Idemia MorphoWave OEM User manual

MorphoWaveTM OEM –Installation guide
Warning
2
IDEMIA DOCUMENT –REPRODUCTION AND DISCLOSURE FORBIDDEN
2015_2000009096 V6
January 2019
Warning
COPYRIGHT © 2016 IDEMIA. All rights reserved.
Information in this document is subject to change without notice and do not represent
a commitment on the part of IDEMIA. No part of this document may be reproduced or
transmitted in any form or by any means, electronic or mechanical, including
photocopying or recording, for any purpose without the express written permission of
IDEMIA.
This legend is applicable to all pages of this document.
This manual makes reference to names and products that are trademarks of their
respective owners.

MorphoWaveTM OEM –Installation guide
Revision History
2015_2000009096 V6
January 2019
IDEMIA DOCUMENT –REPRODUCTION AND DISCLOSURE FORBIDDEN
3
Revision History
The table below contains the history of changes made to the present document.
Version
Date
Reference
Description
01
July 2015
2015_2000009096 V1
Document creation
02
December 2015
2015_2000009096 V2
Document update ordering code of
MorphoWave Desktop
03
July 2016
2015_2000009096 V3
Document update for Integrator
tamper switch
04
May 2017
2015_2000009096 V4
Change default Ethernet
configuration to Static IP
Update Contacts section
05
Feb. 2018
2015_2000009096 V5
Update company name (IDEMIA)
06
Jan. 2019
2015_2000009096 V6
Add warning in French (for Canada)
Update with new hardware (connector
change) –Revision 2
Update IDEMIA address

MorphoWaveTM OEM –Installation guide
Table of Content
4
IDEMIA DOCUMENT –REPRODUCTION AND DISCLOSURE FORBIDDEN
2015_2000009096 V6
January 2019
Table of Content
Warning ........................................................................................................................................ 2
Revision History ............................................................................................................................ 3
Section 1 : Introduction ................................................................................................................ 9
MorphoWave™ OEM............................................................................................................... 10
Safety Instructions / Instructions de sécurité.......................................................................... 11
Wiring Recommendations / Recommandations de câblage ............................................... 12
Caution with battery usage / Avertissement sur la pile ...................................................... 13
Caution with Power over Ethernet (POE) usage Avertissement sur l’alimentation électrique
par cable Ethernet (Power over Ethernet POE) ................................................................... 14
Europe information / Information pour l’Europe ................................................................ 14
USA information / Information pour les USA ...................................................................... 14
Canada information / Information pour le Canada............................................................ 16
UL information..................................................................................................................... 17
Recommendations for terminal implementation.................................................................... 19
Section 2 : General Description .................................................................................................. 22
MorphoWaveTM OEM Overview .............................................................................................. 23
MorphoAccess Sigma Wave box opening ............................................................................... 24
Components of the package................................................................................................ 24
Terminal's front view description ........................................................................................ 25
Terminal's rear view description (initial version) ................................................................ 26
Terminal's rear view description (revision 2)....................................................................... 27
MorphoWave™ OEM Wave Technical Characteristics ........................................................ 28
MorphoWaveTM Desktop box opening.................................................................................... 30
MorphoWaveTM Desktop description .................................................................................. 30
MorphoWaveTM Desktop technical description................................................................... 31
PC Wave Intel Core i7 box opening ......................................................................................... 33
Ethernet Switch Wave............................................................................................................. 34
Section 3 : Installation Procedure............................................................................................... 35
MorphoAccess Sigma Wave installation................................................................................. 36
Before proceeding to the installation.................................................................................. 36
Installation........................................................................................................................... 37
Wiring overview................................................................................................................... 42

