Imagine IPA6800+ Quick guide

IPA6800+
ASI on IP Video Gateway
Release 1.2.0 Revision A
May 2016
Installation, Configuration, and
Operation Manual

IPA6800+ ASI on IP Video Gateway Installation, Configuration, and Operation Manual
© 2016 Imagine Communications Corp. Proprietary and Confidential. Release 1.2.0 Revision A | Page 2
Publication Information
© 2016 Imagine Communications Corp.
Proprietary and Confidential.
Imagine Communications considers this document and its contents to be proprietary and confidential.
Except for making a reasonable number of copies for your own internal use, you may not reproduce this
publication, or any part thereof, in any form, by any method, for any purpose, or in any language other
than English without the written consent of Imagine Communications. All others uses are illegal.
This publication is designed to assist in the use of the product as it exists on the date of publication of
this manual, and may not reflect the product at the current time or an unknown time in the future. This
publication does not in any way warrant description accuracy or guarantee the use for the product to
which it refers. Imagine Communications reserves the right, without notice to make such changes in
equipment, design, specifications, components, or documentation as progress may warrant to improve
the performance of the product.
Trademarks
Magellan CCS Navigator™, Selenio 6800+™ are trademarks or trade names of Imagine Communications
or its subsidiaries.
Microsoft® and Windows® are registered trademarks of Microsoft Corporation. All other trademarks and
trade names are the property of their respective companies.
Contact Information
Imagine Communications has office locations around the world. For domestic and international location
and contact information, visit our Contact page (http://www.imaginecommunications.com/how-
buy/contact-us).
Support Contact Information
For domestic and international support contact information see:
Support Contacts (http://www.imaginecommunications.com/how-buy/contact-us)
Worldwide Support e-mail (mailto: service@imaginecommunications.com)
Customer Community Portal (http://app.imaginecommunications.com/customercommunity)
Warranty & Contract Information (http://www.imaginecommunications.com/services/customer-
care)
MyImagine Academy Training (http://www.imaginecommunications-academy.com)
Product Manuals (http://www.imaginecommunications.com/services/product-manuals)

IPA6800+
Installation, Configuration, and Operation Manual Contents
© 2016 Imagine Communications Corp. Proprietary and Confidential. Release 1.2.0 Revision A | Page 3
Contents
Preface................................................................................................................... 5
Manual Information .................................................................................................................................5
Purpose.................................................................................................................................................5
Audience...............................................................................................................................................5
Writing Conventions............................................................................................................................. 5
Obtaining Documents...........................................................................................................................6
Unpacking/Shipping Information ............................................................................................................. 6
Unpacking a Product ............................................................................................................................6
Product Servicing.................................................................................................................................. 6
Returning a Product ............................................................................................................................. 6
Safety........................................................................................................................................................7
Safety Terms and Symbols in this Manual ...........................................................................................7
Restriction on Hazardous Substances (RoHS) Compliance.......................................................................7
Waste from Electrical and Electronic Equipment (WEEE) Compliance ....................................................8
IPA6800+ Module and I/O Interface ...................................................................... 9
Overview................................................................................................................................................... 9
Module Description................................................................................................................................10
IPA6800++R Back Connector..............................................................................................................10
IPA6800+ Front Module .....................................................................................................................11
Electrical Interfaces ................................................................................................................................12
ASI Out................................................................................................................................................12
ASI In...................................................................................................................................................12
Ethernet Interface ..............................................................................................................................13
Signal Flow..............................................................................................................................................13
Part Numbers..........................................................................................................................................14
Installation and Navigator Discovery.................................................................... 15
Maximum 6800+ Frame Power Ratings .................................................................................................15
How to Prepare the Product for Installation..........................................................................................15
Module Information ...............................................................................................................................16
Required Frames and Back Connector Types.....................................................................................16
Installing and Removing Application Modules...................................................................................16

