Hydrofarm AADHC180P User manual

INSTRUCTION MANUAL
DEHUMIDIFIER AADHC180P

2 www.hydrofarm.com
WARNINGS
Please follow the below safety guidelines
when using the dehumidier:
• Unplug the power supply when cleaning
or storing the unit.
• Do not put into water or operate near a
water source.
• Do not place the unit near the heat
equipment or Inammable dangerous
goods
• Keep ngers and other objects away from
air inlets and outlets.
• Do not stand on the unit.
• Do not cover the louvered panes on the
machine or it will overheat.
• Install the drainpipe facing downward so
condensaon will ow out of the pipe.
• If the power cable is damaged, please
contact a licensed electrician for
replacement or repair.
FEATURES
• Large capacity
• Moveable and easy to store
• Built-in auto defrost system to protect
key working components
• Adjustable humidity
• Timed operaon
• Quiet running
• Energy-saving design
SPECIFICATIONS
Model# .................................. AADHC180P
Rated capacity ...................... 180Pints/ Day
Power supply ........................ 120V / 60Hz
Rated input current .............. 11.3A
Rated input power ................ 1350W
Max condenser pressure ...... 3.6MPa
Max evaporator pressure ..... 1.2MPa
Freon type & capacity .......... R410a / 750g
Grade of waterproof ............. IP-X1
Weight ................................... 116 lbs
Operang ambient
temperature ........................ 41° F – 95° F
Test condions ...................... 86° F, RH80%
INSTRUCTION MANUAL
Thank you for selecng Acve Air dehumidiers. This manual details the
proper use and maintenance of these dehumidiers. Please take a few
minutes to read this manual, and please keep it for further reference.
PLEASE KEEP THIS MANUAL FOR FUTURE REFERENCE!

3
www.hydrofarm.com
INSTRUCTION MANUAL
PRODUCT DRAWINGS
FRONT
BACK
Control Panel
Air-In Louver
Front Panel
Drainage Pipe
Power
Cord
Side
Handle
Compressor
Heat Vent
Back Handle
Air-Out Louver
Side Handle
FRONT
BACK

4 www.hydrofarm.com
DRAINAGE INSTALLATION
Install the included drain pipe to the draining
nozzle on the machine and direct the pipe to
the desired area before operate the machine.
If in need to replace or extend the drainage
pipe, use ID Ø16mm, or 5/8in, piping.
WARNING: Do not block the drainage hose.
The end of the drainage pipe should not be
higher than the outlet hole. If the drainage
pipe end is higher than the outlet hole, water
will not drain properly and could damage
components of the unit.
MACHINE SETUP AND
OPERATION
KEY FUNCTIONS
POWER – Turns the unit on and o.
CONTINUOUS OPERATION – When pressed,
the unit will operate connuously.
TIMER/MODE – The unit has 5 modes:
Humidity, Current Time, Timed Operaon On,
Timed Operaon O, and Exit. Every me you
press the Timer/Mode key it cycles to the next
mode.
“+” KEY – When in the “SET” mode, every me
you press the “+” key, it will raise the humidity
by 1%. If you hold the key down, it will add
humidity more quickly. When in any of the me
modes, the “+” key adds hours. These keys are
used to set “CURRENT” me, “TIMING ON”,
and “TIMING OFF.”
“–“ KEY – When in the “SET” mode, every me
you press the “–” key, it will lower the humidity
by 1%. If you hold the key down, it will lower
humidity more quickly. When in any of the
me modes, the “–” key adds minutes. These
keys are used to set “CURRENT” me, “TIMING
ON”, and “TIMING OFF.”
HUMIDITY AND TIMER SETUP
When the machine is powered on for the
rst me there will be an audible buzz sound.
Please note that the machine has a default
seng for humidity.
1. Press the POWER buon to start the
machine. The screen will display “Run” and
“Current,” the present humidity.
Run
INSTRUCTION MANUAL
Drainage
Nozzle Drainage Pipe

