IAI RCON-GW User manual

Driver Unit
Gateway Unit
Terminal Unit
Extension
Unit
Fan Unit
Model
Model Plate (Large)
Refer to “External Dimensions”
for the attached position.
Serial Number
-GW/GWG, -GW-TR
Gateway Unit, Terminal Unit
First Step Guide Second Edition
Thank you for purchasing our product.
Make sure to read the Safety Guide and detailed Instruction Manual (DVD) included with the
product in addition to this First Step Guide to ensure correct use.
This Instruction Manual is original.
• Using or copying all or part of this Instruction Manual without permission is prohibited.
• The company names, names of products and trademarks of each company shown in the sentences
are registered trademarks.
RCON System is constructed not only with the Gateway Unit (RCON-GW/GWG) and Terminal Unit (RCON-
GW-TR) that are explained in this manual, but also with Driver Unit (RCON-PC/PCF/AC/DC/SC), Power
Supply Unit (RCON-PS2), Simple Absolute Unit (RCON-ABU), Fan Unit (RCON-FU), Extension Unit
(RCON-EXT) and SCON Controller (SCON-CB-*-RC) to connect to the extension unit. Please refer to First
Step Guide and Instruction Manual (DVD) of each device for additional instruction related to that device.
Gateway Unit is a communication unit to be connected to the field network and must be located on the left
end of the RCON System.
The terminal unit is a terminal resistor that should be allocated at the right end of RCON System.
This product is comprised of the following parts if it is of standard configuration.
If you find any fault in the contained model or any missing parts, contact us or our distributor.
1. Parts
No. Part Name Model
Numbe
r
Remarks
1 RCON Gateway Unit Refer to “How to read the model
plate”, “How to read the model code” 1
Accessories
2 Terminal Unit
(Terminal Resistance) RCON-GW-TR 1
Select-TRN (with no terminal
unit) in the option if it is not
necessary
3 Fan Unit RCON-FU *1 *1 Indicate number of units in
the option
4 System I/O Connector DFMC1.5/5-S
T
-3.5
(Manufactured by PHOENIX CONTACT)
1 Recommended Cable Size
0.5 to 1.25mm2 (AWG20 to 16)
5 Dummy Plug DP-5 1 For the safety category
compliant type
6 CC-Link Connector
(Enclosed for CC-Link Type)
MSTB2.5/5-STF-5.08 AU
(Manufactured by PHOENIX CONTACT)
1
Terminal Resistance (130
Ω
/
110
Ω
)
enclosed one unit each
Recommended Cable Size
0.3mm2 (AWG22)
7 DeviceNet Connecto
r
(Enclosed for DeviceNet Type)
MSTB2.5/5-STF-5.08 AU M
(Manufactured by PHOENIX CONTACT)
1 Recommended Cable Size
0.3mm2 (AWG22)
8 First Step Guide ME0382 1 This Manual
9
Instruction Manual (DVD)
1
10 Safety Guide M0194 1
(4) System I/O Connector (5) Dummy Plug (6) CC-Link Connector (7) DeviceNet Connector
2. Teaching Tool (Please purchase separately)
A teaching tool such as PC software is necessary when performing the setup for position setting, parameter
setting, etc. that can only be done on the teaching tool. Please prepare either of the following teaching tools.
No. Part Name Model
1
PC Software (Includes USB Exchange Adapter + USB Cable + Peripheral Communication Cable)
RCM-101-USB
2 Touch Panel
T
eaching Pendant TB-02 (Standard
/
Dead Man’s Switch Mounted) TB-02/TB-02D
3 Touch Panel Teaching Pendant TB-03 TB-03
3. Instruction manuals related to this product, which are contained in the instruction manual (DVD).
No. Name Manual No.
1 RCON System Instruction Manual ME0384
2 SCON-CB/CGB/LC/LCG Controller Instruction Manual ME0340
3 PC Software RCM-101-MW
/
RCM-101-USB Instruction Manual ME0155
4 Touch Panel
T
eaching Pendant TB-02 Applicable for Position Controller Instruction
Manual ME0355
5 Touch Panel Teaching Pendant TB-03 Wired Link Applicable for Position Controlle
r
Instruction Manual ME0376
4. How to read the model plate
Mark Explanation of Mark
Use IAI specified cables only.