IPA6800+
Installation, Configuration, and Operation Manual Contents
© 2016 Imagine Communications Corp. Proprietary and Confidential. Release 1.2.0 Revision A | Page 4
How to Perform a Discovery of the Module in Navigator..................................................................16
Firmware Upgrade............................................................................................... 18
Procedure ...............................................................................................................................................18
How to Monitor a Software Upgrade.....................................................................................................19
Operation ............................................................................................................ 21
How Commands Are Documented for Both Craft and Navigator ..........................................................21
Navigator Configuration Recommendation ...........................................................................................21
General Operating Procedures...............................................................................................................22
How Parameter Changes are Applied ................................................................................................22
How to Check Hardware and Software Versions ...............................................................................23
Configuration Procedures.......................................................................................................................23
How to Transmit Video Over an IP Stream ........................................................................................23
How to Extract Video from an IP Stream ...........................................................................................24
How to Monitor Module Alarms ........................................................................................................24
Configuration and Status Parameters .................................................................. 25
Overview.................................................................................................................................................25
Command Groups...................................................................................................................................25
IPA6800+ Parameters.............................................................................................................................25
How to Use Telnet..............................................................................................................................25
Parameter Usage Notes .....................................................................................................................25
Remote Control Parameters...............................................................................................................26
Status Parameters ..............................................................................................................................27
Utility Commands...............................................................................................................................28
Alarm Commands...............................................................................................................................29
Specifications....................................................................................................... 30
Electrical Specifications ..........................................................................................................................30
Physical Specifications............................................................................................................................30
Regulatory Compliance...........................................................................................................................31
Software Communication Problems .................................................................... 32
Hardware Communication Problems ................................................................... 35

IPA6800+
Installation, Configuration, and Operation Manual Preface
© 2016 Imagine Communications Corp. Proprietary and Confidential. Release 1.2.0 Revision A | Page 5
Preface
Manual Information
Purpose
This manual details the features, installation, operation, maintenance, and specifications for the
IPA6800+.
Audience
This manual is written for engineers, technicians, and operators responsible for installation, setup,
maintenance, and/or operation of the IPA6800+.
Writing Conventions
This manual adheres to the following writing conventions.
Term or Convention
Description
Bold
Indicates dialog box, property sheet, field, button, check box,
list box, combo box, menu, submenu, window, list, and
selection names
Italics
Indicates email addresses, names of books and publications,
and first instances of new terms and specialized words that
need emphasis
CAPS
Indicates a specific key on the keyboard, such as ENTER, TAB,
CTRL, ALT, DELETE
Code
Indicates variables or command-line entries or something you
type into a field.
>
Indicates the direction of navigation through a hierarchy of
menus and windows
hyperlink
Indicates a jump to another location within the electronic
document or elsewhere
Internet address
Indicates a jump to a Web site or URL

IPA6800+
Installation, Configuration, and Operation Manual Preface
© 2016 Imagine Communications Corp. Proprietary and Confidential. Release 1.2.0 Revision A | Page 6
Obtaining Documents
Product support documents can be viewed or downloaded from our website. Alternatively, contact your
Customer Service representative to request a document.
Unpacking/Shipping Information
Unpacking a Product
This product was carefully inspected, tested, and calibrated before shipment to ensure years of stable
and trouble-free service.
1. Check equipment for any visible damage that may have occurred during transit.
2. Confirm that you have received all items listed on the packing list.
3. Contact your dealer if any item on the packing list is missing.
4. Contact the carrier if any item is damaged.
5. Remove all packaging material from the product and its associated components before you install
the unit.
Keep at least one set of original packaging, in the event that you need to return a product for servicing.
Product Servicing
Except for firmware upgrades, modules are not designed for field servicing. All hardware upgrades,
modifications, or repairs require you to return the modules to the Customer Service center.
Returning a Product
In the unlikely event that your product fails to operate properly, please contact Customer Service to
obtain a Return Authorization (RA) number, and then send the unit back for servicing.
Keep at least one set of original packaging in the event that a product needs to be returned for service.
If the original package is not available, you can supply your own packaging as long as it meets the
following criteria:
The packaging must be able to withstand the product’s weight.
The product must be held rigid within the packaging.
There must be at least 2 in. (5 cm) of space between the product and the container.
The corners of the product must be protected.
Ship products back to us for servicing prepaid and, if possible, in the original packaging material. If the
product is still within the warranty period, we will return the product prepaid after servicing.