5
www.hydrofarm.com
INSTRUCTION MANUAL
2. To set the desired humidity, press the
TIMER/MODE buon. The screen shows
“Set” and the machine enters into the set
mode. When in the set mode, you can
increase or decrease the humidity from
the default seng to your desired level by
using the “+” or “–” buons.
Run Set
ATTENTION: The machine default humidity
seng may be lower or higher than the
current ambient humidity when the machine
is powered on for the rst me. If the default
humidity is higher than the current humidity,
aer the machine is powered on, although
the fan will operate, the dehumidify funcon
will not operate. You are required to reset
the humidity to your desired level in order to
ensure the machine will operate properly.
3. To set the current me, press TIMER/
MODE again to see the present me.
You can change the me by using the “+”
buon to change hours and “–” buon to
change minutes.
Run Set
ATTENTION: The me format is in 24 hours and
the default me is set at 12:00. You can choose
to skip the current me seng by pressing the
TIMER/MODE buon to cycle to exit. However,
if the machine operates by the default current
me, the Timing On and Timing O funcon,
if set, will operate according to the default
current me, but not the real current me. You
are highly recommended to set the current
me.
4. To set for med operaon, press TIMER/
MODE a third me and “Timing on” will
display. Use the “+” buon to change hour
and the “–” buon to change minutes. The
mer is in 24-hour format.
Run Set
5. Aer you press TIMER/MODE a fourth
me, “Timing o” will display. Use the “+”
buon to change hour and the “–” buon
to change minutes.
Run Set
TIP: You can choose to skip the Timing on and
Timing o seng by pressing the TIMER/
MODE buon to exit. If so, you must manually
power the machine on or o each me by
pressing the POWER buon.
6. Press TIMER/MODE a h me to exit the
seng mode.
Run
OPERATIONS
Non-med dehumidifying operaon to
the desired humidity level
When the mer is not set, the unit
dehumidies toward the humidity set point
and automacally goes to the standby mode
when the set point is achieved. Aer the
ambient humidity increases more than 3%, the
dehumidifying funcon operates again. The
machine will connue working in this paern
unl it is manually powered o.
Due to the 3-minute on/o delay design to
protect the working components (see On/
O Delay, page 6), the humidity reading
may go up more than 3% while the machine
remains in the standby mode since it is within
the 3-minute delay protecon period. This
usually happens in the condion that the
ambient humidity is high. It is not a machine
malfuncon.

6 www.hydrofarm.com
Timed dehumidifying operaon to the
desired humidity level
When the mer is set, the machine will operate
according to the humidity set point (see
page 5, step 2), only aer the Timing On me
and before the Timing O me. Before the
Timing On me and aer the Timing O me,
the machine is in standby mode. Unless the
power supply cord is unplugged, the machine
remembers all set points in the standby mode
and will automacally operate according to the
mer setup every day.
You can manually override the mer funcon
to start or stop the dehumidifying funcon
by pressing the POWER buon. The machine
resumes to the mer mode in the next 24-hour
cycle.
Automac Defrost
The unit will automacally go into defrost
mode when frost forms on the evaporator coil.
The screen shows “Defrost.” Aer 15 minutes
of defrost me the unit will resume operaon.
When in the defrost mode, the unit does not
dehumidify.
Connuously dehumidify operaon
When the machine is in connuous operaon,
the desired humidity set point is sll
remembered but is deacvated. The machine
will connuously dehumidify, no maer what
the humidity set point is, unl it is manually
powered o or med o.
1. Press the CONTINUOUS OPERATION buon
to enter the connuous operaon mode.
The screen will show “Connuous.”
Run
2. Press the CONTINUOUS OPERATION buon
again to deacvate connuous operaon.
The machine goes back to the mode of
operang according to the humidity set
point.
When there is a frost buildup, the machine
will be forced to stop dehumidifying and start
defrosng automacally. The screen shows
the machine in “Defrost” process under
“Connuous” mode. Aer the defrost funcon
ends, “Defrost” disappears from the screen
while “Connuous” sll shows.
Automac Restart
In the event of a power failure, the machine
will remember what the humidity set point was
and whether the unit was in operang mode
before the power failure.
When power is restored, if the unit was
operang before the power failure, it
automacally restarts to operate according to
the humidity set point in the non-med mode.
If the unit was not operang before the power
failure, the unit remains in non-working
condion.
Current Time, Timing On, Timing O and
Connuous Operaon set points will not be
remembered when power failure occurs. They
must be reset when the power is restored.
The Automac Restart feature allows the unit
to be used with controllers and mers.
On/O Delay
If the system is turned o aer running and
you wish to turn it on again, there is a 3-minute
delay before restart as protecon to the
working components of the unit.
INSTRUCTION MANUAL

