Error-FLC
FLCwillonlyappearinthelowerspasidewindowwhenthepump(s)isnotoperating.Theerror
isalsoaprotectivefeatureandisanindicationthatthepressureswitchinneedofadjustment.
Performthefollowingteststobesurethatyouhaveproperlydiagnosedtheproblem:
Note:Theremustbeenoughwaterinthespafornormaluse.Theheaterwillnotactivatewhilethiserroris
displayed.
!Disconnectthepressureswitchcordattheprintedcircuitboard,iftheerrordoesnotgo
awayreplacetheprintedcircuitboard.
PressureSwitchAdjustment
1
2
3
P
S
I
CalibrationScale(1lb.)
AdjustmentScrew
Thefunctionofthepressureswitchistoturntheheateroffifthepumpstopsoperatingorifthereisrestrictedwaterflow
(dirtyfilter,obstructioninthespaplumbingetc.).
Thepressureswitchhasbeenpresetatthefactorytooperateproperlyinnormalconditions.Adjustmentorotherservice
mayberequiredifyouobserveaflowrelatedproblem.Ifadjustmentisrequired,followthenextstepscarefully.
IMPORTANT:Afteranypressureswitchadjustment,itisimportanttotestthecontrolbyturningon
thepumplowspeedandheater.Whileoperating,unplugthepump,theheatermustturnoff.Ifthe
heaterstayson,plugthepumpbackinandreadjustthepressureswitchtoachieveproperoperation.
1)WithpowertosystemturnedOFF,removethewiresfrom
thepressureswitchterminals(securewiressafelytoprevent
anychanceofelectricalshock).
2)TurnpowertothesystemON.Ifsystemautomaticallystarts
inlowspeed,pressDownArrowkeytosettemperatureto
itslowestsetting(pumpwillturnoffaftercooldowncycle).
3)PlaceanOhmmeteracrossthepressureswitchterminalsto
verifyanOPENcircuit.
4)Rotatethepressureswitchadjustmentscrewcounter-
clockwiseuntiltheOhmmeterindicatesanCLOSEDcircuit.
5)Thenrotatethepressureswitchadjustmentscrewclockwise
untiltheOhmmeterindicatesanOPENcircuitagain.
6)TurnpowertothesystemOFFandreconnectpressure
switchterminals.Reapplypowertothesystemandresume
normaloperation.
5
Error-FLC