IAI REC-GW User manual

REC Terminal Unit
EC Connection Unit
Model
Model Plate (Large)
Refer to “External Dimensions”
for the attached position.
Serial Number
Caution Mar
k
Model
Model Plate (Large)
Refer to “External Dimensions”
for the attached position.
Serial Number
Caution Mar
k
-GW, -EC
RCON-GW-TRE
EC Gateway Unit, EC Connection Unit,
REC Terminal Unit
First Step Guide First Edition
Thank you for purchasing our product.
Make sure to read the Safety Guide and detailed Instruction Manual (DVD) included with the
product in addition to this First Step Guide to ensure correct use.
This Instruction Manual is original.
• Using or copying all or part of this Instruction Manual without permission is prohibited.
• The company names, names of products and trademarks of each company shown in the sentences
are registered trademarks.
REC system is constructed with EC Gateway Unit (REC-GW), EC Connection Unit (RCON-EC) and REC
Terminal Unit (RCON-GW-TRE) that are explained in this manual.
EC Gateway Unit is a communication unit to be connected to the field network and must be located on the
most left side of the REC system.
EC Connection Unit is a unit to be connected to the ELECYLINDER and must be located on the right side
of the EC Gateway Unit.
The REC Terminal Unit is a terminal resistor that should be allocated at the most right end of REC system.
This product is comprised of the following parts if it is of standard configuration.
If you find any fault in the contained model or any missing parts, contact us or our distributor.
1. Parts
(1) EC Gateway Unit (REC-GW)
No. Part Name Model
Numbe
r
Remarks
1 EC Gateway Unit Refer to “How to read the model
plate”, “How to read the model code” 1
Accessories
2 REC Terminal Unit
(Terminal Resistance) RCON-GW-TRE 1
Select-TRN (with no terminal
unit) in the option if it is not
necessary
3
CC-Link
Connector
(Enclosed for CC-Link
Connection Type)
MSTB2.5/5-STF-5.08 AU
(Manufactured by
PHOENIX CONTACT)
1
Terminal Resistance (130
Ω
/110
Ω
)
enclosed one unit each
Recommended Cable:
Dedicated cable for CC-Link
4
DeviceNet
Connector
(Enclosed for DeviceNet
Connection Type)
MSTB2.5/5-STF-5.08 AU M
(Manufactured by
PHOENIX CONTACT)
1 Recommended Cable:
Dedicated cable for DeviceNet
5 First Step Guide ME0395 1 This Manual
6
Instruction Manual (DVD)
1
7 Safety Guide M0194 1
(2) EC Connection Unit (RCON-EC)
No. Part Name Model
Numbe
r
Remarks
1 EC Connection Unit Refer to “How to read the model
plate”, “How to read the model code” 1 4 axis type
Accessories
2 Drive Source Cutoff
Connector
DFMC1.5/4-ST-3.5
(Manufactured by PHOENIX CONTACT)
1
Recommended
Cable Size
0.5 to 1.25mm
2
(AWG20 to 16, Copper Wire)
* Use cables with their rated
temperature on the isolation
sheath at 60°C or highe
r
3 First Step Guide ME0395 1 This Manual
4 Safety Guide M0194 1
2. Teaching Tool (Please purchase separately)
A teaching tool such as PC software is necessary when performing the setup for position setting, parameter
setting, etc. that can only be done on the teaching tool. Please prepare either of the following teaching tools.
No. Part Name Model
1
PC Software (Includes USB Exchange Adapter + USB Cable + Peripheral Communication Cable)
RCM-101-USB
2 Touch Panel
T
eaching Pendant TB-02 (Standard
/
Dead Man’s Switch Mounted) TB-02/TB-02D
3 Touch Panel Teaching Pendant TB-03 TB-03
3. Instruction manuals related to this product, which are contained in the instruction manual (DVD).
No. Name Manual No.
1 REC Instruction Manual ME0394
2 PC Software RCM-101-MW/RCM-101-USB Instruction Manual ME0155
3 Touch Panel
T
eaching Pendant TB-02 Applicable for Position Controller
Instruction Manual ME0355
4 Touch Panel Teaching Pendant TB-03 Wired Link Applicable for Position
Controlle
r
Instruction Manual ME0376
4. How to read the model plate (This design is what is after UL/CE acquired.)
(1) EC Gateway Unit
(2) EC Connection Unit
Mark Explanation of Mark
Use IAI specified cables only.
5. How to read the model code
(1) EC Gateway Unit
(2) EC Connection Unit
(3) ELECYLINDER
* ELECYLINDER available for connection to REC System is only Option: ACR.
