manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Hydro Crunch
  6. •
  7. Lighting Equipment
  8. •
  9. Hydro Crunch KB630-DECMH-3K User manual

Hydro Crunch KB630-DECMH-3K User manual

630W 120-240V
User Manual
Digital Ballast
• If any part of the lamp is damaged, replace lamp immediately.
• Disconnect the unit from a power source before replacing lamps or
any other parts.
• When replacing lamps, make sure the lamp has had time to cool before
touching.
• Make sure power cord and lamp cord are connected securely to the unit.
• These products operate at very high temperatures. Keep away from children.
• Glass is required for reflectors using metal halide (MH) lamps for UL listing
to apply. Glass is not required for high pressure sodium (HPS) lamps to
be UL listed.
• Always use a three prong timer rated for 15 amps or more with light systems.
• Do not operate lamps that are a different wattage than the ballast specifies.
• Read all instructions completely before attempting to power on unit. Failure
to follow the warnings and instructions for use may result in serious injury or
death, for which the manufacturer and resellers expressly disclaim any and
all liability.
Operating Instructions:
2 Year Limited Warranty Service
1. Make sure the power supply cord and lamp end are properly connected.
2. Ensure the bulb is properly seated in the socket assembly. It should be
tight, but not stressed.
3. Always use a bulb centric to the highest output of the ballast (e.g.630W
bulb/630W ballast).
4. Confirm the ballast is not near any source of moisture or standing water.
5. Plug the power supply cord into an appropriate power supply.
6. After ignition, give your lamp a minimum of 30 seconds to reach full power.
7. Always allow the bulb to cool before re-striking the ballast; we recommend
15 minutes.
8. Ballast can be cleaned using a clean, dry towel. Should the ballast somehow
become wet, turn off main power supply and unplug the unit before attending
to it.
Remember, safety first! Although incredibly rewarding, indoor
growing can present dangerous situations. Never allow standing
water to be present, never hang a ballast from either the power
or lamp cord, and always make sure your equipment is fastened
safely and securely. Your ballast does not require any switches
or re-wiring to change voltage or bulb spectrum. Simply turn off
and unplug the unit and allow bulb to cool before changing cords
or bulbs, respectively.
If the product will not work after you have read the troubleshooting guide and
practiced the troubleshooting options, you are advised to return the light system
to the retailer you purchased it from. The dealer will be able to examine the light
and test its components. If they are not able to repair the light, they will return it
to us for examination and repair/replacement. Do not attempt to repair any
product on your own, as serious injury or death may result. If the retailer is not
able to help you and the light is still under manufacturer’s warranty, you may
contact us for technical support. In some cases, you will be issued an RMA#
(return merchandise authorization number) to return the unit for factory repair.
Complete the warranty form below and return the light with all original
packaging, your receipt of purchase, and a valid RMA# to the address below.
Please pack and ship the light in its original packaging. If it is damaged in
shipment we cannot be responsible and the warranty may be voided. Once
we receive RMA package, it will be repaired or replaced and shipped back
to you. Please note if an additional warranty was purchased and include
the extended warranty sales receipt with your return.
RETURN FORM
Include the following if returning:
√ Proof of purchase
√ This completed form
√ RMA# on the outside of the box
√ Extended warranty receipt
Return Merchandise Authorization Number (Required): ___________________
Contact Name: __________________________________________________
Address: _______________________________________________________
_______________________________________________________________
Phone #: _______________________________________________________
Email Address: __________________________________________________
Please give a brief description of your technical issue: ___________________
______________________________________________________________
______________________________________________________________
______________________________________________________________
SEND TO:
RMA Dept.
20651 Golden Spring Drive Suite 115
Walnut, CA 91789
714-516-8176
IMPORTANT!
The following pages contain important safety and operating instructions.
Please read and follow all instruction in this manual. Carefully read and
review all safety instructions, warnings and cautions contained in this
manual. Failure to read and follow these instructions, warnings and
cautionary statements may result in severe injury or death to persons
and pets or damage to personal property.
Do not dispose product or any other part of it as unsorted municipal waste –
insteadit shall be handed over to the applicable collection point for the recycling
of electrical and electronic equipment
Page 4 Page 5
All our ballasts are compatible with Safe
Grow Hydroponic Smart System.
1.Introduction
Thank you for purchasing our Digital Ballast. Please review the following
instructions to ensure you receive the best performance. Each ballast uses
a high temperature, resin-sealed component board for completely silent
operation without a fan. Each unit is burned-in at the factory for approximately
twelve hours to ensure maximum reliability.
Our Digital Ballast uses a mirco-processor similar to your home computer.
To ensure safe operation, it is programmed or a “soft-start” and does not
require an initial surge of power to light the lamp. This increases the lamp life
and allows the end user to start multiple ballasts at the same time without
tripping breakers. In case of auto-shut off, please disconnect from the power
supply, remove the faulty lamp or check for wiring problems, then restart
your ballast.
2.Controls, Connections and Indications
A.Digital ballast
B. Output plug
C.IEC connector for power cord
D . Power cord with NEMA 6-15 plug
NEMA 6-15
3. Product Information
3.1. Technical specifications
3.2. Main Dimension
3.3. HOT SPOT
Tcase max=75°C
3.4 Environment
The product is meant for use in climate rooms. The product may be used in
damp environments. The product may not be used in wet environments or
outdoors. The 630W Doubled Ended CMH Lamp functions optimal when the
ambient temperature is between -20 ~ 40° Celsius / -4 ~ 104° Fahrenheit.
4.Wiring Diagram
-Ballast Case must be Grounded
5.Protections
1.End of Lamp Life(EOL)Protection
2.Short circuit protection
3.Open circuit protection
4.Ignition failure protection
5.Thermal protection
6.Warning
Power surge, power outage, outage overloading may stress or damage the
lamp. As a safety feature, the Soft-Start technology also reduces ballast
damage caused by a bulb failure. In case of an unexpected shut-off, please
disconnect from the power supply, remove the faulty lamp, check for wiring
problems, then plug-in the ballast power cord.
7.Disclaimer
Any of the following circumstances will not be warrantied:
1. Product damaged due to incorrect installation of the product without
following the wiring diagram.
2. Damaged by improper use or submerging in water and not following the
manual instruction.
3. Install or use of the product without following local laws and regulations.
4. Damage due to maintenance or repair of the product by an unauthorized
technician.
5. Use in an environment that does not meet the provisions indicated in the
manual.
6. Damaged by mishandling, abnormal voltage, earthquake, flood, fire,
transportation accidents, etc.
IMPORTANT PRODUCT INFORMATION
READ IMMEDIATELY
SAFETY FIRST!
Failure to observe the following safety warnings may result in serious injury
or death. Use all products only as directed. Failure to observe these safety
warnings will result in a waiver of any and all liability on the part of its
manufacturer, and resellers, and will void all warranties to the extent
permitted by law.
WARNINGS AND INSTRUCTIONS
FOR USE:
• Disconnect power before re-lamping.
• When re-lamping, make sure lamp has time to cool before touching.
• Make sure power cord is connected properly.
• DO NOT hang ballast by power cord or lamp cord.
• DO NOT make contact with the interior of the socket while the power is on.
• DO NOT plug or unplug a lamp cord while the ballast is turned on.
• ALWAYS unplug the ballast from the power source before connecting or
disconnecting any lighting device to ballast, moving ballast, or otherwise
touching or handling ballast or its components.
• DO NOT use with generators. Warranty will be voided.
• NEVER stand beneath the ballast.
• NEVER put hands or any other objects in the interior of the ballast.
• DO NOT operate this or any lighting system in wet areas.
• NEVER get the ballast wet or allow it to come into contact with water or
any other liquids.
• NEVER drop, shake or jostle the ballast.
• NEVER attempt to insulate or otherwise cover the ballast, as it releases a
great deal of heat and may cause a fire or other damage. Ballasts should
always have plenty of room to breathe and good ventilation around them.
• DO NOT plug this system into a supply voltage other than what is
instructed on your fixture.
• DO NOT attempt open or rewire the components of the light system. It will
void the warranty and may cause serious injury or death.
• NEVER attempt to rewire or alter any internal or external mechanisms or
components on the ballast. This includes trying to cut and/or rewire
the cords.
Version 630W
3.5kg/7.72lb
75 °Celsius / 167 °Fahrenheit
-20 ~ 40 °Celsius / -4 ~ 104 °Fahrenheit
120V
5.78A
686W
>0.95
< 15%
50-60Hz
IEC C14
5 kV
≤50 Amps
Nema 6-15
240V
2.86A
270.5mmx181.5mmx102mm
Product weight
Dimensions (L*W*H)
Temperature case
Temperature ambient
Input voltage +/-10%
Input current at 100%
Input power at 100%
Power factor
Total Harmonic Distortion
Frequency
Power inlet
Ignition voltage:
Inrush current:
Plug type:
HOT SPOT
15A 125V~
E206144
C
BA
D
Page 1 Page 2 Page 3

