multiple Cards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115
2 HP E1313A/E1413C High Speed A/D Module Contents
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Continuous (Free-Run) Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115
Internal Timer Based Scans . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116
Timer Based Scans at Different Rates . . . . . . . . . . . . . . . . . . . . . . . . 118
Using Automatic Scan List Sequencing (List-of-Lists) . . . . . . . . . . . . . . . . . . 120
A Simple Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120
Programming Four Different Rates . . . . . . . . . . . . . . . . . . . . . . . . . . 121
Setting the Absolute Scan Rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121
Using the Status System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122
Enabling Events to be Reported in the Status Byte . . . . . . . . . . . . . . . . . 123
Reading the Status Byte . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 127
Clearing the Enable Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . 127
The Status Byte Group’s Enable Register . . . . . . . . . . . . . . . . . . . . . . 128
Reading Status Groups Directly . . . . . . . . . . . . . . . . . . . . . . . . . . . 128
Updating the Status System and VXIbus Interrupts . . . . . . . . . . . . . . . . . . . . 129
HP E1313/E1413 Background Operation . . . . . . . . . . . . . . . . . . . . . . . . . 130
Averaging Readings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 131
Limit Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133
Checking Results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133
Custom EU Conversion Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 136
Compensating for System Offsets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138
Special Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 140
Detecting Open Transducers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141
Thermocouple Reference Compensation . . . . . . . . . . . . . . . . . . . . . . . . . 142
More On Autoranging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144
Reducing Settling Waits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144
Background . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144
Checking for Problems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 145
Fixing the Problem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 145
Chapter 5. HP E1313/E1413 Command Reference . . . . . . . . . . . . . . . . . . . . . . 149
ABORt . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 159
ARM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 160
ARM[:IMMediate] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 161
ARM:SOURce . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 161
ARM:SOURce? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 162
CALCulate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 163
CALCulate:AVERage:COUNt . . . . . . . . . . . . . . . . . . . . . . . . . . . . 164
CALCulate:AVERage:COUNt? . . . . . . . . . . . . . . . . . . . . . . . . . . . 164
CALCulate:AVERage[:STATe] . . . . . . . . . . . . . . . . . . . . . . . . . . . 165
CALCulate:AVERage[:STATe]? . . . . . . . . . . . . . . . . . . . . . . . . . . . 165
CALCulate:CLIMits:FAIL[:CUMulative]? . . . . . . . . . . . . . . . . . . . . . 166
CALCulate:CLIMits:FAIL:CURRent? . . . . . . . . . . . . . . . . . . . . . . . . 166
CALCulate:CLIMits:FLIMits[:CHANnels][:CUMulative]? . . . . . . . . . . . . 167
CALCulate:CLIMits:FLIMits[:CHANnels]:CURRent? . . . . . . . . . . . . . . . 167
CALCulate:CLIMits:FLIMits:POINts[:CUMulative]? . . . . . . . . . . . . . . . 168
CALCulate:CLIMits:FLIMits:POINts:CURRent? . . . . . . . . . . . . . . . . . . 168
CALCulate:LIMit:FAIL[:CUMulative]? . . . . . . . . . . . . . . . . . . . . . . . 168
CALCulate:LIMit:FAIL:CURRent? . . . . . . . . . . . . . . . . . . . . . . . . . 169
HP E1313A/E1413C High Speed A/D Module Contents 3
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

CALCulate:LIMit:LOWer:DATA . . . . . . . . . . . . . . . . . . . . . . . . . . 169
CALCulate:LIMit:LOWer:DATA? . . . . . . . . . . . . . . . . . . . . . . . . . 170
CALCulate:LIMit:LOWer[:STATe] . . . . . . . . . . . . . . . . . . . . . . . . . 170
CALCulate:LIMit:LOWer[:STATe]? . . . . . . . . . . . . . . . . . . . . . . . . 171
CALCulate:LIMit[:STATe] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 171
CALCulate:LIMit[:STATe]? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 172
CALCulate:LIMit:UPPer:DATA . . . . . . . . . . . . . . . . . . . . . . . . . . . 172
CALCulate:LIMit:UPPer:DATA? . . . . . . . . . . . . . . . . . . . . . . . . . . 173
CALCulate:LIMit:UPPer[:STATe] . . . . . . . . . . . . . . . . . . . . . . . . . . 173