IPA6800+
Installation, Configuration, and Operation Manual Preface
© 2016 Imagine Communications Corp. Proprietary and Confidential. Release 1.2.0 Revision A | Page 7
Safety
Carefully review all safety precautions to avoid injury and prevent damage to this product or any
products connected to it. If this product is rack-mountable, it should be mounted in an appropriate rack
using the rack-mounting positions and rear support guides provided. It is recommended that each frame
be connected to a separate electrical circuit for protection against circuit overloading. If this product
relies on forced air cooling, it is recommended that all obstructions to the air flow be removed prior to
mounting the frame in the rack.
If this product has a provision for external earth grounding, it is recommended that the frame be
grounded to earth via the protective earth ground on the rear panel.
IMPORTANT! Only qualified personnel should perform service procedures.
Safety Terms and Symbols in this Manual
WARNING
Statements identifying conditions or practices that may result in
personal injury or loss of life. High voltage is present.
CAUTION
Statements identifying conditions or practices that can result in
damage to the equipment or other property.
Restriction on Hazardous Substances (RoHS)
Compliance
Directive 2011/65/EU (RoHS 2)—commonly known as the European Union (EU) Restriction on
Hazardous Substances (RoHS)—sets limits on the use of certain substances found in electrical and
electronic equipment. The intent of this legislation is to reduce the amount of hazardous chemicals that
may leach out of landfill sites or otherwise contaminate the environment during end-of-life recycling.
The Directive, which took effect on July 1, 2006, refers to the following hazardous substances:
Lead (Pb)
Mercury (Hg)
Cadmium (Cd)
Hexavalent Chromium (Cr-V1)
Polybrominated Biphenyls (PBB)
Polybrominated Diphenyl Ethers (PBDE)

IPA6800+
Installation, Configuration, and Operation Manual IPA6800+ Module and I/O Interface
© 2016 Imagine Communications Corp. Proprietary and Confidential. Release 1.2.0 Revision A | Page 8
According to this EU Directive, all products sold in the European Union will be fully RoHS-compliant and
“lead-free.” (See our website for more information.) Spare parts supplied for the repair and upgrade of
equipment sold before July 1, 2006 are exempt from the legislation. Equipment that complies with the
EU directive will be marked with a RoHS-compliant emblem.
Waste from Electrical and Electronic
Equipment (WEEE) Compliance
The European Union (EU) Directive 2002/96/EC on Waste from Electrical and Electronic Equipment
(WEEE) deals with the collection, treatment, recovery, and recycling of electrical and electronic waste
products. The objective of the WEEE Directive is to assign the responsibility for the disposal of
associated hazardous waste to either the producers or users of these products. As of August 13, 2005,
the producers or users of these products were required to recycle electrical and electronic equipment at
end of its useful life, and may not dispose of the equipment in landfills or by using other unapproved
methods. (Some EU member states may have different deadlines.)
In accordance with this EU Directive, companies selling electric or electronic devices in the EU will affix
labels indicating that such products must be properly recycled. (See our website for more information.)
Contact your local sales representative for information on returning these products for recycling.
Equipment that complies with the EU directive will be marked with a WEEE-compliant emblem.

IPA6800+
Installation, Configuration, and Operation Manual IPA6800+ Module and I/O Interface
© 2016 Imagine Communications Corp. Proprietary and Confidential. Release 1.2.0 Revision A | Page 9
IPA6800+ Module and I/O Interface
Overview
The IPA6800+ ASI on IP Video Gateway is part of Imagine Communications' 6800+ series of processing
and conversion modules.
IPA6800+ ASI on IP Video Gateway performs the following functions.
Encapsulates ASI into Gigabit Ethernet.
De-encapsulates ASI from Gigabit Ethernet.
Transmit Mode
In transmission mode, the IPA6800+ maps ASI into IP packets and applies Forward Error Correction (FEC)
to ensure the highest possible level of quality in network throughput.
Receive Mode
In receive mode, the IPA6800+ receives IP and uses Forward Error Correction (FEC) as needed, to
reconstruct the original ASI stream.
The IPA6800+ provides a card edge control for basic Ethernet IP address provisioning. Thereafter the
provisioning process may b e completed using Magellan CCS Navigator or Navigator provisioned with
the board’s IP address.
It offers:
Two (2) ASI video inputs conforming to DVB-ASI A011 Rev 1.0
Four (4) ASI video outputs. Outputs are paired. Each pair of BNCs presents the same signal on two
interfaces.
One (1) 1000 BaseT Ethernet Interface

