UNBOXING
• The Conventional Expander Module has removable top and bottom front plastics to cover screw housings.
• The Conventional Expander Module is housed in an IP65 rated box, with knockouts for IPrated
glands.
•4 plastic screws are provided to secure the lid.
For more information, please refer to the complete product manual.
IMPORTANT TO CONSIDER
When mounting a wireless device a comprehensive radio survey
should have been carried out to establish the location that provides
the best coverage and optimum reach. Taking into consideration the building
structure and materials, the survey identifies the wireless infrastructure
required and product locations for optimum performance, identifying
any factor that could prevent radio integrity.
Avoid fixing or mounting the unit close to the following:
• Equipment that utilises large electrical currents
• Large metal objects or structures
• Fluorescent lighting fittings
• Metal ceiling structures
• IT cabling.
Keep 2 meters minimum spacing between other wireless equipment
in the area to avoid signal interference.
EN54 approved environmental temperature range is -10°C to +55°C
MOUNTING STEPS
The Conventional Expander Module is IP65 rated, suitable for external mounting. The back box must be installed on the wall as flat
as possible to retain IP rating,to prevent distortion of the housing and the ingress ofcontamination and/or moisture.
Proceed as follows to complete the device installation.
Remove top and bottom front plastics that cover screws,
unscrew all four screws and remove the lid fromthe back box.
1
3
2
4
5
Using a suitable-sized drill bit (4mm) drill the pre-defined
screw mounting points in the 4 corners of the backbox.
6
SCREWS
Remove the electronic PCB assembly from the enclosure.
The PCB is held by two Philips screws below the display,
it then slides up and out.
Prepare apertures (20mm knockouts) required for cable
access and fit appropriate rated glands.
Screw the back box to the wall using all fixing holes
and appropriate-sized roundhead screws (do not use
countersunk screws). Insert cable,tighten glands and refit PCB and securing screws.
MOUTING HOLES
SCREWS HOLES
NO
YES
TAU-CEM-01
HYFIRE TAURUS CONVENTIONAL EXPANDER MODULE
QUICK START GUIDE
Unit B12a, Holly Farm Business Park, Honiley, Warwickshire, CV8 1NP
T
: +44 (0)1926 485282, E: info@hyfirewireless.co.uk, W: www.hyfirewireless.com
INSIDE THE BOX
• 1 x Conventional
Expander Module
Battery not included for item
code TAU-CEM-01/NB
• 4 x Screws
• 1 x CR2032 battery
• 1 x Quick start guide
• 1 x QR code
L50-MEC-1400 (Rev_P.5)
THE BOX
Taurus QR code
Manual QR code
Product code
Product name
TAU-CEM-01
Hyfire Taurus
Conventional
Expander Module
Available also without batteries: TAU-CEM-01/NB
• Connectthe conventional zone line’s terminals to the
relevant connector.
• Install the Alarm and the Line EOL resistors and connect
to the relevant connector. Note: resistor’s value should be
indicated in the control panel’s datasheet / instructions
manual.
• Connect the sounder line’s terminals (optional) tothe relevant
connector and ensure you install the correct sounders REOLresistor.
8
7
10
The conventional expander will power up and will be ready
for commissioning.
• Connect the power supply terminals (EN54-4 certified
power source is required).
•Connectthe power supply’s monitoring inputs (optional).
• Screw the lid to the back box using the supplied plastic
screws and refit top and bottom front plastics that cover
screw housings.
• Put the QR code available in the box either on the system
map or on the dedicated pages at the end of conventional
expander manual.
GREEN LED
MAINS FAULT
PULL-UP TO 3V3 BATTERY FAULT
BATTERY
CHARGER FAULT
BATTERY O/C
ext. power (-)ext. power (+)
ZONE
CIE
ZONE
LINE
ZONE
+
ALARM
+
ALARM
LINE
REOL
ALARM
REOL
CIE
SOUNDERS
REOL
SOUNDER
LINE
SOUNDERS
LINE +
SOUNDERS
LINE
SOUNDERS
EOL +
SOUNDERS
EOL
TAU-CEM-01
HYFIRE TAURUS CONVENTIONAL EXPANDER MODULE
QUICK START GUIDE
Unit B12a, Holly Farm Business Park, Honiley, Warwickshire, CV8 1NP
T
: +44 (0)1926 485282, E: info@hyfirewireless.co.uk, W: www.hyfirewireless.com
L50-MEC-1400 (Rev_P.5)

This manual suits for next models

1

Other hyfire Control Unit manuals

hyfire HFW-CEM-02 User manual

hyfire

hyfire HFW-CEM-02 User manual

hyfire HFI-IO-404-01 User manual

hyfire

hyfire HFI-IO-404-01 User manual

hyfire TAURUS TAU-MI-S-01/NB User manual

hyfire

hyfire TAURUS TAU-MI-S-01/NB User manual

hyfire TAURUS TAU-MO-SB-01 User manual

hyfire

hyfire TAURUS TAU-MO-SB-01 User manual

Popular Control Unit manuals by other brands

Kuhse KEA 350 P1 Series user manual

Kuhse

Kuhse KEA 350 P1 Series user manual

Solinst 464 250 psi Replacement

Solinst

Solinst 464 250 psi Replacement

Allen-Bradley 2711P-RN6K installation instructions

Allen-Bradley

Allen-Bradley 2711P-RN6K installation instructions

Siemens SIMATIC S7-1200 Function manual

Siemens

Siemens SIMATIC S7-1200 Function manual

Linak JUMBO Care user manual

Linak

Linak JUMBO Care user manual

Hemisphere GPS P306 Integrator guide

Hemisphere GPS

Hemisphere GPS P306 Integrator guide

Clack Water Specialist EI Programming and Cover Drawing Manual

Clack

Clack Water Specialist EI Programming and Cover Drawing Manual

Mircom RB-MD-950 Replacement instructions

Mircom

Mircom RB-MD-950 Replacement instructions

Goetze 481 Assembly and maintenance instructions

Goetze

Goetze 481 Assembly and maintenance instructions

Agilent Technologies NW16 instruction manual

Agilent Technologies

Agilent Technologies NW16 instruction manual

Samson 3259 TRANSLATION OF ORIGINAL INSTRUCTIONS

Samson

Samson 3259 TRANSLATION OF ORIGINAL INSTRUCTIONS

mods4cars STHBMN1 Installation

mods4cars

mods4cars STHBMN1 Installation

Turbosmart Gen V eALV40 manual

Turbosmart

Turbosmart Gen V eALV40 manual

FAAC 596/615 BPR manual

FAAC

FAAC 596/615 BPR manual

GEA DHV operating instructions

GEA

GEA DHV operating instructions

LG WL1BKR22 user manual

LG

LG WL1BKR22 user manual

Flowserve NAF-Setball Maintenance and installation instructions

Flowserve

Flowserve NAF-Setball Maintenance and installation instructions

Trane CG-SVN01A-EN Installation

Trane

Trane CG-SVN01A-EN Installation

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.