IAI SW-4000TL-10GE User manual

Thank you for purchasing this product.
Be sure to read this documentation before use.
This documentation includes important safety precautions and instructions on how to operate the unit. Be sure to read this documentation to ensure
proper operation.
The contents of this documentation are subject to change without notice for the purpose of improvement.
@2023 JAI
User Manual
SW-4000TL-10GE
SW-4000TL-SFP
High Speed CMOSTrilinear Camera
Document Version: 2.0
Date: 2023-10-04

SW-4000TL-10GE | SW-4000TL-SFP | User Manual (2.0) Table of Contents
- 2 -
Table of Contents
Table of Contents 2
About Technical Note 6
Notice/Warranty 7
Notice 7
Warranty 7
Certifications 7
CE Compliance 7
FCC 7
Warning 8
KC 8
China RoHS 9
Usage Precautions 10
Notes on Cable Configurations 10
Notes on Attaching the Lens 10
Notes on LAN Cable Connection 10
Notes on SFP+ Module Installation 10
Notes on Temperature Conditions 11
Phenomena Specific to CMOS Image Sensors 11
Notes on Exportation 12
Features 13
Parts Identification 14
①Lens Mount (M42-Mount or F-Mount) 14
②POWER/TRIG LED 15
③DC IN/TRIG Connector (12-Pin Round) 15
④AUX Connector (10-pin) 17
⑤RJ-45 Connector (SW-4000TL-10GE) 17
⑥SFP+ Connector (SW-4000TL-SFP) 18
⑦Mounting Holes (M4, 6mm Depth) 18
Preparation 19
Step 1: Install the Software (First Time Only) 19
Step 2: Connect Devices 20

SW-4000TL-10GE | SW-4000TL-SFP | User Manual (2.0) Table of Contents
- 3 -
①Lens 21
②Mounting 21
③LAN Cable (SW-4000TL-10GE) 22
➃Network Card (SW-4000TL-10GE) 22
⑤DC IN / Trigger IN Connection Cable 22
⑥AC Adapter (Power Supply) 22
⑦SFP+ Module (SW-4000TL-SFP) 23
⑧Fiber Optic Cable (SW-4000TL-SFP) 23
Step 3: Verify Camera Operation 23
Step 4: Verify the Connection between the Camera and PC 24
Step 4: Configure Basic Settings for the Camera 26
Control via External Triggers 27
Control Without External Triggers 29
Step 6: Adjust the Image Quality 30
Display the Image 30
Configure Basic Settings 31
Step 7: Save the Settings 32
To Save User Settings 32
To Load User Settings 33
Main Functions 34
Basic Function Matrix 34
GPIO (Digital Input/Output Settings) 35
Camera Output Formats 35
Exposure Mode 36
Image Output Timing 36
ExposureMode: Off 37
ExposureMode: Timed 38
ExposureMode: TriggerWidth 39
Pixel Sensitivity Correction 40
PRNU Correction (Pixel Gain Correct) 40
DSNU Correction (Pixel Black Correct) 41
Gain Control 42
LUT (Lookup Table) 43

SW-4000TL-10GE | SW-4000TL-SFP | User Manual (2.0) Table of Contents
- 4 -
To Use the LUT Function 43
LUT Value 43
Gamma Function 44
To Use the Gamma Function 44
Shading Correction 45
To Use the Shading Correction Function 46
Black Level Correction 46
Variable Line Rate 47
Electronic Shutter 48
ExposureActive (EEN) Function 48
Color Space Conversion (Color Transformation Control) 49
Test Pattern Function 50
Counter and Timer Control Function 51
Counter Occurrence Diagram 52
Internal Camera Blocks 52
To Use the Counter Function 53
Tilted View Correction and Chromatic Aberration Correction 54
Spatial Compensation 55
Connecting Rotary Encoders 56
Frame Start Trigger 57
Binning 58
ROI (Regional Scanning Function) 59
Delayed Readout 59
Chunk Data Function 60
Event Control Function 61
Action Control Function 62
Action Control Example 63
Layout of pixels 64
PTP (Precision Time Protocol) 65
Noise Reduction Filter Functions 66
Non-Volatile Flash Memory 66
Setting List (Feature Properties) 67
Selector 67

