ICP DAS USA M-2004 User manual

M-2004 & M-7004 User Manual, v 1.0.2, Apr. 2020 E-mail: service@icpdas.com
Copyright © 2017 ICP DAS Co., Ltd. All Rights Reserved.
1
M-2004 and M-7004
User Manual
Version 1.0.2/ April 2020

M-2004 & M-7004 User Manual, v 1.0.2, Apr. 2020 E-mail: service@icpdas.com
Copyright © 2017 ICP DAS Co., Ltd. All Rights Reserved.
2
Warranty
All products manufactured by ICP DAS are under warranty
regarding defective materials for a period of one year from the
date of delivery to the original purchaser.
Warning
ICP DAS assumes no liability for damages resulting from the use
of this product. ICP DAS reserves the right to change this manual
at any time without notification. The information furnished by ICP
DAS is believed to be accurate and reliable. However, no
responsibility is assumed by ICP DAS for its use, or for any
infringements of patents or other rights of third parties resulting
from its use.
Copyright
Copyright @ 2017 by ICP DAS Co., Ltd. All rights are reserved.
Trademarks
The names used for identification only may be registered
trademarks of their respective companies.
Contact Us
If you have any problems, please feel free to contact us.
Email: [email protected]

M-2004 & M-7004 User Manual, v 1.0.2, Apr. 2020 E-mail: service@icpdas.com
Copyright © 2017 ICP DAS Co., Ltd. All Rights Reserved.
3
Table of Contents
Table of Contents......................................................................3
Chapter 1. Hardware.............................................................4
1.1. Introduction....................................................................................4
1.2. Features........................................................................................7
1.3. Specifications................................................................................8
1.4. Pin Assignment ...........................................................................10
1.5. Wiring..........................................................................................12
1.6. Block Diagram.............................................................................13
1.7. Dimensions..................................................................................14
1.8. Jumper Settings ..........................................................................15
Chapter 2. Quick start.........................................................16
Chapter 3. Using DS18B20 Temperature Sensor..............23
Chapter 4. DCON Command Sets......................................28
Chapter 5. Modbus Address Mappings.............................34
Chapter 6. Troubleshooting ...............................................41

M-2004 & M-7004 User Manual, v 1.0.2, Apr. 2020 E-mail: service@icpdas.com
Copyright © 2017 ICP DAS Co., Ltd. All Rights Reserved.
4
Chapter 1. Hardware
1.1. Introduction
The M-2004/M-7004 is a digital temperature sensor module that
provides four ports for 2- or 3 wire DS18B20 digital temperature
sensor input. The DS18B20 temperature sensor has a high
accuracy of ±0.5°C when measuring temperatures between -10
and + 85°C, with a total measurement range of between -55 and
+125°C. Up to 20 DS18B20 sensors can be connected to each
port on the M-2004/M-7004 module in a daisy-chain
arrangement with a maximum wiring distance of 100 meters.
The M-2004/M-7004 module is fully RoHS compliant, and
features 4 kV ESD protection as well as 3000 VDC intra-module
isolation.

M-2004 & M-7004 User Manual, v 1.0.2, Apr. 2020 E-mail: service@icpdas.com
Copyright © 2017 ICP DAS Co., Ltd. All Rights Reserved.
5
Applications
Temperature Measurement
Environment Monitoring
Tunnel Monitoring
Building Monitoring

M-2004 & M-7004 User Manual, v 1.0.2, Apr. 2020 E-mail: service@icpdas.com
Copyright © 2017 ICP DAS Co., Ltd. All Rights Reserved.
6

M-2004 & M-7004 User Manual, v 1.0.2, Apr. 2020 E-mail: service@icpdas.com
Copyright © 2017 ICP DAS Co., Ltd. All Rights Reserved.
7
1.2. Features

M-2004 & M-7004 User Manual, v 1.0.2, Apr. 2020 E-mail: service@icpdas.com
Copyright © 2017 ICP DAS Co., Ltd. All Rights Reserved.
8
1.3. Specifications
System Specifications
M-2004

M-2004 & M-7004 User Manual, v 1.0.2, Apr. 2020 E-mail: service@icpdas.com
Copyright © 2017 ICP DAS Co., Ltd. All Rights Reserved.
9
M-7004

M-2004 & M-7004 User Manual, v 1.0.2, Apr. 2020 E-mail: service@icpdas.com
Copyright © 2017 ICP DAS Co., Ltd. All Rights Reserved.
10
1.4. Pin Assignment
M-2004

M-2004 & M-7004 User Manual, v 1.0.2, Apr. 2020 E-mail: service@icpdas.com
Copyright © 2017 ICP DAS Co., Ltd. All Rights Reserved.
11
M-7004