MorphoWaveTM OEM –Installation guide
Table of Content
2015_2000009096 V6
January 2019
IDEMIA DOCUMENT –REPRODUCTION AND DISCLOSURE FORBIDDEN
5
Power Supply ....................................................................................................................... 45
Output Relay........................................................................................................................ 47
MorphoAccess Sigma Wave Tamper Switch ....................................................................... 48
Integrator Tamper Switch ................................................................................................... 49
Wiegand input wiring .......................................................................................................... 50
Wiegand output wiring ....................................................................................................... 51
Serial port wiring ................................................................................................................. 54
GPIO wiring.......................................................................................................................... 58
Ethernet connection ............................................................................................................ 60
Battery (Initial version only) ................................................................................................ 62
MorphoWaveTM Desktop installation...................................................................................... 63
MorphoWaveTM OEM wiring ................................................................................................... 64
Section 4 : First boot................................................................................................................... 66
First biometric record and identification................................................................................. 67
Default passwords to be changed........................................................................................... 71
First connection to an external network ................................................................................. 72
Modes for controlling access rights ........................................................................................ 73
Introduction ......................................................................................................................... 73
Identification mode ............................................................................................................. 73
Authentication (verification) mode ..................................................................................... 73
Proxy mode.......................................................................................................................... 74
External database mode (also called polling mode) ........................................................... 74
Configuring the terminal ......................................................................................................... 76
MorphoWaveTM OEM native mode ..................................................................................... 76
Anti-tamper / anti-pulling switches ........................................................................................ 77
Section 5 : Accessories, Software Licenses and PC Applications................................................ 78
Compatible Accessories, Licenses and Software..................................................................... 79
Compatible PC applications .................................................................................................... 80
Section 6 : Recommendations .................................................................................................... 81
Notice................................................................................................................................... 82
General precautions ............................................................................................................ 82
Areas containing combustibles............................................................................................ 82
Ethernet connection ............................................................................................................ 82
Date / Time synchronization ............................................................................................... 82
Cleaning precautions ........................................................................................................... 83

MorphoWaveTM OEM –Installation guide
Table of Content
6
IDEMIA DOCUMENT –REPRODUCTION AND DISCLOSURE FORBIDDEN
2015_2000009096 V6
January 2019
Biometric sensor .................................................................................................................. 83
Micro SD card ...................................................................................................................... 85
Lighting conditions for face detection................................................................................. 85
Biometric acquisition guidelines ............................................................................................. 86
Capture Recommendations.......................................................................................... 87
Maintenance procedures ........................................................................................................ 91
Pairing procedure between MorphoAccess and PC............................................................. 91
Unpairing procedure between MorphoAccess and PC........................................................ 92
MorphoWaveTM Desktop change procedure ....................................................................... 94
PC Wave change procedure................................................................................................. 94
MorphoAccess Sigma Wave change procedure .................................................................. 94
Ethernet switch change procedure...................................................................................... 95
Debug logs activation.......................................................................................................... 96
Remote PC Wave connection for maintenance................................................................... 98
MorphoAccess Sigma & PC internal connection checking ................................................ 102
How to get the latest versions of documents ....................................................................... 104
Documents concerning the MorphoWave OEM® terminal................................................... 105
Documents about installing the terminal.......................................................................... 105
Documents about administrating / using the terminal..................................................... 105
Documents for the developer ............................................................................................ 106
Release note ...................................................................................................................... 106
Troubleshooting .................................................................................................................... 108
MorphoWaveTM OEM does not boot at the first installation ............................................ 108
The database loading time is increasing over the time..................................................... 108
MorphoWaveTM OEM displays sensor error message....................................................... 109
MorphoWaveTM OEM displays sensor power error message............................................ 109
MorphoWaveTM OEM frost while capturing fingers during local enrollment ................... 110
The terminal IP address is unknown or it is not possible to connect to the terminal........ 110
The sensor is switched off.................................................................................................. 110
The terminal returns erratic responses to Ping commands .............................................. 110
Contacts ................................................................................................................................ 111
Customer service ............................................................................................................... 111
Hotline ............................................................................................................................... 111

