manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. hylite
  6. •
  7. Floodlight
  8. •
  9. hylite Mightylite MFL015 Manual

hylite Mightylite MFL015 Manual

This manual suits for next models

1

Other hylite Floodlight manuals

hylite HLF060 User manual

hylite

hylite HLF060 User manual

hylite MIGHTYLITE PRO MLP120 Manual

hylite

hylite MIGHTYLITE PRO MLP120 Manual

hylite Mightylite MLF136 User guide

hylite

hylite Mightylite MLF136 User guide

hylite Mightylite Pro Manual

hylite

hylite Mightylite Pro Manual

hylite MIGHTYLITE Manual

hylite

hylite MIGHTYLITE Manual

hylite Mightylite Pro MLP240B Manual

hylite

hylite Mightylite Pro MLP240B Manual

hylite MIGHTYLITE MFL016 Manual

hylite

hylite MIGHTYLITE MFL016 Manual

Popular Floodlight manuals by other brands

V-TAC VT-5192S installation instructions

V-TAC

V-TAC VT-5192S installation instructions

Major tech HLF30CW instruction manual

Major tech

Major tech HLF30CW instruction manual

EuroLite LED Cube user manual

EuroLite

EuroLite LED Cube user manual

EuroLite LED IP FL-100 SMD user manual

EuroLite

EuroLite LED IP FL-100 SMD user manual

Cooper Wheelock XB12 specification

Cooper Wheelock

Cooper Wheelock XB12 specification

Allen + Roth 17624-000 user manual

Allen + Roth

Allen + Roth 17624-000 user manual

ADJ 4 STAGE PAK User instructions

ADJ

ADJ 4 STAGE PAK User instructions

Cooper Lighting EGL91SW233 Specification sheet

Cooper Lighting

Cooper Lighting EGL91SW233 Specification sheet

Max 37496 instruction manual

Max

Max 37496 instruction manual

BEGA 85 143 Instructions for use

BEGA

BEGA 85 143 Instructions for use

Cameo CLPST64Q8W user manual

Cameo

Cameo CLPST64Q8W user manual

Beamz 151.226 user manual

Beamz

Beamz 151.226 user manual

EuroLite LED IP FL-8 user manual

EuroLite

EuroLite LED IP FL-8 user manual

Ledj PERFORMER 36 RGB user manual

Ledj

Ledj PERFORMER 36 RGB user manual

Perel ELS3 user manual

Perel

Perel ELS3 user manual

Perel ELS3WD user manual

Perel

Perel ELS3WD user manual

Xtricity 4-80053 instructions

Xtricity

Xtricity 4-80053 instructions

Stahl 6521/4 Series operating instructions

Stahl

Stahl 6521/4 Series operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Mightylite 15W / 24W LED Floodlights
Model: MFL015 / MLF024
Installation & operating instructions
F4 Enterprises Limited
7 Abbey Square, Chester
CH1 2HU, UK
Tel: +44 (0)1352 736120
www.f4enterprises.co.uk
Fig.7
Fig.6
Fixing Holes
FIXING THE CONNECTION BOX (Cont)
• UsetheconnectionboxFixingHoles[Fig.6]tomarkthe4drillholesrequiredto
 securetheboxtothewall(andmarkthecableoutletlocationifrequired).Drill
 thewallandscrewtheconnectionboxontothewallusingthescrewsandwall
 plugsprovided.
• Oncethewire(s)hasbeenfedthroughtheSealingGland,thenutonthegland
 shouldbegentlytightenedupagainsttheglandbody[Fig.8]toensurethe
 wire(s)issecuredinplaceandnowatercangetthoughintotheconnectionbox.
WIRING THE FLOODLIGHT
• Oncethepowercablehasbeenfedthroughthecablegland(orsealing
 grommetifusingtheknock-outattherearoftheconnectionbox) 
 approximately6mmofinsulationshouldbestrippedfromeachofthecoresof
 ACcablereadytoattachittotheterminalblockinthefrontofthelighttting.
NOTE: The Hylite Mightylite is a Class 2 fitting, therefore no Earth is required
CONNECTING TO POWER SUPPLY
• ConnecttheBROWNorRED(Live)wiretotheterminal(marked“L”)holdingthe
 singleBROWNwireintheoodlightunit[Fig.8].
• ConnecttheBLUEorBLACK(Neutral)wiretotheterminal(marked“N”)holding
 theBLUEwireintheoodlightunit.
• Aftertheconnectionshavebeensecured,theoodlightfront(ConnectionBox
 front)shouldbefastenedtotheConnectionBoxusingthe4ConnectionBox
 Screwsprovided[Fig.9]
• Oncescrewsaresecure,thescrewcovers(provided)shouldbettedshouldbe
 tted[Fig.9]
• ToadjusttheMightyLitesimplyholdtheConnectionBoxrmlywhilstmoving
 theheadoftheoodlighttotherequiredposition.
Fig.9
Fig.8
WIRING REQUIREMENTS
Fig.1
FUSE
3 AMP FUSE
TO LAMP
FROM MAINS
SUPPLY
DOUBLE-POLE SWITCHED FUSED SPUR
F
1
2
5
4
3
T R
PIR
sensor
More sensitiveLess sensitive
L
N
SL
E
Override switch
Live
C L1
Neutral Earth
To Mains MightyLite
N In N Out
L In L Out
Theunitrequiresconnectiontoa230AC50Hzmainselectricitysupply.
Itisrecommendedthattheunitisconnectedtothedomesticlightingcircuitviaa
5ampfusedspurandusing2-coreroundexiblecableofatleast1mm2gauge
(waterproofcableshouldbeusedforoutdoorinstallations).
Itisalsoadvisabletoinstallasinglepolewallswitchtoalloweasycontrolofthe
oodlight(Fig.1).
IMPORTANT OPERATION & MAINTENANCE INSTRUCTIONS
TheHyliteMightyliteoodlightalowenergy,highpoweredoutdoorLEDoodlightwhichissuitableforinstallationonsolid
wallsinarangeoflocationsincludingentrances,gardens,staircases,garagesandoutdoorparkingareas.
Theunitrequiresconnectiontoa230AC50Hzmainselectricitysupply.
IMPORTANT SAFETY INSTRUCTIONS
HYLITE MIGHTYLITE – INSTALLATION AND OPERATING INSTRUCTIONS
  DONOTpositionthelightnearammableorcombustiblematerials(suchasclothorpaper)ornearammable, 
  combustibleorexplosiveliquids,solids,gasesorequipment.
  DONOTlookdirectlyintothelightorpointittowardsaperson’seyes.Thislighthasaveryintensivelightoutputwhich,
  ifincorrectlyused,couldcauseeyedamage.
  ALWAYSdisconnectthemainspowersupplybeforeinstalling,servicingorperforminganymaintenance.
  ALWAYSmaintainthelightingoodcondition,withrepairsonlyundertakenbyaqualiedelectrician.
  ONLYcarryoutrepairsusinggenuineparts.Non-authorisedpartsmaybedangerousandwillinvalidatethewarranty
WARNING: THIS PRODUCT MUST BE INSTALLED BY A QUALIFIED ELECTRICIAN, AND CHECKED TO ENSURE IT IS SAFE BEFORE USING
PLEASEFOLLOWTHESEINSTRUCTIONSCAREFULLYBEFOREATTEMPTINGTOINSTALLANDOPERATETHISLIGHT
  Theriskofelectricshockshouldbeminimizedbytheinstallationofappropriatesafetydevicesincludingthe 
  incorporationofanRCCB(ResidualCurrentCircuitBreaker)intothemaindistributionboard.
  DONOTwirethisoodlightdirectlyintothelightingcircuit.Useaswitchedfusedspur.Cablesshouldalwaysbe 
  protectedagainstshortcircuitandoverloadbyuseofanRCD.
  Ensurethevoltagemarkedontheproductisthesameastheelectricalpowersupplytobeused.
  DONOTinstallthelightwhereitislikelytobeknockedorhit;inhotorhumidconditionssuchasbathrooms,shower
  roomsorsaunas;ornearanexhaustoutlete.g.boilerue,dryeroutlet.
TOOLS REQUIRED
Electric/hand-helddrill
No.8masonrydrillbit
Electriciansscrewdriver
Largecross-headscrewdriver
Smallcross-headscrewdriver
Wire cutters
THISPRODUCTISSUITABLEFORWALLMOUNTINGONLY.
PARTS INCLUDED
1 x Mightylite LED Floodlight
1xConnectionbox
1xCablegland
4xConnectionboxscrews
4xConnectionboxscrewcovers
4xConnectionboxxingscrews
4xConnectionboxxingscrewcovers
Fig.2
FUSE
3 AMP FUSE
TO LAMP
FROM MAINS
SUPPLY
DOUBLE-POLE SWITCHED FUSED SPUR
F
1
2
5
4
3
T R
PIR
sensor
More sensitiveLess sensitive
L
N
SL
E
Override switch
Live
C L1
Neutral Earth
To Mains MightyLite
N In N Out
L In L Out
3-5m
Fig.5
Fig.4
Fig.3
Landscape
Portrait
FIXING THE CONNECTION BOX
WARNING: Isolate the power supply before installation.
• Positiontheunitonthewallandmarkthepositionfortheconnectionbox
 (whichcanbepositionedineitherlandscapeorportraitplanes[Fig.3]).
• Ensurethewirescaneasilyentertheconnectionboxthrougheitheroneofthe
 knock-outsonthesideoftheconnectionbox,orthroughtheknock-outatthe
 rearofthebox.
NOTE: It is recommended that the knock-outs on the sides of the
connection box are used in conjunction with the cable gland [Fig 4.] as
using the knock-out at the rear of the connection box will reduce the
weatherproof rating of the unit to IP23.
• However,Iffeedingawire(s)throughtheknock-outattherearoftheconnection
 box,thiswillneedtoberemoved,thesealinggrommettted[Fig.5]andthe
 wirepushedthroughintotheconnectionboxBEFOREitissecuredtothewall.
• Iffeedingawire(s)throughthesideknock-outs,itiseasiesttotthecable
 glandtotheconnectionbox[Fig.4]BEFOREsecuringittothewall,andwires
 shouldentertheconnectionboxfromthesidesorunderneath,NOTfromthetop.
CHOOSING A MOUNTING LOCATION
INSTALLATION INSTRUCTIONS
• Mounttheoodlightontosolidbrickorwoodwork,3-5mabovetheground
 [Fig.2]
• Avoidpositioningthelightnearheatsourcessuchashotventilatorducts,air
 conditioningunits,streetlightingortrafcwhichmayinterferewithitsoperation.