1. Specifications of Power Supply
Item Specification
Power Input Volta
g
e Ran
g
e 24V DC ±10%
Suppl
y
Curren
t
Described in “Current Ampera
g
e”
Power Suppl
y
Frequenc
y
Ran
g
e -
Current Ampera
g
e Described in “Current Ampera
g
e”
In-Rush Curren
t
Described in “Current Ampera
g
e”
Instantaneous Power Outa
g
e Endurance B
y
24V power suppl
y
Protection Function a
g
ainst Electric Shock
Class Ⅲ
2. Specifications of Control Part
Item Specification
Number of Controlled Axes 1 to 16 axes
Data Memory System FRAM 256kbi
t
SIO Interface (T. P. Connector) Communication System: RS485, Baud Rate: 9.6/19.2/38.4/57.6/115.2/230.4kbps
SIO Interface (USB Connector) Communication System: USB, Baud Rate: 12Mbps
PIO Interface None
Conformed Extension I/O Interface
(Field Network Interface)
CC-Link, CC-Link IE Field, DeviceNet, EtherCAT, EtherNet/I
P
, PROFIBUS-D
P
,
PROFINET IO
Pulse Train Type Unavailable to Control
Brake Output Voltage 24V DC ±10%
Calendar Feature None
Applied Safety Category -
Driver Source Cutoff System Drive source cutoff with semiconductor (Power MOSFET)
Stop Input Break Contact Input
Stop Action Turning servo OFF + Drive source cutoff
Enable Input None
T. P. Enable Input Available
Enable Action Turning servo OFF
Protective functions Overcurrent, temperature error, encoder line breakage and overload
Preventive / Predictive Maintenance Feature
None
LED Display Refer to section in “Troubleshooting (LED Display)”
Brake Compulsory Release Feature Brake release switch equipped on EC Connection Unit
Jog Jog switch equipped on EC Connection Unit
Oversea Certifications Planned to acquire CE and UL
3. Environmental Specifications
Item Specification
Environment
Environment of Use Pollution Degree 2
Surrounding Air Temperature 0 to 55°C
Surrounding Humidity 85% RH or less (non-condensing)
Peripheral Ambience of Use Refer to “Installation Environment”
Surrounding Storage Temperature -20 to 70°C
Vibration Durability
Frequency 10 to 57Hz/Swing width: 0.075mm
Frequency 57 to 150Hz/Acceleration: 9.8m/s
2
XYZ Each direction Sweep time: 10min. Number of sweep: 10times
Protection Class IP20
Altitude 1000m
Cooling Method Natural air-cooling
Dielectric Withstanding Voltage Between power supply terminal and FG 500V DC 10M
Ω
or more
(1) EC Gateway Unit
Front Top
Product Check
Basic Specifications
Names for Each Part
Serial Number
Model Code (Partially)
Model Plate (small)
It is attached on the
bottom of the panel
front face.
Warnin
g
: Operation of this equipment requires detailed installation and operation instructions
which are provided on the DVD Manual included in the box this device was
packaged in. It should be retained with this device at all times.
A copy of the DVD Manual can be requested by contacting your nearest IAI Sales
Office listed at the back cover of the Instruction Manual or on the First Step Guide.
1B
Serial Number
Model Code (Partially)
Model Plate (small)
It is attached on the
bottom of the panel
front face.
< Type >
EC : ELECYLINDER
RCON - EC - 4
< Number of Axes >
4 : 4 axis type
* onl
y
4 axis t
y
pe
< Series >
REC - GW - CC - TRN - **
< Series >
< Type >
GW : Gatewa
y
Uni
t
<Option>
TRN : With No Terminal Unit
< I/OType >
CC : CC-Link Connection Type CIE : CC-Link IE Field Connection Type
DV : DeviceNet Connection Type EC : EtherCAT Connection Type
EP : EtherNet/IP Connection Type PR : PROFIBUS-DP Type
PRT : PROFINET IO Connection Type
< Identification for IAI use only >
* There is no identification in
some cases
T RUN LED
Field Network Connector
< Series > < T
y
pe > <Read> <Stroke> < Option >
ACR : RCON-EC Connection T
y
pe
< Cable length >
EC - - -( ) ---
A
CR
MODE LED
C ERR LED
STATUS 0 LED
STATUS 1 LED
STOP LED
SYS LED
T.P.( SIO )
Connector
AUTO/MANU Switch
Connector for
FG Connection
USB
Connector
24V
Power
Supply Connector

100mm or more
10mm
or more
100mm or more
50mm or more
Ceiling
REC System
Ceiling
10mm
or more
Earth Terminal
Grounding resistance at 100Ω or less
(Class D grounding)
(2) EC Connection Unit
Front
1. EC Gateway Unit
Item Specification
External Dimensions 30W × 115H × 95D [mm]
Mass Approx. 135g
2. EC Connection Unit
Item Specification
External Dimensions 22.6W × 115H × 95D [mm]
Mass Approx. 114g
3. REC Terminal Unit
Item Specification
External Dimensions 12.6W × 115H × 95D [mm]
Mass Approx. 48g
4. Linking Units
Item Specification
External Dimensions (42.6 + 22.6 × N) W × 115H × 95D [mm] N: Total number of EC Connection Units
Mass Approx. (183 + 114 × N) g N: Number of EC Connection Units
Installation Environment
This product is capable for use in the environment of pollution degree 2
*1
or equivalent.