5. How to read the model code
1. Specifications of Power Supply
Item Specification
Power Inpu
t
Volta
g
e Ran
g
e 24V DC ±10%
Suppl
y
Curren
t
Refer to “Current Ampera
g
e” in RCON Driver Unit First Step Guide
(
ME0383
)
Current Ampera
g
e Refer to “Current Ampera
g
e” in RCON Driver Unit First Step Guide
(
ME0383
)
In-Rush Curren
t
Refer to “Current Ampera
g
e” in RCON Driver Unit First Step Guide
(
ME0383
)
Instantaneous Power Outa
g
e Endurance B
y
24V power suppl
y
Protection Function a
g
ainst Electric Shoc
k
Class Ⅲ
2. Specifications of Control Part
Item Specification
Number of Controlled Axes 1 to 16 axes
Data Memory System Position data and parameters are saved in the nonvolatile memory.
(
There is no limitation in number of writin
g)
SIO Interface (T. P. Connector) Communication System: RS485, Baud Rate: 9.6/19.2/38.4/57.6/115.2/230.4kbps
SIO Interface (USB Connector) Communication System: USB, Baud Rate: 12Mbps
PIO Interface None
Conformed Extension I/O Interface
(Field Network Interface)
CC-Link, CC-Link IE Field, DeviceNet, EtherCAT, EtherNet/I
P
, PROFIBUS-D
P
,
PROFINET IO
Pulse Train Type Unavailable to Control
Brake Output Voltage 24V DC ±10%
Calendar Feature Maintained Duration: Approx. 10 days, Charge Time: Approx. 100 hours
Applied Safety Category B (Safety category applicable type is capable to achieve 4 with external circuit)
Driver Source Cutoff System Drive source cutoff with semiconductor (Power MOSFET)
Stop Input Break Contact Input
Stop Action Turning servo OFF + Drive source cutoff
Enable Input None
T. P. Enable Input Available
Enable Action Turning servo OFF
Protective functions Overcurrent, temperature error, encoder line breakage and overload
Preventive / Predictive Maintenance Feature
Electrolytic capacitor capacity dropdown and Fan revolution dropdown
LED Display Refer to section in “Troubleshooting (LED Display)”
Brake Compulsory Release Feature Brake release switch equipped on driver unit
Jog Jog switch equipped on driver unit
Oversea Certifications CE Marking, UL Standard
3. Environmental Specifications
Item Specification
Environment
Environment of Use Pollution Degree 2
Surrounding Air Temperature 0 to 55°C
Surrounding Humidity 85% RH or less (non-condensing)
Peripheral Ambience of Use Refer to “Installation Environment”
Surrounding Storage Temperature -20 to 70°C
Vibration Durability
Frequency 10 to 57Hz/Swing width: 0.075mm
Frequency 57 to 150Hz/Acceleration: 9.8m/s2
XYZ Each direction Sweep time: 10min. Number of sweep: 10times
Protection Class IP20
Altitude 1000m
Cooling Method Natural air-cooling
Dielectric Withstanding Voltage Between power supply terminal and FG 500V DC 10M
Ω
or more
Front Top
Product Check
Basic Specifications
Names for Each Part
Warnin
g
: Operation of this equipment requires detailed installation and operation instructions
which are provided on the DVD Manual included in the box this device was
packaged in. It should be retained with this device at all times.
A copy of the DVD Manual can be requested by contacting your nearest IAI Sales
Office listed at the back cover of the Instruction Manual or on the First Step Guide.
2A
Serial Number
Model Code (Partially)
Model Plate (small)
It is attached on the
bottom of the panel
front face.
RCON - GWG - PRT - FU4 - **
< Series >
<Type>
GW : Standard Type
GWG : Safety Category Compliant Type <Option>
ET : Equipped with Ethernet
FU* : Equipped with Fan Unit
(* : Indicate number of units to mount from
1 to 8 after FU)
TRN : With No Terminal Unit
<I/OType>
CC : CC-Link Connection Type CIE : CC-Link IE Field Connection Type
DV : DeviceNet Connection Type
EC : EtherCAT Connection Type EP : EtherNet/IP Connection Type
PR : PROFIBUS-DP Type PRT : PROFINET IO Connection Type
<Identification for IAI use only>
* There is no identification in
some cases
Field Network
Connector
SYS LED
STATUS 1 LED
STATUS 0 LED
C ERR LED
MODE LED
STOP LED
T RUN LED
Ethernet Connector
T.P. (SIO) Connector
System I/O Connector
Motor Power Supply
Connector
Control Power Supply
Connector
AUTO/MANU Switch
USB Connector

Copper wire: Connect a ground
wire with a diameter of 1.6 mm
(2mm
2
: AWG 14) or larger.
