HTW P04 User manual

OWNER’S MANUAL
PORTABLE
P04
Thanks for choossing our product.
Please, read carefully this manual
before using the product
ENGLISH
HTW-DH-16P04

1
IMPORTANT INSTRUCTIONS
The following advice and instructions should be followed closely:
This will help you optimize the operation of your dehumidifier .
contains cooling agent. Failure to comply with
these instructions may
Do not install and use your dehumidifier before completely reading these instruction .
1.Your unit must always be used in an upright position because it
2.After unpacking Your unit, place the unit upright to allow the cooling
agent to stabilize , and wait 2 hours before use . damage the unit and will
of electrical and electronic appliances.
3.This product must not be disposed together with the domestic waste.
This product has to be disposed at an authorized place for recycling
4.The appliance shall not be installed in the laundry.
5.The appliance shall be installed in accordance with national wiring
regulations and must be positioned so that the plug is accessible.
invalidate the warranty .
7.Please check before the first operation:Check if the floater on bucket is at
right position. If the position is not correct, move it by hand to the right position.
6.If the power cord is damaged, it must be replaced by the manufacturer,
service agent or qualified person in order not to get any dangers.
CONTENTS
Safety Precautions ………………………………………......2
Operating Instructi
ons
About the controls on the dehumidifier ……………….…...3
How the Dehu midifier Operates ……………………………5
Automatic Defrost ……………………………………….….5
Choosing a Location …………………………………….….. 5
Removing Collected Water …………………….....………... 6
Water Level…………………………………………….…....6
Ca re and cleaning of the dehumidifier
Grille and Case ………………………………………........... 7
Water Bucket ………………………………………….......... 7
Troubleshooting …………………………………................. 8
Long term storage ………………………………..……........ 9
Specifications ……………………....…………..……............. 9
Air Filter ……………………......……………………...........7
.
.
.

IMPORTANT SAFETY INFORMATION.
READ ALL INSTRUCTIONS BEFORE USING.
When using this dehumidifier, always follow basic safety precautions, including the following:
SAFETY PRECAUTIONS
2
WARNING!
For your safety, the informatio n in this ma nu al must be follow ed to mi nimiz e the risk of fire, elect ric sho ck
or pe rson al inj ury.
allow children to use it as a toy .
Never connect the unit to a defective socket.
Do not operate any product with a damaged
Close supervision is necessary when any product
Always operate the product from a power source
indicated on the product identification plate .
of the same voltage,frequency and rating as
is used by or near children or invalids .Do not
cord or plug, or after the product malfunctions,
or is dropped or appears damaged in any way.
Return the complete product to the place of
purchase for inspection, repair or replacement.
To avoid tripping the circuit, DO NOT USE
AN EXTENSION CORD FOR THIS UNIT.
Make sure that the unit is correctly connected
before turning on the unit's power. Never lay
down the unit while it is working.
Always keep it in an upright position to avoid
any damage to the unit.
Switch off and unplug from outlet when not in
use or before cleaning.
To turn on your unit, always use the switch
on the control panel.
Never unplug the dehumidifier while it is
working, This could damage the electronic
circuits.
Never place anything on top of the unit and
do not cover it with any kind of cloth while it
is plugged in or in-use.
Do not place objects on the product or allow
objects to obstruct the inlet or outlet openings,
or operate in close proximity to walls or curtains,
etc.
The use of attachments or accessories not
recommended or sold by the product distributor
may cause personal or property hazards or injuries.
Keep the area around the warm air outlet
sufficiently clean and make sure that it is not
congested.
Do not place the power cord under a carpet.
Never install the unit in direct sunshine.
Prevent children from climbing on the unit.
This product is intended for normal domestic
/household use only.
Repairs should only be carried out by
competent service department.
This appliance is not intended for use by persons
(including children) with reduced physical, sensory
or mental capabilities,or lack of experience and
knowledge, unless they have been given supervision
or instruction concerning use of the appliance by a
person responsible for their safety.
Children should be supervised to ensure that they do
not play with the appliance.
Make sure that the unit is correctly connected
To avoid tripping the circuit, DO NOT USE

