manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. HUBBELL LIGHTING
  6. •
  7. Outdoor Light
  8. •
  9. HUBBELL LIGHTING KIM LIGHTING VRB1 User manual

HUBBELL LIGHTING KIM LIGHTING VRB1 User manual

This manual suits for next models

3

Other HUBBELL LIGHTING Outdoor Light manuals

HUBBELL LIGHTING MATRIX Series User manual

HUBBELL LIGHTING

HUBBELL LIGHTING MATRIX Series User manual

HUBBELL LIGHTING KIM LIGHTING Kim Pavilion User manual

HUBBELL LIGHTING

HUBBELL LIGHTING KIM LIGHTING Kim Pavilion User manual

HUBBELL LIGHTING KIM LIGHTING B30 Series Installation and operating instructions

HUBBELL LIGHTING

HUBBELL LIGHTING KIM LIGHTING B30 Series Installation and operating instructions

HUBBELL LIGHTING RWL1 User manual

HUBBELL LIGHTING

HUBBELL LIGHTING RWL1 User manual

HUBBELL LIGHTING Kim Lighting B30-LED Series User manual

HUBBELL LIGHTING

HUBBELL LIGHTING Kim Lighting B30-LED Series User manual

HUBBELL LIGHTING KIM LIGHTING WARP9 WP9L User manual

HUBBELL LIGHTING

HUBBELL LIGHTING KIM LIGHTING WARP9 WP9L User manual

HUBBELL LIGHTING Architectural Area Lighting EPA-T User manual

HUBBELL LIGHTING

HUBBELL LIGHTING Architectural Area Lighting EPA-T User manual

HUBBELL LIGHTING KIM LIGHTING KLV206 User manual

HUBBELL LIGHTING

HUBBELL LIGHTING KIM LIGHTING KLV206 User manual

Popular Outdoor Light manuals by other brands

Kichler Lighting HELEN 37536 instructions

Kichler Lighting

Kichler Lighting HELEN 37536 instructions

Thorn OXANE L installation instructions

Thorn

Thorn OXANE L installation instructions

esotec Solar Globe Light multicolor 20 operating instructions

esotec

esotec Solar Globe Light multicolor 20 operating instructions

mitzi HL200201 ELLIS Assembly and mounting instructions

mitzi

mitzi HL200201 ELLIS Assembly and mounting instructions

HEPER TILA S AFX 3 Module Installation & maintenance instructions

HEPER

HEPER TILA S AFX 3 Module Installation & maintenance instructions

Designplan TRON 180 installation instructions

Designplan

Designplan TRON 180 installation instructions

Sealey LED37 instructions

Sealey

Sealey LED37 instructions

nordlux VEJERS Mounting instruction

nordlux

nordlux VEJERS Mounting instruction

SImx ELITE LED LHTC637 installation instructions

SImx

SImx ELITE LED LHTC637 installation instructions

GEV CAROLINE 10833 manual

GEV

GEV CAROLINE 10833 manual

WE-EF PFL540 LED Installation and maintenance instructions

WE-EF

WE-EF PFL540 LED Installation and maintenance instructions

HEPER DOGO Side LW6048.585-US Installation & maintenance instructions

HEPER

HEPER DOGO Side LW6048.585-US Installation & maintenance instructions

BEGA 84 253 Installation and technical information

BEGA

BEGA 84 253 Installation and technical information

HEPER LW8034.003-US Installation & maintenance instructions

HEPER

HEPER LW8034.003-US Installation & maintenance instructions

HEPER MINIMO Installation & maintenance instructions

HEPER

HEPER MINIMO Installation & maintenance instructions

LIGMAN BAMBOO 3 installation manual

LIGMAN

LIGMAN BAMBOO 3 installation manual

Maretti TUBE CUBE WALL 14.4998.04 quick start guide

Maretti

Maretti TUBE CUBE WALL 14.4998.04 quick start guide

Maxim Lighting Carriage House VX 40428WGOB installation instructions

Maxim Lighting

Maxim Lighting Carriage House VX 40428WGOB installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Tools Required:
F” Hex Key
5/32” Hex Key
G” Wrench
N” Open End Wrench
Ratchet with N” Deep Socket
Revised 9/01/10 ECN 100901003 Status 11 Part No. 95449
Vandal Resistant Bollard Installation Instructions
P.O. Box 60080 • 16555 East Gale Ave.
City of Industry, California 91716-0080
626/968-5666 • FAX 626/330-3861
WARNING: Fixtures must be grounded in accordance with local codes or the National Electrical Code.
Failure to do so may result in serious personal injury.
MAINTENANCE: To maintain light efficiency and prevent fixture overheating, globe must be kept clean and free of
dirt, dust, leaves, and trash. Globe should be regularly cleaned with a solution of ammonia and water or a suitable
glass cleaner.
NOTE: All electrical work must be done by a qualified electrician. KEEP THIS SHEET FOR FUTURE REFERENCE.
VRB2 & VRB4
Dual Function
VRB1 & VRB3
Single Function
Top Cap
Stacked
Vertical
Louvers
Pole Body
!Make certain the electrical supply is OFF before starting installation.
1. Install the base casting/ballast
assembly on the pre-set anchor
bolts. Use flat washers and hex
nuts both below and above the
base casting.
2. Level the top edge of the casting by
adjusting the bottom leveling nuts.
Tighten the upper nuts.
3. Tighten the upper nuts using a N"
deep socket.
4. Connect the circuit ground wire to
the green wire connected to the
grounding lug on the ballast
bracket. Connect power supply
leads to the ballast input leads,
green-to-ground, white-to-common
& black-to-voltage (see diagram).
BASE CASTING / BALLAST ASSEMBLY INSTALLATION INSTRUCTIONS:
NOTE: For incandescent fixtures,
connect the power supply leads directly
to the lamp leads - no ballast required.
Base/Ballast
Bracket Assembly
!
Page 2 Kim Lighting • 16555 E. Gale Ave. • P.O. Box 60080 • City of Industry, CA 91716-0080 • 626/968-5666 • FAX 626/330-3861
Vandal Resistant Bollard Installation Instructions
VRB1/VRB3 & VRB2/VRB4
4. Tighten the two C" set screws at
the bottom of the pole using a F”
ball end hex key.
FIXTURE INSTALLATION INSTRUCTIONS:
