IGEBA NEBUROTOR User manual

NEBUROTOR
Instruction manual
Cold fogger
DIN EN ISO 9001:2008

Bda
Neburotor eng!.
7/02
S U M M A
RY
1.
How
to
use this manual
2. Definition
of
the
symbols used 2
3. Technical specifications 3
4. Main features 3
5. General information 4
6. Packaging 6
7.
Use
6
8. Recommendations on application 8
9.
Consumption 10
10. Maintenance 11
11. Spare parts
13
12. Table
of
spare parts
15
- 1 -

Bda
Neburotor engl.
7/02
.
1.)
How
to
use
this
manual
These instructions contain all the information necessary for the use
of
the
appliance,' complete with diagrams, including receipt, use, start-up,
maintenance, cleaning,
as
weil
as
all the safety precautions
to
be
taken
throughout the lifetime
of
the appliance.
For ease
of
consultation, the contents are divided up by subject.
The appliance is built in accordance to the European directives 89/336/EEC,
93/68/EEC and relative updates, and presents no risk for the operator
if
used
as
described in these instructions supplied by IGEBA, provided the
safety devices are kept in efficient working order all times.
IGEBA accepts no responsibility in the event
of
modifications
to
the machine
or
operations carried
out
contrary to the contents
of
these instructions,
that
might cause damage
to
persons, property
or
the environment.
Due to the continuous technological development
of
the products, the
technical information contained in this manual
might
change without notice.
IGEBA
truststhat
you will
be
fully satisfied with
the
performance
of
the
new
appliance.
2.)"D:efi'nition'of
the
symbols used
__
The
CE
mark
indicates
that
the appliance conforms with the
EC
directives.
Consult
this
instruction and maintenance manual carefully before carrying
out
any
operations on the appliance.
General warning, risk
of
danger
or
possibility
of
damaging the appliance
pay
particular
attention to the words
that
follow this symbol. '
Risk
of
electrical danger. The words
that
follow refer to conditions
that
could become dangerous. Follow
the
Instructions
ca
refulIy.
Use
individual protection equipment suitable
for
the materials fogged
by
the appliance.
Malntenance and I
or
checking operations requiring particular caution
or
the
Intervention
of
a specialist operator
or
themanufacturer.
- 2 -

Bda
Neburotor eng
I.
7/02
3.)
Technical specifications
Type:
Motor:
Protection class:
Power
rating:
Tank
capacity:
Output
capacity:
Weight,
empty:
Dimensions:
Swivelling range:
4.)
Main
features
Electric, rotating, cold fogger
Electric, voltage ratings available:
220 / 240 Volt,
50/60
Hz
110 / 120 Volt,
50/60
Hz
Zero (Motor windings are open)
700 Watt
4 Litres
15 to 250
mi/minute,
max. 15 I / h
3,9
kg
Length:
Height:
Tank diameter:
10 -3600
35 cm
40 cm
25 cm
NEBUROTOR
is
an example
of
the
natural technical evolution
that
has always been
a typical feature
of
IGEBA products and equipment, and
it
is the ideal tool
for
safe
and effective pest contral, disinfectant and deodorizing treatments.
The
mai"
features
are:
-The body containing the electric
motor
is
divided in
two
parts,
for
speed
of
dismantling, greater practicality and ease
of
maintenance.
-The innovative flow regulator (already tried and tested
on
NEBULO), which
makes use
of
a system
for
the
identification
of
the
adjustment
pin position
(notch by notch movement), means
that
you always know exactly how much
liquid
is
being issued, from a minimum
of
15
cc
to
a maximum
of
250 ml per
minute, depending in
the
type and viscosity level
of
the
liquid
to
be
fogged.
- 3 -

