INTRODUCTION
The i4H-KP-3S is not only a multi-user wireless keypad to control the operation of
i4H-LS-20, but also a remote controller to switch on/off lights or appliances to provide
you with home automation conveniences. It can control device operation individually or
multiple devices/operations by a one-touch scene command, according to the scene
settings in the system. Thanks to its backlight feature, a user can operate it in dark
environment. With its 9 sets of 4-digit passwords, it prevents unauthorized use and
identifies the user who controls the operation of the system. Each command would be
acknowledged by the base unit because 2-way radio technology is used.
FEATURES
1. Two-way radio.
Each command will be echoed by the Base Unit.
Two short beeps (bi, bi) means the command was accepted.
One long beep (bi------) means no valid echo was received.
2. Nine user passwords (4-digit for each).
Password 1: Master password (default: 0000).
Password 2-9: User password.
3. Individual operation and switch control.
Directly control the Base Unit main zone operation and 8
switches.
4. Request for system operation status.
Press the “?”key then the Base Unit will return the system operation status and show
the status on the LEDs.
5. One-touch scene control for switch and operation.
(Refer to the HyperSecureLink software, Scheduling\Switch Scene and \Operation Scene)
8 operation scenes: Away/ Disarm control of the Main zone and partial zones from 91-99.
8 switch scenes: On/Off control of 15 switches
6. Invalid key entries protection.
The keypad will lock itself for 3 minutes if 20 consecutive invalid key strokes are
detected and tamper signal will be issued.
7. Tamper detection.
Two tamper detectors (optional), one for the removal from the bracket (can be disabled
when needed) the other for the opening of the battery cover.
8. Low Battery Detection.
When weak battery is detected, the backlit LED will flash with every keystroke and a
low battery signal will be sent to the Base unit every 24 hours.
Note: Since the tampering signal will be emitted when you open the battery hatch, you
better disable the Tamper Siren function in the system before changing batteries to
avoid the siren activated.
9. Seven degrees of slant angle bracket installation makes operation easier.
INSTALLATION
i4H-KP-3S can be wall mounted near the entrance or carried around by users as a
remote controller at home.

Wall Mounting: Note: Your wireless keypad should be mounted out of the reach of
children.
A) Choose a convenient location like on the doorjamb or on the wall adjacent to the
entrance.
B) Using the bracket as a template, mark the holes on the wall by a pencil. Drill 3/16 inch
(4.7mm) pilot holes 1 inch deep for the screws. Fix the bracket with the screws.
Note: For the wall mounting, you can enable the tamper (optional) protection function.
Once the Keypad is taken away from the bracket then a tamper signal will be
passed to the Base Unit.
INITIAL SETUP
Enroll to the Base Unit
1. Keep pressing the Clear/Enroll Button on i4H-LS-20for over 3 seconds and then
release it, the i4H-LS-20would keep beeping and all LEDs blink. This means the
system is ready for enrolling device.
2.Within 30 seconds enter Master Password (default: 0000) followed by
button on the i4H-KP-3S (refer to the diagram below). If you hear 3 short beeps soon
later then enrolling successes, otherwise you will hear one long beep after 30 seconds
that means enrolling fails, you have to repeat enrolling action.
Note: Avoid activating any other sensors during the 30 seconds Device Enroll period.
Remarks: In case you have to change the i4H-KP-3Sattribute, please do it on the cloud
web directly, or refer to HyperSecureLink software user guide to change it by
computer.
Key entry “Master PSW”
Indication/sound Green LED On Green LED flash 3 sec/ 2 beeps Status LED flashes 10sec.
PASSWORD MANAGEMENT
Home
Disarm
Bracket
Tamper
(option)
Bracket Tamper
Enable/Disable
Disable Enable
Battery
Battery Cover
Tamper
(inside, option)
Back Cover
Away
Home
Disarm
Bracket
Screw
Holes

Set/Chang Password:
Key entry “Master PSW”“nxxxx” “nxxxx”
Indication/sound Green LED On Yellow LED On Green LED flashes twice/2 beeps
n= 1, Master Password (default “0000”)
n= 2~9, User Password
xxxx= New password.
Remarks: If the new password existed already then the Keypad will escape with a long
beep.
Delete Password:
Key entry “Master PSW” “n0000”
Indication/sound Green LED On Green LED flashes twice/2 beeps
n= 2~9, (Note: number ‘”1” Master and number “*” Duress can’t be deleted)
Away Arm (no exit delay):
Key entry “4-digit PSW”
Indication/sound Green LED On Green LED flashes 1.5s/ 2 beeps/ Red LED flashes 10s
Base Unit action Enter Away mode
Away Arm (with exit delay):
Key entry “4-digit PSW”
Indication/sound Green LED On Green LED flashes 1.5s/
Red LED flashes and beeper sounds in the delay time/
Green LED flashes 1.5s/ 2 beeps/
Red LED flashes 10s
Base Unit action Enter Away mode
Quick Away Arm:
Key entry Press for 2sec.
Indication/sound Red LED On All the responses are the same as Away Arm
Base Unit action Enter Away mode
Home Arm:
Key entry “4-digit PSW”
Indication/sound Green LED On Green LED flashes 1.5s/ 2 beeps Yellow LED flashes 10s
Base Unit action Enter Home mode
OPERATION CONTROL
Before using i4H-KP-3S to control the system remotely, you have to program a proper Exit/Entry Delay Time on the Base
Unit.

Disarm:
Key entry “4-digit PSW”
Indication/sound Green LED On Green LED flashes 1.5s/ 2 beeps Green LED flashes 10s
Base Unit action Enter Disarm mode
Status Check:
Key entry Press
Indication/sound Green LED flashes 1.5s/ 2 beeps Status LED flashes 10s
Panic Alarm Report:
Key entry Press and
Indication/sound Green LED flashes 1.5s/ 2 beeps
Base Unit action Activate Panic Alarm
Key entry Press & for 3sec. Press “1”or“0” in 5sec. (1=Enable, 0=Disable)
Indication/sound Green LED on 2 beeps
Individual Switch On:
Key entry Press Press switch number (“1”to“8”)
Before using the Switch & Scene Control, this function must be enabled and the scenes on the Base Unit must be set first.
What is Scene Control?
Scene Control means that you can control multiple switches or operations with one command. The user can set
scenes of the system by HyperSecureLink software on computer, and then control or switch scenes from
the i4H-KP-3S.

Indication/sound Yellow LED on Green LED flashes 1.5s/ 2 beeps
Base Unit action Corresponding switch on.
Individual (All) Switch Off (number 0 is all Off):
Key entry Press Press switch number (“0” or “1”to“8”)
Indication/sound Yellow LED on Green LED flashes 1.5s/ 2 beeps
Base Unit action Corresponding switch(s) off.
Switch Scene Control:
Key entry Press Press Press scene number (“1”to“8”)
Indication/sound Yellow LED on Green LED flashes 1.5s/ 2 beeps
Base Unit action Corresponding switches on/off.
Operation Scene Control:
Key entry “Master PSW” Press Press scene number (“1”to“8”)
Indication/sound Green LED on Yellow LED on Green LED flashes 1.5s/ 2 beeps
Base Unit action Main and 91-99 zones enter preset state.
How to reset the i4H-KP-3S password
1. Take out the battery
2. Loosen the screws of the plastic case; change the jumper JP7 on the PCB to “CLR”
side.
3. Insert the battery, and then you would hear 4 beeps which means the password is
reset.
4. Restore the JP7 to original position, and then tighten the screws.
SPECIFICATIONS
Power: two AAA alkaline batteries.
Supervision: Sends heartbeat signal at 60-minute intervals. When Tamper or
Low -Battery condition is detected, it reports automatically.
Passwords: 9 users, 4 digits for each.
Current Drain: 10uA @standby, 30mA @ RF operation
Estimated battery life: 2 years (@ operate 20 times/day)
Radio: 2-way communication.
Bracket slant angle: 7 degrees.
Size: 65 x 28 x 15 mm (Not including the bracket)
Weight (w/o battery): about 120g
Table of contents
Popular Keypad manuals by other brands

Contro l4
Contro l4 KPE-10B1 Specifications

C & K Systems
C & K Systems System 236 manual

WindowMaster
WindowMaster WLI 130 installation instructions

Paradox
Paradox Digiplex DGP-641 User quick reference guide

gebatronic
gebatronic Cody Universal 3 quick start guide

Paradox
Paradox Magellan MG32LRF Quick reference manual

U-Prox
U-Prox G1 quick start guide

Audio Design Associates
Audio Design Associates MC-6011 OPERATION AND SETUP MANUAL

Pyronix
Pyronix HIKVISION LEDP/R-WE quick start guide

DSC
DSC PowerSeries Neo HS2TCHP installation instructions

Gianni Industries
Gianni Industries DG-26 Operation manual

CAMDEN
CAMDEN CM-550SK V3 installation instructions