Idemia MorphoAccess VP MD Instruction manual

IDEMIA DOCUMENT –REPRODUCTION AND DISCLOSURE PROHIBITED.
MorphoAccess®VP MD
Quick User Guide
2019_2000041669-V1
All descriptions, illustrations, and specifications in this brochure should be considered approximate and may relate to optional equipment or feature

IDEMIA DOCUMENT –REPRODUCTION AND DISCLOSURE PROHIBITED.
1
Table of Contents
MorphoAccess® VP MD –Quick User
Guide - 2019_2000041669-V1
Color
Step
Content
One
Overview
Two
Wiring
Three
Communication
Four
ACP or SDAC
Five
Administration
Six
Software
Seven
Enrollment
Eight
Optional features

IDEMIA DOCUMENT –REPRODUCTION AND DISCLOSURE PROHIBITED.
2
Product Overview
The MorphoAccess®VP MD terminal has a
simple and ergonomic man-machine
interface designed for access control, with
fingerprint and vein recognition, and
contactless card authentication.
(plugged under the terminal)
Power consumption shall
not exceed 500mA
MorphoAccess® VP MD –Quick User
Guide - 2019_2000041669-V1
Multimodal biometrical
sensor (optical)
Embedded web server
(configuration & enrolment)
User feedback
LED panel
USB host port
(for configuration and
settings with a USB mass
storage key, or for
installation of a Wi-Fi™
USB dongle)
Buzzer
Step one : overview
RF Card reader
(MIFARE™DESFire ™
13,56MHz )

IDEMIA DOCUMENT –REPRODUCTION AND DISCLOSURE PROHIBITED.
3
MorphoAccess®VP MD Checklist
MorphoAccess® VP MD –Quick User
Guide - 2019_2000041669-V1
Electronic documentation is provided in Adobe® Acrobat® format (PDF). Adobe® Acrobat® Reader is available at http://www.adobe.com.
Step one : overview
Product packaging checklist:
QTY
ITEM
1
MorphoAccess
® VP MD terminal
1
Top
cover fixed to the terminal
1
Bottom
cover fixed to the terminal
1
Wall Mounting Plate
1
Connection
cable
4
M3X10 Screws (for terminal fixing to the wall plate)
4
K25x8 Screws (Bottom cover fixing)
1
Documentation package
( X4)
M3-10
Torx 10 Print
( X4)
K25-8
Torx 8 Print

IDEMIA DOCUMENT –REPRODUCTION AND DISCLOSURE PROHIBITED.
4
ACCESS CONTROL
SYSTEM
(*) OR EQUIVALENT
NON SECURED
AREA
ACCESS
CONTROLLER
TCP/IP, Wiegand, Dataclock, RS485
ELECTRIC
LATCH (*)
SECURED
AREA
Dry Contact
MorphoAccess®
VP MD Terminal
Dry Contact
ALARM
MorphoAccess®VP MD terminal Implementation
MorphoAccess® VP MD –Quick User
Guide - 2019_2000041669-V1
Step one : overview
The MorphoAccess®VP MD terminal
Its role is to process the access request from the user. It performs access
right checks using one-to-many biometric identification or one-to-one
biometric verification, and/or RF card authentication.
A Door Electric Latch or equivalent (3rd party product)
The Access Controller sends a command to activate the latch if the access is granted (i.e. if the individual's User ID is listed in the
Controller authorized user List). Control of the latch is made through a dry contact..
An Alarm (3rd party product)
The MorphoAccess®terminal sends a message to the Access Controller, to
activate the Alarm as soon as a malicious activity, such as tamper or pulling, is
detected
To secure an access, IDEMIA recommends installing the MorphoAccess®VP MD terminal as a part of a typical Access Control system,
which consists of the components described below.
An Access Controller (3rd party product)
The MorphoAccess®terminal interfaces with an Access Controller
(using TCP/IP, Wiegand, Data Clock or RS485 protocol):
After access request, the MorphoAccess®terminal sends the
result of user’s access rights to the Access Controller (this
message contains at least the User ID)
The Access Controller performs additional checks, and returns
the final decision (access granted/denied) to the MorphoAccess®
terminal (which displays the result to the user), and to the door
controller which opens the door (if the access has been granted).
A
A
B
B
D
D
C
C

IDEMIA DOCUMENT –REPRODUCTION AND DISCLOSURE PROHIBITED.
5
Typical Access Control Process
On Access
Request, the
terminal checks
user’s access
rights using a
biometric check.
If the result of the
check is successful
(user recognized ),
a message is sent
to the Central
Access Controller
for additional
access rights
check.
If the user is
allowed to access
to the protected
zone, the central
access controller
returns an "access
granted" message
to the terminal and
a “open” command
to the gate
controller.
MorphoAccess® VP MD –Quick User
Guide - 2019_2000041669-V1
Step one : overview
User’s fingerprints and veins must be stored in the terminal database or in contactless card, to enable
biometric check.

