Test results from nominal test EN 13229:
Nominal heating effect 6.4 kW
Flue gas temperature EN 13229 measurement point 273ºC
Flue gas temperature measured in the outlet socket 326ºC
Exhaust gas flow 5.5 g/s
Efficiency 80%
CO at 13% O20.061 %
Test result based on NS 3058:
Particle emissions 2.65 g/kg
The declaration of performance can be downloaded from our website, www.hwam.com.
Type plate and serial number
The insert comes with type plate and serial number on the inside of the outer casing:
Locate the unique serial number of your insert and make a note of it below so that it is always easily accessible.The serial number must always
be provided when contacting your HWAM retailer.
Serial number (starts with “F4”):
Floor plate
European,national and local regulations must be observed in terms of the size and thickness of a non-combustible floor covering the floor in front
of the combustion chamber opening.Ask your HWAM retailer for assistance.
Requirements for chimney and flue duct
The height of the chimney must ensure sufficient draught and prevent any smoke nuisance.As a general rule, satisfactory draught conditions are
achieved if the chimney is 4 m above the stove and at least 80 cm above the ridge. If the chimney is placed at side walls, the top of the chimney
should always be higher than the ridge or the tallest point of the roof.Always be aware of any national and/or local regulations applying to thatched
roofs and the location of the chimneys.
The insert requires a minimum draught of 11 Pa (measured at EN 13229 measurement point). If measured just above the smoke flue socket, the
chimney draught must be 18-20 Pa.
The chimney must have a minimum clearing of Ø 150 mm.The chimney must be provided with an easily accessible cleaning door.The chimney and
flue duct must be of flue classT400 and be CE marked. Furthermore, it must have obtained the classification of G in soot fire testing.The required
distance to combustible material must be complied with in accordance with the brand label.Ask your HWAM retailer for further information.
EAN S.nr.:
EN 13229:2001 /
A2:2 0 04
Inset app lia nces
fired b y solid fuel
HWAM A/S
Nydamsvej 53 - DK 8362 Hørning
Tel.: (+45) 86 92 18 33
Fax: (+45) 86 92 22 18
HWAM A/S
Nydamsvej 53
DK-8362 Hørning
Thermal output: 6.4 kW
Fuel types wood
Combustible materials – minimum di stance to non-combustible insulation:
- Side 50 mm
- Behind 50 mm
Information about insulation and other dimensions see installation instructions
Distance to furnishings front 1200 mm
CO Emission at 13% O20.061 % / 758 mg/m3
Particles at 13% O216 mg/m3
Energy effiency 80 %
Flue gas temperature EN 13229 measurement point 273 °C
Flue gas temperature measured in the outlet socket 326 °C
Laboratory registration number NB 1235
Test report 300-ELAB-2402-EN
300-ELAB-2471-EN
The appliance is capable of intermittent operation.
The appliance can be used in a shared flue.
Follow the user’s manual and use only recommended fuel.
Declaration of Performance: www.hwam.com/dop/i40 -55
Brensel ved
Partikulær utslipp 2,65 g/kg
Prøvningsinstitutt NB 1235
Prøvningsrapport 300-ELAB-2402-NS
NS 3 058
NS 3 059
HWAM I 40/55
19
Norm Österreich 15a B-VG 300-ELAB-2402-AUS
Thermal output: 6.4 kW
Energy effiency 80 %
CO 383 mg/MJ
Particles 11 mg/MJ
NOx63 mg/MJ
OGC 14 mg/MJ
15A