This manual suits for next models

1

Popular Lighting Equipment manuals by other brands

LCG BEAMER 44 user manual

LCG

LCG BEAMER 44 user manual

BAYLED ORCA 3 RGBWA installation guide

BAYLED

BAYLED ORCA 3 RGBWA installation guide

Flash LIGHT BOX MOON 2 user manual

Flash

Flash LIGHT BOX MOON 2 user manual

ELCART 28/50050-00 instructions

ELCART

ELCART 28/50050-00 instructions

olympia electronics GR-315/15L manual

olympia electronics

olympia electronics GR-315/15L manual

UFO Apollo user guide

UFO

UFO Apollo user guide

Ultra Products ULT31352 brochure

Ultra Products

Ultra Products ULT31352 brochure

ADJ JOLT PANEL FX user manual

ADJ

ADJ JOLT PANEL FX user manual

Larson Electronics C1D2 instruction manual

Larson Electronics

Larson Electronics C1D2 instruction manual

involight PROWASH740Z user manual

involight

involight PROWASH740Z user manual

Soltech SATELIS installation manual

Soltech

Soltech SATELIS installation manual

XKGlow XKchrome 880 quick start guide

XKGlow

XKGlow XKchrome 880 quick start guide

ensto AVR66 Series operation instruction

ensto

ensto AVR66 Series operation instruction

V-TAC VT-521 installation manual

V-TAC

V-TAC VT-521 installation manual

Sygonix 2622935 operating instructions

Sygonix

Sygonix 2622935 operating instructions

Renkforce DL-PAR106 operating instructions

Renkforce

Renkforce DL-PAR106 operating instructions

BION TECHNOLOGIES linea xs inground Series user manual

BION TECHNOLOGIES

BION TECHNOLOGIES linea xs inground Series user manual

Honeywell Ova/OmniLED R quick start guide

Honeywell

Honeywell Ova/OmniLED R quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.