Earth Terminal
Grounding resistance at 100Ω or less
(Class D grounding)
Connect the ground line to the
FG terminal block on the
controller unit.
Put a tool such as a screwdriver
into the square slot and connect
the line.
1. Gateway Unit
Item Specification
External Dimensions 30W × 115H × 95D [mm]
Mass Approx. 157g
2. Terminal Unit
Item Specification
External Dimensions 12.6W × 115H × 95D [mm]
Mass Approx. 49g
3. Linking Units
Item Specification
External Dimensions (42.6 + 22.6 × N) W × 115H × 95D [mm] N: Total number of driver units and extension units
Mass Approx. (206 + 180 × N1 + 99 × N2) g N1: Number of driver units, N2: Number of extensions units
Installation and Noise Elimination
1. Noise Elimination Grounding (Frame Ground)
2. Precautions regarding wiring method
1) Wire is to be twisted for the 24V DC power supply.
2) Separate the signal and encoder lines from the power
supply and power lines.
3. Noise Sources and Elimination
Carry out noise elimination measures for electrical devices
on the same power path and in the same equipment.
The following are examples of measures to eliminate noise
sources.
1) AC solenoid valves, magnet switches and relays
[Measure] Install a Surge absorber parallel with the coil.
2) DC solenoid valves, magnet switches and relays
[Measure] Consider whether to attach a diode in parallel
to the coil or to use a diode built-in type.
4. Cooling Factors and Installation
Follow the specifications and dimensions shown below when you design and build a control board.
Item Specification Item Specification
Installation
Orientation
Vertical Orientation
(Air outlet upwards)
Surrounding Air
Temperature
0 to 55°C (Refer to section of
“Current Amperage” in ME0383)
Derating equipped when with no
fan unit
Installation
Method Attached on DIN Rails
Installation
Condition See figure below Grounding Class D grounding
* Simple absolute units can be installed in close contact with each other.
Installation Environment
This product is capable for use in the environment of pollution degree 2 *1 or equivalent.
*1 Pollution Degree 2: Environment that may cause non-conductive pollution or transient conductive
pollution by frost (IEC60664-1)
1. Installation Environment
Do not use this product in the following environment.
• Location where the ambient temperature is out of the range between 0 and 55°C (with fan) or
0 and 40°C (with no fan)
• Location where condensation occurs due to abrupt temperature changes
• Location where relative humidity exceeds 85%RH
• Location exposed to corrosive gases or combustible gases
• Location exposed to significant amount of dust, salt or iron powder
• Location subject to direct vibration or impact
• Location exposed to direct sunlight
• Location where the product may come in contact with water, oil or chemical droplets
• Environment that blocks the air vent [Refer to Installation and Noise Elimination]
When using the product in any of the locations specified below, provide a sufficient shield.
• Location subject to electrostatic noise
• Location where high electrical or magnetic field is present
• Location with the mains or power lines passing nearby
2. Storage and Preservation Environment
The storage and preservation environment should comply with the same standards as those for the
installation environment.
In particular, when the machine is to be stored for a long time, pay close attention to environmental
conditions so that no condensation forms. Unless specially specified, moisture absorbency protection is not
included in the package when the machine is delivered. In the case that the machine is to be stored and
preserved in an environment where condensation is anticipated, take the condensation preventive measures
from outside of the entire package, or directly after opening the package.
Connection to Peripheral Devices (Overall Wiring Diagram)
External Dimensions
Model Plate
(Large)
Adhered
Position
N: Total number of driver units and extension units
Do not share the ground wire with or connect
to other equipment. Ground each controller.
Controller
Other
equipment
Controller
Other
equipment
Other
equipment
Surge absorber
Relay
coil
Relay coil
R
C
+24V 0V
+24V 0V
+-
100mm or more
10mm
or more
100mm or more
50mm or more
Ceiling
RCON
Ceiling
10mm 10mm
Simple
Absolute
Unit
or more or more
Ethernet
connector
Field Network
(Cables to be prepared by
user)
Ethernet (Cables to be prepared by user)
USB Cable
(Cables to be
prepared by
user)
(Cables
to be
prepared
by user)
Communication Cable
Motor/encoder Cable
Model Code: CB-ADPC-MPA□□□(-RB)
SCON Cable
Model Code: CB-FC-CTL□□□
(Cables to be prepared by user)
Connector Conversion Unit
Model Code: RCM-CV-APCS
Simple Absolute Unit
+24V, 0V
SCON-CB-*-RC
PSA-24
PC
TB-02
TB-03 PLC
Actuator

Power Supply and Stop Circuit (Example)
In the diagram below shows a circuit related to RCON drive source cutoff. For RCON, motor power is
supplied from the gateway unit, but the circuit related to the drive-source cutoff is on the driver unit side.
