Hydro Tek H-8000C Series Manual

ISO 9001 Cered
OPERATION & MAINTENANCE MANUAL
H-8000C Series Flush Valve
(includes H8RFKC)
5055 Forsyth Commerce Rd, Ste 124, Orlando, FL 32807
Phone (800) 922-9883 | Fax (866) 670-5580
www.hydrotekintl.com

ISO 9001 Cered
8000 Series
U.S. Patent 6192530B1, 5699994
AC, Baery, or Solar Powered Sensor Operated Flush
The Hydrotek 8000 Series Automac Flush Valves are the most advanced,
electronic ushing system in the industry today. By incorporang our eld-
tested electronic circuitry and slow-closing solenoid valves, Hydrotek has
developed an innovave non-diaphragm, piston ushing mechanism that
will provide years of dependable and trouble-free service. The Hydrotek
AUTOFLUSH system is completely automac: there is no need to contact
any surface, no handle to push, and it ushes only when it is used. It
provides the ulmate sanitary protecon, the convenience of cleaner
restroom facilies, and the most ecient system in water conservaon.
• ADA Compliant. Meets all
barrier free codes
• Conserves water and energy
• Easily installed in new or retrot
applicaons
• Compevely priced for today’s
commercial market
• Promotes cleanliness & hygiene
• Proven Hydrotek crasmanship
and reliability
• ACCU-SENSE adjustable sensor eyes
• Standard manual mechanical override buon for
both urinals & water closets
• Standard brass/chrome-plated, all metal
construcon with other nishes available
• AC/DC powered - eld switchable
• Preset/adjustable ow rate and sensor distance
• Self-diagnosc electronics
• Standard vandal resistant stop valve (complete
units only)
• Superior piston ushing mechanism
• Field adjustable for le and right rough-in
• Baery replacement without water shut-o
• Operang pressures: 10-125 PSI
• Standard self-cleaning ltering system
• Switchable from/to urinal or closet
• 36 hour sennel ush
• Superior VSI silicone elastomer seals, unaected
by chlorine, chloromines or ammonia
• AC with DC backup models automacally switch to
baeries during a power outage
• Uses inexpensive AA baeries
• Baery service life: 400,000 on/o cycles (650,000
for the HB-8000SLE Series)
• Low baery indicator light (baery powered only)
• No outside power source required (baery
powered only)
• Can be installed by one tradesperson (baery
powered only)
Features:
H-8000C Series (AC)
Complete Units
HB-8000C Series (Baery)
Complete Units
HB8RFKC Series (Baery)
Complete Units
HB-8000SLE Series (Solar)
Complete Units