SW-4000TL-10GE | SW-4000TL-SFP | User Manual (2.0) Table of Contents
- 5 -
DeviceControl 68
ImageFormatControl 70
AcquisitionControl 71
AnalogControl 72
LUTControl 74
ColorTransformationControl 75
DigitalIOControl 76
CounterAndTimerControl 78
EncoderControl 79
Logic Block Control 80
ActionControl 81
EventControl 81
UserSetControl 86
ChunkDataControl 86
TransportLayerControl 89
PulseGenerator 92
Shading 93
Correction 94
SpatialControl 96
Miscellaneous 97
Troubleshooting 97
Power Supply and Connections 97
Image Display 97
Settings and Operations 97
Specifications 98
Package Contents 100
Spectral Response 101
Dimensions 102
SW-4000TL-10GE-F 102
SW-4000TL-10GE-M42 103
SW-4000TL-SFP-F 104
SW-4000TL-SFP-M42 105
Comparison of the Decibel Display and Multiplier Display 106

SW-4000TL-10GE | SW-4000TL-SFP | User Manual (2.0) Table of Contents
- 6 -
User's Record 107
Revision History 108
About Technical Note
Some additional technical information is provided on the JAI website as Technical Notes. In this
manual, if a technical note is available for a particular topic, the above icon is shown. Please refer
to the following URL for Technical notes.
https://www.jai.com/support-software/technical-notes

SW-4000TL-10GE | SW-4000TL-SFP | User Manual (2.0) Notice/Warranty
- 7 -
Notice/Warranty
Notice
The material contained in this manual consists of information that is proprietary to JAI Ltd., Japan,
and may only be used by the purchasers of the product. JAI Ltd., Japan makes no warranty for the
use of its product and assumes no responsibility for any errors which may appear or for damages
resulting from the use of the information contained herein. JAI Ltd., Japan reserves the right to
make changes without notice.
Company and product names mentioned in this manual are trademarks or registered trademarks
of their respective owners.
Warranty
For information about the warranty, please contact your factory representative.
Certifications
CE Compliance
As defined by the Directive 2004/108/EC of the European Parliament and of the Council, EMC
(Electromagnetic compatibility), JAI Ltd., Japan declares that SW-4000TL-10GE and SW-
4000TL-SFP comply with the following provisions applying to their standards.
EN61000-6-2 (Generic immunity standard part 1)
EN61000-6-3 (Generic immunity standard part 1)
FCC
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses, and can
radiate radio frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one or more of the following
measures:
lReorient or relocate the receiving antenna.
lIncrease the separation between the equipment and receiver.
lConnect the equipment into an outlet on a circuit different from that to which the receiver is

SW-4000TL-10GE | SW-4000TL-SFP | User Manual (2.0) Notice/Warranty
- 8 -
connected.
lConsult the dealer or an experienced radio/TV technician for help.
Warning
Changes or modifications to this unit not expressly approved by the party responsible for FCC
compliance could void the user’s authority to operate the equipment.
KC
제조년월은 제품상자의 라벨을 참조하십시오.

SW-4000TL-10GE | SW-4000TL-SFP | User Manual (2.0) Notice/Warranty
- 9 -
China RoHS
The following statement is related to the regulation on “Measures for the Administration of the
Control of Pollution by Electronic Information Products “, known as “China RoHS“. The table
shows contained Hazardous Substances in this camera.
mark shows that the environment-friendly use period of contained Hazardous Substances is
15 years.
重 要 注 意 事 项
有毒有害物质或元素名称及含量表
根据中华人民共和国信息产业部『电器电子产品有害物质限制使用管理办法』, 本产品《有毒
有害物质或元素名称及含量表》如下.
部件名称
有毒有害物质或元素
铅
(Pb)
汞
(Hg)
镉
(Cd)
六价铬
(Cr (VI))
多溴联苯
(PBB)
多溴二苯醚
(PBDE)
SW-4000TL-10GE
SW-4000TL-SFP × 〇 〇 〇 〇 〇
〇:表示该有毒有害物质在该部件所有均质材料中的含量均在 GB/T 26572-2011规定的限量要求以下。
×:表示该有毒有害物质至少在该部件的某一均质材料中的含量超出 GB/T 26572-2011规定的限量要求。
环保使用期限
电子信息产品中含有的有毒有害物质或元素在正常使用的条件下不会发生外 泄或突
变、电子信息产品用户使用该电子信息产品不会对环境造成严重污染 或对其人身、
财产造成严重损害的期限。
数字「15」为期限15年。