• Each driver unit possesses an interface (Drive source cutoff connector: MPI/MPO) available for external
drive source cutoff prepared for each axis.
• Each driver unit possesses a drive source cutoff circuit by semiconductor prepared for each axis. The
motor power should be cut off by STOP Signal. The drive source cutoff circuit by semiconductor
possesses features to detect the overcurrent and to limit the in-rush current.
Note 1 RCON-GW : If nothing is connected to the SIO connector, S1 and S2 will be short-circuited in the controller.
RCON-GWG : If nothing is connected to the SIO connector, S1 and S2 will not be short-circuited in the controller.
To short-circuit, connect the supplied dummy plug DP-5 to the SIO connector.
Note ●When externally shutting off the motor drive source to comply with the safety category or the like, connect a contact
such as a relay to the wiring between the MPI* and MPO* terminals.
●The rating of the STOP-signal to be turned ON/OFF with the contact CR1 is 24 VDC / 10 mA or less.
●The CR1 coil current must be 0.1 A or less.
●When supplying power by turning ON/OFF 24 VDC, leave 0 V connected and supply/cut off +24 V.
Warning : Note that the teaching pendant cannot have a stop for the system side even though it can have a stop for
all the actuators connected to RCON unit.
Current Amperage
For current amperage, refer to the first step guide for RCON driver unit..
Item Document
Control
RCON 24V Driver Unit, Fan Unit, Simple Absolute Unit and Extension Unit First Step Guide ME0383
RCON 200V Power Supply Unit, Driver Unit, Fan Unit, Terminal Unit First Step Guide ME0397
Field Network Wirings and Settings
The field network connector is allocated on the top of the gateway unit. Refer to “Names for Each Part”.
1. CC-Link (RCON-GW/GWG-CC)
Refer to the instruction manuals for each field network master unit and mounted PLC for the details.
Connector Name CC-Link Connector Remarks
Cable Side MSTB2.5/5-STF-5.08 AU
(Manufactured by PHOENIX CONTACT)
Enclosed in
standard package
Controller Side MSTB2.5/5-GF-5.08 AU
(Manufactured by PHOENIX CONTACT)
Pin
No.
Signal Name
(Color) Description Applicable cable
diamete
r
1 DA (BL) Communication Line
A
Dedicated cable
for CC-Link
2DB (WT) Communication Line B
3 DG (YW) Digital Ground
4
SLD Connect the shield of the shielded cable
(Connected inside to 5-pin FG and control power
suppl
y
connector 1-pin FG
)
5
FG Frame Ground
(Connected inside to 4-pin SLD and control power
suppl
y
connector 1-pin FG
)
2. CC-Link IE Field (RCON-GW/GWG-CIE)
Refer to the instruction manuals for each field network master unit and mounted PLC for the details.
Connector Name CC-Link IE Field Connector Remarks
Cable Side Ethernet ANSI/TIA/EIA-568-B Category 5e
and above 8P8C modular plug equipped
with shield (RJ45)
Please prepare
separately
Controller Side Ethernet ANSI/TIA/EIA-568-B Category 5e
and above 8P8C modular Jack equipped
with shield (RJ45)
Pin
No. Signal Name Description Applicable cable
diamete
r
1 TP0+ Data 0+
It is recommended
to prepare a
straight STP cable
in Category 5e or
above for the
Ethernet cable.
2 TP0- Data 0-
3 TP1+ Data 1+
4 TP2+ Data 2+
5 TP2- Data 2-
6 TP1- Data 1-
7 TP3+ Data 3+
8 TP3- Data 3-
3. DeviceNet (RCON-GW/GWG-DV)
Refer to the instruction manuals for each field network master unit and mounted PLC for the details.