Hydrotek Autoush Valves
8000 Series
Meets A.S.S.E. Standard 1037-89
H-8000C (AC Powered) HB-8000C (Baery Powered)
HYDROTEK INTERNATIONAL, INC.
5055 Forsyth Commerce Rd., Ste 124
Orlando, FL 32807
800.922.9883 (Phone)
866.670.5580 (Fax)
www.hydrotekintl.com
The 8000 Series Flush Valves are available in:
H-8000C Series (AC Powered):
9H-8000C-A (Closet)
9H-8000C-B1 (Urinal)
9H-8000C-B2 (Urinal)
*Water conservaon, concealed and AC with DC
backup models available*
HB-8000C Series (Baery Powered):
9HB-8000C-A (Closet)
9HB-8000C-B1 (Urinal)
9HB-8000C-B2 (Urinal)
*Water conservaon and concealed models available*
HB-8000SLE Series (Solar Powered):
9HB-8000SLE-A (Closet)
9HB-8000SLE-B1 (Urinal)
9HB-8000SLE-B2 (Urinal)
*Water conservaon and retrot models available*
HB8RFKC Series Retrot Models (Baery Powered):
Sloan & Zurn Retrot
9HB8RFKC-C (Closet)
9HB8RFKC-U (Urinal)
Delany Retrot
9HB8RFKC-CD (Closet)
9HB8RFKC-UD (Urinal)
*Water conservaon models available*
PLUMBING SPECIFICATIONS:
Model Fixture Supply Line Top Spud Flow Rate
H/HB-8000C-A Closet 1” 1-1/2” 1.6 GPF
H/HB-8-128 Closet 1” 1-1/2” 1.28 GPF
H/HB-8000C-B1 Urinal 3/4” 3/4” 1.0 GPF
H/HB-8000C-B2 Urinal 1” 1-1/4” 1.0 GPF
HB8RFKC-C/U Cl. & Ur. N/A N/A 0.5-3.5 GPF
ELECTRICAL REQUIREMENTS:
• AC Powered Units:
– Solenoid valve and sensor: 6V DC
– Transformer: Input 120V AC, 60 Hz
Output 12V DC
• Baery Powered Units
– Solenoid valve and sensor: 6V DC
– Baery: (4) AA Alkaline Baeries
– Baery Service Life:
◦ 400,000 ushes, up to 6 years (Baery)
◦ 650,000 ushes, up to 10 years (Solar)
BASIC PACKAGE INCLUDES:
H-8000C
(-A, -B1, -B2)
HB-8000C
(-A, -B1, -B 2)
HB8RFKC
(-C, -U)
HB-8000SLE
(-A, -B1, -B2)
(1) Flush Valve 9 9 9 9
(1) Stop Valve 9 9 9
(1) Sweat Kit 9 9 9
(1) Flush Tube 9 9 9
(1) Spud Coupling 9 9 9
(1) Vacuum Breaker 9 9 9
(1) AC Adapter 9
(1) AC Input Tube 9
(4) AA Baers 9 9 9
OPTIONAL ACCESSORIES:
• HC-010 Mul-Unit Power Adapter (AC only) - 8 units
• HC-0104 Mul-Unit Power Adapter (AC only) - 4 units

H-8000C
AC Powered Flush Valve
Installaon Instrucons
ISO 9001 Cer ed
H-8000C
AC Powered Flush Valve
Installa on Instruc ons
Installa on Instruc ons:
1. Prior to installa on, “DRY TEST” the unit for proper
opera ons. Loosen the Set Screws (1) using the allen
wrench provided and remove the Top Cap (2) from the
valve body by pulling it straight up.
2. Connect the AC Power Adapter (3) to the Control
Module (4) and plug it in to a working power outlet.
Push the RESET bu on and watch the indicator lights
on the Control Module (4) for the following pa ern:
Red, (click), Green, Red, Red. This indicates that the
electronics are func oning properly. If the indicator
lights do not blink, contact the factory or your local
Hydrotek representa ve.
3. Reinstall the Top Cap (2) onto the valve body and
ghten the Set Screws (1). Install the Stop Valve (5) to
the supply line using a Hydrotek Sweat Kit (op onal).
4. Connect the valve body to the Stop Valve (5) using the
Slip Joint Nut (6).
5. A ach the Vacuum Breaker (7) and Tailpiece (9) to the
valve body using the Lock Nut (8). Secure the Tailpiece
(9) to the plumbing fi xture using the provided Spud
Coupling (10).
6. Turn the water on through the Stop Valve (5) and check
for leaks. Push and hold the Override Bu on (11) for
30 seconds and check the fi xture for over ow. Adjust
the water ow from the Stop Valve (5) for a smoother
ush.
7. TEST: Stand in front of the ush valve for 4 seconds,
then step away. The valve should ush automa cally. If
not, refer to the Troubleshoo ng Guide.
8. Flow rates are preadjusted from the factory. If minor
adjustments are needed, contact Hydrotek for further
details.
Parts:
1. Set Screws 7. Vacuum Breaker
2. Top Cap 8. Lock Nut
3. AC Power Adapter 9. Tailpiece
4. Control Module 10. Spud Coupling
5. Angle Stop 11. Override Bu on
6. Slip Joint Nut
HYDROTEK INTERNATIONAL, INC.
5055 Forsyth Commerce Rd., Ste 124
Orlando, FL 32807
800.922.9883 (Phone)
866.670.5580 (Fax)
www.hydrotekintl.com
6
1
2
3
4
5
11
7
8
9
10