Copyright © 2017 ICP DAS Co., Ltd. All Rights Reserved.
12
1.5. Wiring

Copyright © 2017 ICP DAS Co., Ltd. All Rights Reserved.
13
1.6. Block Diagram

Copyright © 2017 ICP DAS Co., Ltd. All Rights Reserved.
14
1.7. Dimensions
Dimensions (Units: mm)
M-2004
M-7004

Copyright © 2017 ICP DAS Co., Ltd. All Rights Reserved.
15
1.8. Jumper Settings
For the M-7004 modules, the JP1 jumper can be used to enable
providing the RS-485 bias. The position of the JP1 jumper is
shown in the figure below.
The settings for the JP1 jumper is as follows.
Enable RS-485 bias.
Disable RS-485 bias. (factory default)

Copyright © 2017 ICP DAS Co., Ltd. All Rights Reserved.
16
Chapter 2. Quick start
M-2004/M-7004 is a digital temperature sensor module that
supports the DCON and Modbus RTU protocols. The host needs
to use some DCON or Modbus RTU commands to configure and
communicate with the M-2004/M-7004. ICP DAS provides the
DCON Utility Pro program that can configure and test
M-2004/M-7004 without understanding any DCON and Modbus
RTU command. Users can follow below steps to configure
M-2004/M-7004 and read temperature readings from
M-2004/M-7004.
Step 1: Install DCON Utility Pro on the host.
Note: DCON Utility pro supports M-2004/M-7004 for version 2.0.0.7
and later.
ICP DAS provides different versions of DCON Utility Pro for
different platforms that can be used to configure and test I/O
modules. The installation file locations for different platforms are as
follows:

Copyright © 2017 ICP DAS Co., Ltd. All Rights Reserved.
17
For Windows 98,NT,2000,XP,Vista,Win 7 and Win 8 on PC, laptop and etc
computer
CD
CD:\ 8000\NAPDOS\Driver\DCON_Utility
FTP
http://ftp.icpdas.com/pub/cd/8000cd/napdos/driver/dcon_utility/
For ICP DAS CE5 platform PAC
CD
CD:\ napdos\wp-8x4x_ce50\Micro_SD\DCON_Utility_Pro
FTP
http://ftp.icpdas.com.tw/pub/cd/winpac/napdos/wp-8x4x_ce50/
micro_sd/dcon_utility_pro/
For ICP DAS CE6 platform PAC
CD
CD:\ XPAC\XPAC-ATOM-CE6\PC_Tools\DCON_Utility_Pro
FTP
http://ftp.icpdas.com.tw/pub/cd/xpac-atom-ce6/pc_tools/dcon_ut
ility_pro/
For ICP DAS CE7 platform and ARM CPU PAC
CD
CD:\WinPAC_AM335x\Wp-5231\System_Disk\Tools
\DCON_Utility_Pro
FTP
http://ftp.icpdas.com.tw/pub/cd/winpac_am335x/wp-5231/syste
m_disk/tools/dcon_utility_pro
For ICP DAS WES platform PAC
CD
CD:\ XPAC\XPAC-Atom\tools\DCON_Utility_pro
FTP
http://ftp.icpdas.com.tw/pub/cd/xpac-atom/tools/dcon_utility_pro/

Copyright © 2017 ICP DAS Co., Ltd. All Rights Reserved.
18
Step 2: Search and find the M-2004/M-7004 module
Select the correct COM Port and search:
Find the M-2004/M-7004 module, click the module name to enter
configuration form

Copyright © 2017 ICP DAS Co., Ltd. All Rights Reserved.
19
Step 3: Configure M-2004/M-7004 using DCON Utility Pro
To read temperature, each sensor must be assigned a channel
index. The easiest way is to select Temperature tab and select
“Assign all new sensor as default”. Then, you can read the
temperature for all sensors.
For the sensor which is not installed or not assigned, its
temperature reading is -999.99 for DCON protocol and -32768 for
Modbus RTU protocol as shown below.

Copyright © 2017 ICP DAS Co., Ltd. All Rights Reserved.
20
Step 4: Manual update, assign and remove sensor
Select “Update new sensor”to manually assign sensor
Select “Update assigned sensor”then you can read temperature
reported by the sensor:
This manual suits for next models
1
Table of contents
Popular Temperature Controllers manuals by other brands

SensoScientific
SensoScientific OTA Series user guide

Delta Electronics
Delta Electronics AS38BSTD Specifications

Ecom Instruments
Ecom Instruments Ex-Pt 720 operating instructions

S+S Regeltechnik
S+S Regeltechnik THERMASGARD RTF1 KTY81-210 Operating Instructions, Mounting & Installation

Naturela
Naturela NHC-H42-2 user manual

Patol
Patol 5000 Series manual