IKI Pillar IKI 4,5 kW User manual

Instructionsforinstallationanduse
IKIelectricheaters4,5‐12kW
withaseparatecontrolunit
PillarIKI4,5kW
PillarIKI6kW
PillarIKI7,5kW
PillarIKI9kW
PillarIKI10kW
PillarIKI12kW
05/2015

Instructionsforinstallationanduse|IKIelectricheaterwithseparatecontrolunit Sivu1
Thisinstructionmanualisintendedforthesaunaownerorthepersoninchargeofcaringforthe
operationofthesauna,aswellasfortheelectricianwhoinstallstheheater.Whentheinstallation
iscompletetheseinstructionsmustbegiventotheownerorthepersoncaringforthesauna.The
saunaheaterisintendedforthesolepurposeofheatingthesaunaroomtoatemperature
appropriateforbathing.Itsuseforanyotherpurposeisprohibited.
Beforeyoubegininstallingtheheater,payattentiontothefollowing
points:
Bewareofthesharpedgesofthestainlesssteelmesh.Usealong‐sleeved
shirtandprotectiveglovesduringtheinstallation.
Readthroughthisinstallationmanualbeforeyoubegintheinstallationofthe
heater.
Thewarrantydoesnotcoverdefectscausedbyfaultyinstallationormisuseof
theheater.
Technicalsupport
(Mon‐Fri9‐16)
+358(0)600550133
(1,49€/min+I.c.c.)
IKI‐KiuasOy
Hakaniemenkatu11
00530Helsinki
Production
Niilontie10
76150Pieksämäki
YHTEY
S
TIED
O

Instructionsforinstallationanduse|IKIelectricheaterwithseparatecontrolunit Sivu2
Sisältö
Installationoftheheater...................................................................................................................................3
Connectingtheheatertotheelectricalnetwork..............................................................................................4
Tableofheatermodels......................................................................................................................................6
Safetydistances.................................................................................................................................................6
Requirementsforwaterquality........................................................................................................................7
Instructionsforuse............................................................................................................................................7
Trouble‐shooting...............................................................................................................................................7
Warranty............................................................................................................................................................8
Qualityquarantee/Freightquarantee.............................................................................................................9
Mechanicalventilation....................................................................................................................................10
Warnings..........................................................................................................................................................11

Instructionsforinstallationanduse|IKIelectricheaterwithseparatecontrolunit Sivu3
Installationoftheheater
1. Removetheplasticwrappingfromaroundtheheater.
2. Choosetheplacefortheheateraccordingtotherequiredsafetydistances(page6).
3. Considerthelocationoftheairvent,thermostatandcontrolunit(seeinstructionsforthecontrol
unit.)
4. Adjustthelegsofthestainlesssteelbasesoitiscompletelylevel.
5. Removethebaseplatefromtheundersideoftheheaterandconnectthefivepoleelectriccableto
theconnectionstripinsidetheelementboxaccordingtothecircuitconnectordiagram(page5).
6. Leadthecablethroughthejunctionboxontotheconrolunitandaffixaccordingtotheinstructions
inthecontrolunit.
7. Testthatalltheheatingelementsfunctionproperly.Ifalltheresistorsheatup,closetheelement
boxpanel.Ifproblemsoccur,contactthemanufacturer'stechnicalsupport.
8. Placethelowerpartofthestainlesssteelmeshframearoundtheheatingelements,sothatitisan
equaldistancefromalltheheatingelements.Checkthattheheatingelementsstandupstraight.If
theyhavebeenbent,carefullystraightenthem.
9. PILINGOFTHESTONES:Washthestonesbeforepiling.Detachthetwostainlesssteelmeshframes
fromoneanother(excludingthePillarIKI7,5kWheatermodel).Pilestonestothelowerpartofthe
frame.Oncethelowerparthasbeenfilledwithstones,reattachtheupperpartoftheframe.Pile
stonestothefilltheupperpart.Theheatingelementsshouldbecarefullycovered.Pleasemake
surethatelementsmakeNOTcontactwitheachotherorwiththeheaterframe.Olivine,olivine‐
doleriteandperidotitestonesarerecommended,insizessmallerthan10cmindiameter.The
stonesshouldnotbeplacedtootightlytogetherallowingforfreeairflowbetweenthestones.In
communallyorpubliclyusedsaunaswerecommendtheuseofceramicKerkesstonesaroundthe
heatingelements(www.kerkes.fi).Kerkesstonessupportandhelppreservetheresistorsandthey
donotdisintegrateprematurelyduetohightemperaturechanges.Notethattheuseofsoapstone
andnaturalstonesisallowedonlyontheouteredgesandonthetopoftheheater.
10. Werecommendtheuseofsafetyrailingsaroundtheheater.However,thestainlesssteelmesh
framedoesnotover‐heatthewayordinarysteel‐casedheatersdo.
11. Thesurfaceofthestonessinksinalittleaftertheheaterisinuse.Frequentlycheckthatthe
heatingelementsdonotbecomeexposed.Ifthisshouldhappen,pileinmorestones.The
disintegrationofthestonesdependsonthetypeofstonesandthefrequencyofuse.Thecondition
ofthestonesshouldbecheckedyearlyandbrokenstonesmustbereplacedwithnewones.