MorphoWaveTM OEM –Installation guide
Table of Figures
2015_2000009096 V6
January 2019
IDEMIA DOCUMENT –REPRODUCTION AND DISCLOSURE FORBIDDEN
7
Table of Figures
Figure 1: Implementation Recommendations.............................................................................20
Figure 2: Box Opening..................................................................................................................24
Figure 3: Box Content ..................................................................................................................24
Figure 4: MorphoWave™ OEM terminal front view....................................................................25
Figure 5: MorphoAccess Sigma Wave terminal rear view (Initial version) .................................26
Figure 6: MorphoAccess Sigma Wave terminal rear view (Revision 2).......................................27
Figure 7: Removing wall frame and screw...................................................................................36
Figure 8: Face camera viewing angle...........................................................................................38
Figure 9: Drilling template ...........................................................................................................39
Figure 10: Wall plate preparation for water tightness................................................................40
Figure 11: Wall plate fixing ..........................................................................................................40
Figure 12: Cabling preparation ....................................................................................................41
Figure 13: Ground wiring .............................................................................................................42
Figure 14: Cabling layout (Initial version) ....................................................................................43
Figure 15: Cabling layout (Revision 2) .........................................................................................44
Figure 16: Power supply wiring (Initial version) ..........................................................................45
Figure 17: Power supply wiring (Revision 2)................................................................................45
Figure 18: Output relay wiring (Initial version) ...........................................................................47
Figure 19: Output relay wiring (Revision 2).................................................................................47
Figure 20: Example of electric latch connection .........................................................................48
Figure 21: MorphoAccess Sigma Wave Tamper switch wiring (Initial version) ..........................48
Figure 22: Tamper switch wiring (Revision 2)..............................................................................48
Figure 23: Integrator Tamper switch wiring ................................................................................49
Figure 24: Integrator Tamper switch wiring (Revision 2) ............................................................49
Figure 25: Wiegand input wiring (Initial version) ........................................................................50
Figure 26: Wiegand input wiring (Revision 2)..............................................................................51
Figure 27: Wiegand output wiring (Initial version)......................................................................51
Figure 28: Wiegand output wiring (Revision 2) ...........................................................................52
Figure 29: Serial port wiring –DataClock (Initial version) ...........................................................54
Figure 30: Serial port wiring –DataClock (Revision 2).................................................................54
Figure 31: Serial port wiring –DataClock (Initial version) ...........................................................55
Figure 32: Serial port wiring –DataClock (Revision 2).................................................................55
Figure 33: Serial port wiring –RS485 (Initial version) .................................................................56
Figure 34: Serial port wiring –RS485 (Revision 2).......................................................................56
Figure 35: Serial port wiring –RS422 (Initial version) .................................................................57
Figure 36: Serial port wiring –RS422 (Revision 2).......................................................................57

MorphoWaveTM OEM –Installation guide
Table of Figures
8
IDEMIA DOCUMENT –REPRODUCTION AND DISCLOSURE FORBIDDEN
2015_2000009096 V6
January 2019
Figure 37: GPIO wiring (Initial version)........................................................................................58
Figure 38: GPIO wiring (Revision 2) .............................................................................................58
Figure 39: SDAC wiring (Initial version) .......................................................................................59
Figure 40: SDAC wiring (Revision 2).............................................................................................59
Figure 41: Direct Point to Point Ethernet Connection.................................................................61
Figure 42: RJ45 wiring..................................................................................................................62
Figure 43. Capturing Prints ..........................................................................................................86

MorphoWaveTM OEM –Installation guide
Section 1 : Introduction
2015_2000009096 V6
January 2019
IDEMIA DOCUMENT –REPRODUCTION AND DISCLOSURE FORBIDDEN
9
Section 1 : Introduction

MorphoWaveTM OEM –Installation guide
Section 1 :Introduction
10
IDEMIA DOCUMENT –REPRODUCTION AND DISCLOSURE FORBIDDEN
2015_2000009096 V6
January 2019
MorphoWave™ OEM
Congratulations for choosing a MorphoWave™ OEM dedicated for contactless
Fingerprint Recognition Terminal.
MorphoWaveTM OEM provides an innovative and effective solution for access control
applications using fingerprints Verification or/and Identification without any contact
on the sensor.
Among a range of alternative biometric technologies, the use of finger imaging has
significant advantages: each finger constitutes an unalterable physical signature,
developed before birth and preserved until death. Unlike DNA, a finger image is unique
to each individual - even identical twins.
MorphoWaveTM OEM integrates Morpho image processing and feature matching
algorithms. This technology is based on lessons learned during 25 years of experience
in the field of biometric identification and the creation of literally millions of individual
fingerprint identification records.
We believe you will find the MorphoWaveTM OEM fast, accurate, easy to use and
suitable for physical access control.
The MorphoWaveTM OEM offers the following advantages:
Four fingerprints sensor,
supports multiple input/output interfaces used in the physical access control
industry,
Local Area Network interface for easy interaction with other host systems through
LAN.
Modular system for easy installation and integration following your needs,
intuitive man machine interface with touch panel and display, that is easy to use in
both setup and operational modes,
open architecture, with dedicated applications implemented via MorphoWaveTM
OEM Software Development Kit.
To ensure the most effective use of your MorphoWaveTM OEM terminal, we
recommend that you read this Installation Guide completely.
Note: This guide adresses 2 versions of the product referred as Initial Version and
Revision 2 (new connector & removable battery).