H-8000C Series
Sensor Operated Flush Valve
Troubleshoong Guide
Normal Operaon: When power is connected, the ush valve will immediately perform diagnosc funcon.
You will hear a clicking sound and see lights ash. When the sensor is acvated, the light will ash once and
the valve will ush. The red indicator light will ash when the baeries are low.
Problem Possible Cause To Diagnose Remedy
Valve will not turn on:
Water not turned on Check water supply Turn water on
Power supply failure
No light, no clicking:
• Check baeries
• Check power adapter
Reinstall or replace baeries/
Replace power adapter
Electronic PCB / Sensor is
defecve
No light, no clicking:
• Reinsert baeries
• Reaach power adapter
Replace electronic PCB
Solenoid valve is clogged Solenoid is clicking but no water
is coming out Clean solenoid
Solenoid coil is defecve
Insert new baeries or reaach
power adapter. Light blinks but
no solenoid is clicking
Replace solenoid coil
Valve will not shut o:
The solenoid valve is normally closed. Turn o water and acvate the valve. If there is a clicking
sound, the solenoid valve is dirty. If there is no clicking sound, then check the solenoid valve. If
water is leaking through, the solenoid valve is dirty and needs to be serviced.
Other factors include:
• Sensor distance is too long
• Control module is defecve
• Manual override buon is scking
IMPORTANT: Periodic maintenance is required for smooth and trouble-free operaon of this ush valve.
For service and inquiry about available repair kits, please call Hydrotek Technical Support at (800) 922-9883.

H-8000C Series
Sensor Operated Flush Valve
Assembly Parts
No Descripon Part Number
1AC Power Adapter HCC-008Cv
2Control Module HCC-080B
3 Solenoid Coil HCC-098
4Sensor Eye and Cable HCC-080E
5Sweat Kit Assembly HC-084 (3/4”)
HC-084B (1”)
6Angle Stop - Complete Assembly HC-082A (3/4”)
HC-082B (1”)
7Angle Stop Repair Kit HC-082C
8Control Disc Assembly HCC-102
9Manual Override Buon Assembly HC-089
10 Vacuum Breaker Repair Kit HC-086
11 Flush Tube
HC-086A (1-1/2”)
HC-086B (3/4”)
HC-086C (1-1/4”)
12 Top Spud Assembly
HC-093A (3/4”)
HC-093B (1-1/4”)
HC-093C (1-1/2”)
RSolenoid Valve Repair Kit HCC-106
Please visit our website, www.hydrotekintl.com, for
our most current Products Pricing Sheet.
2
4
3
5
6
7
8
9
10
11
12
R
1

H-8000C Series
Sensor Operated Flush Valve
Control Module
1 2 3
4
56789
LEGEND
1. DC Input Pin Receptor
2. Dip Switches
3. Reset Buon
4. Indicator Lights
5. Solenoid Pin Receptor
6. Control Cable (Sensor Eye) Pin Receptor
7. Sensor Distance Adjustment Dial
8. AC Input Pin Receptor
9. DC Input Pin Receptor

H-8000C Series
Sensor Operated Flush Valve
Control Module Sengs
Flow rate and sensor arming me can be adjusted via the dip switches located on the Control Module.
Gallons
Per
Flush Sw 1 Sw 2 Sw 3 Sw 4
Urinal
0.125* ON ON OFF ON
0.5 ON ON ON ON
1.0 ON ON ON OFF
Closet 1.28 ON ON OFF OFF
1.6 ON OFF ON ON
Flushing Volume
Flush Valves are preset to 1.0 GPF for urinal and 1.6 GPF for closet
Sw 5 Sw 6 Sw 7 Sw 8 Arming Time
Urinal Standard OFF OFF OFF ON 3 seconds
Oponal ON OFF OFF OFF 1.5 seconds
Sensor Arming Time
Sensing Time Required to Flush
Sw 5 Sw 6 Sw 7 Sw 8 Arming Time
Closet Standard ON OFF OFF OFF 4 seconds
Oponal OFF OFF OFF OFF 8 seconds
NOTE: PUSH THE RESET BUTTON ON THE CONTROL MODULE AFTER
ANY ADJUSTMENTS TO THE DIP SWITCHES.
Sensor Distance Adjustment
Clockwise Increase sensing distance
Counter-Clockwise Decrease sensing distance
*0.125 ow rate seng only available if ordered that way from the factory
For alternate ow rates not listed, please contact Hydrotek direct