CALCulate:LIMit:UPPer[:STATe]? . . . . . . . . . . . . . . . . . . . . . . . . . 174
CALibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 175
CALibration:CONFigure:RESistance . . . . . . . . . . . . . . . . . . . . . . . . 177
CALibration:CONFigure:VOLTage . . . . . . . . . . . . . . . . . . . . . . . . . 177
CALibration:SETup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 179
CALibration:SETup? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 179
CALibration:STORe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 180
CALibration:TARE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 181
CALibration:TARE? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 183
CALibration:TARE:RESet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 184
CALibration:VALue:RESistance . . . . . . . . . . . . . . . . . . . . . . . . . . . 184
CALibration:VALue:VOLTage . . . . . . . . . . . . . . . . . . . . . . . . . . . 185
CALibration:ZERO? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 186
DIAGnostic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 187
DIAGnostic:CALibration:TARE[:OTDetect][:MODE] . . . . . . . . . . . . . . . 188
DIAGnostic:CALibration:TARE[:OTDetect][:MODE]? . . . . . . . . . . . . . . 188
DIAGnostic:CHECksum? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 189
DIAGnostic:COMMand:SCPWRITE . . . . . . . . . . . . . . . . . . . . . . . . 189
DIAGnostic:CUSTom:LINear . . . . . . . . . . . . . . . . . . . . . . . . . . . . 190
DIAGnostic:CUSTom:PIECewise . . . . . . . . . . . . . . . . . . . . . . . . . . 191
DIAGnostic:CUSTom:REFerence:TEMPerature . . . . . . . . . . . . . . . . . . 192
DIAGnostic:FLOor[:CONFigure] . . . . . . . . . . . . . . . . . . . . . . . . . . 192
DIAGnostic:FLOor:DUMP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 193
DIAGnostic:INTerrupt[:LINe] . . . . . . . . . . . . . . . . . . . . . . . . . . . . 193
DIAGnostic:INTerrupt[:LINe]? . . . . . . . . . . . . . . . . . . . . . . . . . . . 194
DIAGnostic:OTDetect[:STATe] . . . . . . . . . . . . . . . . . . . . . . . . . . . 194
DIAGnostic:OTDetect[:STATe]? . . . . . . . . . . . . . . . . . . . . . . . . . . 195
DIAGnostic:QUERy:SCPREAD? . . . . . . . . . . . . . . . . . . . . . . . . . . 195
DIAGnostic:VERSion? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 196
FETCh? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 197
FORMat . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 199
FORMat[:DATA] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 199
FORMat[:DATA]? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 201
INITiate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 202
INITiate:CONTinuous . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 202
INITiate[:IMMediate] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 203
INPut . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 204
INPut:FILTer[:LPASs]:FREQuency . . . . . . . . . . . . . . . . . . . . . . . . . 204
4 HP E1313A/E1413C High Speed A/D Module Contents
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

INPut:FILTer[:LPASs]:FREQuency? . . . . . . . . . . . . . . . . . . . . . . . . 205
INPut:FILTer[:LPASs][:STATe] . . . . . . . . . . . . . . . . . . . . . . . . . . . 206
INPut:FILTer[:LPASs][:STATe]? . . . . . . . . . . . . . . . . . . . . . . . . . . 206
INPut:GAIN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 207
INPut:GAIN? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 207
INPut:LOW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 208
INPut:LOW? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 208
MEMory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 209
MEMory:VME:ADDRess . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 210
MEMory:VME:ADDRess? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 210
MEMory:VME:SIZE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 211
MEMory:VME:SIZE? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 211
MEMory:VME:STATe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 212
MEMory:VME:STATe? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 212
OUTPut . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 213
OUTPut:CURRent:AMPLitude . . . . . . . . . . . . . . . . . . . . . . . . . . . 213
OUTPut:CURRent:AMPLitude? . . . . . . . . . . . . . . . . . . . . . . . . . . . 214
OUTPut:CURRent[:STATe] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 215
OUTPut:CURRent[:STATe]? . . . . . . . . . . . . . . . . . . . . . . . . . . . . 215
OUTPut:SHUNt[:STATe] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 216
OUTPut:SHUNt[:STATe]? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 216
OUTPut:TTLTrg:SOURce . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 217
OUTPut:TTLTrg:SOURce? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 218
