IBM EXP15 Owner's manual

S10L-9839-01
EXP15, EXP200, EXP500 HMM
IBM Netfinity Storage Expansion Unit
EXP15-Type 3520, EXP200-Type 3530,
EXP500-Type 3560
Hardware Maintenance Manual
April, 2000
We Want Your Comments!
(Please see page 134)


S10L-9839-01
EXP15, EXP200, EXP500 HMM
IBM Netfinity Storage Expansion Unit
EXP15-Type 3520, EXP200-Type 3530,
EXP500-Type 3560
Hardware Maintenance Manual
April, 2000
We Want Your Comments!
(Please see page 134)
IBM

Note
Before using this information and the product it
supports, be sure to read the general information
under “Notices” on page 135.
Second Edition (October 1999)
The following paragraph does not apply to the United
Kingdom or any country where such provisions are
inconsistent with local law: INTERNATIONAL
BUSINESS MACHINES CORPORATION PROVIDES THIS
PUBLICATION “AS IS” WITHOUT WARRANTY OF ANY
KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT
NOT LIMITED TO, THE IMPLIED WARRANTIES OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE. Some states do not allow disclaimer of
express or implied warranties in certain transactions,
therefore, this statement may not apply to you.
This publication could include technical inaccuracies or
typographical errors. Changes are periodically made to
the information herein; these changes will be incorporated
in new editions of the publication. IBM may make
improvements and/or changes in the product(s) and/or the
program(s) described in this publication at any time.
This publication was developed for products and services
offered in the United States of America. IBM may not offer
the products, services, or features discussed in this
document in other countries, and the information is subject
to change without notice. Consult your local IBM
representative for information on the products, services,
and features available in your area.
Requests for technical information about IBM products
should be made to your IBM reseller or IBM marketing
representative.
Copyright International Business Machines
Corporation 1998, 1999, 2000. All rights reserved.
Note to U.S. Government users–Documentation related to
Restricted rights–Use, duplication, or disclosure is subject
to restrictions set forth in GSA ADP Schedule Contract
with IBM Corp.
ii IBM Netfinity EXP15, EXP200, EXP500 HMM

About This Manual
Note
This manual should be used with the Hardware
Maintenance Manual for the system you are servicing.
This manual contains Symptom-to-FRU Index, service
information, and configuration information for following IBM
Netfinity Storage Expansion Units:
EXP15 - Type 3520 (Model 2RU, 2RX)
EXP200 - Type 3530 (Model 1RU, 1RX)
EXP500 - Type 3560 (Model 1RU)
Important
This manual is intended for trained servicers who are
familiar with IBM PC/Netfinity Server products.
Important Safety Information
Be sure to read all caution and danger statements in this
book before performing any of the instructions.
Leia todas as instruções de cuidado e perigo antes de
executar qualquer operação.
iii

Prenez connaissance de toutes les consignes de type
Attention et
Danger avant de procéder aux opérations décrites par les
instructions.
Lesen Sie alle Sicherheitshinweise, bevor Sie eine
Anweisung ausführen.
Accertarsi di leggere tutti gli avvisi di attenzione e di
pericolo prima di effettuare qualsiasi operazione.
Lea atentamente todas las declaraciones de precaución y
peligro ante
de llevar a cabo cualquier operación.
Online Support
Use the World Wide Web (WWW) to download Diagnostic,
BIOS Flash, and Device Driver files.
File download address is:
http://www.pc.ibm.com/us/files.html
IBM Online Addresses:
The IBM Support Page is:
http:///www.pc.ibm.com/support/
The IBM Personal computing solutions page is:
http://www.pc.ibm.com
iv IBM Netfinity EXP15, EXP200, EXP500 HMM