Page 1
D.2162
Acorn Engineering Company • 15125 Proctor Avenue • P.O. Box 3527 • City of Industry, CA 91744-0527 U.S.A.
Tel: (800) 488-8999 • (626) 336-4561 • Fax: (626) 961-2200 • www.acorneng.com • E-mail: [email protected]
Fixture May Show Some Available Options
Please visit www.acorneng.com for most current specifications.
®
Dura-Ware 2162 Series
Washout Urinal
Exposed Mounting Screws are furnished. No concealed wall fasteners or anchor shields are
furnished.
Provide and install Acorn Dura-Ware Washout Urinal (specify model number and options). Urinal
shall be back wall washdown type. Fixture shall be fabricated from 14 gage, type 304 stainless
steel and shall have coved corners to facilitate cleaning. Urinal shall meet ASME A112.19.3 and
CSA B45.4 requirements. All welds shall be continuous and exterior surfaces shall have a satin
finish. P-trap shall be fully enclosed. Fixture shall be furnished with exposed mounting screws.
Urinal is washout type with back wall washdown manufactured to ASME A112.19.3 and CSA
B45.4 requirements. Flushing inlet connection is 3/4" NPT male. Bottom of urinal is sloped to a
high capacity stainless steel beehive dome strainer. Strainer is secured with tamper-resistant
screws. P-trap has a minimum of 2" seal.
Washout Urinal
Fixture is arranged to be installed on finished wall and serviced from the front side. Fixture is
fabricated from 14 gage, type 304 stainless steel and is seamless welded construction. Exterior
has a satin finish. Interior has a matte finish. Fixture has a back wall washdown, and is
optionally available with a continuous flushing rim that washes all four walls. Corners are coved
to facilitate cleaning. P-trap is fully enclosed. Back of fixture is sound-deadened with fire-
resistant material.
GUIDE SPECIFICATION
2162-W-1-FV-28982162-T-1-FV
Revised: 08/21/18

Page 2
Selection Summary
Model No. & Option___________________________
Quantity____________________________________
Approved for Manufacturing
Company__________________Title______________
Signature_________________ Date______________
Important: Installation instructions and current rough-in are furnished with each fixture. Do not rough in without certified dimensions.
Dimensions are subject to manufacturer’s tolerance of plus or minus 1/4" and change without notice. Acorn assumes no responsibility for use of void or superseded data. © Copyright 2007 Acorn Engineering Company
PRODUCT OPTIONS
o -CFR Continuous Flushing Rim
o -EG Enviro-Glaze Color, Specify: ______________
o -FVT Flush Valve Thru Wall Connection
q -TF Transformer, 120VAC to 24VAC (-MVCFV Option)
o -WA1 Waste Adapter to 2" NCT Female
o -WA2 Waste Adapter to 2" NPT Male
o -WA3 Waste Adapter to 2" NPT Female
o -WA4 Waste Adapter to 2" No-Hub
FLUSH VALVE OPTIONS (Must Specify)
Refer to Acorn Dura-Ware Supplementary for Box Cover(s)
and Access Panel(s)
o -FV Flush Valve, Mechanical
o -FVBO Flush Valve by Others
o -FVH Flush Valve, Hydraulic (N/A for Top Supply)
o -FVL Flush Valve, ADA Lever Handle (Concealed F.V.)
o -MVCFV Time-Trol Flush Valve (N/A for Top Supply)
D.2162
®
Dura-Ware 2162: Washout Urinal
WALL THICKNESS AND TYPE (Must Specify)
Thickness: ________ Type: o Concrete o Block o Steel
BASE MODEL NUMBER
o 2162 Washout Urinal
MODEL NUMBER AND OPTIONS SELECTION
SUPPLY (Must Specify)
o -T Top (Exposed)
o -W Wall (Concealed)
FIXTURE MOUNTING AND WASTE
o -1 Off-Floor, Wall Outlet
FLUSH VALVE GPF’s (Must Specify)
o -1.0 GPF
o -1.5 GPF
Please visit www.acorneng.com
for most current specifications.
Acorn Engineering Company • 15125 Proctor Avenue • P.O. Box 3527 • City of Industry, CA 91744-0527 U.S.A.
Tel: (800) 488-8999 • (626) 336-4561 • Fax: (626) 961-2200 • www.acorneng.com • E-mail: [email protected]
3. Urinal Waste Outlet.
5. Wall Mounting Anchors (By Others).
4. Beehive Strainer.
2. Optional -FV Flush Valve - Top Supply.
1. Optional -FV Flush Valve - Wall Supply.
NOTES: 2162-W-1
2162-T-1
5
3
241
24"
(610)
RECOMMENDED
6"
(152)
14"
(356)
12"
(305)
14"
(356)
12"
(305)
3
3
Revised: 08/21/18
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov

Page 1
D.2120
Acorn Engineering Company • 15125 Proctor Avenue • P.O. Box 3527 • City of Industry, CA 91744-0527 U.S.A.
Tel: (800) 488-8999 • (626) 336-4561 • Fax: (626) 961-2200 • www.acorneng.com • E-mail: [email protected]
Fixture May Show Some Available Options
Please visit www.acorneng.com for most current specifications.
®
Dura-Ware 2120 Series
Siphon Jet Toilet - On Floor - Floor Outlet
Flush Valve supply is additionally available for exposed or concealed flush valve styles in 1.28
GPF, 1.6 GPF or 3.5 GPF with 1-1/2” NPT connection.
Siphon Jet Toilet - On Floor - Floor Outlet
GUIDE SPECIFICATION
Provide and install Acorn Dura-Ware Siphon Jet Toilet (specify model number and options).
Fixture shall be fabricated from 16 gage, type 304 stainless steel. Construction shall be
seamless welded and exposed surfaces shall have a satin finish with an integral contoured toilet
seat. Toilet shall be concealed siphon jet type with an elongated bowl and a self-draining
flushing rim. Toilet shall be ASME A112.19.3-2008 and CSA B45.4-2008 compliant. Toilet
requires a minimum of 25 PSI flow pressure and uses a minimum water consumption of 1.28
GPF. Toilet trap shall have a minimum 3-1/2" seal that shall pass a 2-1/8" diameter ball and be
fully enclosed. Toilet waste outlet shall be 7-1/2" Gasketed Waste with 6" mounting centers.
Connecting hardware provided by installer.
Fixture is arranged to be installed on finished wall from the front side. It is fabricated from 16
gage, type 304 stainless steel and is seamless welded construction. Exterior has a satin finish
with an integral contoured seat. The inside of the toilet bowl also has a satin finish. Wall flange
is reinforced for maximum strength.
Toilet is Siphon Jet type with elongated bowl manufactured to comply with ASME A112.19.3-
2008 and CSA B45.4-2008 standards. Toilet requires a minimum of 25 PSI flow pressure and
uses a minimum water consumption of 1.28 GPF. Trap has a minimum 3-1/2" seal, will pass a
2-1/8" ball and is fully enclosed. Toilet has a 1-1/2” NPT flushing inlet connection and a 7-1/2"
gasketed waste with 6" mounting centers. Connecting hardware provided by installer.
2120-W-3-CN
Revised: 03/15/19