Connector Name DeviceNet Connector Remarks
Cable Side MSTB2.5/5-STF-5.08 AU M
(Manufactured by PHOENIX CONTACT)
Enclosed in
standard package
Controller Side MSTB2.5/5-GF-5.08 AU
(Manufactured by PHOENIX CONTACT)
Pin
No.
Signal Name
(Color) Description Applicable cable
diameter
1 V- (BK) Power Supply Cable Negative Side
Dedicated cable
for DeviceNet
2 CAN L (BL) Communication Data Low Side
3 - Digital Ground
4 CAN H (WT) Communication Data High Side
5 V+ (RD) Power Supply Cable Positive Side
4. EtherCAT (RCON-GW/GWG-EC)
Refer to the instruction manuals for each field network master unit and mounted PLC for the details.
Connector Name EtherCAT Connecto
r
Remarks
Cable Side Ethernet ANSI/TIA/EIA-568-B Category 5
and above 8P8C modular plug equipped
with shield (RJ45)
Please prepare
separately
Controller Side Ethernet ANSI/TIA/EIA-568-B Category 5
and above 8P8C modular Jack equipped
with shield (RJ45)
Pin
No. Signal Name Description Applicable cable
diameter
1 TD+ Data sending+
It is recommended
to prepare a
straight STP cable
in Category 5 or
above for the
Ethernet cable.
2 TD- Data sending-
3 RD+ Data receiving+
4 - Disconnected
5 - Disconnected
6 RD- Data receiving-
7 - Disconnected
8 - Disconnected
Top View of
Connector on
Controller side
L.ER
LINK
L.ER
LINK
5
4
3
2
1
Top View of
Connector on
Controller side
Shield
BL (CAN L)
RD (V+)
WT (CAN H)
BK (V-)
Slave Devices
RCON-DeviceNet Type
V+
Drain
(Shield)
CAN_H
CAN_L
V-
RD
WT
BL
BK
RD
WT
BL
BK
V+
Drain
(Shield)
CAN_H
CAN_L
Grounding resistance at 100Ωor less
(Class D grounding)
V+
Drain
(Shield)
CAN_H
CAN_L
V-
RD
WT
BL
BK
Communication power needs to be
supplied by an external device.
Terminal Resistance is required
to be mounted on the terminal.
V-
Terminal Resistance
121Ω
Master Unit
Terminal Resistance
121Ω
24V
Power Supply
5
4
3
2
1
Top View of
Connector on
Controller side
WT (DB)
BL (DA)
Shield (SLD)
YW (DG)
Slave Devices
RCON-
CC-Link
Type
SLD and FG are internally connected.
Terminal Resistance is required
to be mounted on the terminal.
The terminal resistor differs depending on the type
of the dedicated cable for CC-Link.
• Cable FANC-SBH···130Ω1/2W
(High Performance Cable
dedicated for CC-Link)
• Cable FANC-SB······110Ω1/2W
(CC-Link Dedicated Cable)
Master Unit Terminal
Resistance
Terminal
Resistance
Grounding resistance at 100Ωor less
(Class D grounding)
Master Unit Slave Devices RCON EtherCAT Type
Ethernet Straight Cable Category 5 or more
Double shielded cable braided with aluminum foil recommended
(Note) Terminal resistance is not required
Master Unit Slave Devices RCON CC-Link IE Field Type
Ethernet Straight Cable Category 5e or more
Double shielded cable braided with aluminum foil recommended
(Note) Terminal resistance is not required
There is no
distinction of IN/OUT
on the connector.
Gateway unit Driver unit Driver unit
SIO connector
System I/O
connector
Motor
power
connector
Control
power
connector
Note 1
Control
power
24V
Stop
reset
switch
Stop
switch
Teaching pendant
Stop switch
Drive-source
cutoff
connector
Drive-source
cutoff
connector
Motor power Ⅰ
Motor power Ⅱ
Motor power Ⅰ
Motor power Ⅱ
High-side protection circuit
High-side protection circuit
High-side protection circuit
High-side protection circuit
24V
dedicated
for stop
circuit
Top View of
Connector on
Controller side
1
8
1
8
OUT
IN

5. EtherNet/IP (RCON-GW/GWG-EP)
7. PROFINET IO (RCON-GW/GWG-PRT)
Refer to the instruction manuals for each field network master unit and mounted PLC for the details.
