2. Cabling
The basic cabling of your gateway is illustrated below:
Use only the supplied 12VDC +/-10%, tolerance, 2A, limited power source wall mount Class II power supply adapter.
Before connecting the gateway to power, ensure that the VAC ratings match, and that you have read the Compliance and
Regulatory Information at www.audiocodes.com/library.
AudioCodes MediaPack™Multimedia Home Gateway
MP-263 Quick Guide
1. Connect the gateway to the Internet using one of the following
connectivity methods:
WAN Ethernet: Connect the WAN Ethernet port (labeled
WAN) to an external modem, using a CAT 5 Ethernet cable.
xDSL: Connect the xDSL port (labeled xDSL) to the
telephone socket, using an RJ-11 telephone cable.
2. Connect the Ethernet ports, labeled LAN 1-4 to your LAN
computers, using CAT 5 Ethernet cables.
3. Connect the telephone ports, labeled Phone 1-2 to analog
telephones, using RJ-11 telephone cables.
4. Connect the gateway to a standard 110/220 VAC electrical wall
outlet, using the supplied AC/DC power adapter.
5. When powered on, the gateway's Status LED turns on. When
initialization completes (~ 2 min.), the LED changes from red to
green. If the gateway is off, press the Power button located on
the rear panel to switch it on.
For wall mounting the gateway, refer to the
User's
Manual
.
Welcome
Thank you for purchasing AudioCodes MediaPack
Multimedia Home Gateway!
This Quick Guide describes installation for AudioCodes
MediaPack 263 model (MP-263).
1. Before Installing
Ensure that the shipped package contains the following items:
MediaPack Multimedia Home Gateway
1 x RJ-45 Ethernet cable
1 x RJ-11 cable for telephone or xDSL
12V AC/DC power adaptor (use only supplied)
If any item is missing, please contact your sales representative.
Notice
Information contained in this document is believed to be accurate and reliable at the time of printing. However, due to ongoing
product improvements and revisions, AudioCodes cannot guarantee accuracy of printed material after the Date Published nor can
it accept responsibility for errors or omissions. This document is subject to change without notice. Refer to the current Release
Notes that may be included with your documentation or hardware delivery. Updates to this document as well as software files can
be viewed by registered customers at www.audiocodes.com/downloads.
© Copyright 2013 AudioCodes Ltd. All rights reserved.
Date Published: April-18-2013
Document #: LTRT-18640
4. Configuring VoIP Parameters
Before you can make VoIP calls, you need to register with an
Internet Telephony Service Provider (ITSP) and obtain account
and SIP Proxy server information
1. From the menu pane, click Voice Over IP; the ‘Voice
Over IP’ page appears in the right pane.
2. Click the Line Settings tab, mark check boxes of lines
that are connected to telephones (clear those not
connected), and then click Apply.
3. Click the Edit icon corresponding to the telephone
lines, and then in the ‘Line Settings’ page, configure the
parameters with values provided by your ISP.
4. Click the Signaling Protocol tab, and then select the ‘Use
SIP Proxy’ check box. In the ‘Proxy IP Address or Host
Name’ field, enter the ITSP’s proxy server IP address or
host name. Click OK to complete the VoIP configuration.
To verify successful registration with
the proxy
server, ensure that the Phone
LED is lit green or in
the Voice over IP tab (System Monitoring menu), the
entry ‘SIP Registration’ displays “Registered” for the
configured lines.
5. Pick up the phone receiver (or handset) and listen for a
dial tone; you’re now ready to make a VoIP call.
3. Configuring Network Parameters
1. Open a Web browser, and then enter the following URL
address to access the gateway's embedded Web server
graphical user interface: http://mp263.home
2. Select the Web GUI display language and click Continue.
3. Define a new login username / password and click OK.
4. In the ‘Quick Setup’ page, select and define the Internet
connection type as instructed by your ITSP, and then
click OK. You are now connected to the Internet and can
proceed to configure VoIP parameters for
making and receiving voice-over-IP calls.
If there is no Int
ernet connection, the Web GUI’s
Map View page (Home) displays a red icon after
the globe icon. Consult your ITSP for valid connection
parameters.
The gateway's default wireless (Wi-Fi) network name
(SSID) comprises product name followed by "_" and
the six last characters of the MAC address in capital
letters (secured). For example, if the MAC address is
00:90:8F:2C:64:70, the SSID will be MP263_2C6470
The password is 0<serial number without first two
characters>. For example, if the SN is VT1234567, the
password will be 01234567. The SN is printed on the
rear of the MP-263.