Instructionsforinstallationanduse|IKIelectricheaterwithseparatecontrolunit Sivu4
Connectingtheheatertotheelectricalnetwork
Theheaterisconnectedtotheelectricalnetworksemi‐stationarilywithanH07RN‐Frubbercableoran
equivalent.TheuseofPVC‐insulatedcableasaconnectingcableisprohibitedduetothermal
embrittlement.Theelectricinstallationmayonlybeadministeredbyaqualifiedelectricianadheringto
currentregulations.Themaximumdistanceofthejunctionboxfromtheflooris400mm,measuredfrom
theuppercornerofthebox.Makesurethattheconnectingcablewillnotbeexposedtothermalradiation
ormechanicalstrain.Iftherubbercablerunninginsidethewallofthesaunaisabove1000mmfromthe
floor,itneedstoenduretemperaturesupto170degreesCelsius(forexampleSSJ).
Controlunit
Refertotheseparateinstructionsforinstallationprovidedbythemanufacturerofthecontrolunit.
Sauna‐roomtemperaturesensorandover‐heatpreventionfuse
Thesensorshouldbelocated
‐toawall:
10cmdownfromceiling
10‐30cmfromouteredgeofheater
‐totheceiling:
‐‐10‐30cmfromouteredgeofheater
‐minimumof1000mmdistancefromundirectedventforreplacementair,orminimumof500mm
distancefromtheairventdirectedawayfromthesensor.
Thetemperaturerestrictorswitchesoffthepowerifthetemperatureinthesaunaclimbsdangerouslyhigh
(139degreesCelsius)duetoamalfunction.

Instructionsforinstallationanduse|IKIelectricheaterwithseparatecontrolunit Sivu5
Heatermodelversioninputfusecable
power power power
kW +kW +kW pcspcsxfusesizepcsxcabletype
IKI 4,5 33x10A5x2,5S(tai5x1,5S)
IKI 6 33x10A5x2,5S(tai5x1,5S)
IKI 7,5 33x16A5x2,5S
IKI 9 33x16A5x2,5S
IKI 10 33x16A5x2,5S
5 + 5 double 66x10A2x5x2,5S(tai2x5x1,5S)
IKI 12 33x20A5x6S
6 + 6 double66x10A2x5x2,5S(tai2x5x1,5S)

Instructionsforinstallationanduse|IKIelectricheaterwithseparatecontrolunit Sivu6
Tableofheatermodels
Kiuas
Sizeof
sauna
Heater
height
Heater
diameter
Max.amount
ofstones
Wattage
PillarIKI4,5kW3‐6m³120cm26cm80kg4,5kW
PillarIKI6kW5‐9m³140cm26cm100kg6kW
PillarIKI7,5kW7‐12m³105cm34cm140kg7,5kW
PillarIKI9kW8‐16m³120cm34cm150kg9kW
PillarIKI10kW10‐18m³125cm34cm170kg10kW
PillarIKI12kW14‐24m³140cm34cm180kg12kW
Safetydistances
toinflammablematerias(suchaswall‐pannelingandbenches)
Kiuas
Front
Sides
Back
Up
PillarIKI4,5kW10cm10cm10cm60cm
PillarIKI6kW10cm10cm10cm60cm
PillarIKI7,5kW10cm10cm10cm80cm
PillarIKI9kW10cm10cm10cm80cm
PillarIKI10kW10cm10cm10cm80cm
PillarIKI12kW10cm10cm10cm80cm
Supportingtheheateragainstawall
O
p
tion1)IstallationinacornerO
p
tion2)Istallationa
g
ainstawall