OUTPut:TTLTrg<n>[:STATe] . . . . . . . . . . . . . . . . . . . . . . . . . . . . 218
OUTPut:TTLTrg<n>[:STATe]? . . . . . . . . . . . . . . . . . . . . . . . . . . . 218
OUTPut:VOLTage:AMPLitude . . . . . . . . . . . . . . . . . . . . . . . . . . . 219
OUTPut:VOLTage:AMPLitude? . . . . . . . . . . . . . . . . . . . . . . . . . . . 219
ROUTe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 220
ROUTe:SCAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 220
ROUTe:SEQuence:DEFine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 222
ROUTe:SEQuence:DEFine? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 224
ROUTe:SEQuence:POINts? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 225
SAMPle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 226
SAMPle:TIMer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 226
SAMPle:TIMer? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 227
[SENSe:] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 228
[SENSe:]DATA:CVTable? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 229
[SENSe:]DATA:CVTable:RESet . . . . . . . . . . . . . . . . . . . . . . . . . . 230
[SENSe:]DATA:FIFO[:ALL]? . . . . . . . . . . . . . . . . . . . . . . . . . . . . 230
[SENSe:]DATA:FIFO:COUNt? . . . . . . . . . . . . . . . . . . . . . . . . . . . 231
[SENSe:]DATA:FIFO:COUNt:HALF? . . . . . . . . . . . . . . . . . . . . . . . 231
[SENSe:]DATA:FIFO:HALF? . . . . . . . . . . . . . . . . . . . . . . . . . . . . 232
[SENSe:]DATA:FIFO:MODE . . . . . . . . . . . . . . . . . . . . . . . . . . . . 233
[SENSe:]DATA:FIFO:MODE? . . . . . . . . . . . . . . . . . . . . . . . . . . . 233
[SENSe:]DATA:FIFO:PART? . . . . . . . . . . . . . . . . . . . . . . . . . . . . 234
[SENSe:]DATA:FIFO:RESet . . . . . . . . . . . . . . . . . . . . . . . . . . . . 235
[SENSe:]FILTer[:LPASs][:STATe] . . . . . . . . . . . . . . . . . . . . . . . . . 235
HP E1313A/E1413C High Speed A/D Module Contents 5
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

[SENSe:]FILTer[:LPASs][:STATe]? . . . . . . . . . . . . . . . . . . . . . . . . . 236
[SENSe:]FUNCtion:CUSTom . . . . . . . . . . . . . . . . . . . . . . . . . . . . 236
[SENSe:]FUNCtion:CUSTom:REFerence . . . . . . . . . . . . . . . . . . . . . . 237
[SENSe:]FUNCtion:CUSTom:TCouple . . . . . . . . . . . . . . . . . . . . . . . 238
[SENSe:]FUNCtion:RESistance . . . . . . . . . . . . . . . . . . . . . . . . . . . 240
[SENSe:]FUNCtion:STRain:FBENding . . . . . . . . . . . . . . . . . . . . . . . 241
[SENSe:]FUNCtion:TEMPerature . . . . . . . . . . . . . . . . . . . . . . . . . . 243
[SENSe:]FUNCtion:VOLTage[:DC] . . . . . . . . . . . . . . . . . . . . . . . . . 245
[SENSe:]REFerence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 246
[SENSe:]REFerence:TEMPerature . . . . . . . . . . . . . . . . . . . . . . . . . . 247
[SENSe:]STRain:EXCitation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 248
[SENSe:]STRain:EXCitation? . . . . . . . . . . . . . . . . . . . . . . . . . . . . 248
[SENSe:]STRain:GFACtor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 249
[SENSe:]STRain:GFACtor? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 249
[SENSe:]STRain:POISson . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 250
[SENSe:]STRain:POISson? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 250
[SENSe:]STRain:UNSTrained . . . . . . . . . . . . . . . . . . . . . . . . . . . . 251
[SENSe:]STRain:UNSTrained? . . . . . . . . . . . . . . . . . . . . . . . . . . . 251
STATus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 252
STATus:OPERation:CONDition? . . . . . . . . . . . . . . . . . . . . . . . . . . 254
STATus:OPERation:ENABle . . . . . . . . . . . . . . . . . . . . . . . . . . . . 255
STATus:OPERation:ENABle? . . . . . . . . . . . . . . . . . . . . . . . . . . . . 255
STATus:OPERation[:EVENt]? . . . . . . . . . . . . . . . . . . . . . . . . . . . . 256
STATus:OPERation:NTRansition . . . . . . . . . . . . . . . . . . . . . . . . . . 256
STATus:OPERation:NTRansition? . . . . . . . . . . . . . . . . . . . . . . . . . 257
STATus:OPERation:PTRansition . . . . . . . . . . . . . . . . . . . . . . . . . . 257
STATus:OPERation:PTRansition? . . . . . . . . . . . . . . . . . . . . . . . . . . 258
STATus:PRESet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 258
STATus:QUEStionable:CONDition? . . . . . . . . . . . . . . . . . . . . . . . . 259
STATus:QUEStionable:ENABle . . . . . . . . . . . . . . . . . . . . . . . . . . . 260
STATus:QUEStionable:ENABle? . . . . . . . . . . . . . . . . . . . . . . . . . . 260
STATus:QUEStionable[:EVENt]? . . . . . . . . . . . . . . . . . . . . . . . . . . 261
STATus:QUEStionable:NTRansition . . . . . . . . . . . . . . . . . . . . . . . . 261
STATus:QUEStionable:NTRansition? . . . . . . . . . . . . . . . . . . . . . . . . 262
STATus:QUEStionable:PTRansition . . . . . . . . . . . . . . . . . . . . . . . . . 262