IDEMIA DOCUMENT –REPRODUCTION AND DISCLOSURE PROHIBITED.
6
MorphoAccess®VP MD Access Control Modes
MorphoAccess® VP MD –Quick User
Guide - 2019_2000041669-V1
Step one : overview
The terminal can be configured in one of the modes described in the table below
Identification
Authentication
Multifactor
Proxy
Access
control
a
pplication
Application that runs
on the terminal when
it starts.
Application that runs
on the terminal when
it starts.
Application that runs
on the terminal when
it starts.
Remote application
that controls the
terminal through
network commands
Access
control
triggering
event
A
user places a
finger on the
biometric sensor.
A user places
a
contactless
card in
front of
the reader.
(*)
Both
Identification
and Authentication
triggers are enabled.
Triggering events are
selected
by the
remote application
Biometric
check (if
enabled)
The user’s captured
fingerprint/vein is
matched against all
fingerprints in the
terminal database.
The user’s captured
fingerprint is
matched against
their reference
fingerprint/vein. (**)
As per Identification
or Authentication,
depending on the
triggering event
Selected
by the
remote application
Decision
to
display
result
signal to user
By Identification
standalone
application
By Authentication
standalone
application
By
running
s
tandalone
application
By remote
application
(* ) or a Wiegand frame is received from an external device
(**) stored on the contactless card or in the user record in the terminal’s local database

IDEMIA DOCUMENT –REPRODUCTION AND DISCLOSURE PROHIBITED.
7
Deployment Environments
General precautions
Do not expose the terminal to extreme temperatures.
When the environment is very dry, avoid synthetic carpeting near the MorphoAccess®VP MD terminal, to
reduce the risk of unwanted electrostatic discharge.
Areas containing combustibles
Do not install the terminal in the vicinity of gas stations or any other installation containing flammable or
combustible gases or materials. The terminal is not designed to be intrinsically safe.
The terminal should be installed in controlled lighting conditions
Avoid biometric sensor exposure to a blinking light
Avoid direct exposure of the biometric sensor to sunlight or to UV lights.
MorphoAccess® VP MD –Quick User
Guide - 2019_2000041669-V1
Step one : overview
Operating temperature
-
10°to + 50 °C (14°to 122°F)
Operating
humidity
10 % < RH < 80 % (non condensing)
Storage
temperature
-
20°to + 70 °C (-4°to 158°F)
Storage
humidity
5% < RH < 95 %

IDEMIA DOCUMENT –REPRODUCTION AND DISCLOSURE PROHIBITED.
8
Power supply from electrical source shall be switched off before starting the installation.
Before proceeding, make sure that the person in charge of installation and connections, is properly connected to
earth, in order to prevent Electrostatic Discharges (ESD).
Wiring Overview
MorphoAccess® VP MD –Quick User
Guide - 2019_2000041669-V1
All connections of the terminal are of SELV (Safety Electrical Low Voltage) type.
Step two : wiring
Backup of the Date/Time of the terminal: the volatile settings (such as date/time) of the terminal are protected against
power failure, by a dedicated component during a least 24 hours (at 25oC) without external power supply.
RS485
15
RS485_RX+/TX+ (A)
Blue /
Black
13
RS485_TX
-/TX- (B)
Blue / White
17
RS485_GND
Black /
Red
GP IN & OUT
12
GPIO_GND
Black /
Red
9
GPI0
Orange
11
GPI1
Orange /
Red
16
GPI2
Orange / Black
10
GPO0
Yellow
8
GPO1
Yellow /
Red
14
GPO2
Yellow / Black
Wiegand IN & Wiegand OUT
19
WIEG_IN_D0
Green /
Red
20
WIEG_IN_D1
White /
Red
18
WIEGAND_GND
Black /
Red
21
WIEG_OUT_D0
Green
23
WIEG_OUT_D1
White
24
WIEG_OUT_LED1
Blue
22
WIEG_OUT_LED2
Blue /
Red
Power supply, Tamper switch & Relay
1
Power +12V
Red
2
Power GND
Black
3
SWITCH_PIN1
Light Blue
4
SWITCH_PIN2
Pink
5
RELAY_NO
Yellow / White
6
RELAY_COM
Grey / White
7
RELAY_NC
Orange / White
RJ-45 USB