Connector Name EtherNet/IP, PROFINET IO Connector Remarks
Cable Side Ethernet ANSI/TIA/EIA-568-B Category 5
and above 8P8C modular plug equipped
with shield (RJ45)
Please prepare
separately
Controller Side Ethernet ANSI/TIA/EIA-568-B Category 5
and above 8P8C modular Jack equipped
with shield (RJ45)
Pin
No. Signal Name Description Applicable cable
diameter
1 TD+ Data sending+
It is recommended
to prepare a
straight STP cable
in Category 5 or
above for the
Ethernet cable.
2 TD- Data sending-
3 RD+ Data receiving+
4 - Disconnected
5 - Disconnected
6 RD- Data receiving-
7 - Disconnected
8 - Disconnected
6. PROFIBUS-DP (RCON-GW/GWG-PR)
Refer to the instruction manuals for each field network master unit and mounted PLC for the details.
Connector Name PROFIBUS-DP Connector Remarks
Cable Side 9-pin D-sub Connector (Male) Please prepare separately
Controller Side 9-pin D-sub Connector (Female)
Pin
No. Signal Name Description Applicable cable diameter
1 NC Disconnected
Dedicated cable for
PROFIBUS-DP
(Type A: EN5017)
2 NC Disconnected
3 B-Line Communication Line B (RS485)
4 RTS Request for Sending
5 GND Signal GND (Insulation)
6 +5V +5V Output (Insulation)
7 NC Disconnected
8 A-Line Communication Line A (RS485)
9 NC Disconnected
Operation Mode Selected
In this controller, it is available to select six types of operation modes individually for each axis as the field
network type.
The settings are to be established with Gateway Parameter Setting Tool.
Operation Mode Contents
Direct Indication
Mode
The target position, speed, acceleration/deceleration and pressing current limit can be
indicated with inputting a number. Monitoring of not only the current position, but also
the current speed and indicated current are available.
Simple Direct Mode
The target position can be indicated directly by inputting a value. Also, monitoring of the
current position is available in 0.01mm unit.
Those other than the target position are to be indicated in the position table, and the
setting can be done for 128 points at maximum.
Positioner 1 Mode
The 128 points of position data can be registered at the maximum and is able to stop at
the registered positions. Also, monitoring of the current position is available in 0.01mm
unit.
Positioner 2 Mode
This is the operation mode of the position data of 128 points at maximum set in the
position table. The monitoring of the current position is not available.
This mode is that the transferred data is reduced from Positioner 1 Mode.
Positioner 3 Mode
This is the operation mode of the position data of 128 points at maximum set in the
position table. The monitoring of the current position is not available.
This is the mode to control with the minimized number of signals to perform the
positioning operation by reducing the amount of sent and received data from Positioner
2 Mode.
Positioner 5 Mode
This is the operation mode of the position data of 16 points at maximum set in the
position table.
It is a mode that enabled to monitor the current position in 0.1mm unit by reducing the
number of position table from Positioner 2 Mode.
Starting Procedures
When using this product for the first time, make sure to avoid mistakes and incorrect wiring by referring to
the procedure below.
In this section, explains how to start up especially for RCON controller. Follow an instruction manual (DVD)
for each device for how to link to other devices, controllers and actuators that are linked in the network.
Troubleshooting (LED Display)
On RCON Gateway Unit, there are the monitor LEDs for the field network and communication.
You can confirm the communication establishment and also communication errors on these LEDs.
Refer to “Names for Each Part” for the position and name of each LED lamp.