Contents
About This Manual ................ iii
Important Safety Information ............ iii
Online Support . . . . . . . . . . . . . . . . iv
Netfinity EXP15 Type 3520 ............ 1
Features . . . . . . . . . . . . . . . . . . . . . 2
Diagnostics and Test Information ......... 3
Additional Service Information ........... 4
Symptom-to-FRU Index . . . . . . . . . . . . . . 7
Locations . . . . . . . . . . . . . . . . . . . . . 9
Parts Listing . . . . . . . . . . . . . . . . . . . 22
Netfinity EXP200 Type 3530 ........... 25
Features . . . . . . . . . . . . . . . . . . . . . 26
Diagnostics and Test Information ......... 27
Additional Service Information ........... 28
Symptom-to-FRU Index . . . . . . . . . . . . . . 31
Locations . . . . . . . . . . . . . . . . . . . . . 33
Parts Listing . . . . . . . . . . . . . . . . . . . 57
Netfinity FAStT EXP500 - Type 3560 ....... 61
Features . . . . . . . . . . . . . . . . . . . . . 63
Diagnostics and Test Information ......... 64
Additional Service Information ........... 65
Symptom-to-FRU Index . . . . . . . . . . . . . . 71
Locations . . . . . . . . . . . . . . . . . . . . . 73
Parts Listing . . . . . . . . . . . . . . . . . . 108
Related Service Information .......... 111
Safety Information . . . . . . . . . . . . . . . 112
Software/Hardware Mismatch Problems ..... 132
Send Us Your Comments! ............ 134
Problem Determination Tips ........... 135
Notices . . . . . . . . . . . . . . . . . . . . . 135
Copyright IBM Corp. 1999, 2000 v

vi IBM Netfinity EXP15, EXP200, EXP500 HMM

Netfinity EXP15 Type 3520
Features . . . . . . . . . . . . . . . . . . . . . 2
Diagnostics and Test Information ......... 3
Additional Service Information ........... 4
Performing a Shutdown ............ 4
Turning the Power On ............. 4
Specifications . . . . . . . . . . . . . . . . . 5
Symptom-to-FRU Index . . . . . . . . . . . . . . 7
Locations . . . . . . . . . . . . . . . . . . . . . 9
ESM Board Controls and Indicators ....... 10
Expansion Unit Option Switches ........ 11
ESM Board Replacement ........... 12
Front Controls and Indicators .......... 12
Drive Numbering . . . . . . . . . . . . . . . . 13
Replacing Drives (Hot-Swap) .......... 14
Fan Controls and Indicators .......... 15
Replacing Fans (Hot-Swap) .......... 16
Power Supply Controls and Indicators ...... 17
Replacing Power Supplies (Hot Swap) ..... 17
Removal From Rack .............. 19
Replacing Rails . . . . . . . . . . . . . . . . 20
Parts Listing . . . . . . . . . . . . . . . . . . . 22
System . . . . . . . . . . . . . . . . . . . . 23
Power Cords . . . . . . . . . . . . . . . . . 24
Copyright IBM Corp. 1999, 2000 1

Features
Modularized Components
High-capacity hard disk drives
Environmental Services Monitor (ESM) board
Power Supplies
Cooling Fans
Technology
Supports disk array technology
SCSI (LVD or SE) host interface
Redundant data storage, cooling system, and power system.
Hot-swap technology for hard disk drives, power supplies, and
fans
Automatic recovery after power failure without user
intervention
User Interface
Built-in power, Activity, and Fault indicators
Identification labeling on Customer Replaceable Units,
(CRUs), rear indicator lights, switches and connectors
Hard Disk Drives
Supports up to ten hard disk drives
Supports 2 channels per expansion unit
Supports 5 hard disk drives per channel
ESM Board
ID numbers
–Switch controlled for hard disk drive channel numbers: 1
and 2
–Switch On –Hard Disk Drive SCSI IDs: 0, 1, 2, 3, and 4
for both Channel 1 and Channel 2.
–Switch Off (default) –Hard Disk Drive SCSI IDs: 0, 1, 2,
3, 4, 8, 9, 10, 11, and 12 for Channel 1 or Channel 2.
Technology and Interfaces
–Model: SCSI, LVD, or single-ended
–SCSI bus interface: Two, 68-pin, VHDCI connectors for
incoming and outgoing SCSI bus cables
2IBM Netfinity EXP15, EXP200, EXP500 HMM