SW-4000TL-10GE | SW-4000TL-SFP | User Manual (2.0) Usage Precautions
- 10 -
Usage Precautions
Notes on Cable Configurations
The presence of lighting equipment and television receivers nearby may result in video noise. In
such cases, change the cable configurations or placement.
Notes on Attaching the Lens
How to Clean a Sensor
Avoiding Dust Particles
When attaching the lens to the camera, stray dust and other particles may adhere to the sensor
surface and rear surface of the lens. Be careful of the following when attaching the lens.
lWork in a clean environment.
lDo not remove the caps from the camera and lens until immediately before you attach the
lens.
lTo prevent dust from adhering to surfaces, point the camera and lens downward and do not
allow the lens surface to come into contact with your hands or other objects.
lAlways use a blower brush to remove any dust that adheres.
lNever use your hands or cloth, blow with your mouth, or use other methods to remove dust.
Notes on LAN Cable Connection
Secure the locking screws on the connector manually, and do not
use a driver. Do not secure the screws too tightly. Doing so may
wear down the screw threads on the camera. (Tightening torque:
0.147 Nm or less)
Caution: Secure manually. Do not secure too tightly.
Notes on SFP+ Module Installation
Check the operation manual of the SFP+ module to be used, and attach it or remove it from the
camera. The SFP module can be attached to and removed from the camera only when the
camera is turned off.
Many SFP modules and fiber optic cables are Class 1 laser products. Do not look into connectors
and cables when installing or removing. There is a risk of injury to eyes.

SW-4000TL-10GE | SW-4000TL-SFP | User Manual (2.0) Usage Precautions
- 11 -
Notes on Temperature Conditions
The guaranteed operating temperature and humidity of this camera are -5°C to +45°C, 20% to
80% (non-condensing). Please make sure the following temperature condition is met when
operating the unit.
SW-4000TL-
10GE
The camera's internal temperature sensor detects temperatures of 100 °C or less
during operation.
SW-4000TL-
SFP
The camera's internal temperature sensor detects temperatures of 80 °C or less during
operation.
If the above temperature conditions are exceeded, take measures to dissipate heat according to
your installation environment and conditions.
In addition, when using the SW-4000TL-SFP model, operating temperature range of SFP+
modules varies depending on the product. Please use it after confirming the specifications in the
data sheet of the product to be used.
Depending on the operating environment, the surface of the
camera may become very hot during operation. Do not touch the
camera during operation and while it is being cooled. Also, make
sure that the cable surface and other easily deformable items do
not contact the surface of the camera.
Phenomena Specific to CMOS Image Sensors
The following phenomena are known to occur on cameras equipped with CMOS image sensors.
These do not indicate malfunctions.
lAliasing: When shooting straight lines, stripes, and similar patterns, vertical aliasing
(zigzag distortion) may appear on the monitor.
lBlooming: When strong light enters the camera, some pixels on the CMOS image sensor
may receive much more light than they are designed to hold, causing the accumulated
signal charge to overflow into surrounding pixels. This “blooming” phenomenon can be seen
in the image but does not affect the operation of the camera.
lFixed pattern noise: When shooting dark objects in high-temperature conditions, fixed
pattern noise may occur throughout the entire video monitor screen.
lDefective pixels: Defective pixels (white and black pixels) of the CMOS image sensor are
minimized at the factory according to shipping standards. However, as this phenomenon
can be affected by the ambient temperature, camera settings (e.g., high sensitivity and long
exposure), and other factors, be sure to operate within the camera’s specified operating
environment.

SW-4000TL-10GE | SW-4000TL-SFP | User Manual (2.0) Usage Precautions
- 12 -
Notes on Exportation
When exporting this product, please follow the export regulations of your country or region.