*1 Pollution Degree 2: Environment that may cause non-conductive pollution or transient conductive
pollution by frost (IEC60664-1)
1. Installation Environment
Do not use this product in the following environment.
• Location where the ambient temperature is out of the range between 0 and 55°C
• Location where condensation occurs due to abrupt temperature changes
• Location where relative humidity exceeds 85%RH
• Location exposed to corrosive gases or combustible gases
• Location exposed to significant amount of dust, salt or iron powder
• Location subject to direct vibration or impact
• Location exposed to direct sunlight
• Location where the product may come in contact with water, oil or chemical droplets
• Environment that blocks the air vent [Refer to Installation and Noise Elimination]
When using the product in any of the locations specified below, provide a sufficient shield.
• Location subject to electrostatic noise
• Location where high electrical or magnetic field is present
• Location with the mains or power lines passing nearby
2. Storage and Preservation Environment
The storage and preservation environment should comply with the same standards as those for the
installation environment.
In particular, when the machine is to be stored for a long time, pay close attention to environmental
conditions so that no condensation forms. Unless specially specified, moisture absorbency protection is not
included in the package when the machine is delivered. In the case that the machine is to be stored and
preserved in an environment where condensation is anticipated, take the condensation preventive
measures from outside of the entire package, or directly after opening the package.
Installation and Noise Elimination
1. Noise Elimination Grounding (Frame Ground)
2. Precautions regarding wiring method
1) Wire is to be twisted for the 24V DC power supply.
2) Separate the signal and encoder lines from the power
supply and power lines.
3. Noise Sources and Elimination
Carry out noise elimination measures for electrical devices
on the same power path and in the same equipment.
The following are examples of measures to eliminate noise
sources.
1) AC solenoid valves, magnet switches and relays
[Measure] Install a Surge absorber parallel with the coil.
2) DC solenoid valves, magnet switches and relays
[Measure] Consider whether to attach a diode in parallel
to the coil or to use a diode built-in type.
4. Cooling Factors and Installation
Follow the specifications and dimensions shown below when you design and build a control board.
Item Specification Item Specification
Installation
Orientation
Vertical Orientation
(Air outlet upwards)
Surrounding Air
Temperature
0 to 55°C
Installation
Method Attached on DIN Rails
Installation
Condition See figure below Grounding Class D grounding
Connection to Peripheral Devices (Overall Wiring Diagram)
External Dimensions
Do not share the ground wire with or connect
to other equipment. Ground each controller.
Controller
Other
equipment
Controller
Other
equipment
Other
equipment
Surge absorber
Relay
coil
Relay coil
R
C
+24V 0V
+24V 0V
+-
T RUN LED
SYS LED
Brake release switch (1 to 4 axis)
Model Plate
(Large)
Adhered
Position
Model Plate
(Large)
Adhered
Position
Field Network
(Cables to be prepared
by customer)
USB Cable
(Cables to be
prepared by
customer)
Power Supply Cable
(Cables to be prepared by
customer)
* Use cable with diameter
large enough to accept
current.
EC Connection Unit Cable
Standard Connector Model Code:
CB-REC-PWBIO□□□(-RB)
Four-Way Connector Model Code:
CB-REC2-PWBIO□□□(-RB)
ELECYLINDER
PC
TB-02/TB-03
(to be purchased
separately)
PSA-24
Master Unit
(Cables to be prepared
by customer)
PC Software
(to be purchase
d
separately)
Connector for EC Connection (1st axis)
Connector for EC Connection (2nd axis)
Connector for EC Connection (3rd axis)
Connector for EC Connection (4th axis)
Backward End LED
(1 to 4 axis)
JOG Switch (1 to 4 axis)
Forward End LED
(1 to 4 axis)
Drive Source Cutoff Connector
(N=4)

Master Unit Slave Devices REC CC-Link IE Field T
yp
e
Ethernet Straight Cable Category 5e or more
Double shielded cable braided with aluminum foil recommended
(
Note
)
Terminal resistance is not re
q
uired
There is no
distinction of IN/OUT
on the connector.
