IBEST TCL SERIES User manual

TCL-R1□P
TCL-S1□P
TCL-K1□P
TCL-R1□J
TCL-S1□J
TCL-K1□J
P1www.ibestchina.com
%(67
Electrical & Automation
Digital Temperature Controller User Manual
IBEST ELECTRICAL CO.,LTD
TCL SERIES
Dear Clients: Thanks for choosing IBEST TCL SERIES temperature controller. Before installing and operating
it, please read this instruction manual carefully. For any questions, please contact our sales or technical people
immediately.
1.FEATURES
●ǂPID temperature controller or ON/OFF control; built with SMT technology
● Auto tune function, fuzzy PID.
●ǂDual line 3 LED digit display: upper LED: red; lower LED: green
● Soft buttons, easily operate
● Optional input signals: thermocouple: K, E, J; thermo resistance: Pt100;
● Optional control output: Relay,SSR,SCR output.
● Alarm output: 1 high alarm
● Measuring accuracy: ˖≤±0.5%F.S±1 digit (under normal conditions)
● Optional instrument size: 48W×48H;48W×96H;72W×72H;96W×48H;96W×96H.(mm)
● Apllication ranges: food&beverage; oven, furnance, plastic extruder, chemicals processing, heating
process...etc.(For temperature measuring and control)
2.ORDERING CODE
T C L R 1 4 K
R
Temperatrue controller
L series
S
K
Relay control output
Ssr control output
Scr control output
4
6
7
8
9
K
P
One alarm
K,E,J,thermocouple input
Pt100 thermo resistance input
48W×48H dimension
48W×96H dimension
72W×72H dimension
96W×48H dimension
96W×96H dimension
3.MODE
TCL-R1□K
TCL-S1□K
TCL-K1□K
TCL-R1□E
TCL-S1□E
TCL-K1□E
MODE CONTROL OUTPUT
Relay
Ssr
Scr
ALARM
One
One
One
Notice: Input signals ---K: k thermocouple; E: E thermocouple; J: J thermocouple ;P: Pt100 thermo resistance
4.TECHNICAL SPECIFICATIONS
INPUT TYPE
K
Thermocouple E
J
Pt100
Thermo resistance
0~800ć
0~600ć
0~800ć
0~99.9ćor -200~800 ć
CONTROL OUTPUT
Relay
Ssr
Scr
240V AC /3A
MEASURING ACCURACY 0.5%±1digit
CONTRON TYPE ON/OFF control / PI control / fuzzy PID
E J

TCL SERIES
temperature controller
,%(67嘐
%(67
Electrical & Automation
IBEST ELECTRICAL CO.,LTD
Digital Temperature ControllerUser Manual TCL SERIES
P
2
www.ibestchina.com
0~50ć45~85RH%/86~106KPa
OPERATION CONDITION
POWER SUPPLY
DIMENSIONS
INSULATION STRENGTH AC 1500V 1 min / DC500V ı50MΩ
AC 110V/220V ( * The dimenson 48W×48H is 85~260V AC )
4:48W×48H / 6:48W×96H/ 7:72W×72H/ 8:96W×48H/9:96W×96H
5.PANEL ILLUSTRATION
PV (Red LED)
ǂ●ǂdisplay measuring value
ǂ●ǂdisplay parameters
SV(Green LED)
ǂ●ǂdisplay set value
ǂ●ǂdisplay parameters value
AT lamp
green: auto-tune; flash: output
OUT lamp
green (on): control output;
Off: no output
ALM lamp
red(on) alarm output:
off: no alarm output
Increase key Decrease key
Function key
parameters set and confirm key
6.OPERATION ILLUSTRATION
Inp
K
80
180
999
000
Input
Input type: display the input type you ordered
Measuring value upper limit
Measuring value lower limit
Measuring value
Set point
Power on
A.Funcition adjustment
Enter into measuring status
Set temperature
Press“ ” key, the upper LED display “SP”; lower LED display set value , press “ ” or “ ” to modify the value you
need.Then confirm the value by press“ ” key again.
Control parameters
Press“ ”key for 5 seconds,the upper LED display the control parameters, the lower LED display the
parameters value.To modify the parameters value,please press “ ”and “ ” key. Press “ ” key to
confirm the value modified and then press “ ” to shift to the next parameter . If you want to escape the
control paraneters menu, please press “ ” key for 5 seconds; or no operation whithin 1 minutes also let
the lontroller go back to measuring estate. The parameters list ,please refer to page “T 3”
Auto-tune function
Press “ ” for 20 seconds ,“AT” Lamp flash, the instrument begins Auto-tune . when the unit goes through
1 or 2 temperature waves, “AT” lamp goes out, Auto-tune finishes. Please keep the parameter value for
future reference.
Notice
The red LED lower display “000”, it means the thermocouple wire was wrongly connected; If the red LED
upper display “000”, it means thermocouple open circuit or the temperature suppressed the measuring
scale.