Other Features
BUCKET FULL Light
Glows when the bucket is ready to be emptied,
or when the bucket is removed or not replaced
in the proper position.
Alarm
If the bucket is full or missing for more than three
minutes, an alarm will sound for about 10 seconds
to remind you to empty and replace the bucket.
Auto Shut Off
The Water Level Control Switch shuts off the
dehumidifier when the bucket is full, or when
the bucket is removed or not replaced in the
proper position.
Auto Defrost
When frost builds up on the evaporator coils,
the compressor will cycle off and the fan will
continue to run until the frost disappears.
Power Outage
In the case of a power outage or interruption,
the unit will automatically restart, in the settings
last used, after the power is restored.
NOTE:
When the bucket is full or removed, the
controls cannot be set.
ON/OFF Pad
Press to turn the dehumidifier on and off.
FILTER Pad
After 250 hours of operation, the
Clean the
Filter
indicator light will glow to remind you to
clean the filter. Remove the filter and clean it.
Press to turn off the
Clean the Filter
light. See
the
Care and Cleaning
section.
Humidity Set Control Pads
The humidity level can be set within a range
of 80% RH (Relative Humidity) to 35% RH
(Relative Humidity) in 5% reduce or at
CO
for continuous operation.
NOTE:
If
CO
(Continuous) is selected, the
dehumidifier will operate continuously at
its maximum dehumidification settings if
attached to a hose to drain or until the
bucket is full.
For drier air, press the - pad and set to
a lower percent value (%).
For damper air, press the + pad and set
to a higher percent value (%).
When you first use the dehumidifier, set
the humidity control to 45% or 50%. Allow
at least 24 hours for the dehumidifier to
achieve the humidity level. If you still have
damper air than desired, set the humidity
level to a lower setting or select Continuous
for maximum dehumidification.
Display
Shows the set % humidity level while
setting, then shows the actual (+/– 5%
accuracy) room % humidity level.
FAN SPEED
Controls the fan speed.
Press to select High or Low fan
speed.
Set the fan control to High for maximum
moisture removal. When the humidity
has been reduced and quiet operation is
preferred, set the fan control to Low.
TIMER Pad
3
Controls
This unit has 3-min lag due to the device
for protecting circuit .In order to prolong
the compressor's working life, the compressor
will not start until the unit has run for 3 minutes.
If unit is turned on and running in timer mode
for 2hr or 4hr,can turn off the unit. When unit
stand by and running in timer mode for 2hr or
4
3
2
1
5
6
High and Low fan
indicator lights
Bucket full light indicates
bucket needs to be emptied
or it is not in the proper place
Continuous operation on
indicator light
Power On
indicator light Clean the Filter
indicator light
ABOUT THE CONTROLS ON THE DEHUMIDIFIER
(GDN16AJ-K4EBC1A GDN12AJ-K4EBC1A)
4 hour or 2 hour
fo/noyaled f
indicator lights

ABOUT THE CONTROLS ON THE DEHUMIDIFIER
Operation indicator
Bucket Full light indicates
bucket needs to be emptied
or is not in place in the unit
When frost builds up on the evaporator
coils,the compressor will cycle off and
the fan will continue to run until the
frost disappears.
OFF
Continuous
Switch off.
Dehumidifier continuously running.
Humidity control knob
Controls
(
GDN10AJ-K4MBC1A GDN08AJ-K4MBC1A
)
Other Features
Light Glows when the bucket is ready to be emptied,or when the bucket is removed or not
Alarm
If the bucket is full or missing for more than three minutes, an alarm will sound for about 10
Auto Shut Off
The W
ater Level Control Switch sh
uts off the dehumidifier when the bucket is full, or when
Auto Defrost
When frost builds up on the evaporator coils,the compressor will cycle off and the fan will
Power Outage
In the case of a power outage or interruption,the unit will automatically restart, in the settings
4
BUCKET FULL
seconds to remind you to empty and replace the bucket.
the bucket is removed or not replaced in the proper position.
continue to run until the frost disappears.
last used , after the power is restored.
replaced in the proper position.