Rear Side (Link)
Link Upper Parts
Operation Part
[C]
[A]
Link Bottom Parts Operation Part
[B]
Connector
Panel Side (Unlink)
Panel Side
(Unlink)
Rear Side (Link)
Power Supply and Stop Circuit (Example)
In the diagram below shows a circuit related to REC system drive source cutoff. For REC system, 24V power is supplied
from the EC Gateway Unit, but the circuit related to the drive-source cutoff is on the EC Connection Unit side.
•
Each unit of EC Connection Unit possesses a drive cutoff circuit by semiconductor gathered for the four axes, and
the motor power source is to be cut off by the stop switch on the teaching pendant. Also, the drive source cutoff
circuit by semiconductor possesses features to detect the over current and to limit the in-rush current.
•
Each driver unit possesses an interface (Drive source cutoff connector: MPI/MPO) available for external drive
source cutoff prepared for each axis.
Note 1 If nothing is connected to the SIO connector, short-circuit should be made inside the controller.
Note ●When externally shutting off the motor drive source, connect a contact such as a relay to the wiring between the
MPI* and MPO* terminals.
●When supplying power by turning ON/OFF 24 VDC, leave 0 V connected and supply/cut off +24 V.
●Make sure to have the right cable diameter and length that would not have the voltage dropped at the wiring of the
drive cutoff connector.
●There may be a case of an alarm being generated because of the voltage drop at the controller power supply due to
inappropriate cable diameter or length. In such a case, adjust the output voltage of the power supply to keep 24V for
the supply to the controller.
Warning : Note that the stop switch on the teaching pendant cannot have a stop for the system side even though it
can have a stop for all the actuators connected to REC System.
Current Amperage
The current amperage should be divided into the control power capacity and motor power capacity.
Each power supply should be input from the 24V power supply connector on the EC Gateway Unit.
The necessary capacity of the current amperage should be figured out by [Total of control power capacity of
used units] + [Total of motor power capacity of used actuators].
It is necessary that the rated current of 24V power supply satisfies the rated current of the motor power
capacity and the peak current satisfies the maximum current of the motor power capacity. However, when
several axes get connected, unless all the actuators operates at the same time, the rated current and
maximum current would not flow at the same time, thus the calculation should not be simply the total of all
the axes.
The specifications related to the power capacities should be as shown below.
Note When ELECYLINDER * 4 axes are connected to EC Connection Unit
Restrictions in Unit Connection
(1) Number of EC Connection Units to Connect
The maximum number of control axes to be connected to one EC Gateway Unit should be 16 axes.
From the structural perspective of the unit, it can accept connection without any upper limit, but make it
accept 4 units (for 16 axes) of EC Connection Units at the maximum. (One unit occupies domains and
axis numbers for four axes regardless of whether to connect ELECYLINDER to the units or not.)
Have
two EC Gateway Units or more in the construction when it is necessary to control 17 axes or more of actuators.
(2) Current Restrictions
Shown below is the restricting values of current for selecting calculation.
Item
Restricting Value of Current for Selecting Calculation
Control Power Supply (CP) 9.0A or less
Motor Power Supply (MP) 37.5A or less
Shown below is some examples for calculation.
[Control Power Supply] * EC Gateway Unit should be excluded from the target for calculation.
When ELECYLINDER × 16 axes: EC Connection Unit 0.1A × 4 = 0.4A ⇒ OK
[Motor Power Supply]
When ELECYLINDER (with power-saving setting inactivated) × 16 axes:
EC Connection Unit Rated Current 2.3A × 16 axes = 36.8A => OK
Note For the models with no description of the rated current for the motor current amperage, calculate with the
maximum current.
Note When the operation pattern is to have all the axes operate acceleration and deceleration only and the operation
duty is 100%, it is necessary that the calculation is done with the maximum current for the motor power supply.
REC system is capable to link 4 units (for 16 axes) at the maximum with the EC Gateway Unit allocated at
the left end as the interface for the field network connection and freely construct with combination of
multiple EC Connection Units. There is an order of allocation for each unit.
EC Gateway Unit (Left End)-EC Connection Unit (
No Order among
)-REC Terminal Unit (Right End)
Each unit should be linked in the process shown below. (Make sure it gets linked before connected to the DIN rails.)
1) Twist the operation parts of the link upper parts and the link bottom parts towards the panel side and
place them at the panel side end.
2) Adjust the position of two units so the link upper parts come to Point [A], link bottom parts to [B] and the
four positioning bosses to [C] and all the six points fit to each other.