Panel
Display Color Status Explanation
T RUN GN Illuminating Inside bus communication in normal conditions
Flashing Waiting for initializing communication
OR Illuminating Inside bus communication in error
SYS GN Illuminating Operating in normal conditions
OR Illuminating Gateway alarm being generated
STOP RD Illuminating Confirmed STOP Signal input
(driver unit drive source being cut off)
OFF No STOP Signal input confirmed
MODE GN Illuminating In AUTO (automatic operation) Mode
OFF In MANU (manual operation) Mode
C ERR OR Illuminating Error occurred in field network
OFF Field network operating in normal conditions
STATUS 0 - - Differs depending on field network (Refer to Field Network
Communication Conditions from 1 to 7)
STATUS 1 - - Differs depending on field network (Refer to Field Network
Communication Conditions from 1 to 7)
[Field Network Communication Conditions]
1. CC-Link (RCON-GW/GWG-CC)
Name Panel
Display Color Status Explanation
STATUS 0 RUN GN
Illuminating
Succeeded in refresh and polling reception after
getting into network, or succeeded in refresh
reception
OFF
1. Not in network
2. Carrier detected for channel
3. Timeover
4. In hardware reset
STATUS 1 ERR GN
Illuminating
1. CRC Error
2. Station number setting error at reset release
(65 stations or more including 0 or occupied
station number)
3. Baud rate setting error at reset release
(5 or more for baud rate setting)
Flashing
(Flash for
0.4sec)
Numbers changed from station numbers and
baud rate setting numbers at reset release
OFF 1. Communication in normal conditions
2. In hardware reset
2. CC-Link IE Field (RCON-GW/GWG-CIE)
Name Panel
Display Color Status Explanation
STATUS 0 MS
GN Illuminating Operation in normal conditions
OFF Hardware error occurred
OR Illuminating Error being occurred
OFF Operation in normal conditions
STATUS 1 NS
GN
Illuminating Cyclic transmission in process
Flashing Cyclic transmission paused
OFF Cyclic transmission not conducted, parallel off
OR Illuminating Received data in error
OFF Received data in normal conditions
LINK - GN Illuminating Linkup in process
OFF Link-down in process
L.ER - OR Illuminating Received data in error
OFF Received data in normal conditions
Top View of
Connector on
Controller side
1
8
No →
Check on Safety Circuit
Confirm that the stop circuit (drive source cutoff circuit) works in normal conditions.
↓Yes
No →
Check of Packed Items
Are all the delivered items present? Contact your local IAI distributor
Installation and Wiring
* Refer to [Installation and Noise Elimination] in this first step guide
Install the controller and actuator and perform wiring according.
Important Check Item
• Is frame ground (FG) connected?
• Has the noise countermeasure been taken?
↓
← Yes
Initial Settings (Setup of Driver Units and Extension Units) * RC PC software is required
Establish the parameter settings for each controller.
PLC (Master Unit) Baud Rate * Refer to PLC Instruction Manual.
Have the settings established for the PLC node addresses (station
numbers) and the baud rate.
Initial Settings (Setup of Gateway) * Gateway parameter setting tool is required
Have the settings done for the axis number setting, mode settings, field network communication speed, node addresses
(station numbers) and so on to suit to the system.
↓
No →
Power Supply
1) Supply the power to PLC (master unit).
2) In case of using the extension units, turn the power on for SCON connected to the extension units.
3) Supply the power to RCON.
Check the status of LED lamps to see the
cause of the error to have an appropriate
counteraction. Do the whole process from
the start if the cause of the error is not
clear.
↓
Communication Establishment Check
• In case of using the extension units, turn the power on for SCON
connected to the extension units.
* Refer to “Troubleshooting” in this first step guide
•
Confirm that communication is established also on PLC (master unit).
* Refer to PLC Instruction Manual.
Check the circuit.
↓Yes
Now, it is succeeded to establish communication and ready for operation.
Move on to the system operation check and adjustment.
↓
Assembling RCON (Linking up Units) * Refer to RCON 24V/200V Driver Unit First Step Guide (ME0383/ME0397)
Join the units to use such as the gateway unit, driver unit, extension unit and so on.
↓
↓
Important Check Item
• Is the control sequence applicable for
the continuous mode and the system?