STATus:QUEStionable:PTRansition? . . . . . . . . . . . . . . . . . . . . . . . . 263
SYSTem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 264
SYSTem:CTYPe? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 264
SYSTem:ERRor? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 264
SYSTem:VERSion? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 265
TRIGger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 266
TRIGger:COUNt . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 268
TRIGger:COUNt? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 268
TRIGger[:IMMediate] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 269
TRIGger:SOURce . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 269
TRIGger:SOURce? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 270
6 HP E1313A/E1413C High Speed A/D Module Contents
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

TRIGger:TIMer:MODE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 270
TRIGger:TIMer:MODE? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 272
TRIGger:TIMer[:PERiod] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 273
TRIGger:TIMer[:PERiod]? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 274
Common Command Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 275
*CAL? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 275
*CLS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 276
*DMC <name>,<cmd_data> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 276
*EMC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 276
*EMC? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 276
*ESE <mask> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 277
*ESE? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 277
*ESR? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 277
*GMC? <name> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 277
*IDN? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 277
*LMC? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 278
*OPC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 278
*OPC? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 278
*PMC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 279
*RMC <name> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 279
*RST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 279
*SRE <mask> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 280
*SRE? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 280
*STB? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 280
*TRG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 280
*TST? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 281
*WAI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 283
Command Quick Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 284
Chapter 6. Signal Conditioning Plug-on Manuals . . . . . . . . . . . . . . . . . . . . . . . 291
Appendix A. Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 293
Appendix B. Error Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 323
Appendix C. Glossary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 331
Appendix D. Register-Based Programming . . . . . . . . . . . . . . . . . . . . . . . . . . 333
Register Addressing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 336
Required VXI Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 338
ID Register Base + 0016 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 338
Device Type Register Base + 0216 . . . . . . . . . . . . . . . . . . . . . . . . . . 339
VXI Status Register Base + 0416 . . . . . . . . . . . . . . . . . . . . . . . . . . . 339
VXI Control Register Base + 0416 . . . . . . . . . . . . . . . . . . . . . . . . . . 340
Offset Register Base + 0616 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 341
HP E1313A/E1413C High Speed A/D Module Contents 7
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Query Response Register Base + 0816 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 341
Command and Parameter Registers Base + 0816-0E16 . . . . . . . . . . . . . . . . 342
Scan Status and Control Register Base + 1016 . . . . . . . . . . . . . . . . . . . . 342
Card Control Register Base + 1216 . . . . . . . . . . . . . . . . . . . . . . . . . . 345
Interrupt Configuration Register Base + 1416 . . . . . . . . . . . . . . . . . . . . 347
Interrupt Status Register Base + 1616 . . . . . . . . . . . . . . . . . . . . . . . . . 347
Common Capabilities Register Base + 1A16 . . . . . . . . . . . . . . . . . . . . . . . . . . . 349
Description Register Base + 1C16 . . . . . . . . . . . . . . . . . . . . . . . . . . 350
Subclass Register Base + 1E16 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 351
FIFO MSW and LSW Registers Base + 2016 and 2216 . . . . . . . . . . . . . . . . . . . . 351