IPA6800+
Installation, Configuration, and Operation Manual IPA6800+ Module and I/O Interface
© 2016 Imagine Communications Corp. Proprietary and Confidential. Release 1.2.0 Revision A | Page 10
Module Description
IPA6800++R Back Connector
The IPA6800++R double-slot back connector is used by the IPA6800+ when installed in a FR6802+ frame.
Table 1:
Item
Description
Full Description
1
ASI Input 1 & Input 2
Receives DVB-ASI-compliant transport stream input
2 & 3
ASI Outputs 1 & 2
Provides DVB-ASI transport stream output
4
-
Not Used
5
100 BaseT Ethernet

IPA6800+
Installation, Configuration, and Operation Manual IPA6800+ Module and I/O Interface
© 2016 Imagine Communications Corp. Proprietary and Confidential. Release 1.2.0 Revision A | Page 11
IPA6800+ Front Module
Table 2: IPA6800+ Front Module Card Edge Features
Feature
Description
1
Module Status LED
Indicates the module’s state of operation.
Off: The module is powered OFF. The module is not operational.
Red: The module is either booting or experiencing an error
Red (blinking): The module has booted in ‘safe mode’. See
‘Toggle Switch’ description below.
Amber: The module is booting
Green: The module is powered ON. The module is operating
properly.
2
Toggle Switch
This three-position toggle switch controls the card’s IP address
configuration.
Up (after boot): Forces the IP address for Telnet configuration
and control to 192.168.1.1
Up (at boot): Forces the module into ‘safe mode’
Center: The module operates using the configured IP address
Down: Disables Telnet access
3, 4
ASI LEDs
Each LED indicates the state of an ASI input interface.
Off: The module is powered Off or the interface is not configured
for use
Red: Loss of Signal (LOS) is detected
Amber: Errors are detected on the interface
Green: The interface is operating normally

IPA6800+
Installation, Configuration, and Operation Manual IPA6800+ Module and I/O Interface
© 2016 Imagine Communications Corp. Proprietary and Confidential. Release 1.2.0 Revision A | Page 12
Feature
Description
5
-
Not used
6
Error LED
Green: The module is operating normally
Red: An encapsulator or decapsulator alarm condition has
occurred within the last five seconds
7
Ethernet Speed LED
Indicates the Ethernet interface’s state of operation
Off: The Ethernet interface is either negotiating or experiencing
an LOS. Use the LINK LED below to fully identify the actual state
Green: The Ethernet interface is operating in 1000 BaseT mode.
Red: The Ethernet Interface is attempting to operate in half-
duplex mode or is operating in full-duplex at 10 Mbps
Amber: The Ethernet interface is operating in 100 BaseT mode
8
Ethernet Link LED
Indicates the Ethernet interface’s state of operation.
Off: The module is powered Off. The module is not operational.
Red: Indicates the interface is experiencing an LOS.
Green The Ethernet interface has established link-level
connectivity.
Amber The Ethernet interface is negotiating.
9
Ejector Handle
Used to eject the module from the 6800+.
Electrical Interfaces
ASI Out
The IPA6800+ can simultaneously provide two unique ASI signals. Each such signal is presented on two
BNC outputs. All ASI connections require 75-Ohm characteristic impedance coaxial cable. In general,
reliable operation can be achieved with cable lengths of up to 100 meters.
ASI In
The IPA6800+ can simultaneously receive two unique ASI signals. Each such signal is received through
either the ‘ASI 1 IN’ or the ‘ASI 2 IN’ interface. These two input interfaces support each ASI signal that
the IPA6800+ can put on IP. All ASI connections require 75-Ohm characteristic impedance coaxial cable.
In general, reliable operation can be achieved with cable lengths of up to 100 meters.

