The appearance of your hardware components might
differ slightly from those presented in this document.
Replace the management module
The management module is located on the rear of the
chassis, above the controllers.
NOTE: To maintain configuration information,
such as IP address, perform this procedure with
power on.
Removing a management module
1. Unplug the Ethernet cable from the module.
2. Lift the latch on the module and pull the module
out slightly. See Figure 1 (page 2).
3. Position one hand under the module, and with
the other hand, pull the module out of the
controller enclosure.
Figure 1 Removing a management module
Installing a management module
1. Insert the new management module into the slot
until you hear a click indicating that it is fully
seated.
2. Attach the Ethernet cable to the module.
The new management module has HP P6000
Command View 10.1 or later pre-installed.
Upgrade the management and controller
software
1. Upgrade HP P6000 Command View to Version
10.1 or later on all server-based management
arrays.
IMPORTANT: Be sure that you upgrade
to the same version that is installed in the
new management module.
2. Upgrade the controller software to XCS
11001100 or later.
3. Verify the software upgrade before continuing.
For instructions, see the HP P6000 Command View
Installation Guide and the HP P6000 EVA Updating
Product Software Guide.
Shut down the array
Use HP P6000 Command View to perform an orderly
shut down and power off the array to be upgraded.
From HP P6000 Command View:
1. Select System Options.
2. Select Shutdown System.
3. Enter the delay time, and then click Power OFF.
4. Follow the prompts to complete the Power OFF.
NOTE: When the storage system is powered
off, the controller fault and link LEDs at both the
front and rear of the storage system and the
controller power button are all illuminated
amber. Also, the management module link LED
is illuminated and the activity LED flashes.
Remove controller 1
1. If necessary, label the cables that are connected
to the controller. This will facilitate reconnecting
them later.
2. Disconnect the host port and SAS cables from the
controller.
3. Remove the controller:
a. Loosen the mounting latch screw, and then
move the mounting latch to the right. See
Figure 2 (page 3). The controller will slightly
eject from the enclosure.
b. Position one hand under the controller, and
with the other hand, pull the controller out of
the enclosure.
Page 2