IDEMIA DOCUMENT –REPRODUCTION AND DISCLOSURE PROHIBITED.
9
External Power Supply: 12-24 Volts (regulated and filtered) 1 Amp min @12V, CEE/EEC EN60950 standard
compliant. A12 Volts power supply compliant with SIA's Wiegand standard will also be suitable. If sharing
power between devices, each unit must receive 1A (e.g. two units would require a 12vDC, 2A supply).
Power Over Ethernet (POE): power can be provided through RJ-45 connector using
a PSE (Power Sourcing Equipment) IEEE 802.3af or IEEE802.3at type 1 compliant.
The terminal is a Class 0 (15.4W) PD (Powered Device).
Step two : wiring
PoE Injector Specs
Output Voltage: 48VDC
Output Current: 0.32A
Power: 15.36W
A battery backup or uninterrupted power supply (UPS) with built-in surge protection is recommended.
WARNING: Under powering may cause memory and data corruption; over powering may cause hardware damage.
Both of these situations will void the warranty
Gauge
AWG
Diameter
(mm)
Maximum drop voltage
(V)
at 1m
at 5m
at 10m
20 0.81 0.03 0.17 0.33
22 0.64 0.05 0.26 0.53
24 0.51 0.08 0.42 0.84
IDEMIA recommends using a gaugeAWG20 for 12V power supply.
The voltage measured on the product block connector of the terminal
must be equal to 12V-24V (-15% / +10%).
The table at the right, shows the maximum voltage drop between the
power source and the terminal, depending on the length of the cable.
MorphoAccess® VP MD –Quick User
Guide - 2019_2000041669-V1
Power Wiring
Power supply, Tamper switch & Relay
1
Power +12V
Red
2
Power GND
Black
RJ-45

IDEMIA DOCUMENT –REPRODUCTION AND DISCLOSURE PROHIBITED.
10
RS-485 Communication
MorphoAccess® VP MD –Quick User
Guide - 2019_2000041669-V1
A maximum of 31 devices may be installed on the same line.
The maximum total cable length is 4000 ft. (1200m).
The cable must be dedicated to this installation and not used for any other purpose
Step three : communications
RS-232
from the
Com Port
RS-232 to
RS-485
converter RS-485 to
1200m (4000ft)
For RS-485 installations, the cable should be run in a daisy-
chain configuration (i.e. converter > position 1 > position 2 >
position 3, etc.).
Use CAT-5 UTP (or better) cable (shielded recommended) with a characteristic impedance of 120 ohms.
AWG 24 should be the minimum wire gauge used.
Choose one twisted pair of conductors to use for RS-485
TDA (Blue / White Black - Pin 15) and RS-485 TDB (Blue /
White wire - Pin 13).
Another conductor should be used for Signal Ground
(Black / Red wire - Pin 17).
Choose a RS-232 to RS-485 converter that supports Sense Data to switch from Send to Receive mode.
RS485
15
RS485_RX+/TX+ (A)
Blue /
Black
13
RS485_TX
-/TX- (B)
Blue / White
17
RS485_GND
Black /
Red

IDEMIA DOCUMENT –REPRODUCTION AND DISCLOSURE PROHIBITED.
11
Ethernet and Wireless LAN
MorphoAccess® VP MD –Quick User
Guide - 2019_2000041669-V1
Step three : communications
LAN Ethernet
Management
station
Wireless
IP address
Mode Parameter Factory value
Static
Terminal IP
address 192.168.1.10
Gateway IP
address 192.168.1.254
Sub network
mask 255.255.254.0
Host name MA-VP
RJ-45 Ethernet connection
Ethernet connection to the terminal is made through a
standard RJ-45 connector on the back of the terminal.
Use a category 5 shielding cable (120 Ohms) or better. It is
strongly recommended to insert a repeater unit every 90m.
By default, MorphoAccess® VP MD terminal is configured in
Static IP mode.
WLAN option
This option is available only with Wi-Fi™ dongle (and adaptation
cable) delivered by IDEMIA(kit reference 293658530), and
requires the terminal be powered by an externalAC/DC 12V to
24V power supply (the POE feature doesn’t provide enough
power for the terminal and the dongle).
Morpho Wi-Fi™ dongle supports 802.11b and 802.11g standards,
WEP Open, WPA and WPA2.
The Wi-Fi™ dongle shall not be exposed to temperatures exceeding 50ºC (don’t forget to include the
thermal dissipation of the product and of the Wi-Fi™ dongle).