Instructionsforinstallationanduse|IKIelectricheaterwithseparatecontrolunit Sivu7
Requirementsforwaterquality
WatertypeEffectRecommendation
HumusconcentrationColor,taste,precipitates<12mg/l
RautapitoinenvesiColor,smell,taste,
precipitates
<0,2mg/l
Hardness:mostimportantsubstances
aremanganese(Mn)andlime,i.e.
calsium(Ca)
PrecipitatesMn:<0,05mg/l
Ca:<100mg/l
ChlorinatedwaterRisktohealthForbidden
SeawaterFastcorrosionForbidden
Instructionsforuse
Beforebathingforthefirsttime,heatuptheheateroncetoburnofftheprotectiveoilsolvents.Be
carefultoairoutthesaunaroomefficientlyafterwards.
Theheatingtimeisabout45–75minutesdependingonthesizeoftheroomanditsventilation.
RecommendedtemperatureforIKIstonepillarsis50–70degrees.Pouringwaterontheheater
increasestemperatureandhumidity.Youcancontroltheheatandhumiditybypouringthewater
todifferentpartsoftheheater.
Thetemperatureshouldbesettothedesiredrangefromthetemperatureknobinthecontrolunit.
Checkthattheheatingelementsdonotbecomeexposedasthestonesshiftaboutduetoheat
expansion.
Checktheconditionofthestonesonceayear,andcleanandreplaceasnecessary.
Donotthrowwatertotheheaterwhentherearepeoplenearby:thesteamcomingofftheheater
isburninghot.Donotthrowtoomuchwaterontotheheater.Maximumamountishalfalitreata
time.
Trouble‐shooting
Iftheheaterorsaunaroomdoesnotheatup,checkthat:
Thepowerison
Thetimerissettotheoperatingrange
Thetemperatureknobissettoahighertemperaturethanthetemperatureinthesaunaroom
Thefusesareintact
Thetemperaturerestrictor(overheatprotector)hasnotgoneoff.Iftemperaturerestrictorhas
goneoff,thereasonforthismustbesolvedbeforeusingheateragain
Thestonesarepiledcorrectly
Ifthewoodenwalls/partstakeonadarkershade,checksafetydistancesandpilingofthestonesdoesnot
leaveresistorexposedortouchingoneanother.Iftheresistorsarevisibletheyemitexcessiveheat.

Instructionsforinstallationanduse|IKIelectricheaterwithseparatecontrolunit Sivu8
Warranty
IKI‐KiuasLtd(themanufacturer)assuresawarrantytoitsproductsasstipulatedhere,guaranteeingthe
qualityandfunctionalityoftheproductsduringthewarrantyperiod.Thewarrantyappliestoheaterssold
andusedinFinland.Thewarrantyrequiresthatthebuyerfollowtheinstructionsregardingtheplacement
oftheheater,itsinstallation,useandmaintenanceaswellasthoseregardingthequalitiesofthestones
usedintheheater.Thelengthofthewarrantyperiodis24monthfromthedayofpurchaseorfromtheday
ofpurchase.Thewarrantyperiodforspasaunasandotherpublic‐usesaunasis6months,ordetermined
accordingtothefrequencyofuse.Contactthemanufacturerformoredetails.
Thewarrantyforelectricheatersrequiresthat:
1Incaseofdefectormalfunction,thebuyermustalwayscontactthemanufactureror
salesagentbeforesearchingforthecauseorattemptingtorepairit.Anyrepairsmustbe
agreeduponinwritingwiththemanufacturer.
2Inprivateapartmentuse,theheater’sstonespaceneedstocleanedoutandre‐piledat
leastonceayearandweatheredstonesneedtobereplacedwithnewones.
3Ininstitutionalorprofessionaluse,theheater’sstonesmustbere‐piledatleastthree
timesayearduringthewarrantyperiod.Ifthisisnotdone,thewarrantyceasestoapply.
Inaddition,thestonesmustbechangedtonewonesatleastonceayear.Proof,suchas
theproduct’spurchasereceipt,mustbepresentedatrequest.Theuseofceramicheater
stones(otherthanthoseformKerkes)isprohibited.
4Thewarrantydoesnotcoverdismantlementorreinstallationonsaunabenches,removal
ofsaunastonesnorre‐pilingthem.IKI‐Kiuasrecommendsusingforthelowerlevels
saunabenchesthatcanbemovedwithoutusingtoolstodismantlestructures.
5Thewarrantyforreplacementpartsis12monthsfromthedayofpurchase.The
replacementforthedamagedpartwillbedeliveredtothesalesagentcostfree.The
installationofthereplacementpartmustbecarriedoutbyamechanicthathasbeen
approvedbythemanufacturer.Themanufacturerisnotliabletoreimburseanycosts
duetotheremovalofthefaultypartortheinstallationofthereplacement.Thefaulty
partmustbereturnedtothemanufactureratrequestandattheirexpense.The
manufacturerwillissueitsfreightcontactsnumberforthedeliveryofthefaultypart.
Receiptfromtheresellerorcertificatefromamanufacturer’sauthorizedmechanicwill
functionasawarrantycertificate.
6WarrantybasedontheconditionssetbyTheElectricalContractors´Associationof
FinlandSTUL.STUL‐warrantyappliestoelectricheatersandcontrolunitsifagreedupon
inwriting.Insuchcases,theconditionsSTULhassetareattachedtothesewarranty
conditions.WhentheuseofSTULwarrantyhasbeenagreedupon,theysupersedethese
warrantyregulations,ifcontradictory.
7Limitationstowarranty:Theproductownermusttakegoodcareoftheproduct.On
receivingtheproduct,theownerisexpectedtocheckthatitdoesnotshowsignsof
damagecausedduringshippingorstorage.Incaseofsuchdamage,theymustcontact
thesalesagentortransportcompanyimmediately.Themanufacturerisnotliablefor
anydamagescausedduringshipping,orbyinappropriatestorage,installationoruse
againstmanufacturer’sinstructions,neglectofmaintenance,ordamagecausedby
placementoftheheaterinaplacewhichdoesnotmeettherecommendationsmadeby
themanufacturer.
8Damagenotifications:Theownerisresponsiblefornotifyingthemanufacturer,thesales
agent,ormanufacturer’sauthorizedmechanicofanydamageormalfunctionassoonas
itappearsandwithin14days.Anywarrantyrelatedclaimsmustbesubmittedwithin14
daysfromtheclosingdateoftheproduct’swarrantyperiod.

