LANs:
Client LAN Any NIC that is HP and Microsoft approved. See Client LAN below.
For a SPOFless cluster, two D5013B NICs configured with AFT is
recommended.
Intra-cluster
(Heartbeat) LAN Embedded NIC with crossover cable, or, configure as a VLAN through an
ethernet switch. See Intra-cluster LAN below.
Power source Direct from power mains, power conditioner or uninterruptible power
supply (UPS) using any power conditioner or UPS. Redundant power
distribution units (PDU’s) are strongly recommended.
System software:
Navigator version L.18.02 or later
Operating System Microsoft Windows 2000 Advanced Server
SPU
Model HP NetServer LH 3000
Clock speed 733, 800, 933 MHz
No. of CPUs 2
BIOS version 4.06.21 PT or later (733 MHz)
4.06.24 PT or later (800, 933 MHz)
CPU cache Anysize
RAM 256 MB minimum. Must be HP.
No. of power supplies 2 standard, 3 required for redundancy, 4 for power cord redundancy.
Local storage See Local Storage below.
I/O slot Added cards may be installed in any appropriate slot, keeping in mind the
server’s default boot order as listed below:
Default Boot Order IDE CD-ROM, FDD, SE SCSI C, Embedded A, Embedded B, PCI-8,
PCI-7, PCI64-6, PCI64-5, PCI64-4, PCI64-3, PCI64-2, PCI64-1
M/S Certified
Configuration M/S Certified Configuration:
P5 - Local Storage – NetRAID-1Si
P6 – Client LAN
P8 – Shared Storage- FC HBA
Booted from embedded DAC
Storage
Local
Controller May use embedded SCSI, embedded DAC, NetRAID-3Si or NetRAID-1Si.
For SPOFless, recommend embedded DAC with drives in RAID-1 mirror,
or another fault tolerant RAID level.
Driver For embedded SCSI, use sym_hi.sys from Windows 2000 Adv. Server CD
version 5.00.2134.1 or later.
For embedded DAC and NetRAID-xSi, use mraid35x.sys version 2.62
(Navigator L.18.04.5 or later).
Cabinets (Physical drive
location) SPU internal drive bays or HP external drive cabinet (e.g., HP Rack
Storage/12), any number.
Disk drives Must be HP (hot swap or fixed)
SCSI bus Any HP cables that meet SCSI specifications and any SCSI bus speed.
SCSI Ids Any