3) Once positioning is done, firmly insert the connectors at two points.
4) Twist the operation parts of the link upper parts and the link bottom parts towards the rear side till they
make click feeling.
Field Network Wirings and Settings
The field network connector is allocated on the top of the EC Gateway Unit. Refer to “Names for Each Part”.
1. CC-Link (REC-GW-CC)
Refer to the instruction manuals for each field network master unit for the details.
Connector
Name CC-Link Connector Remarks
Cable Side
MSTB2.5/5-STF-5.08 AU
(Manufactured by
PHOENIX CONTACT)
Enclosed in
standard
package
Controller Side
MSTB2.5/5-GF-5.08 AU
(Manufactured by
PHOENIX CONTACT)
Pin No. Signal Name
(Color) Description Applicable
cable diamete
r
1 DA (BL) Communication Line
A
Dedicated
cable for CC-
Link
2 DB (WT) Communication Line B
3 DG (YW) Digital Ground
4 SLD
Connect the shield of the shielded cable
(Connected inside to 5-pin FG and control power supply
connector 1-pin FG
)
5 FG
Frame Ground
(Connected inside to 4-pin SLD and control power supply
connector 1-pin FG
)
2. CC-Link IE Field (REC-GW-CIE)
Refer to the instruction manuals for each field network master unit for the details.
Connector Name CC-Link IE Field Connector Remarks
Cable Side
Ethernet ANSI/TIA/EIA-568-B Category 5e
and above 8P8C modular plug equipped
with shield (RJ45)
Please prepare
separately
Controller Side
Ethernet ANSI/TIA/EIA-568-B Category 5e
and above 8P8C modular Jack equipped
with shield (RJ45)
Pin
No. Signal Name Description Applicable cable
diamete
r
1 TP0+ Data 0+
It is recommended
to prepare a
straight STP cable
in Category 5e or
above for the
Ethernet cable.
2 TP0- Data 0-
3 TP1+ Data 1+
4 TP2+ Data 2+
5 TP2- Data 2-
6 TP1- Data 1-
7 TP3+ Data 3+
8 TP3- Data 3-
3. DeviceNet (REC-GW-DV)
Refer to the instruction manuals for each field network master unit for the details.
Connector
Name DeviceNet Connector Remarks
Cable Side
MSTB2.5/5-STF-5.08 AU M
(Manufactured
by PHOENIX CONTACT)
Enclosed in
standard
package
Controller
Side
MSTB2.5/5-GF-5.08 AU
(Manufactured
by PHOENIX CONTACT)
Pin No. Signal Name
(Color) Description Applicable
cable diameter
1 V- (BK) Power Supply Cable Negative Side
Dedicated
cable for
DeviceNet
2 CAN L (BL) Communication Data Low Side
3 - Shield
4 CAN H (WT) Communication Data High Side
5 V+ (RD) Power Supply Cable Positive Side
Item Specification
Power Supply Voltage 24V DC ±10%
Control Power Capacity
(for one unit)
EC Gateway Unit 0.8A
EC Connection Unit 0.1A
Motor power capacity
(1 axis per actuator)
Motor type Rated Current Max. current
35P/42P/56P
When power-saving
setting inactivated
2.3A 3.9A
When power-saving
setting activated
- 2.2A
28P S3□/RR3□Type - 2.2A
Slim and Small Type - 2.0A
In-Rush Current (Note) 40A
(with in-rush current limiting circuit)
Linking Units
Top View of
Connector on
EC Gateway
Unit side
L.ER
LINK
L.ER
LINK
Shield
BL (CAN L)
RD (V+)
WT (CAN H)
BK (V-)
WT (DB)
BL (DA)
Shield (SLD)
YW (DG)
REC Gateway Unit
Control
Power
Stop Switch on
Teaching Pendant
EC Motor Power SupplyⅠ
EC Motor Power SupplyⅡ
EC Motor Power SupplyⅢ
EC Motor Power SupplyⅣ
High-Side Protect ion Circuit
Drive Source
Cutoff
Connector
RCON-EC Unit
Note 1
SIO Connector
24V Input
Connector
Slave Devices
REC-
CC-Link
Type
SLD and FG are internally connected.
Terminal Resistance is required
to be mounted on the terminal.
The terminal resistor differs depending on the type
of the dedicated cable for CC-Link.
