Pre Installation Check List
Before you begin an installation, review your plans, check to see:
Your stove and chimney connector will be far enough from combustible material
to meet all clearance requirements.
The floor protection is large enough and is constructed properly to meet all
requirements.
You have all necessary permits from your local authorities. Your local building
official is the final authority for approving your installationas safe and in determining
that it meets all local and state building and safety codes.
The metal label permanently attached to the back of every HWAM wood-burning stove
shows that it has been tested to current UL and ULC safety standards, and gives the
name of the testing laboratory. Clearance and installation information is also printed on
the label. Local authorities will generally accept the label as evidence that, when the
stove is installed according to the information on the label and in this manual, the
installation meets codes and can be approved.
This wood stove must be connected to 1) a chimney complying with the requirements
for Type HTchimneys in the standard for Chimneys, Factory-Built, Residential Type and
Building HeatingAppliance, UL 103, or 2) a code-approved masonry chimney with a flue
liner. Due to the height if the HWAM Classic 7 flue outlet it is not possible to connect the
Classic 7 through an existing masonary or factory built fireplace.
For any unresolved questions about installation in the USA, refer to the national Fire
ProtectionAssociation’s publicationANSI/NFPA211 Standard for Chimneys, Fireplaces,
Vents and Solid Fuel BurningAppliances. For installation in Canada, refer to CSA CAN-
B365, Installation Code for Solid Fuel Burning Applications abd Equipment. These
standards are the basis for many national codes. They are nationally recognized and
are accepted by most local authorities. Your local dealer or your local building official
may have a copy of these regulations.
WARNING!
CHECK ALL LOCAL BUILDING AND SAFETY CODES BEFORE INSTALLATION.
THE INSTALLATION INSTRUCTIONS AND APPROPRIATE CODE REQUIREMENTS
MUST BE FOLLOWED EXACTLY AND WITHOUT COMPROMISE. ALTERATIONS
TO THE STOVE ARE NOT ALLOWED. DO NOT CONNECT THE STOVE TO A
CHIMNEY SYSTEM SERVING ANOTHER STOVE, APPLIANCE OR ANY AIR
DISTRIBUTION DUCT. FAILURE TO FOLLOW THESE INSTRUCTIONS WILL VOID
THE MANUFACTURERS WARRANTY.
NOTE
If you plan to vent your stove into an existing masonry chimney, have the chimney