Bda
Neburotor eng!.
7/02
Other
features
are:
-Shock and chemical resistant thermoplastic structure
-Powerful electric motor,
commutator
type
-Micronisation regulated in proportion
to
the
amount
of
liquid issued
-Possibility
of
swivelling
of
the body
-Versatility, with
the
possibility
of
fogging insecticide, disinfectant and
deodorant
-Above average fogging
output
compared
to
other
machines in
the
same
dass
-Manageable and easy
to
use
Today more than ever,
NEBUROTOR
is
the
ideal appliance
for
use in restaurants,
bars, hotels, campsites, foods storage areas, canteens, communities, schools,
banks, offices, dinics, means
of
transport and any
other
location
that
requires pest
control, disinfectant and deodorizing treatments.
5.)
General
information
•
Read
these instructions
on
the safety, assembly, use and maintenance
of
the
appliance carefully.
• Keep this manual.
If
the
appliance is transferred, give
the
manual
to
the
new
owner.
•
00
not
leave the packaging materials within
the
reach
of
children.
•
00
not use adapters, multiple sockets
or
extension leads.
• Keep
the
appliance
out
of
the reach
of
children.
•
Use
the appliance only
for
the purpose
it
was designed for.
• Keep
the
power supply cable away from heat sources, oil, sharp edges and
rough surfaces.
00
not pull the cable
to
remove
the
plug.
• Never use
the
appliance with
wet
hands
or
feet
or
with bare feet.
• Always switch
off
after
use.
•
00
not leave the plug in the socket when
the
appliance
is
not
in use.
• Always use original spare parts.
• Never modify
the
appliance.
- 4 -

Bda
Neburotor engl.
7/02
• Always store the appliance in a
dry
place,
far
from heat sources. Never leave
it
exposed
to
the elements (rain, sunlight etc.).
• Take all
the
precautions set
out
on
the
labels
of
the
products you are using.
Do
not handle
the
parts
of
the
appliance
that
come into contact
with
the
substances before cleaning the appliance thoroughly.
• All personnel exposed
to
the aerosols produced by
the
appliance should wear
approved respirators.
•
Do
not
fog products containing aggressive solvents
that
could damage
the
plastic parts (such
as
methylene chloride).
•
Do
not
fog near naked flames.
• Always keep
the
suction
filter
inside the
tank
clean.
After
use with wettable
powders
that
can be dampened, we advise fogging with warm water
to
clean
the
appliance.
• Periodically check
the
cleanliness
of
the
air
filter.
If
the
motor
does
not
get
a sufficient
quantity
of
clean
air,
the
fogging operation
will
be
inefficient
and
the
motor
will
overheat
and could
suffer
damage.
•
Do
not use sharp pointed objects
to
clean the hole
of
the
nozzle, use a brush.
• Never leave
the
appliance unattended while
it
is
operating, and make sure
that
the
air
breathed by the
motor
is
as
dry
as
possible.
•
After
each
treatment,
clean
the
outside
of
the appliance and remove any
liquid
left
in
the
tank.
•
Never
carry
out
maintenance operations
(outside
cleaning,
tank
cleaning
etc.)
if
the
appliance is connected
with
a
power
socket.
•
In
the
event
of
damage
to
the
power
cable,
this
should be replaced
only
with
the
spare
part
available
from
IGEBA.
The
cable
replacement
operation should be carried
our
by specialist personnei.
•
We
accept no responsibility
for
damage
caused by incorrect use
of
the
appliance
or
as a result
of
tampering
with
it.
IMPORTANT
NEBUROTOR is
to
be
used
for
the
distribution
of
chemical
products
in
aerosol
form.
Some
chemical
products
(for
example
insecticides
and
disinfectants)
require
approval
or
registration
by
various
government
bodies. The
use
of
some
products
may
be
restricted
by
or
subject
to
special
regulations.
- 5 -

Bda
Neburotor engl.
7/02
6.
.)
Packaging.·
The appliance comes packed in
,a cardboard box. Check
that
it
is
in
undamaged condition after
removing
it
from the box.
Dispose
of
the packaging
materials correctly.
5
-.J.'
7.)
Use
Remove the
c10sure
ring
(5)
and remove the
tank
(4)
for
filling.
Make sure
the
plug
(3)
is disconnected from the power socket
of
main supply.
Pour the product into the
tank
(4), making sure
that
this is Clean,
to
avoid
contamination between different products.
Replace the appliance
on
the
tank
exactly and return the closure ring
(5)
to
its
position, move the handle to correct position.
Before connecting the appliance
to
a power socket, make sure
that
the voltage
indicated on the socket is the same as
that
of
the motor, as shown on the
label attached
to
the filter cover. Also make sure
that
the switch
(1)
is
set
to
the "OFF" position.
Aim the nozzle in the required direction and switch on the appliance
by
moving the switch (1) to
the
"ON" position. The appliance will begin
to
fog
after
a few seconds.
Adjust the quantity
of
product
to
be distributed using the flow regulator knob
(2),
turn
to
the right until
c10sed
position, then turn to the left into the desired
position, count the number
of
locking positions (see page
10).
-
6-