• Cable FANC-SBH···130
Ω
1/2W
(High Performance Cable
dedicated for CC-Link)
• Cable FANC-SB······110
Ω
1/2W
(CC-Link Dedicated Cable)
Master Unit Terminal
Resistance
Terminal
Resistance
Grounding resistance at 100
Ω
or less
(Class D grounding)
5
4
3
2
1
To p Vi ew o f
Connector on
EC Gateway
Unit side
5
4
3
2
1
To p Vie w o f
Connector on
EC Gateway
Unit side
Slave Devices
REC-DeviceNet Type
V+
Drain
(Shield)
CAN_H
CAN_L
V-
RD
W
T
BL
BK
RD
WT
BL
BK
V+
Drain
(Shield)
CAN_H
CAN_L
Grounding resistance at 100
Ω
or less
(Class D grounding)
V+
Drain
(Shield)
CAN_H
CAN_L
V-
RD
WT
BL
BK
Communication power needs to be
supplied by an external device.
Terminal Resistance is required
to be mounted on the terminal.
V-
Terminal Resistance
121
Ω
Master Unit
Terminal Resistance
121Ω
24V
Power Supply

4. EtherCAT (REC-GW-EC)
Refer to the instruction manuals for each field network master unit for the details.
Connector Name EtherCA
T
Connecto
r
Remarks
Cable Side
Ethernet ANSI/TIA/EIA-568-B Category 5
and above 8P8C modular plug equipped
with shield (RJ45)
Please prepare
separately
Controller Side
Ethernet ANSI/TIA/EIA-568-B Category 5
and above 8P8C modular Jack equipped
with shield (RJ45)
Pin
No. Signal Name Description Applicable cable
diameter
1 TD+ Data sending+
It is recommended
to prepare a
straight STP cable
in Category 5 or
above for the
Ethernet cable.
2 TD- Data sending-
3 RD+ Data receiving+
4 - Disconnected
5 - Disconnected
6 RD- Data receiving-
7 - Disconnected
8 - Disconnected
5. EtherNet/IP (REC-GW-EP)
7. PROFINET IO (REC-GW-PRT)
Refer to the instruction manuals for each field network master unit for the details.
Connector Name EtherNet/I
P
, PROFINET IO Connecto
r
Remarks
Cable Side
Ethernet ANSI/TIA/EIA-568-B Category 5
and above 8P8C modular plug equipped
with shield (RJ45)
Please prepare
separately
Controller Side
Ethernet ANSI/TIA/EIA-568-B Category 5
and above 8P8C modular Jack equipped
with shield (RJ45)
Pin
No. Signal Name Description Applicable cable
diameter
1 TD+ Data sending+
It is recommended
to prepare a
straight STP cable
in Category 5 or
above for the
Ethernet cable.
2 TD- Data sending-
3 RD+ Data receiving+
4 - Disconnected
5 - Disconnected
6 RD- Data receiving-
7 - Disconnected
8 - Disconnected
6. PROFIBUS-DP (REC-GW-PR)
Refer to the instruction manuals for each field network master unit for the details.
Connector Name PROFIBUS-DP Connector Remarks
Cable Side 9-pin D-sub Connector (Male) Please prepare separately
Controller Side 9-pin D-sub Connector (Female)
Pin
No. Signal Name Description Applicable cable diameter
1 NC Disconnected
Dedicated cable for
PROFIBUS-DP
(Type A: EN5017)
2 NC Disconnected
3 B-Line Communication Line B (RS485)
4 RTS Request for Sending
5 GND Signal GND (Insulation)
6 +5V +5V Output (Insulation)
7 NC Disconnected
8 A-Line Communication Line A (RS485)
9 NC Disconnected
Starting Procedures
When using this product for the first time, make sure to avoid mistakes and incorrect wiring by referring to
the procedure below.
In this section, explains how to start up especially for REC system. Follow an instruction manual (DVD) for
each device for how to link to other devices, controllers and actuators that are linked in the network.
Troubleshooting (LED Display)
On REC Gateway Unit, there are the monitor LEDs for the field network and communication.
You can confirm the communication establishment and also communication errors on these LEDs.
Refer to “Names for Each Part” for the position and name of each LED lamp.
