Screw
O-Ring
Backplate
Cover
INSTALLATION OPERATION
120VAC Connect black (hot) and neutral (white)
to supply.
277VAC Connect black (hot) and neutral (white)
to supply.
Ground Connect ground (green) conductor.
IMPORTANT:
Once unit is connected and cover is snapped onto backplate, gently seat screws onto
O-ring seals to less than 1/2FT-LB (.7N-m).
DO NOT OVERTIGHTEN!
O-RING MAY BE DAMAGED AND THE UNIT WILL LEAK IF ABOVE IS NOT
FOLLOWED.
1.Open the unit by loosening both screws on top of unit until screws spin freely. Pry cover
from backplate, and remove cover squarely from backplate. (Remove screws prior to
re-installing cover.)
2.Remove 7/8” diameter K.O. from backplate if mounting to electrical
box or remove 1/2”-1/4NPT pipe plug if using conduit.
CONDUIT MOUNTING:
If unit is not secured to mounting surface using unit backplate
K.O. pattern and supplied gasket, use sealant to create
waterproof seal between the mounting surface and the unit
backplate.
IMPORTANT!
To weatherproof your outdoor installation, be sure to seal all
fixture openings - mounting, conduit, etc.
4.Peel backing from J-Box Gasket and adhere to
backplate around center K.O.
5.Feed building wires through center K.O. as
shown and secure backplate using screws
supplied with electrical box.
3.Remove appropriate backplate K.O.’s
for electrical box screws.
7.Connect AC wire harness to AC wire harness
on unit backplate.
AC Wire Harness
To Building Ground Wire
NOTE:
Feed wires and nuts back into electrical box through
backplate as shown.
9.Attach unit cover to backplate by
reversing Step 1. Ensure all wires
are within enclosure to avoid pinching
with cover.
Full Cut-off Shield Installation Photo-Cell Option
1.Slide tabs “A” between housing and lens gasket.
2.Pinch sides of shield inward and seat shield against lens.
3.Release pinched sides of shield to secure to unit.
There will be a delay of up to 2 minutes to prevent false switching due to
momentary flashes of light.
TABS “A”
Pinch sides inward
Unit will operate from 120 or 277VAC through 2 wire intelligent input.
Photo-cell option: Unit will operate on 120VAC only, through 2 wire input.
93021938
93021935
93036085
93036084
9303609693021939
6.Connect building AC wires to
AC harness wires.