Instructionsforinstallationanduse|IKIelectricheaterwithseparatecontrolunit Sivu9
9Manufacturer’sactionsregardingwarranty,continuationofwarranty:Inreceiptofa
substantiatedwarrantyclaim,themanufacturerwillrepairorchangetheproduct.Thisis
doneinthemanufacturer’sexpense,andthemanufacturerisfreetoselectthemost
cost‐effectivealternative.Thewarrantyforreplacementpartsisoutlinedabove.The
replacementpartisgrantedwarrantyaccordingtospecifications.Thewarrantyfora
repairedpartcontinuesasbefore.
Themanufacturerisnotliableforreimbursinganyexpenses,businesslossorotherdirectorindirectharm
occurredtothebuyerfromdamagesormalfunction.
Qualityquarantee/Freightquarantee
Guaranteeofmaterials.Themanufacturerguaranteesthedurabilityofthestainlesssteelparts(resistor
platformandframe)inprivatehomeusefor10years.Duringthewarrantyperiodanydefectsthatappear
intheheater'srawmaterialsorareproduction‐basedwillberepairedfreeofcharge.Forexample,theuse
ofseawaterontheheaterisforbidden.Readthroughtherequirementsforwaterqualityintheinstallations
instructions.
Thewarrantydoesnotcovercolourchanges,slippingorhair‐linefractures,characteristictonaturalstones,
whichdonotaffecttheuseorthesafetyoftheheater.
Damagesoccurredwhileshippingmusttoberecordedinthewaybillwhentheproductisreceivedorwithin
7daysofdelivery.Shippingdamagemustalsoalwaysbereportedtotheshippingcompany’slastcontact.
Thedamagedpartneedstobestoredforinspection.Insurancecompensatesforthenewpart,whichwill
bedeliveredbyapublictransporter.Inallissuesconcerningwarrantycontactthestoretheproductwas
boughtfrom.

Instructionsforinstallationanduse|IKIelectricheaterwithseparatecontrolunit Sivu10
Mechanicalventilation
Theventilationinthesaunaroomneedstobeconsidered.Properair‐flowallowsbatherstoenjoyfresh,
oxygen‐richair.Theairshouldfullychange6timesanhour.Thesupplyairinletshouldbeinstalledonthewall
ortheceilingatabout500mmabovetheheater.Thesupplyairinletventshouldbe50‐100mmindiameter.The
outletventshouldbelocatedasfarawayfromtheheateraspossible,closetothefloor.Theoutletventshouldbe
twicethesizeoftheinletvent.
NOTE!Thesensorforthethermostatshouldbelocatedataminimumof1000mmdistancefrom
undirectedventforreplacementair,orminimumof500mmdistancefromtheairventdirectedawayfrom
thesensor.

Instructionsforinstallationanduse|IKIelectricheaterwithseparatecontrolunit Sivu11
Warnings
1. Stayinginthehotsaunaforlongperiodsincreasesbodytemperature,which
maybedangerous.
2. Keepawayfromtheheaterwhenit'shot.Thestonesandoutersurfaceofthe
heatermayburn.
3. Preventchildrenfromgettingclosetotheheater.
4. Donotleavechildren,handicappedorillpeopletousethesaunawithout
supervision.
5. Consultyourdoctoraboutanyhealthconcernsregardingsauna‐bathing.
6. Consultchildwelfareclinicabouttakinglittlebabiestothesauna.
7. Alwaysmovecarefullyinthesauna,asthebenchesandfloorsmaybe
slippery.
8. Nevergotoahotsaunaundertheinfluenceofalcohol,medicationor
narcotics.
9. Neversleepinahotsauna.
10.Sea‐airandahumidclimatemaycorrodethemetalsurfacesoftheheater.
11.Donothangclothestodryinthesauna,asthismaycauseariskoffire.
Excessivemoisturecontentmayalsocausedamagetotheelectrical
equipment.