FIFO Status Register Base + 2416 . . . . . . . . . . . . . . . . . . . . . . . . . . 352
FIFO Reading Count Register Base + 2A16 . . . . . . . . . . . . . . . . . . . . . 353
Software Trigger/ARM Register Base + 2616 . . . . . . . . . . . . . . . . . . . . 353
Trigger Timer Register Base + 2C16 . . . . . . . . . . . . . . . . . . . . . . . . . 353
Trigger Mode Register Base + 2E16 . . . . . . . . . . . . . . . . . . . . . . . . . 354
System Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 358
Calibration Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 363
Scan List Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 367
CVT Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 372
Trigger System Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 373
Debugging Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 373
Register-Based Programming Fundamentals . . . . . . . . . . . . . . . . . . . . . . . 375
Programming Sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 382
Reset Module to Default State . . . . . . . . . . . . . . . . . . . . . . . . . . . . 382
Programming Module After Reset Sequence . . . . . . . . . . . . . . . . . . . . . 383
Appendix E. Using HP VEE with the HP E1313/E1413 . . . . . . . . . . . . . . . . . . . . 385
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 385
How to Use HP VEE with the HP E1313/E1413 . . . . . . . . . . . . . . . . . . . . . 385
Using HP VEE with Direct VXI Backplane Access . . . . . . . . . . . . . . . . . 391
Using HP VEE for 100 K Sample Speed . . . . . . . . . . . . . . . . . . . . . . . 393
Using HP VEE with a Command Module . . . . . . . . . . . . . . . . . . . . . . 394
Measurement Speeds in HP VEE . . . . . . . . . . . . . . . . . . . . . . . . . . . 395
Appendix F. Wiring and Noise Reduction Methods . . . . . . . . . . . . . . . . . . . . . . 401
Recommended Wiring and Noise Reduction Techniques . . . . . . . . . . . . . . . . . 401
Wiring Checklist . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 401
HP E1313/E1413 Guard Connections . . . . . . . . . . . . . . . . . . . . . . . . 402
Common Mode Voltage Limits . . . . . . . . . . . . . . . . . . . . . . . . . . . . 402
When to Make Shield Connections . . . . . . . . . . . . . . . . . . . . . . . . . . 402
Noise Due to Inadequate Card Grounding . . . . . . . . . . . . . . . . . . . . . . . . 402
HP E1313/E1413 Noise Rejection . . . . . . . . . . . . . . . . . . . . . . . . . . . . 402
Normal Mode Noise (Enm) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 403
Common Mode Noise (Ecm) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 403
Keeping Common Mode Noise Out of the Amplifier . . . . . . . . . . . . . . . . 403
Reducing Common Mode Rejection Using Tri-Filar Transformers . . . . . . . . . 404
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 407
8 HP E1313A/E1413C High Speed A/D Module Contents
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Certification
Hewlett-Packard Company certifies that this product met its published specifications at the time of shipment from the factory. Hewlett-
Packard further certifies that its calibration measurements are traceable to the United States National Institute of Standards and Technol-
ogy (formerly National Bureau of Standards), to the extent allowed by that organization’s calibration facility, and to the calibration
facilities of other International Standards Organization members.
Warranty
This Hewlett-Packard product is warranted against defects in materials and workmanship for a period of three years from date of ship-
ment. Duration and conditions of warranty for this product may be superseded when the product is integrated into (becomes a part of)
other HP products. During the warranty period, Hewlett-Packard Company will, at its option, either repair or replace products which
prove to be defective.
For warranty service or repair, this product must be returned to a service facility designated by Hewlett-Packard (HP). Buyer shall pre-
pay shipping charges to HP and HP shall pay shipping charges to return the product to Buyer. However, Buyer shall pay all shipping
charges, duties, and taxes for products returned to HP from another country.
HP warrants that its software and firmware designated by HP for use with a product will execute its programming instructions when
properly installed on that product. HP does not warrant that the operation of the product, or software, or firmware will be uninterrupted
or error free.
Limitation Of Warranty
The foregoing warranty shall not apply to defects resulting from improper or inadequate maintenance by Buyer, Buyer-supplied prod-
ucts or interfacing, unauthorized modification or misuse, operation outside of the environmental specifications for the product, or im-
proper site preparation or maintenance.