Page 2
Selection Summary
Model No. & Option___________________________
Quantity____________________________________
Approved for Manufacturing
Company__________________Title______________
Signature_________________ Date______________
Important: Installation instructions and current rough-in are furnished with each fixture. Do not rough in without certified dimensions.
Dimensions are subject to manufacturer’s tolerance of plus or minus 1/4" and change without notice. Acorn assumes no responsibility for use of void or superseded data. © Copyright 2009 Acorn Engineering Company
D.2120
®
Dura-Ware : 2120 Siphon Jet Toilet - On Floor - Floor Outlet
Acorn Engineering Company • 15125 Proctor Avenue • P.O. Box 3527 • City of Industry, CA 91744-0527 U.S.A.
Tel: (800) 488-8999 • (626) 336-4561 • Fax: (626) 961-2200 • www.acorneng.com • E-mail: [email protected]
Please visit for most current specifications.www.acorneng.com
FLUSH VALVE OPTIONS (Must Specify)
*REFER TO ACORN DURA-WARE ACCESSORIES FOR FLUSH
VALVE COVER #2802, BOX #2803-1 AND PANEL #2898*
o -FV Flush Valve, Mechanical (N/A for ADA)
o -FVBO Flush Valve by Other
o -FVH Flush Valve, Hydraulic (N/A for Top Supply)
o -FVL Flush Valve, ADA Lever Handle
o -MVCFV Time-Trol Flush Valve (N/A for Top Supply)
FIXTURE MOUNTING AND WASTE (Must Specify)
-3 On-Floor, Floor Outleto
MODEL NUMBER AND OPTIONS SELECTION:
SUPPLY (Must Specify)
-T Top (Exposed)o
-W Wall (Concealed)o
BASE MODEL NUMBER
2120 Siphon Jet Toiletq
FLUSH VALVE GPFs (Must Specify)
o -1.28 GPF (HET)
o -1.6 GPF (Not Available in California)
o -3.5 GPF (Not Available in California)
WALL THICKNESS AND TYPE (Must Specify)
Thickness: ___________ Type: o Concrete o Block o Steel
3
3
23
4"
(70)
15"
(381)
29"
(737)
14"
(356)
9"
(229)
183
4"
(476)
41
4"
(108)
41
4"
(108)
2
1
345
2120-W-32120-T-3
5
NOTES:
1. Optional -FV Flush Valve For
Concealed -W Wall Supply
2. Optional -FV Flush Valve For
Exposed -T Top Supply
3. Toilet Recessed Gasket Waste
Outlet
4. Floor Fasteners
5. Wall Mounting Hardware,
By Others
Get Started www.mgispecbuilder.comConfigure products and create specs with ease.
TOILET SEAT OPTIONS
o -HPS High Polish Integral Seat
o -HS-OFLC Hinged Seat, Open Front Less Cover
o -HS-OFWC Hinged Seat w/ Cover
o -PFS Punched for Seat by Others
TOILET OPTIONS
o-FT Flood-Trol (N/A with Top Supply)
o-FTA Flood-Trol Auto-Reset (N/A with Top Supply)
o -FTE Flood-Trol Electronic
o-FVT Flush Thru Wall Connector
o-TSC Toilet Shipping Cover
PRODUCT OPTIONS
o-ADA 18” Integral Seat Height
o -BCN Blind Cap Nuts (4)
o -BL Bedpan Lugs
o -CN Cap Nuts (4)
o-EG Enviro-Glaze Color Specify:__________
Toilet Interior & Exterior
o -EGE Enviro-Glaze Color Specify:__________
Toilet Exterior Only
o -FG 14 Gage Housing
o-TF Transformer, 120VAC to 24VAC (-MVCFV option)
o-VAC AcornVac System
Revised: 03/15/19
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov

Fail-Safe
SPECIFICATION FEATURES
Fasteners
Captive, stainless steel
tamperproof, T20 TORX ®-head
screws prevent unauthorized
access.
Housing
Die-formed 16 ga. Steel (FVS4P),
18 ga. Steel (FVS4M) with welded
and ground ends. Stainless steel
housing available.
Finish
Matte white electrostatically
applied, white powder coat finish.
Gloss white and anti-microbial
white painted finish available.
Gasket
Concealed, polyurethane end
gaskets inhibit the entrance of
environmental contaminants.
Lens
Nominal 0.125”, UV stabilized,
clear Pattern 12, impact-resistant,
prismatic polycarbonate refractor
for high efficiency, low surface
brightness and maximum strength.
Opal smooth available. .187”
thick clear Pattern 12 prismatic
polycarbonate available.
Lifetime Lens Warranty
LEDs
Available with 3000K, 3500K,4000K,
5000K with minimum of 80CRI.
Projected life is 50,000 hours at
70% lumen maintenance.
Lens Retention
The FVS4P double wall lens
channel captivates lens to prevent
unauthorized fixture penetration.
Screws along each side to ensure
maximum lens captivation. FVS4M
incorporates (2) tamper resistant
screws, one on each endcap.
Transformer/Driver
Electronic driver 120V-277V, 0-10V,
dimming standard.
Compliance
UL listed for damp location.
Wet location listed under covered
ceiling optional. (FVS4P only).
Warranty
5 Year warranty on LED’s and
electrical. Lifetime warranty if
fixture found to be inoperative due
to physical abuse for duration of
the installation.
FVS4
FVS4W
LD4 LED
4" Wide
2',3',4',8' Length
Polycarbonate Lens
Vandal Resistant
Ceiling/Wall
PS519165EN
June 14, 2019 2:11 PM
Designed with asthetics as a high priority, the tasteful FVS4 combines
style with strength. Ideally suited for high abuse areas, Fail-Safe's
FVS4 is offered as ceiling- or wall-mounted, to provide general ambient
illumination. Designed for use in public access areas where vandalism
may occur and for areas that must maintain a clean, well-illuminated
appearance.
Ideal for schools, dormitories, hallways, locker rooms, shower facilities,
stairwells, restrooms, and storage facilities.
DESCRIPTION
ENERGY DATA
For Energy Management related
technical data to support the
performance of this fixture series,
refer to the ordering information for
input wattage.
WALL MOUNT
FVS4W
Construction
Housing
Listing
FVS4MFVS4P
18GA Steel
16GA Steel
ETL
Listed Damp
Location
ETL
Damp,
Wet Optional
Set Screws
on Endcaps
Screws along
fixture edge
Length
FVS4P
# Screws
each side
2’
3’
4’
8’
2
2
3
5
FVS4P
PREMIUM MODERA
TE
4.00 in
102mm
3.75 in
95mm
FVS4M
CEILING or WALL MOUNT
FVS4
Catalog #
Project
Comments
Prepared by
Type
Date

Specifications and
dimensions subject to
change without notice.
Eaton
1121 Highway 74 South
Peachtree City, GA 30269
P: 770-486-4800
www.eaton.com/lighting
FVS4=High Abuse
4” Wide Surface
Luminaire
=High Abuse
4” Wide Surface
Wall Mount
Luminaire
120 =120 Volt
277 =277 Volt
SAMPLE NUMBERS: FVS4WM-8-LD4-2STD-35-UNV-OPL-EDC1-EL7W
Color
Temp Voltage
FVS4
Product
Family
EL7W=7 watt EM Pack
SHP=Stainless steel,
painted housing
SHB=Stainless steel,
brushed housing
OS1=Internal Occupancy Sensor
(behind lens), connected to one
LED module.
Specify 120 or 277 voltage.
OS2=Internal Occupancy Sensor
(behind lens), connected to two
LED modules.
Specify 120 or 277 voltage.
WL=Wet location, listed under
covered ceiling (FVS4P only)
Options
Driver
EL14W=14 watt EM Pack
FVS4P-4-LD4-2STD-30-120-P187-EDC1-OS1-WL
Notes:
UNV =120-277 Volt
Length LED
2=2’ length
3=3’ length
4=4’ length
8=8’ length
EDC1=Electronic driver,
Non-Dimming, 1 circuit
EDC2=Electronic driver,
Non-Dimming, 2 circuits
EDD1=Electronic driver,
Dimming 10%, 1 circuit
EDD2=Electronic driver,
Dimming 10%, 2 circuits
ED1D1=Electronic driver,
Dimming 1%, 1 circuit
ED1D2=Electronic driver,
Dimming 1%, 2 circuits
No. of
LEDs
1=1 row LED module
in X-section
2=2 rows LED module
in X-section
Illumination
Level Lens
P125= .125” Clear polycarbonate
prismatic lens
P187= .187” Clear polycarbonate
prismatic lens
OPL= .125” Polycarbonate
smooth opal lens
30=3000K
35=3500K
40=4000K
50=5000K
LD4 =Linear LED,
Version 4
LO=Low
STD=Standard
HI=High
1 Up to 1HI only with Emergency Battery Pack. 1LO, 1STD, 1HI available
with EL7W and EL14W. 2 LED cross-section not available.
2 EL7W not available in 2ft length. EL14W not available in 2ft or 3ft length.
3 FVSP Only.
4 2HI with 2 circuits not available in 2ft length.
5 OS1 and OS2 require 120 or 277 to be specified in the ordering logic.
6 2’ length fixture with 2 circuits and OS1 or OS2 is not available.
1, 2
1, 2
M=Moderate
P=Premium
3
4, 6
1, 4 5,
6
5,
6
LD4
FVS4W
ORDERING INFORMATION
22”
2.25”
2.25”
2’,3’,4’
8’
- Mounting Dimensions
- Mounting Dimensions
23.5” (2ft)
36.0” (3ft)
46.5” (4ft)
90.1”
16”
(3) .875” Knockouts
(4) .375” Mounting Holes
19.5” (2ft)
32.0” (3ft)
36.0” (4ft)
(5) .875”
Knockouts
(8) .375”
Mounting Holes
FVS4 LED
MOUNTING DIMENSIONS
PS519165EN
June 14, 2019 2:11 PM