Diagnostics and Test Information
Important
The service procedures are designed to help you
isolate problems. They are written with the
assumption that you have model-specific training on
all computers, or that you are familiar with the
computers, functions, terminology, and service-related
information provided in this manual and the
appropriate IBM PC/Netfinity Server Hardware
Maintenance Manual.
The following is a list of problems and references for
diagnosing the IBM Netfinity EXP15 Storage Expansion
Unit - Type 3520.
Problem Reference
Hard Disk Drive Numbering See “Drive Numbering”on
page 13.
Error Codes/Error Messages Refer to the
Symptom-to-FRU Index for
the server that the Storage
Expansion Unit you are
servicing is connected to.
Expansion Unit Options
Switches
See “Expansion Unit Option
Switches”on page 11.
Fan Controls and
Indications
See “Fan Controls and
Indicators”on page 15.
Front Controls and
Indications
See “Front Controls and
Indicators”on page 12.
Performing a Shutdown See “Performing a
Shutdown”on page 4.
Power Supply Controls and
Indicators
See “Power Supply Controls
and Indicators”on page 17.
Rear Controls and
Indications
See “ESM Board Controls
and Indicators”on page 10.
Turning the Power On See “Turning the Power On”
on page 4.
Netfinity EXP15 Type 3520 3

Additional Service Information
“Performing a Shutdown”
“Turning the Power On”
Performing a Shutdown
Note
If the Expansion Unit loses power unexpectedly, it
might be due to a hardware failure in the power
system or mid-plane (see “Symptom-to-FRU Index”on
page 7).
To perform a shutdown:
1. Make sure that all I/O activity has stopped. If
applicable, logically disconnect from the host
controller.
2. Make sure that all amber Fault LEDs are off. If any
Fault LEDs are lit (drives, power supplies, or fans),
correct the problem before you turn off the power.
3. Turn off both power supply switches on the back of
the expansion unit.
Turning the Power On
Use this procedure to power-on the Netfinity EXP15
Storage Expansion unit.
Initial start-up:
1. Verify that all communication and power cables
are plugged into the back of the expansion unit.
a. All hard disk drives are locked securely in
place.
b. The Option ID switch on the expansion unit
is set correctly.
c. The host controller and other SCSI bus
devices are ready for the initial power-up.
d. Power-on the expansion unit before
powering on the server.
2. Turn on the power to each device, based on this
power-up sequence.
3. Turn on both power supply switches on the back
of the expansion unit.
4. Only the green LEDs on the front and back
should be on. If one or more of the amber Fault
LEDs are on, refer to “Symptom-to-FRU Index”
on page 7.
Re-starting:
If you are re-starting after a normal shutdown, wait at
least ten seconds before you attempt to turn on either
power supply switch.
4IBM Netfinity EXP15, EXP200, EXP500 HMM

Specifications
Size
With front panel:
–Depth: 57.9 cm (22.8 in.)
–Height: 13.2 cm (5.20 in.)
–Width: 48.2 mm (18.97 in.)
Weight
Typical expansion unit as shipped: 39 kg (86 lb)
Electrical Input
Sign-wave input (50 to 60 Hz)
–Low range:
Minimum: 90 V ac
Maximum: 127 V ac
–High range:
Minimum: 198 V ac
Maximum: 257 V ac
Input Kilovolt-amperes (kVA) approximately:
–Minimum configuration:
0.06 kVA
–Maximum configuration:
0.39 kVA
Environment
Air Flow: Air flow is from front to back
Air temperature:
–expansion unit on:
10°to 35°C
(50°to 95°F)
Altitude: 0 to 914 m (3000 ft.)
–expansion unit on:
10°to 32°C
(50°to 90°F)
Altitude: 914 m (3000 ft.) to 2133 m (7000 ft.)
Humidity:
–10% to 80%
Heat Output
Approximate heat output in British Thermal Units
(BTU) per hour:
–Minimum configuration: 205.2 BTU (60 watts)
–Maximum configuration: 1333.8 BTU (390 watts)
Acoustical Noise Emissions Values
For open bay (0 drives installed) and typical system
configurations (8 hard drives installed).
Sound Power (idling):
–6.2 bels (open bay)
–6.4 bels (typical)
Sound Power (operating):
–6.2 bels (open bay)
–6.5 bels (typical)
Sound Pressure (idling):
Netfinity EXP15 Type 3520 5