MorphoWaveTM OEM –Installation guide
Section 1 : Introduction
2015_2000009096 V6
January 2019
IDEMIA DOCUMENT –REPRODUCTION AND DISCLOSURE FORBIDDEN
11
Safety Instructions / Instructions de sécurité
means Direct Current (DC)
The installation of this product should be made by a qualified service Person and should
comply with all local regulations.
For MorphoWaveTM OEM it is strongly recommended to use a class II power supply at
12V-24V and 1A. min (at 12V) in conformity with Safety Electrical Low Voltage (SELV).
The power supply cable length should not exceed 10 meters. Others components of
the MorphoWaveTM OEM are provided with their own power supply.
This product is intended to be installed with a power supply complying with IEC60950-
1, in accordance with the NEC Class 2 requirements; or supplied by a listed IEC60950-1
external Power Unit marked Class 2, Limited Power source, or LPS and rated 12VDC, 1A
minimum or 24VDC, 0,5A minimum.
In case of building-to-building connection it is recommended to connect 0V to ground.
Ground cable must be connected with the terminal block Power Ground.
Note that all connections of the MorphoWaveTM OEM terminal described hereafter are
of SELV (Safety Electrical Low Voltage) type.
For UL294 installation, length of communication (RS422-RS485/Wiegand) and I/Os
(GPI/GPO) cables must not exceed 30 meters.
L'installation de ce produit doit être effectuée par un technicien qualifié et doit être
conforme à toutes les réglementations locales.
Pour MorphoWaveTM OEM, il est fortement recommandé d'utiliser une alimentation de
classe II 12V-24V et 1A. min (à 12V) conforme aux exigences de Très Basse Tension de
Sécurité (TBTS). La longueur du câble d'alimentation ne doit pas dépasser 10 mètres.
Les autres composants du MorphoWaveTM OEM sont fournis avec leur propre
alimentation.
Ce produit est destiné à être installé avec une alimentation conforme à la norme
IEC60950-1, conformément aux exigences NEC Classe 2 ; ou alimenté par une unité
d'alimentation externe certifiée IEC60950-1 de Classe 2, source d'alimentation limitée,
ou LPS, 12VDC, 1A minimum ou 24VDC, 0,5A minimum.
En cas de connexion de bâtiment à bâtiment, il est recommandé de connecter le 0V à la
terre. Le câble de mise à la terre doit être connecté au bornier.
Notez que toutes les connexions du terminal OEM MorphoWaveTM décrites ci-après
sont de type TBTS (Très Basse Tension de Sécurité).
Pour l'installation UL294, la longueur des câbles de communication (RS422-RS485 /
Wiegand) et des I/Os (GPI/GPO) ne doit pas dépasser 30 mètres.

MorphoWaveTM OEM –Installation guide
Section 1 :Introduction
12
IDEMIA DOCUMENT –REPRODUCTION AND DISCLOSURE FORBIDDEN
2015_2000009096 V6
January 2019
Wiring Recommendations / Recommandations de câblage
IDEMIA recommends using a gauge AWG20 for 12V power supply when POE supply is
not used.
The voltage specified is the one measured on the product block connector: 12V-24V (-
15% / +10%)
For information, this table shows the maximum drop voltage observed on the terminal
MorphoWaveTM OEM:
Gauge
AWG
Diameter
(mm)
Maximum
drop
voltage
@ 1m (V)
Maximum
drop
voltage
@ 5m (V)
Maximum
drop
voltage
@ 10m
(V)
20
0.81
0.03
0.17
0.33
22
0.64
0.05
0.26
0.53
24
0.51
0.08
0.42
0.84
Drop voltage = loss of power due to wire resistance and its length: V2 = V1 –Drop
voltage
IDEMIA recommande d'utiliser une jauge AWG20 pour une alimentation 12V lorsque
l'alimentation POE n'est pas utilisée.
La tension spécifiée est celle mesurée sur le connecteur du produit: 12V-24V (-15% /
+10%)
Pour information, ce tableau montre la chute de tension maximale observée sur le
terminal MorphoWave TM OEM:
Jauge
AWG
Diamètre
(mm)
Chute de
tension
Maximum
@ 1m (V)
Chute de
tension
Maximum
@ 5m (V)
Chute de
tension
Maximum
@ 10m (V)
20
0.81
0.03
0.17
0.33
22
0.64
0.05
0.26
0.53
24
0.51
0.08
0.42
0.84
V1
V2
L