P3www.ibestchina.com
%(67
Electrical & Automation
Digital Temperature ControllerUser Manual
IBEST ELECTRICAL CO.,LTD
TCL SERIES
B.Parameter list
Alarm output: AL˚0 is high alarm
AL˘0 is low alarm ,rel alarm point: SP+AL
PARAMETER NAME SETTING
RANGE
SPECIFICATIONS FACTORY
SETTING
AL
rt
Ar
P
T
Cr
Lc
Alarm
Measuring
valve correction
-200~800ć50
-100~100ć
0~100ć
0~400ć
1~1006HF
1~999
0~2
0
100
30
20/3
240
0
Correct the measuring deviation caused
by the thermocouple and compensation cable
LC=0 All parameters can read and write
LC=1 Only “SP” value can read and write others can only read
LC=2 All parameters can read on
Proportion band
Control Cycle Relay˚20Sec
External solid state relay or ssr controller,T=3Sec
Password setting
System constant
Relate the heating equipment’s capacity,temperature
increase time,thermocoule position, proportion band
...etc. usually for big inertial objects,cr should be
bigger; When P≠0, Cr=0 is time proportion control
7.DIMENSION AND INSTALLATION HOLE DIMENSION( unit: mm)
W
H D
L
Ca
b
MODE
DIMENSION INSTALLATION
HOLE DIMENSION
a × b
TCL-□14□
TCL-□16□
TCL-□17□
TCL-□18□
TCL-□19□
W × H C × D × L
48 × 48
96 × 96
96 × 48
72 × 72
48 × 96
45 × 45
93 × 93
93 × 45
69 × 69
45 × 93
44 × 44 × 100
92 × 92 × 70
92 × 44 × 70
68 × 68 × 70
44 × 92× 70
8.ELECTRICAL CONNECTIONS
9$&'&
ʆ
ʆ
G
5W
ĕ
ĕ
ĕ
1&
12
5(/$<
ALM
SSR
TC
TCL-□14□
SCR
ʆ
ʆ
1&
$&9
G
5W
ĕ
ĕ
ĕ
12
5(/$<
ALM
SSR
TC
TCL-□16□, TCL-□17□, TCL-□18□, TCL-□19□
SCR
Temperature
overshoot
restrain
To decrease “Ar ” can decrease temperature over
shoot ,when “SP” is changed ,”Ar” needs to reset ;
when the value=0 ,the Ar=0.4ć
“P” is bigger ,the proportion is less function ,the
system gain is lower; if “P”is too big,the time to
reach “set point” is very long,contrarily,“P” is too
small,the temperature tends to fluctuate

%(67
Electrical & Automation
IBEST ELECTRICAL CO.,LTD
Digital Temperature ControllerUser Manual TCL SERIES
P
4
www.ibestchina.com
9.INSTRUMENT MAINTAINANCE AND STOCK
Before installing and using this instrument, please read this user manual carefully in order to operate the unit in
the appropriate conditions to avoid any damage. Keep this user manual for future reference.
● When clean the instrument, make sure the power is at “OFF” status.
● To clean out the dust or dirt on the instrument screen, please use soft cloth or cotton papper.
● Do not touch the instrument screen by hard objects to avoid scratch of the screen.
● Do not use screw driver or hard pin to touch the soft buttons on the faceplate.
● From the date of shipping, if there are any damages or fault within 18 months, the factory is bond to matain
the units. But if the danages re coused by inappropriate operation by use, the factory doesn’s.The instrunent
should be stock in the dry ,non gas environment.