Other AudioCodes Gateway manuals

AudioCodes M500L Assembly instructions

AudioCodes

AudioCodes M500L Assembly instructions

AudioCodes MediaPack MP-1 Series User manual

AudioCodes

AudioCodes MediaPack MP-1 Series User manual

AudioCodes Mediant 1000B Assembly instructions

AudioCodes

AudioCodes Mediant 1000B Assembly instructions

AudioCodes Mediant 3000 TP-6310 Installation and operation manual

AudioCodes

AudioCodes Mediant 3000 TP-6310 Installation and operation manual

AudioCodes Mediant 800B User manual

AudioCodes

AudioCodes Mediant 800B User manual

AudioCodes Mediant 800 MSBG User manual

AudioCodes

AudioCodes Mediant 800 MSBG User manual

AudioCodes Mediant 800 MSBG User manual

AudioCodes

AudioCodes Mediant 800 MSBG User manual

AudioCodes MP-272-DB User manual

AudioCodes

AudioCodes MP-272-DB User manual

AudioCodes Mediant 2000 User manual

AudioCodes

AudioCodes Mediant 2000 User manual

AudioCodes Mediant 1000 User manual

AudioCodes

AudioCodes Mediant 1000 User manual

AudioCodes Mediant 600 User manual

AudioCodes

AudioCodes Mediant 600 User manual

AudioCodes Mediant 1000 Assembly instructions

AudioCodes

AudioCodes Mediant 1000 Assembly instructions

AudioCodes Mediapack mp-11x User manual

AudioCodes

AudioCodes Mediapack mp-11x User manual

AudioCodes Mediant 4000 SBC User manual

AudioCodes

AudioCodes Mediant 4000 SBC User manual

AudioCodes Mediant 800B User manual

AudioCodes

AudioCodes Mediant 800B User manual

AudioCodes Mediant 8000 Instruction manual

AudioCodes

AudioCodes Mediant 8000 Instruction manual

AudioCodes i Series Assembly instructions

AudioCodes

AudioCodes i Series Assembly instructions

AudioCodes Mediant 800 MSBG Instruction Manual

AudioCodes

AudioCodes Mediant 800 MSBG Instruction Manual

AudioCodes Mediant 600 User manual

AudioCodes

AudioCodes Mediant 600 User manual

AudioCodes MediaPack MP-124 User manual

AudioCodes

AudioCodes MediaPack MP-124 User manual

AudioCodes Mediant 800B User manual

AudioCodes

AudioCodes Mediant 800B User manual

AudioCodes Mediant 2000 User manual

AudioCodes

AudioCodes Mediant 2000 User manual

AudioCodes MP-11 User manual

AudioCodes

AudioCodes MP-11 User manual

AudioCodes Mediant 2000 User manual

AudioCodes

AudioCodes Mediant 2000 User manual

Popular Gateway manuals by other brands

Meraki MG21 installation guide

Meraki

Meraki MG21 installation guide

ELTEC CyBox GW-P installation manual

ELTEC

ELTEC CyBox GW-P installation manual

Mioty Premium Gateway user manual

Mioty

Mioty Premium Gateway user manual

ZyXEL Communications VSG1435 datasheet

ZyXEL Communications

ZyXEL Communications VSG1435 datasheet

LevelOne WHG-1000 Quick installation guide

LevelOne

LevelOne WHG-1000 Quick installation guide

ZyXEL Communications ZyXEL Vantage VSG-1000 Specifications

ZyXEL Communications

ZyXEL Communications ZyXEL Vantage VSG-1000 Specifications

FieldServer ProtoNode FPC-N64 quick start

FieldServer

FieldServer ProtoNode FPC-N64 quick start

Sunrise Internet Box user manual

Sunrise

Sunrise Internet Box user manual

Accsence Gateway and Sensor Pods user guide

Accsence

Accsence Gateway and Sensor Pods user guide

ADTRAN NetVanta 1355 Specifications

ADTRAN

ADTRAN NetVanta 1355 Specifications

FP FP S-OTGuard Seires installation instructions

FP

FP FP S-OTGuard Seires installation instructions

ZyXEL Communications P-660HWP-D1 Specifications

ZyXEL Communications

ZyXEL Communications P-660HWP-D1 Specifications

Centurion SOLO Quick installation guide

Centurion

Centurion SOLO Quick installation guide

FaxBack AudioCodes MP114 Hardware installation

FaxBack

FaxBack AudioCodes MP114 Hardware installation

Moxa Technologies MGate 5105-MB-EIP Quick installation guide

Moxa Technologies

Moxa Technologies MGate 5105-MB-EIP Quick installation guide

QEI ePAQ-9100 manual

QEI

QEI ePAQ-9100 manual

Geniatech GTW350 quick start guide

Geniatech

Geniatech GTW350 quick start guide

Chamberlain MyQ Retrofit 828LM quick start

Chamberlain

Chamberlain MyQ Retrofit 828LM quick start

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.