The design and implementation of any circuit on this product is the sole responsibility of the Buyer. HP does not warrant the Buyer’s
circuitry or malfunctions of HP products that result from the Buyer’s circuitry. In addition, HP does not warrant any damage that oc-
curs as a result of the Buyer’s circuit or any defects that result from Buyer-supplied products.
NO OTHER WARRANTY IS EXPRESSED OR IMPLIED. HP SPECIFICALLY DISCLAIMS THE IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
Exclusive Remedies
THE REMEDIES PROVIDED HEREIN ARE BUYER’S SOLE AND EXCLUSIVE REMEDIES. HP SHALL NOT BE LIABLE
FOR ANY DIRECT, INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, WHETHER BASED ON CON-
TRACT, TORT, OR ANY OTHER LEGAL THEORY.
Notice
The information contained in this document is subject to change without notice. HEWLETT-PACKARD (HP) MAKES NO WAR-
RANTY OF ANY KIND WITH REGARD TO THIS MATERIAL, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WAR-
RANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. HP shall not be liable for errors contained
herein or for incidental or consequential damages in connection with the furnishing, performance or use of this material. This docu-
ment contains proprietary information which is protected by copyright. All rights are reserved. No part of this document may be photo-
copied, reproduced, or translated to another language without the prior written consent of Hewlett-Packard Company. HP assumes no
responsibility for the use or reliability of its software on equipment that is not furnished by HP.
U.S. Government Restricted Rights
The Software and Documentation have been developed entirely at private expense. They are delivered and licensed as “commercial
computer software” as defined in DFARS 252.227-7013 (October 1988), DFARS 252.211-7015 (May 1991) or DFARS 252.227-7014
(June 1995), as a “commercial item” as defined in FAR 2.101(a), or as “Restricted computer software” as defined in FAR 52.227-19
(June 1987) (or any equivalent agency regulation or contract clause), whichever is applicable. You have only those rights provided for
such Software and Documentation by the applicable FAR or DFARS clause or the HP standard software agreement for the product involved.
HP E1313A/E1413C User’s Manual
Edition 6
Copyright © 1996 Hewlett-Packard Company. All Rights Reserved.
HP E1313A/E1413C User’s Manual 9
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Frame or chassis ground terminal—typi-
cally connects to the equipment’s metal
frame.
Alternating current (AC).
Direct current (DC).
Indicates hazardous voltages.
Calls attention to a procedure, practice, or
condition that could cause bodily injury or
death.
Calls attention to a procedure, practice, or con-
dition that could possibly cause damage to
equipment or permanent loss of data.
Indicates the field wiring terminal that must
be connected to earth ground before operat-
ing the equipment—protects against electri-
cal shock in case of fault.
Instruction manual symbol affixed to prod-
uct. Indicates that the user must refer to the
manual for specific WARNING or CAU-
TION information to avoid personal injury
or damage to the product.
or
WARNINGS
The following general safety precautions must be observed during all phases of operation, service, and repair of this product.
Failure to comply with these precautions or with specific warnings elsewhere in this manual violates safety standards of design,
manufacture, and intended use of the product. Hewlett-Packard Company assumes no liability for the customer’s failure to
comply with these requirements.
Ground the equipment: For Safety Class 1 equipment (equipment having a protective earth terminal), an uninterruptible safety earth
ground must be provided from the mains power source to the product input wiring terminals or supplied power cable.
DO NOT operate the product in an explosive atmosphere or in the presence of flammable gases or fumes.
For continued protection against fire, replace the line fuse(s) only with fuse(s) of the same voltage and current rating and type.
DO NOT use repaired fuses or short-circuited fuse holders.
Keep away from live circuits: Operating personnel must not remove equipment covers or shields. Procedures involving the removal
of covers or shields are for use by service-trained personnel only. Under certain conditions, dangerous voltages may exist even with the
equipment switched off. To avoid dangerous electrical shock, DO NOT perform procedures involving cover or shield removal unless
you are qualified to do so.
DO NOT operate damaged equipment: Whenever it is possible that the safety protection features built into this product have been im-
paired, either through physical damage, excessive moisture, or any other reason, REMOVE POWER and do not use the product until
safe operation can be verified by service-trained personnel. If necessary, return the product to a Hewlett-Packard Sales and Service Of-
fice for service and repair to ensure that safety features are maintained.