·
:.
, .
'~"
.
Bda
Neburotor eng!. 7/02
After a few seconds,
the
unit
will start
to
fog and rotate. Adjust
the
f10w
regulator
(29)
to
'obtaln
the, deslred fog performance, by means
of
the 'knurled brass knob,
arrow
shows
toward below. "
The
unlt
Is
equlpped wlth
the
stop pln no.
1,
for
the
360
0 rotation, Installed.
If
a
180
0
rotation Is requlred, following the pictures, move the stop pin no. 1 from
the
pOSition A
to
the position
Band
Insert
the
stop pin no. 2, included wlth the
unlt,
into the position C (see
page 7, picture A).
To move the plns from
their
position, unscrew the self-Iocking nut,
as
shown on picture
B.
Whenthe
stop pins are in
their
position,
be
sure
to
align them as Indicated on picture
C.
We
suggest to replace in
the
holes remained free, the black plastic hole plugs,
so
as
to
avoid
that
eventual'impurities can enter into the tank.
Remount the unit on the
tank
and place again the clamp ring
(7)
in the right position.
A--~
B
FIG.A
FIG.8
, i ,
'-t·
FIG.C
-
7-
c

Bda
Neburotor engl.
7/02
8.)
Recommendations
on
application
GENERAL
Read
the labels and instructions
on
the containers
of
the products you use.
Always use an approved breathing mask suitable
for
the particle sizes and
the substance fogged.
INDOOR
APPLICATIONS
-Remove all animals from the area
if
possible.
-Isolate the area
to
be
fogged as
far
as
possible. Close all doors and
windows. Switch
off
all air conditioning systems and fans and keep
these switched
off
for
at
least
an
hour
after
the treatment.
-For best results, keep the internal doors, drawers and cabinets in the
area
to
be
treated open. All unsealed food containers should
be
removed
or
sealed~
-Although the risk
of
explosion
is
remote, the correct procedure
requires
that
all flames, warning lamps, and
so
on
be
extinguished.
-All foodstuff, plants, surfaces
or
other objects
that
could come into
contact with the substance fogged should be removed, sealed
off
or
covered.
-
Never
leave
the
appliance unsupervised
while
it
is
operating.
-Make sure you know the application times
for
the substances and the
quantities necessary to
treat
the area in question,
as
this will make the
task easier. Walk through the area
to
be
treated slowly, taking into
account the application time, starting from the point furthest from the
exit and moving towards this. This reduces the exposure time
to
the
substance
to
the minimum.
-Always keep a minimum distance
of
1
meter
between the nozzle and
all objects. Short bursts aimed
at
a suspected
or
known contaminated
area are
an
acceptable procedure and should leave no traces
of
the
substance on the surfaces.
- 8 -

Bda
Neburotor engl.
7/02
-Leave the aerosol
to
rest
for
as
much
time
as
possible before aerating
the area treated (preferably 2-6 hours, with a minimum
limit
of
one
hour).
-Accommodate
to
the
circumstance
that
the
motor
is open and
not
suitable
to
let
pass fog
or
other
aggressive mediums!
-
An
optimum distribution rate
is
30
mi/minute
of
substance
approximately.
To
establish the application time, first determine the
total quantity
of
substance
to
be
used, in accordance with
the
following
formula:
(m
3
of
area
to
be
treated) x
(mi
substance required
for
1m
3) = ml
of
substance
ml
of
substance = distribution time in minutes
distribution in
mi/minute
OUTDOOR APPLICATIONS
Areas around homes, picnie areas, swimming pools etc. :
-The ideal results are obtained during the cooler times
of
the
day, such
as
early morning
or
evening, when insects are most active. The ideal
wind speed
is
between 5 and 10 km /
hOUL
If
the wind speed exceed
15 km / hour,
we
suggest
to
avoid fogging.
-Start
at
a point upwind
of
the area
to
be
treated and keep the nozzle
downwind
at
ehest high.
ImDortant!
All personnel exposed
to
the
aerosol should
wear
an
approved
breathing mask!
- 9 -