–47 dBA (open bay)
–49 dBA (typical)
Sound Pressure (operating):
–47 dBA (open bay)
–50 dBA (typical)
These levels are measured in controlled acoustical
environments according to ISO 7779 and are reported in
accordance with ISO 9296. The declared sound power
levels indicate an upper limit, below which a large portion
of machines operate. Sound pressure levels in your
location might exceed the average 1-meter values stated
because of room reflections and other nearby noise.
6IBM Netfinity EXP15, EXP200, EXP500 HMM

Symptom-to-FRU Index
Use this chart to find solutions to problems that have
definite symptoms.
Problem Indicator FRU/Action
Amber LED On
(Front Panel)
1. Hard Disk Drive
Amber and Green LED
Flashing
(Front Panel)
1. Host issued a drive
rebuild command
Amber LED On 1. Fan
Amber LED On
(ESM Board)
1. ESM board
2. Check for fan fault
LED
3. Unit is overheating.
Check temperature.
Amber LED On, Green LED
Off
1. Turn Power Switch
On
2. Power cord
3. Reseat Power Supply
4. Power Supply
Amber and Green LEDs On 1. Power Supply
Amber and Green LEDs Off 1. Reseat hard disk
drive
2. Hard Disk Drive
All Green LEDs Off 1. Check AC voltage
cabinet AC voltage
line inputs.
2. Power Supplies
3. Mid-plane board
Intermittent power loss to
expansion unit
1. Check AC voltage
line inputs, and
cabinet power
components.
2. Power Supplies
3. Mid-plane board
One or more Green LEDs
Off
1. Turn Power Switch
On
2. Power cord
3. Reseat Power Supply
4. Power Supply
One or more Green LEDs
Off
1. No activity to the
drive
2. This can be normal
activity
One or more Green LEDs
Off
(All Hard Disk Drives or
those on one Bus)
1. Use SCSI RAID
Manager to check
drive status
2. SCSI Cables
3. ESM Board
4. Mid-plane board
Netfinity EXP15 Type 3520 7

Note
If you cannot find the problem using this
Symptom-to-FRU Index, test the entire system. See
the server documentation for more detailed information
on testing and diagnostic tools.
Problem Indicator FRU/Action
Unable to access drives on
one or both SCSI buses
1. Check SCSI cables
and connections
2. Option switch 2 must
be set to off.
3. ESM board
Intermittent Power Loss 1. AC power or plug
2. Power supply
3. Mid-plane
Random errors 1. Mid-plane board
2. Make sure option
switches 1 and 2 are
set to Off.
8IBM Netfinity EXP15, EXP200, EXP500 HMM

Locations
“ESM Board Controls and Indicators”on page 10
“Expansion Unit Option Switches”on page 11
“ESM Board Replacement”on page 12
“Front Controls and Indicators”on page 12
“Drive Numbering”on page 13
“Replacing Drives (Hot-Swap)”on page 14
“Fan Controls and Indicators”on page 15
“Replacing Fans (Hot-Swap)”on page 16
“Power Supply Controls and Indicators”on page 17
“Replacing Power Supplies (Hot Swap)”on page 17
“Replacing hot-swap drives”on page 88
“Replacing Rails”on page 20
Netfinity EXP15 Type 3520 9