MorphoWaveTM OEM –Installation guide
Section 1 : Introduction
2015_2000009096 V6
January 2019
IDEMIA DOCUMENT –REPRODUCTION AND DISCLOSURE FORBIDDEN
13
Tension de chute = perte de puissance due à la résistance du fil et à sa longueur: V2 =
V1 - chute de tension
Caution with battery usage / Avertissement sur la pile
This recommandation is for the MorphoWaveTM OEM terminal initial version only.
The battery is replaced with a capacitor in MorphoWaveTM OEM terminal revision 2.
Cette recommendation s’applique uniquement au terminal MorphoWaveTM OEM de
première génération. Dans la génération 2 du terminal, la batterie est remplacée par
un condensateur.
CAUTION:
RISK OF EXPLOSION IF BATTERY IS REPLACED
BY AN INCORRECT TYPE.
DISPOSE OF USED BATTERIES ACCORDING
TO THE INSTRUCTIONS
Battery must be an UL certified reference.
ATTENTION:
RISQUE D'EXPLOSION SI LA BATTERIE EST REMPLACÉE
PAR UN TYPE INCORRECT.
JETER LES BATTERIES USAGÉES CONFORMEMENT
AUX INSTRUCTIONS
La batterie doit être certifiée UL.
V1
V2
L

MorphoWaveTM OEM –Installation guide
Section 1 :Introduction
14
IDEMIA DOCUMENT –REPRODUCTION AND DISCLOSURE FORBIDDEN
2015_2000009096 V6
January 2019
Caution with Power over Ethernet (POE) usage Avertissement sur
l’alimentation électrique par cable Ethernet (Power over Ethernet
POE)
After use, the temperature of the POE module (optional) may be high:
after power cut off, wait 5mn before working on connectors area.
Après utilisation, la température du module POE (en option) peut être
élevée: après la mise hors tension, attendez 5mn avant de travailler sur la
zone des connecteurs
Europe information / Information pour l’Europe
IDEMIA hereby declares that products delivered (MorphoAcces Sigma, MorphoWave
Desktop) with the MorphoWaveTM OEM bundle have been tested and found compliant
with following listed standards:
EMC Directive 2004/108/CE.
R&TTE Directive (1999/5/CE).
ROHS Directive 2011/65.
IDEMIA déclare par la présente que les produits livrés (MorphoAcces Sigma,
MorphoWave Desktop) avec le pack OEM MorphoWaveTM ont été testés et jugés
conformes aux normes suivantes :
Directive EMC 2004/108/CE.
Directive R&TTE (1999/5/CE).
Directive ROHS 2011/65.
USA information / Information pour les USA
Devices comply with part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) these devices may not cause harmful
interference, and (2) these devices must accept any interference received,
including interference that may cause undesired operation.
Changes or modifications not expressly approved by the party responsible for
compliance could void the user's authority to operate the equipment.
Responsible Party:
IDEMIA
2 Place Samuel de Champlain
92400 Courbevoie - France

MorphoWaveTM OEM –Installation guide
Section 1 : Introduction
2015_2000009096 V6
January 2019
IDEMIA DOCUMENT –REPRODUCTION AND DISCLOSURE FORBIDDEN
15
NOTA : This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential
installation. This equipment generates uses and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Shielded cables must be used with this unit to ensure compliance with category B FCC
restrictions.
Les appareils sont conformes à la partie 15 des règles FCC. Le
fonctionnement est soumis aux deux conditions suivantes: (1) ces appareils
ne doit pas causer d'interférences nuisibles, et (2) ces appareils doivent
accepter toute interférence reçue, y compris celles susceptibles d’entraîner
un fonctionnement non désiré.
Les changements ou modifications n’ayant pas été expressément approuvés par la
partie responsable de la conformité peut invalider le droit d’employer cet équipement
accordé à l’utilisateur.
Partie responsable:
IDEMIA
2 Place Samuel de Champlain
92400 Courbevoie - France
NOTA : Cet équipement a été testé et déclaré conforme aux limites imposées aux
périphériques numériques de classe B stipulées au chapitre 15 du règlement FCC. Ces
limites sont conçues pour fournir une protection raisonnable contre les interférences
nuisibles lorsque l’équipement est utilisé dans un environnement résidentiel. Cet
équipement génère, utilise et peut émettre des fréquences radio et, s’il n’est pas
installé et utilisé conformément aux instructions, peut créer des interférences nuisibles
perturbant les communications radio. Toutefois, rien ne permet de garantir l’absence
totale d’interférence dans une installation donnée. Si l’équipement perturbe la
réception de radios ou de télévisions, ce qui peut être vérifié en éteignant et en
rallumant l’équipement, l’utilisateur est invité à tenter de faire disparaître ces
interférences en recourant à l’une des mesures suivantes:

MorphoWaveTM OEM –Installation guide
Section 1 :Introduction
16
IDEMIA DOCUMENT –REPRODUCTION AND DISCLOSURE FORBIDDEN
2015_2000009096 V6
January 2019
réorienter ou déplacer l’antenne de réception.
augmenter l’écart entre l’équipement et le récepteur.
brancher l’équipement sur une prise située sur un circuit autre que celui auquel est
raccordé le récepteur.
consulter le revendeur ou un technicien expérimenté pour obtenir de l’aide.
Canada information / Information pour le Canada
WARNING TO USERS IN THE CANADA / ATTENTION POUR LES UTILISATEURS AU
CANADA
Devices comply with Industry Canada license-exempt RSS standard(s), and with ICES
003 standard for version(s) without RFID reader. Operation is subject to the following
two conditions: (1) these devices may not cause interference, and (2) these devices
must accept any interference, including interference that may cause undesired
operation of the device.
Under Industry Canada regulations, this radio transmitter may only operate using an
antenna of a type and maximum (or lesser) gain approved for the transmitter by
Industry Canada.
To reduce potential radio interference to other users, the antenna type and its gain
should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not
more than that necessary for successful communication.
ATTENTION POUR LES UTILISATEURS AU CANADA
Les appareils sont conformes à la norme RSS exemptes de licence d’Industrie Canada et
à la norme ICES 003 pour les versions sans lecteur RFID. Son utilisation est soumise aux
deux conditions suivantes : (1) ces appareils ne doivent pas causer d'interférences
nuisibles, et (2) ces appareils doivent accepter toutes les interférences reçues, y compris
celles susceptibles d’entraîner un fonctionnement non désiré.
Conformément à la réglementation d'Industrie Canada, cet émetteur radio ne peut
fonctionner qu'avec une antenne d’un type et d’un gain maximum (ou inférieur)
approuvé pour l’émetteur par Industrie Canada.
Dans le but de réduire les risques d’interférence radio avec d’autres utilisateurs, il faut
choisir le type d'antenne et son gain de sorte que la puissance isotrope rayonnée
équivalente (p.i.r.e.) ne dépasse pas l'intensité nécessaire à l'établissement d'une
communication satisfaisante.

MorphoWaveTM OEM –Installation guide
Section 1 : Introduction
2015_2000009096 V6
January 2019
IDEMIA DOCUMENT –REPRODUCTION AND DISCLOSURE FORBIDDEN
17
UL information
This product has been evaluated by UL regarding “UL 294 Access Control System Units;
Six Edition ; Dated May 10, 2013” and “UL 294B Power Over Ethernet (POE) Power
Sources for Access Control Equipment” First Edition Dated May 10, 2013” on the
following functionality.
Ce produit a été évalué par UL en ce qui concerne «UL 294 : appareils de système de
contrôle d'accès UL 294 6ème édition datée du 10 mai 2013 » et « UL 294B : sources
d'alimentation par câble Ethernet (POE) pour équipement de contrôle d'accès 1ère
édition datée du 10 mai 2013 » sur les fonctionnalités suivantes.
Biometric Access granted/ Access Denied
Accès autorisé / Accés refusé par biométrie
Pin Code Access granted/ Access Denied
Accès autorisé / Accés refusé par pin code
Actuation of the onboard Relay 1/2 (Based on Valid Access
Credential)
Activation du relais sur la carte électronique (basé sur les
informations d'accès valides)
GPIO Output was verified
Vérification GPIO en sortie
GPIO Input was verified.
Vérification GPIO en entrée
RS422/RS485; Wiegand and Ethernet communication were
verified with a supplemental computer employing the
vendor’s proprietary software MBTB. UL version 2.0.4.0.
RS422/RS485; Les communications Wiegand et Ethernet ont
été vérifiées avec un ordinateur supplémentaire utilisant le
logiciel propriétaire MBTB du fournisseur. UL version 2.0.4.0