Bda Neburotor eng!.
7/02
9.)
Consumption
The
NEBUROTOR
is
fitted with a flow regulator which makes use
of
a system
for
the identification
of
the adjustment pin position (notch by notch
movement), means
that
you always know exactly how much liquid
is
being
issued, from a minimum
of
15
ce
to a maximum
of
200
ce
per minute,
depending on the type and viscosity level
of
the liquid
to
be
fogged.
As
an example, in the following table contains the mean distribution results,
obtained with the pin in the various positions, using both oil and water based
substances.
Irrespective
of
the product fogged, the
NEBUROTOR
always produces an
optimum spray with drops diameters between 1
to
30 microns. Drops
of
less
than 10 microns account
for
more than 70 %
of
the
total
quantity
produces,
and those around 20 microns are less than 10 0/0. These dimensions enable
the entire spray to the reach the
treatment
area, with maximum impact on
the insects.
A spray med up
of
excessively large drops, with diameters from 100
to
500
microns, is partly dispersed before.
it
reaches the
target
and there is a waste
of
product
even-
when
it
does come into contact with the insect.
In
the same
way a spray made up
of
drops smaller than 1 micron does not come
substantially into contact with the insect targeted.·
-10 -

~
~
,
AVERAGE
CONSUMPTION
VAL~eS
(ML
IMIN)
NEBUROTOR
.
)..:.".
:
(Test
tempf~rature:
22
Oe)
-'.'
.
;.
-';
.
WATER
KENYATOX
I<ENYAFOG
K E N Y
ASO
L
22;
.'
.
';;-~-"
Flow
regulator
Viscosity: 1,0 ° Engler Viscosity: 0,9 ° Engler
.
:"
.~
..:
~
..
Viscosity:
4,4
° Engler Viscosity: 3,8 ° Engler
needle position measured
at
20°C measured
at
20?C measured
at
20°C measured
at
20°C
ml
(1/
h) ml
(1/
h) ml
(1/
h) ml
(1/
h)
Maximum opening 180 (11) 200 (12) 80 (4,8) 85 (5,1)
Meduim opening 135 (8) 150
(9)
60 (3,6) 65 (3,9)
Minimum opening 30 (1,8) 50 (3)
10
(0,6)
15
.(0,9)
~~.
;
------
DJ
Q.
GI
Z
tD
er
&:
~
o
.,
tD
::J
12,
~
·0
IV

Bda
Neburotor eng!.
7/02
Periodically check the condition
of
the air
filter
(14)
Fog
warm
water
after
use
to
remove
any
residues
of
solution!
Open
flow
regulator
(29)
completely!
-
12
-
2.9