IDEMIA DOCUMENT –REPRODUCTION AND DISCLOSURE PROHIBITED.
12
Wiegand Communication
MorphoAccess® VP MD –Quick User
Guide - 2019_2000041669-V1
Step three : communications
Wiegand Out
Wiegand In
LED
Three-conductor wire (shielded recommended) is required for Data 0, Data 1, and WGND.
Use 18-22AWG cable in a homerun configuration from each unit to theAccess Control Panel (ACP).
Connect WIEGAND_OUT0 (Green Wire - pin 21) to ACP Data 0,
Connect WIEGAND_OUT1 (White Wire - pin 23) to ACP Data 1,
Connect WIEGAND_GND (BLACK / Red Wire - pin 18) to ACP reader common (0vDC).
For 18 AWG, the maximum cable distance is 500 ft. (150m); for 20 AWG, the maximum is 300 ft. (90m); for 22
AWG, the maximum is 200 ft. (60m).
All controller output shall be open drain or 5V+/-5%
Wiegand IN & Wiegand OUT
19
WIEG_IN_D0
Green /
Red
20
WIEG_IN_D1
White /
Red
18
WIEGAND_GND
Black /
Red
21
WIEG_OUT_D0
Green
23
WIEG_OUT_D1
White
24
WIEG_OUT_LED1
Blue
22
WIEG_OUT_LED2
Blue /
Red

IDEMIA DOCUMENT –REPRODUCTION AND DISCLOSURE PROHIBITED.
13
Wiegand Communication (continued)
MorphoAccess® VP MD –Quick User
Guide - 2019_2000041669-V1
Example Format Information
Type: Standard 26-bit
Alt Site Code and Fail Site Code Range: 0-255
Template ID Number Range: 1-65535
Extended ID Number Range: N/A
ID Start Bit: 9
Length of ID: 16
Site Code Start bit: 1
Length of Site Code: 8
Start Bit length : 0
Step three : communications
Important
By default, the Wiegand output format is not enabled.
Wiegand output must be configured before connecting to the
ACP.
Note
On installation, the system administrator will be prompted to
select either a pre-existing Wiegand frame format or create a
custom format, and upload it to the unit before the first use.
Data Clock
The Wiegand port also supports the Clock & Data protocol.
The wiring is described below.
Data Clock Out
Data Clock In
LED
Data
Clock
Data
Clock
Wiegand IN & Wiegand OUT
19
WIEG_IN_D0
Green /
Red
20
WIEG_IN_D1
White /
Red
18
WIEGAND_GND
Black /
Red
21
WIEG_OUT_D0
Green
23
WIEG_OUT_D1
White
24
WIEG_OUT_LED1
Blue
22
WIEG_OUT_LED2
Blue /
Red

IDEMIA DOCUMENT –REPRODUCTION AND DISCLOSURE PROHIBITED.
14
Single Door Access Control (SDAC)
MorphoAccess® VP MD –Quick User
Guide - 2019_2000041669-V1
Step four:ACP or SDAC
GPI1
GPO0
GPI0
GPO1
Relay_NO
Relay_Com
Deadbolt / Door strike
Power
supply
Door contact
Power
supply
Push Button
GP IN & OUT
12
GPIO_GND
Black /
Red
9
GPI0
Orange
11
GPI1
Orange /
Red
16
GPI2
Orange / Black
10
GPO0
Yellow
8
GPO1
Yellow /
Red
14
GPO2
Yellow / Black
Relay
5
RELAY_NO
Yellow / White
6
RELAY_COM
Grey / White
7
RELAY_NC
Orange / White
Warning
•Please check next page for important information about internal relay rating
•If door contact is not used, GPI1 (Orange / Red wire) and GPO1 (Yellow / Red wire) shall be
connected together
•Power supply from electrical source shall be switched off before starting the installation.

IDEMIA DOCUMENT –REPRODUCTION AND DISCLOSURE PROHIBITED.
15
Internal Relay Wiring
MorphoAccess® VP MD –Quick User
Guide - 2019_2000041669-V1
Step four:ACP or SDAC
Deadbolt / Door strike
Push Button
on other side
of the door
Snubber Diode
Example for normally
open connection
Warning
This applies only for small or
stand-alone applications where
access control panels are not
available.
In this mode it is strongly
recommended to monitor the
Tamper Detection of the device
Relay mode can be changed to “normally close” instead of “normally closed” (default)
Inductive load management requires a parallel diode for a better contact lifetime.
Warning
The internal relay is limited to a maximum current of 1A @ 30V. If the deadbolt / door strike
draws more than 1A, damage to the device may occur. If the deadbolt / door strike load exceeds
1A, an external relay must be used.
The internal relay is designed for 100.000 cycles. If more cycles are needed, an external relay
driven by GPO must be used.
Power supply
VCC < 30V
Imax < 1A
Relay
5
RELAY_NO
Yellow / White
6
RELAY_COM
Grey / White
7
RELAY_NC
Orange / White