↓Yes
5 1
9 6
Cable
Shield
Red B line (Positive side)
Green A line (Negative side)
Slave Devices
RCON PROFIBUS-DP Type
Master Unit
Grounding resistance at 100Ωor less
(Class D grounding)
59
6
1
Top View of
Connector on
Controller side
Master Unit
Switching Hub
Slave Devices
RCON-
EtherNet Type
or
RCON-
PROFINET IO Type
Ethernet Straight Cable,
Category 5 or more
Double shielded cable braided with
aluminum foil recommended

3. DeviceNet (RCON-GW/GWG-DV)
Name Panel
Display Color Status Explanation
STATUS 0 MS
GN
Illuminating Operation in normal conditions
Flashing (1Hz) There is no configuration information, or not
complete, device trial run necessary
OR Illuminating Malfunction with no opportunity for recovery
Flashing (1Hz) Malfunction with opportunity for recovery
GN/OR Illuminated by
turns Self‐diagnosis
STATUS 1 NS
GN Illuminating Online, Connection established
Flashing (1Hz) Online, No connection established
OR Illuminating Critical Error
Flashing (1Hz) Connection Timeout
RD/GN
Illuminated by
turns Self‐diagnosis
OFF Offline
4. EtherCAT (RCON-GW/GWG-EC)
Name Panel
Display Color Status Explanation
STATUS 0 ERR OR
Illuminating Communication component (module) error
Flashing
(continuously)
Construction information (setting) error
ON: 200ms / OFF: 200ms
Flashing (twice) Communication part circuit error
ON: 200ms × 2 / OFF: 1000ms
OFF In initializing process
STATUS 1 RUN GN
Illuminating In normal operation (OPERATION)
Flashing
(continuously)
In PRE-OPERATION condition
ON: 200ms / OFF: 200ms
Flashing (once) In SAFE-OPERATION condition
ON: 200ms / OFF: 1000ms
OR Flashing Communication component (module) error
5. EtherNet/IP (RCON-GW/GWG-EP)
Name Panel
Display Color Status Explanation
STATUS 0 MS
GN
Illuminating Operation in normal conditions
Flashing There is no configuration information,
or scanner in idol condition
OR Illuminating Malfunction with no opportunity for recovery
Flashing Malfunction with opportunity for recovery
STATUS 1 NS
GN Illuminating Online, connection established
Flashing Online, No connection established
OR Illuminating Critical error, IP address duplicated error
Flashing Connection Timeout
GN/OR OFF No IP address
6. PROFIBUS-DP (RCON-GW/GWG-PR)
Name Panel
Display Color Status Explanation
STATUS 0 MS
GN
Illuminating Initialization completed
Flashing Initialization completed, there is a diagnosis
event
RD Illuminating Exception error
GN/RD OFF Not initialized
STATUS 1 NS
GN Illuminating Online, data exchange
Flashing Online, cleared
RD Illuminating Parameter error
Flashing Configuration error
GN/RD OFF Offline
7. PROFINET IO(RCON-GW/GWG-PRT)
Name Panel
Display Color Status Explanation
STATUS 0 MS
GN
Illuminating Communication in normal conditions
Flashing (once) In network diagnosis
Flashing (twice) Engineering tools identifying nodes
OR
Illuminating Exception error occurred (malfunction of
hardware)
Flashing (once) Mismatch of setting an actual network
construction
Flashing (twice) IP address not established
Flashing
(three times) Station name not established
Flashing
(four times) Internal error occurred
GN/RD OFF In initializing process
STATUS 1 NS GN Illuminating Online (communication in normal conditions:
RUN)
Flashing Online (STOP)
GN/OR OFF No connection
Head Office: 577-1 Obane Shimizu-KU Shizuoka City Shizuoka 424-0103, Japan
TEL +81-54-364-5105 FAX +81-54-364-2589
website: www.iai-robot.co.jp/
Ober der Röth 4, D-65824 Schwalbach am Taunus, Germany
TEL 06196-88950 FAX 06196-889524
SHANGHAI JIAHUA BUSINESS CENTER A8-303, 808, Hongqiao Rd. Shanghai 200030, China
TEL 021-6448-4753 FAX 021-6448-3992
website: www.iai-robot.com
Technical Support available in USA, Europe and China
Head Office: 2690 W. 237th Street, Torrance, CA 90505
TEL (310) 891-6015 FAX (310) 891-0815
Chicago Office: 110 East State Parkway, Schaumburg, IL 60173
TEL(847) 908-1400 FAX (847) 908-1399
TEL (678) 354-9470 FAX (678) 354-9471
website: www.intelligentactuator.com
Atlanta Office: 1220 Kennestone Circle, Suite 108, Marietta, GA 30066
825 PhairojKijja Tower 7th Floor, Debaratana RD., Bangna-Nuea, Bangna, Bangkok 10260, Thailand
TEL +66-2-361-4458 FAX +66-2-361-4456
website:www.iai-gmbh.de
website:www.iai-robot.co.th
Manual No.: ME0382-2A
This manual suits for next models
2
Table of contents
Other IAI Gateway manuals
Popular Gateway manuals by other brands

Fybr
Fybr Gateway III installation manual

RTA
RTA 460ESDFM-N34 Product user guide

ZyXEL Communications
ZyXEL Communications P-660HN-T1H Specifications

Bosslan
Bosslan 2FXS user manual

Pepperl+Fuchs
Pepperl+Fuchs VBG-EN-K30-DMD-S16 manual

HMS Networks
HMS Networks Intesis IN770PAN00 O000 Series Installation sheet