IPA6800+
Installation, Configuration, and Operation Manual IPA6800+ Module and I/O Interface
© 2016 Imagine Communications Corp. Proprietary and Confidential. Release 1.2.0 Revision A | Page 13
Ethernet Interface
Table 3: 1000 BaseT Ethernet Pin Out
Item
Pin
1000 BaseT
10/100 BaseT
1
1
Bi-directional Data A+
Transmit +
2
Bi-directional Data A
Transmit -
3
Bi-directional Data B+
Receive +
4
Bi-directional Data C+
-
5
Bi-directional Data C
-
6
Bi-directional Data B
Receive -
7
Bi-directional Data D+
--
8
8
Bi-directional Data D
Signal Flow

IPA6800+
Installation, Configuration, and Operation Manual IPA6800+ Module and I/O Interface
© 2016 Imagine Communications Corp. Proprietary and Confidential. Release 1.2.0 Revision A | Page 14
Part Numbers
Part Number
Description
IPA6800+D
ASI on IP Video Gateway –Bi-Directional Dual ASI to IP converter kit.
Complete kit includes:
One (1) IPA6800+ ASI on IP Video Gateway –Front Application Module
One (1) IPA6800+R ASI on IP Video Gateway –Rear Connector Module
IPA6800+
ASI on IP Video Gateway –Front Application Module:
Provides two (2) bi-directional (ASI to IP/IP to ASI) channels
IPA6800+R
ASI on IP Video Gateway –Rear Connector Module: Provides I/O for the
IPA6800+. Includes:
Two (2) ASI BNC Inputs
Four (4) ASI BNC Output Connectors (two identical signals for each
output channel)
One (1) Gigabit Ethernet Jack

IPA6800+
Installation, Configuration, and Operation Manual Installation and Navigator Discovery
© 2016 Imagine Communications Corp. Proprietary and Confidential. Release 1.2.0 Revision A | Page 15
Installation and Navigator Discovery
Caution: Before installing this product, read the 6800+ Series Safety Instructions and Standards Manual
shipped with every FR6802+ Frame Installation and Operation Manual or downloadable from our
website. This safety manual contains important information about the safe installation and operation of
6800+ series products.
This section describes the IPA6800+ installation process. See the FR6802+ Frame Installation and
Operation Manual for information about installing and operating a 6800+ frame and its components.
Maximum 6800+ Frame Power Ratings
This table describes the maximum allowable power ratings for 6800+ frames. Note the given maximums
before installing any 6800+ modules in your frame.
6800+ Frame Type
Max Frame Power
Dissipation
Number of Usable
Slots
Max Power
Dissipation per Slot
6800+XF –Frame with AC power supply
120 W
20
6 W
6800+XF –Frame with DC power supply
105 W
20
5.25 W
How to Prepare the Product for Installation
Perform the following steps before installing the IPA6800+.
Note: Contact your Customer Service representative if parts are missing or damaged Contact your
Customer Service representative if parts are missing or damaged.
1. Unpack the module
2. Check the equipment for any visible damage that may have occurred during transit.
3. Confirm receipt of all items on the packing list. The following items should be included.
4. Remove the anti-static shipping pouch, if present, and all other packaging material
5. Remove the anti-static shipping pouch, if present, and all other packaging material
IPA6800+
One IPA6800+ front application module
One double-slot back connector
One documentation and firmware CD
See Unpacking/Shipping Information (on page 6) for information about returning a product for servicing.

IPA6800+
Installation, Configuration, and Operation Manual Installation and Navigator Discovery
© 2016 Imagine Communications Corp. Proprietary and Confidential. Release 1.2.0 Revision A | Page 16
Module Information
Required Frames and Back Connector Types
The IPA6800+ module has a double-width back connector that can be installed in a 6800+XF. See the
6800+ Frame Installation and Operation Manual for installing back connectors in a 6800+ frame.
Installing and Removing Application Modules
These modules require no specialized installation or removal procedures. However, if installing both
front and rear modules, ensure that the back module is installed first before plugging in the front
module. When removing both the front and rear modules, ensure that the front module is unplugged
from the frame first, before removing the rear module.
See the 6800+ Frame Installation and Operation Manual for information about installing and
operating a 6800+ frame and its components.
See the 6800+ Safety Instructions and Standards Manual for important information about safely
installing your module.
Once the IPA6800+ module is installed, the appropriate input and output cables can be connected.
How to Perform a Discovery of the Module in Navigator
Use this procedure to cause Navigator to ‘Discover’ a recently-installed module.
1. Click Options > Discovery to open the Discovery Options dialog.
2. If the Products for Discovery column lists the frame containing the module you have just installed
(Note: Check the IP Address column as well to be sure) then…
a. Place a check mark in the Hosts column next to the module.
b. Click the Apply button, then click the OK button.
c. Skip to Step 4 below
3. If the frame of containing the module you have just installed is not listed, then click the Add…
button to open the Add Host dialog.
a. Enter the IP Address of the 6800-series shelf in the Host IP field.
b. Click the Options… button to open the Communication Settings dialog.
Choose the ‘Point-to-Point’ option from the Communication Type drop-down.
Click OK to dismiss the Communications Settings dialog.
c. Click OK to dismiss the Add Host dialog.
4. Click OK to dismiss the Discovery Options dialog.
5. If the Discovery Pane is not visible, click Tools > Discovery to reveal it.
6. Click the Start button to begin the Discovery session.
7. Wait until the Status window indicates “Discovery Completed”.
8. Click the Save button.