1. LED Display on EC Gateway Unit
Panel
Display Color Status Explanation
T RUN GN Illuminating Inside bus communication in normal conditions
Flashing Waiting for initializing communication
OR Illuminating Inside bus communication in error
SYS GN Illuminating Operating in normal conditions
OR Illuminating Gateway alarm being generated
STOP RD Illuminating
Stop switch on teaching pendant valid (while pressed and held)
OFF Stop switch on teaching pendant invalid
MODE GN Illuminating In AUTO (automatic operation) Mode
OFF In MANU (manual operation) Mode
C ERR OR Illuminating Error occurred in field network
OFF Field network operating in normal conditions
STATUS 0 - - Differs depending on field network (Refer to Field Network
Communication Conditions from 1 to 7)
STATUS 1 - - Differs depending on field network (Refer to Field Network
Communication Conditions from 1 to 7)
2. LED Display on EC Connection Unit
Panel
Display Color Status Explanation
T RUN GN
Illuminating Inside bus communication in normal conditions
Flashing Waiting for initializing communication, Initializing
communication failed
OR Illuminating Inside bus communication in error
SYS
GN Illuminating Servo ON
OFF Servo OFF
RD Illuminating Alarm being generated, stop switch on teaching pendant
valid (while pressed and held)
Forward
End
GN Illuminating Movement to forward end completed
OFF Stop
RD Illuminating Alarm being generated
Backward
End GN Illuminating Movement to backward end completed
OFF Stop
[Field Network Communication Conditions]
1. CC-Link (REC-GW-CC)
Name Panel
Display Color Status Explanation
STATUS 0 RUN GN
Illuminating
Succeeded in refresh and polling reception
after getting into network, or succeeded in
refresh reception
OFF
1. Not in network
2. Carrier detected for channel
3. Timeover
4. In hardware reset
STATUS 1 ERR OR
Illuminating
1. CRC Error
2. Station number setting error at reset release
(65 stations or more including 0 or occupied
station number)
3. Baud rate setting error at reset release
Flashing
(Flash for
0.4sec)
Numbers changed from station numbers and
baud rate setting numbers at reset release
OFF 1. Communication in normal conditions
2. In hardware reset
5 1
9 6
Cable
Shield
Red B line (Positive side)
Green A line (Negative side)
Master Unit Slave Devices REC EtherCAT Type
Ethernet Straight Cable Category 5 or more
Double shielded cable braided with aluminum foil recommended
(Note) Terminal resistance is not required
Top View of
Connector on
EC Gateway
Unit side
1
8
1
8
OUT
IN
Top View of
Connector on
EC Gateway
Unit side
1
8
59
6
1
To p Vie w o f
Connector on
EC Gateway
Unit side
Slave Devices
REC PROFIBUS-DP Typ
e
Master Unit
Grounding resistance at 100
Ω
or less
(Class D grounding)
Master Unit
Switching Hub
Slave Devices
REC-
EtherNet/IP Type
or
REC-
PROFINET IO Type
Ethernet Straight Cable,
Category 5 or more
Double shielded cable braided with
aluminum foil recommended
No →
Check on Safety Circuit
Confirm that the stop circuit (drive source cutoff circuit) works in normal conditions.
↓Yes
No →
Check of Packed Items
Are all the delivered items present? Contact your local IAI distributor
Installation and Wiring
* Refer to [Installation and Noise Elimination] in this first step guide
Install the controller and actuator and perform wiring according.
Important Check Item
• Is frame ground (FG) connected?
• Has the noise countermeasure been taken?
↓
← Yes
Initial Settings (Setup of ELECYLINDER) * Teaching Tool is required
Establish the parameter settings for each ELECYLINDER.
PLC (Master Unit) Baud Rate * Refer to PLC Instruction Manual.
Have the settings established for the PLC node addresses (station
numbers) and the baud rate.
Initial Settings (Setup of Gateway) * Gateway parameter setting tool is required
Have the settings done for the axis number setting, mode settings, field network communication speed, node addresses
(station numbers) and so on to suit to the system.
↓
No →
Power Supply
1) Supply the power to PLC (master unit). 2) Supply the power to REC.
Check the status of LED lamps to see the
cause of the error to have an appropriate
counteraction. Do the whole process from
the start if the cause of the error is not
clear.
↓
Communication Establishment Check
• Confirm that the communication has been established with the
LED lamp on EC Gateway Unit.
* Refer to “Troubleshooting” in this first step guide
•
Confirm that communication is established also on PLC (master unit).
* Refer to PLC Instruction Manual.
Check the circuit.
↓Yes
Now, it is succeeded to establish communication and ready for operation.
Move on to the system operation check and adjustment.
↓
Assembling REC (Linking up Units)
Join the units to use such as the EC Gateway Unit, EC Connection Unit and REC Terminal Unit.
↓
↓
Important Check Item
• Is the control sequence applicable for
the continuous mode and the system?