Ersatzteiliste
für
IGEBA -tragbares Kaltnebelgerät "NEBUROTOR"
Spare parts
list
for
IGEBA -portable cold fogger "NEBUROTOR"
Bei Ersatzteilbestellungen bitte Pos. Nr., Teilebezeichnung, Teile Nr.,
und
Geräte
Nr.
angeben!
In
case
of
order please give Pos.No.,
part
name,
part
number
and
serial
number!
Pos.Nr. Teile-Nr./ Bezeichnung I
N°
Pos
N°
Part-Nr. Part name
1 7650013 Motor Dichtung / Motor Gasket 1
2 7612110 Elektromotor NEBUROTOR, kpl. 110-120 V. 50/60 Hz. 1
Electric motor NEBUROTOR, cpl. 110-120
V.
50/60
Hz.
2 7612240 Elektromotor NEBUROTOR, kpl. 220-240 V. 50/60 Hz. 1
Electric motor NEBUROTOR, cpl. 220-240
V.
50/60
Hz.
3 7600140 Handgriff kpl. / Handle cpl. (NEBULO/NEBUROTOR) 1
3 7600145 Handgriff kpl. / Handle cpl. (NEBULO/NEBUROTOR) -UK 1
4 7650012 Schneidschraube / Selftapping screw 3,5 x 10 -TORX 2
5 7600610 Gehäuse NEBUROTOR / NEBUROTOR -body 1
6 7703035 Schneidschraube / Selftapping screw 3x35 2
7 7600036 Spannring / Closure ring 1
8 7600074 Verschluß /Iocking device -HEYCO
DP
187 2
9 7600057 Anschlagstange Messing lang / Stop pin, brass, long 1
10 7600058 Deckplatte / Cover plate (NEBUROTOR) 1
11
7793504 Scheibe / Washer,
11)
4 - DIN 125 1
12
7600059 Selbstsichernde Mutter / Self locking
nut,
M4 -DIN 985 1
13 7600039 Tank / Reservoir(NEBULO/NEBUROTOR) 1
14 7600003 Luftfilter / Air filter 108 x 75 x 64 1
15 7703520 Schneidschraube / Selftapping screw 3,5 x 20 -UNI 9707 4
16 7650004 Filtergehäuse / Air filter support 1
17 7725320 Senkschraube / Screw M3 x 20 -DIN 965 2
18 7600014 Kabeldurchführung / Cable gland 2
19 7650024 Winkelverschraubung / Elbow pipe connector
11)
8 -1/8 1
20 7793504 Scheibe / Washer
11)
-DIN 125 4
21
7600059 Selbstsichernde Mutter / Self locking nut M4 -DIN 985 4
22 7650098 Tankdichtung VITON / Reservoir gasket VITON 1
23 7600001 Linsenkopfschraube / Lens head screw M6 x 12 -DIN 7985 1
24 7650002 Filterdeckel/Air filter cover 1
25 7600023 Produkt Schlauch / Feeding pipe (NEBULO/NEBUROTOR) 1
26 7600020 Düse / Nozzle 1
27 7600015 Zerstäuber / Atomizer 1
28 7703995 Schneidschraube / Selftapping screw 3,9 x 9,5 -UNI
7981
4
05/2007

Ersatzteiliste
für
IGEBA -tragbares Kaltnebelgerät "NEBUROTOR"
Spare parts
list
for
IGEBA -portable cold fogger "NEBUROTOR"
Bei Ersatzteilbestellungen bitte Pos. Nr., Teilebezeichnung, Teile Nr.,
und
Geräte Nr.
angeben!
In
case of order please give Pos.No.,
part
name,
part
number
and
serial
number!
Pos.Nr. Teile-Nr./ Bezeichnung I
N°
Pos
N°
Part-Nr. Part name
29 7670025 Regulierventil/ Flow regulator (NEBUROTOR) 1
30 7650024 Winkelverschraubung / Elbow pipe connector
121
8 - 1/8 1
31
7600055 Zylinderschraube / Screw M4 x 16 -DIN 912 2
32 7600110 Getriebe / Reduction Gear 110-120 V. 50/60 Hz. 1
33 7600220 Getriebe / Reduction Gear 220-240 V. 50/60 Hz. 1
34 7600059 Selbstsichernde Mutter / Self locking nut M4 -DIN 985 1
35 7793504 Scheibe / Washer
1214
DIN 125 1
36 7600051 Gehäuse / Base connecting box (NEBUROTOR) 1
37 7600052 Messingstange, kurz
lpin,
brass, short 1
38 7793504 Scheibe / Washer
121
4 - DIN 125 2
39 7600059 Selbstsichernde Mutter / Self locking nut
M4
-DIN 985 2
40 7600053 Lager, DELRIN / Friction bearing, DELRIN 1
41
7600055 Zylinderschraube / Screw, M4 x 16 -DIN 912 4
42 7600054 Flansch / Coupling flange (NEBUROTOR) 1
43 7600056 Seegering / Seeger 1
44 7600046 Produktschlauch / feeding pipe (NEBUROTOR) 1
45 7650035 Produktfilter/ Solution filter (NEBUROTOR) 1
05/2007

1--
2
NEBURorOR
14
-~
15
16
26
27
44
V45
~
05/2007
Table of contents
Other IGEBA Fog Machine manuals
Popular Fog Machine manuals by other brands

SmokeCloak
SmokeCloak EASY 2200 Installation and operating instructions

Look Solutions
Look Solutions UNIQUE 2 operating manual

Velleman
Velleman HQ POWER VDP1500SSM2 user manual

Antari
Antari M-1 user manual

Chauvet
Chauvet Hurricane Haze 2D Quick reference guide

UR FOG