IPA6800+
Installation, Configuration, and Operation Manual Installation and Navigator Discovery
© 2016 Imagine Communications Corp. Proprietary and Confidential. Release 1.2.0 Revision A | Page 17
9. Drag the icons of any discovered pieces of equipment from the Discovery branch to of the
navigation tree to the Network branch.
10. Click the Save button to save the discovered items as network elements.
The discovered items are now ready for further configuration and monitoring.

IPA6800+
Installation, Configuration, and Operation Manual Firmware Upgrade
© 2016 Imagine Communications Corp. Proprietary and Confidential. Release 1.2.0 Revision A | Page 18
Firmware Upgrade
If a previous upgrade was interrupted and the module will not boot correctly, or if the module is in an
inoperable state
1. Move the toggle switch to the ‘up’ position.
2. Re-insert the module to cause it to boot in ‘safe mode’.
3. Proceed with the following upgrade procedure.
4. When the upgrade procedure is completed, move the toggle switch back to the ‘center’ position.
Procedure
1. Install the appropriate upgrade package from the CD-ROM or download it from the Imagine
Communications portal.
2. In Navigator, choose Tools > Software Upgrade. The Software Upgrade dialog opens and is brought
into the foreground.
3. On the New Transfer tab, click the Add button on the right. The Device Selection dialog opens.
4. In the Device Selection dialog
Expand the tree as needed to reveal the target device
Highlight the target device.
Click OK to close the Add Device dialog box.
Note: All items in a frame have the same IP address. Only one device from each IP address can be
added.
5. In the Software Upgrade dialog, click the Browse... button to open a standard Windows File
Selection dialog.

IPA6800+
Installation, Configuration, and Operation Manual Firmware Upgrade
© 2016 Imagine Communications Corp. Proprietary and Confidential. Release 1.2.0 Revision A | Page 19
6. In the Windows File Selection dialog…
Select the software upgrade package (ZIP file) on either a local or a network drive.
Click the Open button to close the File Selection dialog and to populate the full path name to the
upgrade zip package.
Note: The extraction process on the ZIP file is handled as part of the upgrade process. There is no
need to manually extract these files.
7. Press Submit Transfer... button. A dialog box opens, requesting confirmation to proceed with the file
transfer request…
8. Click Yes confirm the file transfer and to begin the upgrade process.
If multiple devices are selected, then multiple transfer tasks (one per device) begin.
At this point, the Software Upgrade window may be closed and the PC used for other tasks. Closing
the Software Upgrade window does not affect any transfer processes that may be running in the
background. However, if you try to log off or exit the CCS software while a transfer is underway, a
notification window will alert you that processes are still active and will ask if you want to terminate
these processes.
9. See How to Monitor a Software Upgrade (on page 19) for details on how to track upgrade progress
and how to confirm when the upgrade process has completed.
How to Monitor a Software Upgrade
Use this procedure to monitor the status of a software upgrade.
The Software Upgrade dialog offers two mechanisms, the Log Tab and the Progress Tab for determining
the status of an upgrade once it has begun.
1. The Progress Tab provides a table with one row identifying each device scheduled to receive and
upgrade.
The Progress column indicates the current status of any ongoing transfers.
The Transfer Status column indicates the overall success or the failure of each transfer attempt.

IPA6800+
Installation, Configuration, and Operation Manual Firmware Upgrade
© 2016 Imagine Communications Corp. Proprietary and Confidential. Release 1.2.0 Revision A | Page 20
2. The Log Tab provides Pass/Fail status on all file transfer attempts
In the event of a failure of any kind, double-click on the row indicating the failure to open the
Log.
Scroll down to the bottom of the Log to view the last failed action.