IDEMIA DOCUMENT –REPRODUCTION AND DISCLOSURE PROHIBITED.
16
First communication with terminal (1/2)
MorphoAccess® VP MD –Quick User
Guide - 2019_2000041669-V1
First configuration requires a network link
The MorphoAccess®VP MD terminal is designed to be able to run in standalone mode,
but at least point to point connection between PC and terminal is necessary for the first
configuration. It could also be necessary for database management, terminal
maintenance, …
Step five: Administration
Network connection methods
Point to point Ethernet connection
This method requires a static IP configuration (except
if DHCP server is installed on PC)
‒Use MorphoBioToolBox to configure network parameters
(see next page)
Connection through a LAN (Local Area Network)
If DHCP server is available on the network, network
parameters will be automatically affected to terminals
(contact your network administrator).
If no DHCP server is available, it is necessary to
configure a static IP on each terminal and PC.
‒Use MorphoBioToolBox to configure network parameters
(see next page)

IDEMIA DOCUMENT –REPRODUCTION AND DISCLOSURE PROHIBITED.
17
Configuration using MorphoBioToolbox
Fill IP address and Network mask following
previous paragraph recommendations.
Even if not used, fill Gateway, Preferred and
Alternate DNS values (using 1.1.1.1 for
example).
Click on “Write Usb Script” button and save it
on USB key.
Plug USB key to the terminal using the
adaptor.
A high pitched beep, followed by purple led panel
blinking and high pitched beeps and green led
panel will indicate configuration is finished
First communication with terminal (2/2)
MorphoAccess® VP MD –Quick User
Guide - 2019_2000041669-V1
General remark for network configuration
If terminal is connected to local network without DHCP server, be sure to configure the following
parameters :
Administration PC and all terminals shall have a different IP address (Host PC IP address with any IP
address within 192.168.x.x range excluding 192.168.1.10).
Administration PC and all terminals shall have the same network mask (ex : 255.255.255.0 if the 3 first
bytes of IP address are the same for all terminals and PC).
Step five: Administration

IDEMIA DOCUMENT –REPRODUCTION AND DISCLOSURE PROHIBITED.
18
Administration with Embedded Web Server
The terminal’s embedded Web
server enables easy configuration of
the devices as well as user
enrolment using a web browser on a
Desktop PC, Laptop, Tablet or smart
phone.
The connection to the embedded
Webserver, through LAN or WLAN,
requires terminals IP address and
terminals password.
Deactivate Webserver if not used.
MorphoAccess® VP MD –Quick User
Guide - 2019_2000041669-V1
Terminal administration & User enrolment with a standard web browser
Step five: Administration

IDEMIA DOCUMENT –REPRODUCTION AND DISCLOSURE PROHIBITED.
19
Administration with MorphoBioToolBox application
Another way to configure the
MorphoAccess®VP MD terminal is to
use a dedicated application:
MorphoBioToolBox (for Windows)
Please note that this application has
an embedded User Guide (Help
menu).
MorphoAccess® VP MD –Quick User
Guide - 2019_2000041669-V1
Terminal administration with MorphoBioToolBox application
Step five: Administration
North and South America:
E-mail
support.bioterminals@idemia.com
with your name, phone number, serial
number of your MorphoAccess®and
“Please Send Link for MBTB” in the
subject of your e-mail.A link to
download the software will be e-
mailed to you.
Other countries: please contact your
sales representative.
Other manuals for MorphoAccess VP MD
1
Table of contents
Other Idemia IP Access Controllers manuals

Idemia
Idemia MorphoWave OEM User manual

Idemia
Idemia VisionPass Instruction manual

Idemia
Idemia MorphoAccess SIGMA Extreme Series Instruction manual

Idemia
Idemia MTop Slim V3 User manual

Idemia
Idemia VisionPass User manual

Idemia
Idemia MorphoWave Compact User manual

Idemia
Idemia MorphoWave Compact Instruction manual
Popular IP Access Controllers manuals by other brands

Carrier
Carrier Supra iBox BT LE user guide

Pongee Industries
Pongee Industries Pegasus PC-1074 user manual

Alcad
Alcad 969 Series manual

DMP Electronics
DMP Electronics X1 Installation and programming guide

AWID
AWID SENTINEL-PROX MR-1824 Installation & operation manual

C Prox Ltd
C Prox Ltd DPN-2 user manual