DO NOT service or adjust alone: Do not attempt internal service or adjustment unless another person, capable of rendering first aid
and resuscitation, is present.
DO NOT substitute parts or modify equipment: Because of the danger of introducing additional hazards, do not install substitute
parts or perform any unauthorized modification to the product. Return the product to a Hewlett-Packard Sales and Service Office for
service and repair to ensure that safety features are maintained.
WARNING
CAUTION
Documentation History
All Editions and Updates of this manual and their creation date are listed below. The first Edition of the manual is Edition 1. The Edi-
tion number increments by 1 whenever the manual is revised. Updates, which are issued between Editions, contain replacement pages
to correct or add additional information to the current Edition of the manual. Whenever a new Edition is created, it will contain all of
the Update information for the previous Edition. Each new Edition or Update also includes a revised copy of this documentation his-
tory page.
Edition 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . May 1993
Edition 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . September 1993
Edition 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . March 1994
Edition 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . October 1994
Edition 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . February 1996
Edition 6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . August 1996
Safety Symbols
Trademarks
MS-DOS® is a U.S. registered trademark of Microsoft Corporation.
UNIX® is a registered trademark in the United States and other countries, licensed exculsively through X/Open Company Limited.
10 HP E1313A/E1413C User’s Manual
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Declaration of Conformity
according to ISO/IEC Guide 22 and EN 45014
Manufacturer’s Name: Hewlett-Packard Company
Loveland Manufacturing Center
Manufacturer’s Address: 815 14th Street S.W.
Loveland, Colorado 80537
declares, that the product:
Product Name: 32-Channel or 64-Channel Scanning A/D Converter
Model Number: HP E1313A
Product Options: All
conforms to the following Product Specifications:
Safety: IEC 1010-1 (1990) Incl. Amend 1 (1992)/EN61010-1 (1993)
CSA C22.2 #1010.1 (1992)
UL 1244
EMC: CISPR 11:1990/EN55011 (1991): Group 1, Class A
IEC 801-2:1991/EN50082-1 (1992): 4kV CD
IEC 801-3:1984/EN50082-1 (1992): 3V/m
IEC 801-4:1988/EN50082-1 (1992): 1kV Power Line
Supplementary Information: The product herewith complies with the requirements of the Low Voltage Directive
73/23/EEC and the EMC Directive 89/336/EEC.
Tested in a typical configuration in an HP B-Size VXI mainframe.
European contact: Your local Hewlett-Packard Sales and Service Office or Hewlett-Packard GmbH,
Department HQ-TRE, Herrenberger Straße 130, D-71034 Böblingen, Germany (FAX +49-7031-14-3143).
November 25, 1994 Jim White, QA Manager
HP E1313A/E1413C User’s Manual 11
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Declaration of Conformity
according to ISO/IEC Guide 22 and EN 45014
Manufacturer’s Name: Hewlett-Packard Company
Loveland Manufacturing Center
Manufacturer’s Address: 815 14th Street S.W.
Loveland, Colorado 80537
declares, that the product:
Product Name: 64-Channel Scanning A/D Converter
Model Number: HP E1413C
Product Options: All
conforms to the following Product Specifications:
Safety: IEC 1010-1 (1990) Incl. Amend 1 (1992)/EN61010-1 (1993)
CSA C22.2 #1010.1 (1992)
UL 3111
EMC: CISPR 11:1990/EN55011 (1991): Group 1 Class A
IEC 801-2:1991/EN50082-1 (1992): 4kV CD, 8kV AD
IEC 801-3:1984/EN50082-1 (1992): 3V/m
IEC 801-4:1988/EN50082-1 (1992): 1kV Power Line
0.5kV Signal Lines
Supplementary Information: The product herewith complies with the requirements of the Low Voltage Directive
73/23/EEC and the EMC Directive 89/336/EEC (inclusive 93/68/EEC) and carries the “CE” marking accordingly.
Tested in a typical configuration in an HP C-Size VXI mainframe.
European contact: Your local Hewlett-Packard Sales and Service Office or Hewlett-Packard GmbH,
Department HQ-TRE, Herrenberger Straße 130, D-71034 Böblingen, Germany (FAX +49-7031-14-3143).
