tc4100nt71-74
Server Configuration
Parameter Specification
I/O slots Added cards may be installed in any appropriate slot, considering the server
default boot order provided below.
Default boot order IDE CD-ROM, FDD, embedded SCSI A, embedded SCSI B, PCI slot 6, PCI slot
5, PCI slot 4, PCI slot 3, PCI slot 2, PCI slot 1, embedded LAN
Local Storage
Controller Embedded SCSI or NetRAID-1M
Driver For embedded SCSI, sym_u3.sys, version 5.09, or later
For NetRAID-1M, mraidnt.sys, version 4.05
(drivers obtained from Navigator CD-ROM, version M.04.60, or later)
Physical drive location Server internal drive bays, or HP external drive cabinet
(e.g., HP Rack Storage/12)
Disk drives Must be HP
SCSI bus Any HP cables that meet SCSI specifications, and any SCSI bus speed
SCSI IDs Any
System software
Navigator CD-ROM Version M.04.60, or later
Operating system
Service pack
Microsoft Window NTâServer 4.0, Enterprise Edition
SP6a
HP Surestore Auto Path
VA
Version 1.03.00 or later.
Required only if two Fibre Channel Host Bus Adapters are configured for shared
storage. No Load Balancing is set for the FC HBA devices on each node. See the
dual HBA diagrams on pages 5 and 6 for more information.
Shared Storage Configuration
Parameter Specification
Controller
Model HP D8602B Fibre Channel Host Bus Adapter
Number of controllers One or two
Dual HBA controller configurations require running HP Surestore Auto Path VA.
Note that the purpose of the second HBA is to provide an alternate path for
automatic failover only.
Driver Afcnt4.sys, version 3.0.4107.0
Registry settings N_Port enabled for Fabric configurations
NL_Port enabled for Arbitrated Loop configurations
Refer to the readme file included with the HBA driver for instructions on
modifying driver parameters.
RAID levels AutoRAID, or RAID 1+ 0
Logical disks Sixteen LUNs, maximum, per cluster
Enclosure HP Surestore Virtual Array 7100, Models A6261A, A6262A, or A6263A
HP Surestore Virtual Array 7400, Models A6264A, A6265A, or A6214A
Number of enclosures One or two per cluster
4/15/02 2