When first using the dehumidifier, operate the unit continuously 24 hours.
How the Dehumidifier Operates
Moist, humid air is drawn over a cold refrigerated
dehumidifying coil. Moisture in the air condenses
on this coil and drains into a bucket (or through
a hose and drain).
Dry, clean air is drawn through the condenser
where it is heated and discharged out the top grille
into the room.
It is normal that the surrounding air to become slightly
warmer as the dehumidifier operates.
When frost builds up on the evaporator coils, the
compressor will cycle off and the fan will continue
to run until the frost disappears.
sehcni
40
5
Automatic Defrost
Choosing a Location
A dehumidifier operating in a basement will have
little or no effect in drying an adjacent enclosed
storage area, such as a closet, unless there is
adequate circulation of air in and out of the area.
Do not use outdoors.
This dehumidifier is intended for indoor residential
applications only. This dehumidifier should not be
used for commercial or industrial applications.
Place the dehumidifier on a smooth, level floor
strong enough to support the unit with a full bucket
of water.
Allow at least 12–18 inches of air space on all sides
of the unit for good air circulation(The place with a
draught leaves the distance of the wall as 40 inches).
Place the dehumidifier in an area where the
temperature will not below 5°C. Or the coils
can become covered with frost ,which may
reduce performance.
Use the dehumidifier to prevent moisture damage
anywhere books or valuables are stored.
The dehumidifier must be operated in an enclosed
area to be most effective.
Close all doors, windows and other outside openings
of the room.
YES NO
NOTE: The dehumidifier has rollers to aid placement,
but it should only be rolled on smooth, flat surfaces.
Do not attempt to roll the dehumidifier on carpet or
over objects.
In defrosting mode, fan motor normally run,
compressor stop running.
USING THE DEHUMIDIFIER
Use the dehumidifier in a basement to help prevent
moisture damage.

There are 2 ways to remove collected water:
Use the bucket.
When the bucket is removed,
the unit will shut off. Empty and replace the
bucket.
NOTES:
6
Always make sure the water bucket is locked into place on the dehumidifier.
Water Level
The dehumidifier will turn off automatically
when the bucket is full, or when the bucket is
removed or not replaced in the proper position.
The bucket must be replaced in the proper position for
the dehumidifier to work. The light will be on and the
dehumidifier will not run if the bucket is not in the
proper position.
Removing Collected Water
NOTE: Hold bucket with
both hands when emptying.
Important: Do not use the hose if using the
water tank to collect water. When the hose
is connected, water will be drained out through
it onto floor instead of into the tank.
Do not remove the bucket while the unit
is in operation or it has just stopped.
Otherwise it may cause some water to
drip from the draining pan.
The bucket must be in place and securely
seated for the dehumidifier to operate.
This is just the schematic plan, please refer
to the actual product.
2
3)
1)
Remove the continuous drain cap 1by turning it
counter
2 from the spout.
21
Screw the drain connector (included in the package)
to
the spout
by turning clockwise
Insert the drainage hose into drain connector.
USING THE DEHUMIDIFIER
Use a hose.Water can be automatically
emptied
into a floor drain by attaching a
diameter hose (not included).
clockwise then remove the rubber stopper
14mm inner

7
Turn the dehumidifier off and remove the plug from the wall outlet before cleaning.
Grille and Case
To clean the case:
Use water and a mild detergent. Do not use
bleach or abrasives.
To clean the front grille:
Use a vacuum attachment or brush.
Water Bucket
To clean:
Every few weeks, clean the bucket to prevent
growth of mold, mildew and bacteria. Partially fill
the bucket with clean water and add a little mild
detergent. Swish it around in the bucket, empty
and rinse.
NOTE: Do not use a dishwasher to clean the
water bucket.
To remove:
Remove the bucket and pour any water out.
To replace:
Slide the bucket into the dehumidifier.
NOTE: The bucket must be in place and securely seated
for the dehumidifier to operate.
Air Filter
The air filter checked and cleaned at
least eve ry 250 hours of operation or more
often if necessary.
After 250 hours of operation, the
Clean the Filter
indicator light will glow to remind you to clean the
filter. Remove the filter and clean it. Replace the
filter and press the
Filter
RESET
pad to turn off the
Clean the Filter
light.
To remove:
To clean:
Clean the filter with warm, soapy water. Rinse and
let the filter dry before replacing it.
NOTE: DO NOT rinse or put the filter in an automatic
dishwashe r.
Caution: Do not operate the dehumidifier
without a filter because dirt will gather and affect the
.ecnamrofreps'tinu
NOTE: Avoid using a dishwasher to clean the filter.
※
Press the two buttons, then pull out the filter.
should be
To install :
Put the filter back into the dehumidifier.
Buttons
CARE AND CLEANING OF THE DEHUMIDIFIER