SW-4000TL-10GE | SW-4000TL-SFP | User Manual (2.0) Features
- 13 -
Features
This camera is a 3 × 4096 pixel trilinear (RGB) CMOS line scan camera. The Camera is capable
of high-speed scanning at up to 66kHz (Line Rate). 8-bit and 10-bit video output is possible via
10GigE.
Features Overview
lSW-4000TL-10GE: 10 GigE Interface
lThe camera supports the following Ethernet standards (1000Base-T, 2.5GBase-T,
5GBase-T, 10GBase-T)
lSW-4000TL-SFP: Supports 10GBASE-R
lAttach an SFP+ module to the camera to enable 10 Gigabit Ethernet connection via
fiber optic cable.
lTrilinear line-scan camera
lTilted view correction
lSpatial compensation
lAutomatic detection of scan direction (when using rotary encoders)
lSupport for connection of rotary encoders
lVariety of pre-process functions
lLUT (Lookup Table): Programmable control over gamma and contrast is possible.
lGamma correction: can be set to 1.0, 0.9, 0.8, 0.75, 0.65, 0.6, 0.55, 0.5, or 0.45 (off).
lShading correction (flat field): Non-uniformity (i.e., shading) in the amount of light
generated by the lens and lighting equipment can be corrected.
lVariable line rate: By varying the line rate, the scanning speed of the camera can be
matched to the feeding speed of the object, and the accumulation time can be
lengthened to increase sensitivity.
lMiscellaneous
lTimestamp function
lColor space conversion function (HSI, XYZ, sRGB, Adobe RGB) support

SW-4000TL-10GE | SW-4000TL-SFP | User Manual (2.0) Parts Identification
- 14 -
Parts Identification
Note: An exterior view of the F-mount model is shown above. See the "Dimensions " section for
exterior views of M52-mount models.
①Lens Mount (M42-Mount or F-Mount) ②POWER/TRIG LED
③DC IN/TRIG Connector (12-Pin Round) ④AUX Connector (10-pin)
⑤RJ-45 Connector (SW-4000TL-10GE) ⑥SFP+ Connector (SW-4000TL-SFP)
⑦Mounting Holes (M4, 6mm Depth)
①Lens Mount (M42-Mount or F-Mount)
Mount an M42-mount lens or F-mount lens here.
Note: Before mounting a lens, be sure to refer to ①Lens and confirm the precautions for
attaching a lens and the supported lens types.

SW-4000TL-10GE | SW-4000TL-SFP | User Manual (2.0) Parts Identification
- 15 -
②POWER/TRIG LED
Indicates the power or trigger input status.
LED Status
Lit amber
Camera initializing.
SW-4000TL-SFP: SFP+ module not inserted. Not compatible SFP+ module inserted.
The Ethernet Link has not been established.
Lit green Camera in operation
Blinking
green
During operation in trigger mode, trigger signals are being input.
Note: The blinking interval is not related to the actual input interval of the external
trigger.
③DC IN/TRIG Connector (12-Pin Round)
Related Setting Items: DigitalIOControl
Connect the cable for a power supply or for DC IN / trigger IN here.
Camera Side: HR10A-10R-12PB (71) (Hirose Electric or equivalent)
Cable Side: HR-10A-10P-12S (Plug) (Hirose Electric or equivalent)
Pin No. Input/Output Signal Description
1 GND
2 Power In DC In DC +10V ~ + 25V
3 GND
4 Reserved
5 In OPT IN1 - Line 5
6 In OPT IN1 +
7 Out TTL OUT 4 Line 12
8 NC
9 Out TTL OUT 1 Line 1
10 In TTL IN 1 Line 4
11 Power In DC In DC +10V ~ + 25V
12 GND

SW-4000TL-10GE | SW-4000TL-SFP | User Manual (2.0) Parts Identification
- 16 -
Note: The maximum current rating for the power and ground pins is 1.6A per pin pair. If you
are using a power supply whose voltage would create a current flow above this limit in order
to meet the camera’s maximum power consumption (19.3 W), then power must be connected
via both pin pairs.
SW-4000TL-10GE can also be powered by PoE (Power over Ethernet).
TTL Signal specification
TTL out signal specification (Typ.) Output voltage: Low 0.0V, High 5.0V
Input/Output current: +/-32mA
TTL in signal specification (Typ.) Input voltage: Low 0.0 ~ 0.8V, High 2.0 ~ 5.5V
Caution: About Opto In: Check the recommended external input circuit diagram (reference
example) and connect correctly. If you connect Opto In 1 and Opto In 2 in reverse, camera
may be damaged.
Recommended External Input Circuit Diagram (Reference Example)