Specifications and
dimensions subject to
change without notice.
Eaton
1121 Highway 74 South
Peachtree City, GA 30269
P: 770-486-4800
www.eaton.com/lighting
NOMINAL INPUT WATTS
FVS4 LED
PS519165EN
June 14, 2019 2:11 PM
LENGTH # Modules in
Cross-Section
Illumination
Level
Nominal
Input
Watts
Color
Temp
LENS
P125
Nominal
Delivered
Lumens
LENS
P187
Nominal
Delivered
Lumens
LENS
OPL
Nominal
Delivered
Lumens
2’
1
LO 12.3
30
35
40
50
1266
1290
1316
1434
1230
1254
1279
1394
849
865
882
961
1STD
16.9
30
35
40
50
1723
1756
1791
1952
1675
1707
1741
1897
11 5 5
11 7 7
1201
1309
1 HI
22.2
30
35
40
50
2125
2166
2209
2408
2065
2105
2147
2340
1425
1452
1481
1614
2
LO 24.1
30
35
40
50
2614
2664
2717
2962
2540
2588
2640
2878
1648
1679
1713
1867
2STD
33.9
30
35
40
50
3475
3541
3612
3937
3376
3440
3509
3825
2190
2232
2277
2482
2 HI
44.8
30
35
40
50
4266
4347
4434
4833
4145
4223
4308
4696
2689
2740
2795
3047
3’
1
LO 21.3
30
35
40
50
2384
2429
2478
2701
2254
2296
2343
2553
1545
1574
1606
1751
1STD
28.5
30
35
40
50
3067
3125
3188
3475
2899
2954
3014
3285
1988
2025
2066
2252
1 HI
36.3
30
35
40
50
3699
3770
3845
4191
3497
3564
3635
3962
2397
2442
2492
2716
2
LO 56.8
30
35
40
50
5909
6022
6142
6695
5575
5682
5795
6317
3567
3635
3708
4042
2STD
64.0
30
35
40
50
6545
6671
6804
7416
6175
6294
6420
6997
3951
4027
4107
4477
2 HI
71.7
30
35
40
50
7136
7273
7418
8086
6733
6862
6999
7629
4308
4390
4478
4881
4’
1
LO 23.6
30
35
40
50
2594
2643
2696
2939
2515
2563
2614
2850
1707
1739
1774
1934
1STD
33.6
30
35
40
50
3476
3542
3613
3938
3370
3434
3503
3818
2287
2330
2377
2591
1 HI
44.5
30
35
40
50
4274
4356
4443
4843
4144
4224
4308
4696
2812
2866
2923
3186
2
LO 57.4
30
35
40
50
6015
6130
6253
6816
5848
5960
6080
6627
3756
3828
3905
4256
2STD
67.5
30
35
40
50
6853
6984
7124
7765
6663
6791
6927
7550
4279
4361
4448
4849
2 HI
89.3
30
35
40
50
8335
8494
8664
9444
8104
8259
8424
9182
5205
5304
5410
5897
use this light fixture
Other manuals for H-8000C Series
1
This manual suits for next models
3
Table of contents
Other Hydro Tek Control Unit manuals
Popular Control Unit manuals by other brands

Spod
Spod SE Installation instructions manual

Valcom
Valcom V-2001 instruction manual

KMC Controls
KMC Controls HPO-9001 installation guide

System Sensor
System Sensor EM-1SRI Installation and maintenance instructions

pizzato
pizzato CS MP307M0 quick start guide

tams elektronik
tams elektronik LED Control Basic manual