8
Troubleshooting
Problem Possible Causes What To Do
Dehumidifier
The dehumidifier •Make sure the dehumidifier’s plug is pushed completely
does not start
is unplugged. into the outlet.
Dehumidifier has reached its •The dehumidifier automatically turns off when either
preset level or bucket is full. condition occurs. Change to a lower setting or empty
the bucket and replace properly.
Bucket is not in the •The bucket must be in place and securely seated for the
proper position. dehumidifier to operate.
Power failure. •There is a protective time delay (up to 3 minutes) to
prevent tripping of the compressor overload. For this
reason, the unit may not start normal dehumidifying
for 3 minutes after it is turned back on.
Dehumidifier does not
Did not allow enough time •When first installed, allow at least 24 hours to maintain
dry the air as it should
to remove the moisture. the desired dryness.
Airflow is restricted. •Make sure there are no curtains, blinds or furniture
blocking the front or back of the dehumidifier. See the
Choosing a Location
section.
Dirty filter. •See the
Care and Cleaning
section.
The Humidity Control may •For drier air, press the - pad and set to a lower percent
not be set low enough. value (%) or at
CO
(continuous) for maximum
dehumidification.
Doors and windows may not •Check
all doors, windows and other openings
be closed tightly. are securely closed.
Clothes dryer may be •Install the dehumidifier away from the dryer.
blowing moisture-laden The dryer should be vented to the outside.
air into the room.
Room temperature •Moisture removal is best at higher room temperatures.
is too low. Lower room temperatures will reduce the moisture
removal rate. Models are designed to be operated at
temperatures above 5°C.
Dehumidifier runs
Area to be dehumidified •The capacity of your dehumidifier may not be adequate.
too much
is too large.
Doors and windows are open. •Close all doors and windows to the outside.
Frost appears on
Dehumidifier has been recently •This is normal. Frost will usually disappear
the coils
turned on, or room temperature within 60 minutes. See the
Automatic Defrost
section.
is below 5°C.
Controls cannot be set
The compressor will turn off •This is normal. Wait approximately 3 minutes and set the
and the fan will automatically fan as desired.
continue to run for
approximately 3 minutes at a
fixed setting.
Fan noise
There is sound created when
wind passing the unit. That is
the sound of wind.
•This is normal.
Water on floor
Hose connection may be loose. •Check the hose connection. See the
Removing Collected
Water
section.
Intend to use the bucket to •Disconnect the hose if using the bucket to collect water.
collect water, but a hose See the
Removing Collected Water
section.
is attached.
“ ”

Make sure there is no water left in the water tank and take off the draining hose.
Clean the unit and packed it well to keep it from dust.
9
220-240 V~
50Hz
℃5℃-35
390W 340W 260W 255W
12kg 10.5kg 10.5kg 10.5kg
LONG TERM STORAGE
Specifications
Take off the power cord and plug and warp them well.
when you do not use the unit for a long period, we suggest you to take following steps to store the
unit in good condition;
Model
Rated Voltage
Rated Frequency
Rated Power
Moisture Removal(at 30℃,27.1℃)
Operating Temperature
Weight
Tank Capacity 3.5L(Automaticstop at about 3.0L)
GDN16AJ-K4EBC1A GDN12AJ-K4EBC1A GDN10AJ-K4MBC1A GDN08AJ-K4MBC1A
16L/DAY 12L/DAY 10L/DAY 8L/DAY

C./ Industria, 13 l Polígono Industrial El Pedregar
08160 Montmeló
Barcelona (Spain)
Phone: 93 390 42 20
Fax: 93 390 42 05
This manual suits for next models
1
Table of contents
Other HTW Dehumidifier manuals
Popular Dehumidifier manuals by other brands

Innovative Dehumidifier
Innovative Dehumidifier WH120 Installation and operation manual

Cotes
Cotes C35 Operating and service guide

Heat Controller
Heat Controller BHD-301 Service manual

EINHELL
EINHELL LE 10 Original operating instructions

Danby
Danby DDR040BFCWDB owner's manual

EINHELL
EINHELL LE 16 Original operating instructions