ESM Board Controls and Indicators
SCSI Bus 1 Connector SCSI Bus 2 Connector
Lever
Option Switches
Tray Number Switch
Term Power LEDTerm Power LED
ESM Board FRU
Lever
Over Temp LED
LVD/SE LED
LVD/SE LED Power LED
Active LED Active LED
Note
SCSI Bus Connectors are 68-pin VHDCI connectors
used for attaching SCSI cables.
ESM Board LED Indications:
LED Description
Term Power (green) LED is On if Term Power is
present, indicating that the
other end of the cable is
connected to a power-on
controller.
LVD/SE (green) LED is On if the host bus is
in LVD mode (default is
LVD mode.)
Power (green) LED is On when there is
power to the ESM board.
Over Temp (amber) This LED is On if the
expansion unit overheats.
Active (green) This LED flashes when
there is activity on the
external SCSI bus.
10 IBM Netfinity EXP15, EXP200, EXP500 HMM

Expansion Unit Option Switches
Option Switches
Tray Number Switch
0
1
2
3
4
5
6
7
8
9
The expansion unit has three types of ID numbers:
Drive SCSI IDs Identifies each drive in the
expansion unit.
Tray ID identifies each expansion unit
SAF-TE chip SCSI ID System-management SCSI
Accessed Fault Tolerant
Enclosure processor
Switch settings are as follows:
Option Switches
–Switch 1 off (default)
- Bus 1 and 2 as Single Bus 1, accessing all
ten drives, (IDs 0-4 and 8-12).
–Switch 1 on
- Bus 1 and Bus 2 accessing 5 drives each.
Bus 1 accessing IDs 0-4
Bus 2 accessing IDs 0-4
Note
Option Switches 2-5 must be set to the Off (down)
position. Errors might occur if these switches are set
to the on position.
Tray Number Switch
–Identifies each expansion unit 0-9.
SAF-TE chip SCSI ID
–Internal SCSI ID numbers 14 and 15.
Netfinity EXP15 Type 3520 11

ESM Board Replacement
To remove the ESM board:
1. Shut down the expansion unit. For shutdown
information, see “Performing a Shutdown”on page 4
2. Grasp each pull-ring and squeeze the latches to
release.
3. Pull open both levers at the same time and remove
ESM board.
Note
When inserting the ESM board:
1. Make sure both levers are straight out, as shown
above.
2. Using your hand, gently push on the center of the
ESM board to insert it into the controller.
3. When inserting the ESM board, make sure both
levers swing inward at the same time.
4. Close and lock both levers at the same time.
Front Controls and Indicators
Power/Fault LED Front BezelActivity LED
Drive CRU
Drive Levers Drive Latch
Note
Only the IBM ServRAID, ServRAID II, ServRAID-3H,
and Fibre RAID controller provide support for the
amber Fault LEDs.
12 IBM Netfinity EXP15, EXP200, EXP500 HMM
Other manuals for EXP15
1
This manual suits for next models
5
Table of contents
Other IBM Storage manuals

IBM
IBM B01 User manual

IBM
IBM Travelstar 2XP User manual

IBM
IBM System Storage TS3310 Setup guide

IBM
IBM Deskstar 22GXP User manual

IBM
IBM DTNA-21800 User manual

IBM
IBM TotalStorage DS300 Instructions for use

IBM
IBM A10 User manual

IBM
IBM SAN192C-6 Manual

IBM
IBM System Storage DS3400 User manual

IBM
IBM DATA MIGRATION SERVICES - User manual
Popular Storage manuals by other brands

Western Digital
Western Digital WDBAAR3200ABK - Elements Portable Specifications

Drobo
Drobo Drobo user guide

Artesyn
Artesyn HDD-500G-SATA quick start guide

Western Digital
Western Digital WDH2Q20000 - My Book Studio Edition II Hard Drive... Specifications

MEMUP
MEMUP Kwest Series Quick starter guide

Denios
Denios FW-K manual