7
www.hydrofarm.com
INSTRUCTION MANUAL
MAINTENANCE
1. Clean the machine with a so wet cloth.
2. Pull out the louver on the front panel to
gain access to the lter.
3. Remove the lter mesh out of the unit.
4. Use a clean rag to absorb the surface dust
on the lter mesh. If the lter is extremely
dirty, use tap water to ush the lter. Fully
dry the lter before pung it back into the
air inlet fence. A clean lter will increase
the machine’s capacity.
MACHINE STORAGE
If you don’t use the unit for an extended period
of me, please store it per the following steps.
1. Clean the lter mesh.
ATTENTION: The evaporator inside the
machine has to be dried out before the unit
is packed to avoid component damage and
molds. Unplug the unit and place it in a dry
open area for a few days to dry it out.
TIP: Another way to dry the unit is to set
the humidity point higher than the
ambient humidity to force the fan to
dry the evaporator for 30 minutes. The
dehumidifying funcon will not work and
the fan can accelerate the drying process.
2. Collect the power cord, bunch it, and hang
it in the power cord pocket at the back of
unit.
3. Store the unit in a clean, dry environment.

8 www.hydrofarm.com
AADHC180P_instrux_12.2014
www.hydrofarm.com
TROUBLE SHOOTING
Please try the following soluons before requesng aer-sale service.
TROUBLE CAUSE SOLUTION
Machine does not run Unit is not plugged in. Plug in the unit.
Ambient temperature is under 5
degrees or above 35 degrees.
To protect the machine, use it only when ambient
temperature is between 5 and 35 degrees.
The humidity sensor is loose, wet or
defective; the screen will show“E5”.
Check the sensor connection. Use a blower to dry the
humidity sensor behind the front cover. If the machine still
does not run, contact your retailer to replace the sensor.
The temperature sensor is loose or
defective; the screen will show“E6”.
Check the sensor connection. Contact your retailer to replace
the sensor.
Machine runs but does
not dehumidify
The humidity set point is higher
than the ambient humidity.
Reset the humidity to a lower set point, or power o the
machine if the desired humidity level has been reached.
Reduced dehumidier
capacity
Filter mesh is jammed. Clean the lter mesh according to manual.
Air-in and/or Air-out louvers are
jammed.
Clear the blockage from Air-in and/or Air-out louvers.
No air inlet Filter mesh or Air-in louver is
jammed.
Clean lter according to instructions or clean the louver
blockage.
Loud Operation Machine is situated on an incline or
decline slope.
Move to a level location.
Filter mesh is jammed. Clean lter mesh according to instructions.
WARRANTY
Hydrofarm warrants the dehumidier to be free from defects in materials and workmanship. The
warranty term is one year beginning on the date of purchase. Misuse, abuse, or failure to follow
instrucons is not covered under this warranty. Hydrofarm will, at our discreon, repair or replace
the unit covered under this warranty if it is returned to the original place of purchase. To request
warranty service, please return the dehumidier, with original sales receipt and packaging, to your
place of purchase. The purchase date is based on your original sales receipt.