↓Yes

2. CC-Link IE Field (REC-GW-CIE)
Name Panel
Display Color Status Explanation
STATUS 0 MS
GN Illuminating Operation in normal conditions
OFF Hardware error occurred
OR Illuminating Error being occurred
OFF Operation in normal conditions
STATUS 1 NS
GN
Illuminating Cyclic transmission in process
Flashing Cyclic transmission paused
OFF Cyclic transmission not conducted, parallel off
OR Illuminating Received data in error
OFF Received data in normal conditions
LINK - GN Illuminating Linkup in process
OFF Link-down in process
L.ER - OR Illuminating Received data in error
OFF Received data in normal conditions
3. DeviceNet (REC-GW-DV)
Name Panel
Display Color Status Explanation
STATUS 0 MS
GN
Illuminating Operation in normal conditions
Flashing (1Hz) There is no configuration information, or not
complete, device trial run necessary
OR Illuminating Malfunction with no opportunity for recovery
Flashing (1Hz) Malfunction with opportunity for recovery
GN/OR Illuminated by
turns Self‐diagnosis
STATUS 1 NS
GN Illuminating Online, Connection established
Flashing (1Hz) Online, No connection established
OR Illuminating Critical Error
Flashing (1Hz) Connection Timeout
GN/OR
Illuminated by
turns Self‐diagnosis
OFF Offline
4. EtherCAT (REC-GW-EC)
Name Panel
Display Color Status Explanation
STATUS 0 ERR OR
Illuminating Communication component (module) error
Flashing
(continuously)
Construction information (setting) error
ON: 200ms / OFF: 200ms
Flashing
(twice)
Communication part circuit error
ON: 200ms × 2 / OFF: 1000ms
OFF In initializing process
STATUS 1 RUN GN
Illuminating In normal operation (OPERATION)
Flashing
(continuously)
In PRE-OPERATION condition
ON: 200ms / OFF: 200ms
Flashing
(once)
In SAFE-OPERATION condition
ON: 200ms / OFF: 1000ms
OR Flashing Communication component (module) error
5. EtherNet/IP (REC-GW-EP)
Name Panel
Display Color Status Explanation
STATUS 0 MS
GN
Illuminating Operation in normal conditions
Flashing There is no configuration information,
or scanner in idol condition
OR Illuminating Malfunction with no opportunity for recovery
Flashing Malfunction with opportunity for recovery
STATUS 1 NS
GN Illuminating Online, connection established
Flashing Online, No connection established
OR Illuminating Critical error, IP address duplicated error
Flashing Connection Timeout
GN/OR OFF No IP address
6. PROFIBUS-DP (REC-GW-PR)
Name Panel
Display Color Status Explanation
STATUS 0 MS
GN
Illuminating Initialization completed
Flashing Initialization completed, there is a diagnosis
event
OR Illuminating Exception error
GN/OR OFF Not initialized
STATUS 1 NS
GN Illuminating Online, data exchange
Flashing Online, cleared
OR Illuminating Parameter error
Flashing Configuration error
GN/OR OFF Offline
7. PROFINET IO(REC-GW-PRT)
Name Panel
Display Color Status Explanation
STATUS 0 MS
GN
Illuminating Communication in normal conditions
Flashing (once) In network diagnosis
Flashing (twice) Engineering tools identifying nodes
OR
Illuminating Exception error occurred (malfunction of
hardware)
Flashing (once) Mismatch of setting an actual network
construction
Flashing (twice) IP address not established
Flashing
(three times) Station name not established
Flashing
(four times) Internal error occurred
GN/OR OFF In initializing process
STATUS 1 NS GN Illuminating Online (communication in normal conditions:
RUN)
Flashing Online (STOP)
GN/OR OFF No connection
Head Office: 577-1 Obane Shimizu-KU Shizuoka City Shizuoka 424-0103, Japan
TEL +81-54-364-5105 FAX +81-54-364-2589
website: www.iai-robot.co.jp/
Ober der Röth 4, D-65824 Schwalbach am Taunus, Germany
TEL 06196-88950 FAX 06196-889524
SHANGHAI JIAHUA BUSINESS CENTER A8-303, 808, Hongqiao Rd. Shanghai 200030, China
TEL 021-6448-4753 FAX 021-6448-3992
website: www.iai-robot.com
Technical Support available in USA, Europe and China
Head Office: 2690 W. 237th Street, Torrance, CA 90505
TEL (310) 891-6015 FAX (310) 891-0815
Chicago Office: 110 East State Parkway, Schaumburg, IL 60173
TEL(847) 908-1400 FAX (847) 908-1399
TEL (678) 354-9470 FAX (678) 354-9471
website: www.intelligentactuator.com
Atlanta Office: 1220 Kennestone Circle, Suite 108, Marietta, GA 30066
825 PhairojKijja Tower 7th Floor, Debaratana RD., Bangna-Nuea, Bangna, Bangkok 10260, Thailand
TEL +66-2-361-4458 FAX +66-2-361-4456
website:www.iai-gmbh.de
website:www.iai-robot.co.th
Manual No.: ME0395-1B
This manual suits for next models
2