MorphoWaveTM OEM –Installation guide
Section 1 :Introduction
18
IDEMIA DOCUMENT –REPRODUCTION AND DISCLOSURE FORBIDDEN
2015_2000009096 V6
January 2019
Please note that the following functions have not been evaluated by UL LLC
USB ports and its functionality
Ports USB et fonctionnalités associées
LOGS ;
Video/ Facial Recognition/Audio functions
Vidéo / reconnaissance faciale / Audio
FIPS 201 Personal identification verification features of this
unit
FIPS 201 identification personnelle et vérification
The following Communication: Wi-Fi was not verified by UL. To
List the product and accept the communication protocols we
would need to evaluate the RS485, Wiegand, and Ethernet
with an UL Listed access control unit
Le mode de communication suivant : Wi-Fi n'a pas été vérifié
par UL. Pour lister le produit et accepter les protocoles de
communication, nous aurions besoin d'évaluer le RS485, le
Wiegand et l'Ethernet avec une unité de contrôle d'accès listée
UL
Disposal of waste equipment by users
This symbol means do not dispose of your product with your other household waste. Instead, you
should protect human health and the environment by handing over your waste equipment to a
designated collection point for the recycling of waste electrical and electronic equipment.

MorphoWaveTM OEM –Installation guide
Section 1 : Introduction
2015_2000009096 V6
January 2019
IDEMIA DOCUMENT –REPRODUCTION AND DISCLOSURE FORBIDDEN
19
Recommendations for terminal implementation
Every installation is unique. Sometimes the issues are well defined and can be handled
in a standard fashion; sometimes the issues are very specific and may not be
immediately recognizable.
IDEMIA recommends following these steps for a successful installation:
Plan the installation - Choose the type of hardware required, decide if a network is
required, and decide on the location and number of required terminals.
Unpack all items - Unpack all items and check against the packing list.
Install network hardware components - Install the cabling and components needed
to run the system.
Install software - Install the software needed to set up the terminals.
Pre-configure device - Connect the terminals to the Ethernet, supply power to the
terminals, and pre-configure the terminals.
Mount devices - Mount the terminals in their final locations
Power distribution and device hook up - Connect the terminals wiring via the back
panel of the MorphoAccess Sigma.
Power-up procedure - Check the power connections, verify if battery is attached
and then start the system safely. First Boot Assistant screen is displayed, where you
can perform fundamental configuration.
Note: The battery is for MorphoWaveTM OEM terminal –Initial release only

MorphoWaveTM OEM –Installation guide
Section 1 :Introduction
20
IDEMIA DOCUMENT –REPRODUCTION AND DISCLOSURE FORBIDDEN
2015_2000009096 V6
January 2019
To secure properly an access, IDEMIA recommends installing the MorphoWaveTM OEM
terminal as a part of the typical Access Control environment, described in the figure
below.
Figure 1: Implementation Recommendations
This environment comprises:
The MorphoWaveTM OEM terminal itself
Its role is to perform one-to-many biometric identification or one-to-one biometric
verification, i.e. to identify the individual who is presenting his hand on the terminal
sensor by comparing his biometric data with the references previously stored in the
terminal database (in the form of biometric templates).
An Access Controller (3rd party product)
The Controller is the element which controls the access rights of the individuals to the
secured area. For that reason, it must be located in the secured area.
The individuals who are authorized to access the secured area have their User ID listed
in a so-called "White List" (in contrast with a black list).
The MorphoWaveTM OEM terminal and the Controller are communicating according to
one of the TCP/IP, Wiegand, Dataclock or RS485 protocols:
Other manuals for MorphoWave OEM
1
Table of contents
Other Idemia IP Access Controllers manuals

Idemia
Idemia MorphoWave Compact User manual

Idemia
Idemia VisionPass Instruction manual

Idemia
Idemia MorphoAccess VP MD Instruction manual

Idemia
Idemia MorphoAccess SIGMA Extreme Series Instruction manual

Idemia
Idemia MTop Slim V3 User manual

Idemia
Idemia VisionPass User manual

Idemia
Idemia MorphoWave Compact Instruction manual