SW-4000TL-10GE | SW-4000TL-SFP | User Manual (2.0) Parts Identification
- 17 -
④AUX Connector (10-pin)
Connect the cable for DC IN / trigger IN here.
Camera side: Equivalent to Hirose Electronic 3260-10S3(55)
Cable side: Equivalent to Hirose Electronic 3240-10P-C(50)
Pin No. Attribute Name Description
1 Out TTL OUT2 Line 8
2 Out TTL OUT3 Line 9
3 IN TTL_IN2 Line 10
4 N.C
5 GND GND
6 IN TTL_IN3 Line 13
7 N.C
8 N.C
9 GND GND
10 GND GND
⑤RJ-45 Connector (SW-4000TL-10GE)
SW-4000TL-10GE supports the following Ethernet standards: 1000Base-T, 2.5GBase-T,
5GBase-T, 10GBase-T
Depending on the Ethernet standard to be used, the cable type and the maximum cable length
are limited. For details, refer to "Step 2: Connect Devices".
A: LINKLED
Indicates the link status of the
network.
B: ACTLED
Indicates the network
communication status
A: LINK
Light off Network Link is not established.
Blinking
green -
slow
1000Base-T Link is established.
(Interval 1sec)
Blinking
green -
fast
2.5GBase-T Link or 5GBase-T Link is
established. (Interval 200 msec)
Lit green 10GBase-T Link is established.
B: ACT
Light off No network communication
Blinking
green
(Tx) Network communication in
progress.
Blinking
yellow
(Rx) Network communication in
progress.

SW-4000TL-10GE | SW-4000TL-SFP | User Manual (2.0) Parts Identification
- 18 -
⑥SFP+ Connector (SW-4000TL-SFP)
SW-4000TL-SFP supports 10GBASE-R Ethernet standards.
Requirements specification for SFP+ module:
lSupport 10GBASE-R
lSupport Power level 1
Depending on the Ethernet standard to be used, the cable type and the maximum cable length
are limited.
For details, refer to "Step 2: Connect Devices."
⑦Mounting Holes (M4, 6mm Depth)
Use these holes when mounting the camera directly to a wall or other structural system.

SW-4000TL-10GE | SW-4000TL-SFP | User Manual (2.0) Preparation
- 19 -
Preparation
Read this section to learn how the camera connects to devices and accessories. The preparation
process is described below.
1
Step 1: Install the Software (First Time Only)
lInstall the software for configuring and controlling the camera (eBUS SDK for JAI) on the
computer.
2Step 2: Connect Devices
lConnect the lens, cable, AC adapter, computer, and other devices.
3Step 3: Verify Camera Operation
lVerify whether the camera is turned on and ready for use.
4Step 4: Verify the Connection between the Camera and PC
lVerify whether the camera is properly recognized via Control Tool.
5Step 4: Configure Basic Settings for the Camera
lConfigure the Trigger and Exposure settings.
6Step 6: Adjust the Image Quality
lAdjust the Gain, White Balance and Black Level settings, and adjust the image quality.
7Step 7: Save the Settings
lSave the current setting configurations in user memory.
Step 1: Install the Software (First Time Only)
When using the camera for the first time, install the software for configuring and controlling the
camera (eBUS SDK for JAI) on the computer.
Note: When you install eBUS SDK for JAI, eBUS Player for JAI will also be installed.
1. Download the eBUS SDK for JAI from the JAI website (https://www.jai.com/support-
software/jai-software).
2. Install eBUS SDK for JAI on the computer.

SW-4000TL-10GE | SW-4000TL-SFP | User Manual (2.0) Preparation
- 20 -
Step 2: Connect Devices
SW-4000TL-10GE
SW-4000TL-SFP
①Lens ②Mounting
③LAN Cable (SW-4000TL-10GE) ➃Network Card (SW-4000TL-10GE)
⑤DC IN / Trigger IN Connection Cable ⑥AC Adapter (Power Supply)
⑦SFP+ Module (SW-4000TL-SFP) ⑧Fiber Optic Cable (SW-4000TL-SFP)
This manual suits for next models
1
Table of contents
Other IAI Digital Camera manuals

IAI
IAI WA-1000D-CL User manual

IAI
IAI GOX-5105M-PGE User manual

IAI
IAI AP-1600T-PMCL User manual

IAI
IAI SW-4010Q-MCL-M52 User manual

IAI
IAI GO-5000M-PGE User manual

IAI
IAI CV-M2000 series User manual

IAI
IAI SW-4000T-MCL User manual

IAI
IAI cm-140ge User manual

IAI
IAI SW-8000M-PMCL User manual

IAI
IAI GOX-5105M-5GE User manual