MI15.450H
05NOV02
OK REWORK
11. SENSING UNIT:
AFTER AUTO LEVELING-2ND STAGE, ALL YELLOW LEVELING LIGHTS SHOULD BE OUT.
CHECK WITH A LEVEL TO SEE THAT THE VEHICLE IS LEVEL. IF IT IS, THE SENSING
UNIT IS PROPERLY ADJUSTED. [COMMENTS]
12. AUTOMATIC RETRACT (STORE):
A. THE "JACK STORAGE" INDICATOR LIGHT WILL START TO FLASH.
C. THE GREEN "TRAVEL" INDICATOR LIGHT SHOULD COME ON WHEN
THE RED WARNING LIGHTS ARE OUT.
B. THE RED WARNING LIGHTS SHOULD BE OUT WHEN THE JACKS ARE FULLY RETRACTED.
D. THE SYSTEM WILL AUTOMATICALLY SHUT DOWN SIX MINUTES AFTER ALL THE JACKS
ARE RETRACTED. ALL LIGHTS ON THE TOUCH PANEL SHOULD NOW BE OUT EXCEPT
THE "TRAVEL" LIGHT. CHECK THAT ALL JACKS ARE FULLY RETRACTED. COACHES
[COMMENTS]
10. AUTO LEVELING - 2ND STAGE:
PUSH THE "I" BUTTON AGAIN (2ND) TIME.
A. THE "HYDRAULIC OPERATION" INDICATOR LIGHT WILL START TO BLINK.
C. TWO JACKS AT A TIME WILL EXTEND CORRESPONDING TO ANY YELLOW LIGHT WHICH IS LIT.
THE PUMP WILL CYCLE ON AND OFF AS REQUIRED. THERE IS A SHORT DELAY BETWEEN
OPERATION OF THE JACKS. THIS SHOULD CONTINUE UNTIL ALL YELLOW LIGHTS ARE OUT OR
UNTIL ONE JACK HAS REACHED FULL STROKE.
D. THE PUMP WILL COME BACK ON. DURING THIS TIME ANY JACKS NOT ALREADY TOUCHING
THE GROUND WILL BE EXTENDED TO STABILIZE THE VEHICLE.
THE JACKS SHOULD LIFT THE VEHICLE AT LEAST 1/2 INCH BUT SHOULD NOT LIFT THE
VEHICLE MORE THAN 1 INCH.
E. THE "HYDRAULIC OPERATION" LIGHT WILL GO OUT. [COMMENTS]
THE IGNITION SWITCH MUST BE IN THE "ON" POSITION WITH THE ENGINE RUNNING.
PUSH THE "STORE" BUTTON ONE TIME.
WITH AIR SUSPENSION SHOULD RETURN TO RIDE HEIGHT A FEW MINUTES
AFTER JACKS ARE RETRACTED.
POSITION THE VEHICLE SO ONE OR MORE YELLOW LEVELING LIGHTS ARE ON.
PUSH THE "I" BUTTON ONCE TO TURN THE SYSTEM ON.
9. AUTO LEVELING - 1ST STAGE:
[COMMENTS]
B. AIR WILL DUMP FOR 25 SECONDS BEFORE STARTING TO LEVEL.
NOTE: IF THE "EXCESS SLOPE" LIGHT COMES ON, THE HYDRAULIC OPERATION LIGHT WILL TURN
OFF. THE "EXCESS SLOPE" LIGHT WILL STAY ON. PUSH THE "STORE" BUTTON AND ALLOW THE
JACKS TO RETRACT COMPLETELY.
NOTE: