KP04AE/KP04AET should be installed in an indoor
location, not outside the pre ises for security reasons.
1. Re ove the screw at the base, hold the
botto of the Front Housing pull the front
housing fro the back housing.
2. Mount the back housing on the wall using the
screws supplied.
3. Connect the 6 wires fro the ter inal blocks
(JP1, JP2 , JP3) to the Co fort PCB according
to the signal na e. Note the 12V should be
connected to the 12V ter inal on Co fort,
not S12V
4. If ore than one Keypad is used, connect
their 12V and ground wires back to Co fort
individually, not in series to avoid excessive
voltage drop along the cable.
CM9001 Text Synchronisation
If the LCD displays “Wrong Text. Press *1 to sync”.
press and hold the “*” followed by “1” keys to sync the
KP04 text with Co fort. The screen shows
“Downloading” with status bar. After the process
co pletes, the keypad will reset and “beep”. If this
does not work, sign in on the keypad and check if the
Voice enu is heard.
KP04A Settings
•The KP04A has ID set to 1 as default. There are no
shunts for configuration or setting in KP04A as all
setting is done through the Settings Menu.
•Since the keypad is supplied as ID=1 by default, if
there is another Keypad with the sa e ID in the
syste , this will cause a clash of Ids when the new
keypad is connected. To change the ID, wait for 20
seconds before trying to go into the Settings enu.
•Press and hold the * key for 4 seconds until “Enter
Engineer Code” is seen. If Engineer Code has NOT
been enabled, a essage “Engineer Sign in Option is
OFF”. Press F0 on the keypad and try again. The
following keys have the functions shown;