March 15, 1996 Jim White, QA Manager
12 HP E1313A/E1413C User’s Manual
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Reader Comment Sheet
HP E1313A/E1413C User’s Manual
Edition 6
You can help us improve our manuals by sharing your comments and suggestions. In appreciation of your time, we will
enter you in a quarterly drawing for a Hewlett-Packard Palmtop Personal Computer (U.S. government employees
cannot participate in the drawing).
Please list the system controller, operating system, programming language, and plug-in modules you are using.
Please pencil-in one circle for each statement below: Disagree Agree
•Thedocumentationiswellorganized. OOOOO
•Instructions are easy to understand. OOOOO
•The documentation is clearly written. OOOOO
•Examples are clear and useful. OOOOO
•Illustrations are clear and helpful. OOOOO
•The documentation meets my overall expectations. OOOOO
Please write any comments or suggestions below—be specific.
cut along this line
fold here
Your Name
Company Name
Job Title
Address
City, State/Province
Country
Zip/Postal Code
Telephone Number with Area Code
BUSINESS REPLY MAIL
FIRST CLASS PERMIT NO. 37 LOVELAND, CO
HEWLETT-PACKARD COMPANY
Learning Products Department
P.O. Box 301
Loveland, CO 80539-9984
NO POSTAGE
NECESSARY
IF MAILED
IN THE
UNITED STATES
Measurement Systems Division
fold here
Please fold and tape for mailing
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

14 HP E1313A/E1413C User’s Manual
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Chapter 1
Getting Started
About This Chapter
Except where noted, all references to the HP E1413 apply to the
HP E1313. This chapter will explain hardware configuration before
installation in a VXIbus mainframe. By attending to each of these
configuration items, your HP Scanning A/D Converter module will not need
to be removed from its mainframe later. Chapter contents include:
•Configuring the HP Scanning A/D Converter
Module. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 15
•Instrument Drivers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 29
•About Example Programs . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 29
•Verifying a Successful Configuration . . . . . . . . . . . . . . . . . . Page 32
Configuring the HP Scanning A/D Converter Module
There are several aspects to configuring the module before installing it in a
VXIbus mainframe. They are:
•Setting the Logical Address Switch. . . . . . . . . . . . . . . . . . . . Page 16
•Installing HP E1313 Signal Conditioning Plug-ons . . . . . . . . Page 18
•Installing HP E1413 Signal Conditioning Plug-ons . . . . . . . . Page 22
•Disabling the Input Protect Feature. . . . . . . . . . . . . . . . . . . . Page 26
•Disabling Flash Memory Access. . . . . . . . . . . . . . . . . . . . . . Page 26
For most applications you will only need to change the logical address
switch prior to installation. The other settings can be used as delivered.
Switch/Jumper Setting
Logical Address Switch 24
Input Protect Jumper Protected
Flash Memory Protect Jumper PROG
Note Setting the VXIbus Interrupt Level: The HP Scanning A/D Converters use
a default VXIbus interrupt level of 1. The default setting is made at power-on
and after a *RST command. You can change the interrupt level by executing
the DIAGnostic:INTerrupt[:LINe] command in your application program.
Chapter 1 Getting Started 15
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Setting the Logical
Address Switch Follow Figures 1-1 and 1-2, and ignore any switch numbering printed on the
logical address switch. When installing more than one HP Scanning A/D
Converter in a single VXIbus mainframe, set each instrument to a different
logical address.
Figure 1-1. Setting the HP E1313 Logical Address
16 Getting Started Chapter 1
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Figure 1-2. Setting the HP E1413 Logical Address
Chapter 1 Getting Started 17
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Installing HP E1313
Signal Conditioning
Plug-ons
The following illustrations show the steps you will use to install the
HP E1313 Signal Conditioning Plug-on modules (SCPs).
CAUTION Use approved Static Discharge Safe handling procedures anytime you have
the covers removed from the HP Scanning A/D Converter modules or are
handling SCPs.
HP E1313 Step 1: Installing SCPs
Remove the cover(s) from the HP E1313
18 Getting Started Chapter 1
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

HP E1313 Step 2: Installing SCPs
NOTE: No more than four HP E1510A Sample and Hold (Option 020) SCPs can be used with an
individual HP E1313A.
CAUTION
Use approved Static
Discharge handling
procedures when handling
the HP E1313A Scanning
A/D Module and SCPs.
Chapter 1 Getting Started 19
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
This manual suits for next models
1
Table of contents
Other HP Media Converter manuals