Make certain the electrical supply is OFF before starting fixture installation.
!
1. To protect finish, lay fixture horizontally on soft cloth with open-end of fixture next to installed base/casting
assembly.
2. Connect fixture ground lead
(green) to the green wire con-
nected to the grounding lug on the
ballast bracket. Connect the lamp
leads to the ballast. NOTE: For incandescent fixtures,
connect the power supply leads
directly to the lamp leads.
3. Place pole body over ballast
assembly and slowly turn until it
drops into retaining slots. Then
twist clockwise 45° to lock the pole
onto the base casting.
LAMP INSTALLATION OR REPLACEMENT INSTRUCTIONS:
Make certain electrical supply is OFF before starting installation or replacement.
1. Locate two J-20 button head socket screws (180°
apart) concealed under top cap. Feel for screw
heads approximately L” up under top cap
between vertical ribs. The screw heads are only
visible from low angles near the fixture body.
Loosen - do not remove - screws with a standard
5/32” hex key. Turn top cap clockwise and lift up to
remove.
!
All Field Wires and Connections
Must Remain Well Below Ballast
Level
Grade
Conduit Stub
Up 3" Max.
2. Remove J-20 hex nut securing one end of globe
retaining strap. Loosen the other hex nut and pivot
retaining strap to side or remove. Lift globe up to
remove.
Retaining
Strap
Globe Pressure Pad
Page 3 Kim Lighting • 16555 E. Gale Ave. • City of Industry, CA 91716-0080 • 626/968-5666 • FAX 626/330-3861
WARNING:
The H.I.D. / Fluorescent fixture utilizes a lamp that
may contain mercury. For information on disposal of
lamp go to website: www.lamprecycle.org
Vandal Resistant Bollard Installation Instructions
VRB1/VRB3 & VRB2/VRB4
3. Install lamp of type and wattage shown on fixture
label. Make sure globe gasket surface is clean.
Reinstall globe and retaining strap making certain
pressure pad is in place around retaining strap
before installing hex nuts.
4. Replace top cap by aligning screws with keyhole
slot openings. Turn top cap counterclockwise and
tighten screws.
BALLAST REPLACEMENT INSTRUCTIONS:
Make certain the electrical supply is OFF before starting replacement.
3. Place fixture over the ballast assembly and slowly turn until it drops into retaining slots; twist shaft clockwise 45° to
lock onto the base casting. Tighten the two set screws at the base of the fixture.
!
LAMP INSTALLATION OR REPLACEMENT INSTALLATION INSTRUCTIONS cont'd.
1. Loosen two J-20 set screws located near bottom
of fixture using a F” hex key. Rotate the fixture
counterclock-wise approximately 1” and lift upward
to clear ballast assembly.
2. Replace ballast with the correct type and wattage.
Connect all wiring as shown in the wiring diagram
on the new ballast.
Page 4 Kim Lighting • 16555 E. Gale Ave. • P.O. Box 60080 • City of Industry, CA 91716-0080 • 626/968-5666 • FAX 626/330-3861
How may we serve you better?
Please let us know. Visit our website at:
www.kimlighting.com
Your concerns are important to us.
KIM LIGHTING LIMITED WARRANTY
When installed in accordance with Kim Installation Instructions and accepted trade practices, the
following shall apply:
General Product Limited Warranty Coverage
All material and component parts used in the manufacture of Kim Products, are warranted to be free from
defects of material and/or workmanship for a period of 1 year from date of sale, with the following
exceptions:
Auxiliary Equipment
All auxiliary equipment (such as lamps, ballasts, and transformers) provided by and/or included in Kim
Products shall carry the component manufacturer's warranty.
Copper and Bronze Landscape Components
Copper and Bronze Landscape fixture components shall be warranted against defects of material and/or
workmanship, and failure due to corrosion, for a period of 25 years from date of sale.
Composite In-Grade Components
Composite In-Grade fixture components installed below grade, shall be warranted against defects of
material and/or workmanship, and failure due to corrosion, for a period of 7 years from date of sale.
Aluminum Landscape Components
Aluminum Landscape fixture components not in direct contact with soil, shall be warranted against
defects of material and/or workmanship for a period of 3 years from date of sale. Aluminum fixture
components in direct contact with soil shall be warranted from defects of material and failure from
corrosion for a period of 1 year from date of sale.
Limit of Liability and General Conditions
Only products which are installed, used and maintained in accordance with applicable Kim instructions,
specifications and accepted trade practices, are covered by the Kim Warranty. During the warranty
period, with proof of purchase, Kim will repair or replace with the same or similar product, at Kim's option,
without charge. Labor costs are the owner's responsibility and are excluded from this warranty. This
warranty is void if the product is modified, tampered with, misapplied, poorly installed, improperly
maintained, or subjected to abnormal conditions.
Repair or replacement as provided under this warranty is the exclusive remedy of the purchaser. This
warranty is in lieu of all other warranties, expressed or implied, including any implied warranty of fitness
for a particular application. Kim Lighting shall not be liable to the purchaser for indirect or consequential
damages.
Vandal Resistant Bollard Installation Instructions